Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Rev Lett ; 111(6): 065003, 2013 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-23971581

RESUMEN

The first measurements of multiple, high-pressure shock waves in cryogenic deuterium-tritium (DT) ice layered capsule implosions on the National Ignition Facility have been performed. The strength and relative timing of these shocks must be adjusted to very high precision in order to keep the DT fuel entropy low and compressibility high. All previous measurements of shock timing in inertial confinement fusion implosions [T. R. Boehly et al., Phys. Rev. Lett. 106, 195005 (2011), H. F. Robey et al., Phys. Rev. Lett. 108, 215004 (2012)] have been performed in surrogate targets, where the solid DT ice shell and central DT gas regions were replaced with a continuous liquid deuterium (D2) fill. This report presents the first experimental validation of the assumptions underlying this surrogate technique.

2.
Phys Rev Lett ; 111(23): 235001, 2013 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-24476279

RESUMEN

On the National Ignition Facility, the hohlraum-driven implosion symmetry is tuned using cross-beam energy transfer (CBET) during peak power, which is controlled by applying a wavelength separation between cones of laser beams. In this Letter, we present early-time measurements of the instantaneous soft x-ray drive at the capsule using reemission spheres, which show that this wavelength separation also leads to significant CBET during the first shock, even though the laser intensities are 30× smaller than during the peak. We demonstrate that the resulting early drive P2/P0 asymmetry can be minimized and tuned to <1% accuracy (well within the ±7.5% requirement for ignition) by varying the relative input powers between different cones of beams. These experiments also provide time-resolved measurements of CBET during the first 2 ns of the laser drive, which are in good agreement with radiation-hydrodynamics calculations including a linear CBET model.

3.
Phys Rev Lett ; 108(13): 135006, 2012 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-22540711

RESUMEN

We have imaged hard x-ray (>100 keV) bremsstrahlung emission from energetic electrons slowing in a plastic ablator shell during indirectly driven implosions at the National Ignition Facility. We measure 570 J in electrons with E>100 keV impinging on the fusion capsule under ignition drive conditions. This translates into an acceptable increase in the adiabat α, defined as the ratio of total deuterium-tritium fuel pressure to Fermi pressure, of 3.5%. The hard x-ray observables are consistent with detailed radiative-hydrodynamics simulations, including the sourcing and transport of these high energy electrons.

4.
Phys Rev Lett ; 106(8): 085003, 2011 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-21405579

RESUMEN

The first soft x-ray radiation flux measurements from hohlraums using both a 96 and a 192 beam configuration at the National Ignition Facility have shown high x-ray conversion efficiencies of ∼85%-90%. These experiments employed gold vacuum hohlraums, 6.4 mm long and 3.55 mm in diameter, heated with laser energies between 150-635 kJ. The hohlraums reached radiation temperatures of up to 340 eV. These hohlraums for the first time reached coronal plasma conditions sufficient for two-electron processes and coronal heat conduction to be important for determining the radiation drive.

5.
Rev Sci Instrum ; 81(10): 10E321, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21034019

RESUMEN

The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an ∼20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30±10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of ∼2×10(15) W/cm(2) for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1×10(14) W/cm(2) over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to ±5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30±10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.

6.
Science ; 327(5970): 1228-31, 2010 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-20110465

RESUMEN

Indirect-drive hohlraum experiments at the National Ignition Facility have demonstrated symmetric capsule implosions at unprecedented laser drive energies of 0.7 megajoule. One hundred and ninety-two simultaneously fired laser beams heat ignition-emulate hohlraums to radiation temperatures of 3.3 million kelvin, compressing 1.8-millimeter-diameter capsules by the soft x-rays produced by the hohlraum. Self-generated plasma optics gratings on either end of the hohlraum tune the laser power distribution in the hohlraum, which produces a symmetric x-ray drive as inferred from the shape of the capsule self-emission. These experiments indicate that the conditions are suitable for compressing deuterium-tritium-filled capsules, with the goal of achieving burning fusion plasmas and energy gain in the laboratory.

8.
Appl Opt ; 47(19): 3494-9, 2008 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-18594596

RESUMEN

A single beamline of the National Ignition Facility (NIF) has been operated at a wavelength of 526.5 nm (2 omega) by frequency converting the fundamental 1053 nm (1 omega) wavelength with an 18.2 mm thick type-I potassium dihydrogen phosphate (KDP) second-harmonic generator (SHG) crystal. Second-harmonic energies of up to 17.9 kJ were measured at the final optics focal plane with a conversion efficiency of 82%. For a similarly configured 192-beam NIF, this scales to a total 2 omega energy of 3.4 MJ full NIF equivalent (FNE).

9.
Appl Opt ; 46(16): 3276-303, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17514286

RESUMEN

The National Ignition Facility (NIF) is the world's largest laser system. It contains a 192 beam neodymium glass laser that is designed to deliver 1.8 MJ at 500 TW at 351 nm in order to achieve energy gain (ignition) in a deuterium-tritium nuclear fusion target. To meet this goal, laser design criteria include the ability to generate pulses of up to 1.8 MJ total energy, with peak power of 500 TW and temporal pulse shapes spanning 2 orders of magnitude at the third harmonic (351 nm or 3omega) of the laser wavelength. The focal-spot fluence distribution of these pulses is carefully controlled, through a combination of special optics in the 1omega (1053 nm) portion of the laser (continuous phase plates), smoothing by spectral dispersion, and the overlapping of multiple beams with orthogonal polarization (polarization smoothing). We report performance qualification tests of the first eight beams of the NIF laser. Measurements are reported at both 1omega and 3omega, both with and without focal-spot conditioning. When scaled to full 192 beam operation, these results demonstrate, to the best of our knowledge for the first time, that the NIF will meet its laser performance design criteria, and that the NIF can simultaneously meet the temporal pulse shaping, focal-spot conditioning, and peak power requirements for two candidate indirect drive ignition designs.

10.
Phys Rev Lett ; 94(9): 095005, 2005 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-15783974

RESUMEN

The first hydrodynamic experiments were performed on the National Ignition Facility. A supersonic jet was formed via the interaction of a laser driven shock ( approximately 40 Mbar) with 2D and 3D density perturbations. The temporal evolution of the jet's spatial scales and ejected mass were measured with point-projection x-ray radiography. Measurements of the large-scale features and mass are in good agreement with 2D and 3D numerical simulations. These experiments provide quantitative data on the evolution of 3D supersonic jets and provide insight into their 3D behavior.

11.
Phys Rev Lett ; 95(21): 215004, 2005 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-16384150

RESUMEN

The first hohlraum experiments on the National Ignition Facility (NIF) using the initial four laser beams tested radiation temperature limits imposed by plasma filling. For a variety of hohlraum sizes and pulse lengths, the measured x-ray flux shows signatures of filling that coincide with hard x-ray emission from plasma streaming out of the hohlraum. These observations agree with hydrodynamic simulations and with an analytical model that includes hydrodynamic and coronal radiative losses. The modeling predicts radiation temperature limits with full NIF (1.8 MJ), greater, and of longer duration than required for ignition hohlraums.

12.
Appl Opt ; 31(21): 4172-4, 1992 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-20725398

RESUMEN

The cubic nonlinear susceptibility of barium metaborate was employed for the generation of phase-matched third-harmonic generation (THG) of 1.053-microm pump radiation. The various processes that are responsible for THG in this crystal are discussed and experimental results for types I and II phase matching are presented. THG power of 50 microW is recorded with an average pump power of 800 mW of 1-kHz repetition rate picosecond pulses.

13.
Opt Lett ; 14(3): 183-5, 1989 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-19749863

RESUMEN

We have constructed a new interferometer that uses two phase-conjugate mirrors. This device allows for the measurement of the relative phase shift and the ratio of the nonlinear susceptibilities of materials. We have been able to measure weak reflectivity signals not detectable by normal degenerate four-wave mixing methods. It has been determined that the x((3)) value of colloid semiconductor glass OG530 at 532 nm is 7 x 10(-12) esu.

14.
Appl Opt ; 36(21): 4932-53, 1997 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-18259297

RESUMEN

The Beamlet is a single-beam prototype of future multibeam megajoule-class Nd:glass laser drivers for inertial confinement fusion. It uses a multipass main amplifier, adaptive optics, and efficient, high-fluence frequency conversion to the third harmonic. The Beamlet amplifier contains Brewster-angle glass slabs with a clear aperture of 39 cm x 39 cm and a full-aperture plasma-electrode Pockels cell switch. It has been successfully tested over a range of pulse lengths from 1-10 ns up to energies at 1.053 mum of 5.8 kJ at 1 ns and 17.3 kJ at 10 ns. A 39-actuator deformable mirror corrects the beam quality to a Strehl ratio of as much as 0.4. The 1.053-mum output has been converted to the third harmonic at efficiencies as high as 80% and fluences as high as 8.7 J/cm(2) for 3-ns pulses.

15.
Appl Opt ; 37(12): 2371-8, 1998 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-18273166

RESUMEN

Spatial filters are essential components for maintaining high beam quality in high-energy pulsed laser systems. The long-duration (21 ns) high-energy pulses envisioned for future inertial-confinement fusion drive systems, such as the U.S. National Ignition Facility (NIF), are likely to lead to increased plasma generation and closure effects within the pinholes in the spatial filters. The design goal for the pinhole spatial filter for the NIF design is to remove small-angle scatter in the beam to as little as a ?100-murad divergence. It is uncertain whether this design requirement can be met with a conventional pinhole design. We propose a new pinhole architecture that addresses these issues by incorporating features intended to reduce the rate of plasma generation. Initial experiments with this design have verified its performance improvement relative to a conventional pinhole design.

16.
Appl Opt ; 39(25): 4540-6, 2000 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-18350042

RESUMEN

We performed a direct side-by-side comparison of a Shack-Hartmann wave-front sensor and a phase-shifting interferometer for the purpose of characterizing large optics. An expansion telescope of our own design allowed us to measure the surface figure of a 400-mm-square mirror with both instruments simultaneously. The Shack-Hartmann sensor produced data that closely matched the interferometer data over spatial scales appropriate for the lenslet spacing, and much of the <20-nm rms systematic difference between the two measurements was due to diffraction artifacts that were present in the interferometer data but not in the Shack-Hartmann sensor data. The results suggest that Shack-Hartmann sensors could replace phase-shifting interferometers for many applications, with particular advantages for large-optic metrology.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA