Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Brain ; 140(11): 2927-2938, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-29053775

RESUMEN

Brain magnetic resonance imaging is an important tool in the diagnosis and monitoring of multiple sclerosis patients. However, magnetic resonance imaging alone provides limited information for predicting an individual patient's disability progression. In part, this is because magnetic resonance imaging lacks sensitivity and specificity for detecting chronic diffuse and multi-focal inflammation mediated by activated microglia/macrophages. The aim of this study was to test for an association between 18 kDa translocator protein brain positron emission tomography signal, which arises largely from microglial activation, and measures of subsequent disease progression in multiple sclerosis patients. Twenty-one patients with multiple sclerosis (seven with secondary progressive disease and 14 with a relapsing remitting disease course) underwent T1- and T2-weighted and magnetization transfer magnetic resonance imaging at baseline and after 1 year. Positron emission tomography scanning with the translocator protein radioligand 11C-PBR28 was performed at baseline. Brain tissue and lesion volumes were segmented from the T1- and T2-weighted magnetic resonance imaging and relative 11C-PBR28 uptake in the normal-appearing white matter was estimated as a distribution volume ratio with respect to a caudate pseudo-reference region. Normal-appearing white matter distribution volume ratio at baseline was correlated with enlarging T2-hyperintense lesion volumes over the subsequent year (ρ = 0.59, P = 0.01). A post hoc analysis showed that this association reflected behaviour in the subgroup of relapsing remitting patients (ρ = 0.74, P = 0.008). By contrast, in the subgroup of secondary progressive patients, microglial activation at baseline was correlated with later progression of brain atrophy (ρ = 0.86, P = 0.04). A regression model including the baseline normal-appearing white matter distribution volume ratio, T2 lesion volume and normal-appearing white matter magnetization transfer ratio for all of the patients combined explained over 90% of the variance in enlarging lesion volume over the subsequent 1 year. Glial activation in white matter assessed by translocator protein PET significantly improves predictions of white matter lesion enlargement in relapsing remitting patients and is associated with greater brain atrophy in secondary progressive disease over a period of short term follow-up.


Asunto(s)
Encéfalo/diagnóstico por imagen , Inflamación/diagnóstico por imagen , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Sustancia Blanca/diagnóstico por imagen , Acetamidas , Adulto , Atrofia , Encéfalo/patología , Radioisótopos de Carbono , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Microglía , Persona de Mediana Edad , Tamaño de los Órganos , Tomografía de Emisión de Positrones , Piridinas , Receptores de GABA , Sustancia Blanca/patología , Adulto Joven
2.
Brain Behav ; 6(2): e00422, 2016 02.
Artículo en Inglés | MEDLINE | ID: mdl-27110445

RESUMEN

INTRODUCTION: There is emerging evidence that brain atrophy is a part of the pathophysiology of Multiple Sclerosis (MS) and correlates with several clinical outcomes of the disease, both physical and cognitive. Consequently, brain atrophy is becoming an important parameter in patients' follow-up. Since in clinical practice both 1.5Tesla (T) and 3T magnetic resonance imaging (MRI) systems are used for MS patients follow-up, questions arise regarding compatibility and a possible need for standardization. METHODS: Therefore, in this study 18 MS patients were scanned on the same day on a 1.5T and a 3T scanner. For each scanner, a 3D T1 and a 3D FLAIR were acquired. As no atrophy is expected within 1 day, these datasets can be used to evaluate the median percentage error of the brain volume measurement for gray matter (GM) volume and parenchymal volume (PV) between 1.5T and 3T scanners. The results are obtained with MSmetrix, which is developed especially for use in the MS clinical care path, and compared to Siena (FSL), a widely used software for research purposes. RESULTS: The MSmetrix median percentage error of the brain volume measurement between a 1.5T and a 3T scanner is 0.52% for GM and 0.35% for PV. For Siena this error equals 2.99%. When data of the same scanner are compared, the error is in the order of 0.06-0.08% for both MSmetrix and Siena. CONCLUSIONS: MSmetrix appears robust on both the 1.5T and 3T systems and the measurement error becomes an order of magnitude higher between scanners with different field strength.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Esclerosis Múltiple/diagnóstico por imagen , Adulto , Atrofia/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Interpretación de Imagen Asistida por Computador , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estudios Prospectivos , Programas Informáticos , Adulto Joven
3.
Brain Behav ; 6(9): e00518, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27688944

RESUMEN

INTRODUCTION: As neurodegeneration is recognized as a major contributor to disability in multiple sclerosis (MS), brain atrophy quantification could have a high added value in clinical practice to assess treatment efficacy and disease progression, provided that it has a sufficiently low measurement error to draw meaningful conclusions for an individual patient. METHOD: In this paper, we present an automated longitudinal method based on Jacobian integration for measuring whole-brain and gray matter atrophy based on anatomical magnetic resonance images (MRI), named MSmetrix. MSmetrix is specifically designed to measure atrophy in patients with MS, by including iterative lesion segmentation and lesion filling based on FLAIR and T1-weighted MRI scans. RESULTS: MS metrix is compared with SIENA with respect to test-retest error and consistency, resulting in an average test-retest error on an MS data set of 0.13% (MS metrix) and 0.17% (SIENA) and a consistency error of 0.07% (MS metrix) and 0.05% (SIENA). On a healthy subject data set including physiological variability the test-retest is 0.19% (MS metrix) and 0.31% (SIENA). CONCLUSION: Therefore, we can conclude that MSmetrix could be of added value in clinical practice for the follow-up of treatment and disease progression in MS patients.

4.
BMJ Open ; 4(3): e004399, 2014 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-24662447

RESUMEN

OBJECTIVES: Vasodilation of the peripheral arteries during reactive hyperaemia depends in part on release of nitric oxide from endothelial cells. Previous studies mainly employed a fingertip tonometric device to derive pulse wave amplitude (PWA) and PWA hyperaemic changes. An alternative approach is based on photoplethysmography (PPG). We sought to evaluate the correlates of digital PPG PWA hyperaemic responses as a measure of peripheral vascular function. DESIGN: The Flemish Study on Environment, Genes and Health Outcomes (FLEMENGHO) is a population-based cohort study. SETTING: Respondents were examined at one centre in northern Belgium. PARTICIPANTS: For this analysis, our sample consisted of 311 former participants (53.5% women; mean age 52.6 years; 43.1% hypertensive), who were examined from January 2010 until March 2012 (response rate 85.1%). PRIMARY OUTCOME MEASURES: Using a fingertip PPG device, we measured digital PWA at baseline and at 30 s intervals for 4 min during reactive hyperaemia induced by a 5 min forearm cuff occlusion. We performed stepwise regression to identify correlates of the hyperaemic response ratio for each 30 s interval after cuff deflation. RESULTS: The maximal hyperaemic response was detected in the 30-60 s interval. The explained variance for the PPG PWA ratio ranged from 9.7% at 0-30 s interval to 22.5% at 60-90 s time interval. The hyperaemic response at each 30 s interval was significantly higher in women compared with men (p≤0.001). The PPG PWA changes at 0-90 s intervals decreased with current smoking (p≤0.0007) and at 0-240 s intervals decreased with higher body mass index (p≤0.035). These associations with sex, current smoking and body mass index were mutually independent. CONCLUSIONS: Our study is the first to implement the new PPG technique to measure digital PWA hyperaemic changes in a general population. Hyperaemic response, as measured by PPG, is inversely associated with traditional cardiovascular risk factors such as male sex, smoking and obesity.


Asunto(s)
Arterias , Índice de Masa Corporal , Enfermedades Cardiovasculares/etiología , Endotelio Vascular/fisiopatología , Hiperemia/fisiopatología , Fumar/fisiopatología , Vasodilatación , Adulto , Anciano , Arterias/fisiología , Arterias/fisiopatología , Bélgica , Enfermedades Cardiovasculares/fisiopatología , Estudios de Cohortes , Endotelio Vascular/fisiología , Femenino , Dedos/irrigación sanguínea , Dedos/fisiología , Frecuencia Cardíaca , Humanos , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Sobrepeso/complicaciones , Sobrepeso/fisiopatología , Fotopletismografía/métodos , Pulso Arterial , Análisis de la Onda del Pulso , Factores de Riesgo , Factores Sexuales , Fumar/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA