Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38819910

RESUMEN

BACKGROUND: Most patients undergoing the mitral transcatheter edge-to-edge repair (TEER) technique are elderly comorbid patients. Low body mass index (BMI) < 23 kg/m2 has been identified in other elderly populations as a risk factor, but has not been studied sufficiently in mitral TEER. AIMS: We aimed to study the impact of low BMI (23 kg/m2) on the outcome after mitral TEER. METHODS: Patients undergoing first-time TEER for mitral regurgitation at a single tertiary center were included, with the exclusion of patients with preprocedural hemodynamic instability or missing BMI. The primary endpoint was all-cause mortality. Secondary endpoints were long-term major bleeding or admission with heart failure. RESULTS: A total of 120 patients (mean age 76 ± 10 years, 76% men) were included in the study. Thirty-nine (31%) had low BMI. Patients with low BMI had a similar symptomatic benefit as patients with BMI ≥ 23 kg/m2 at 1 year regarding decrease in diuretics dose and decrease in New York Heart Association (NYHA) class (p > 0.05). In a multivariable Cox regression analysis, BMI as a continuous variable (hazard ratio [HR]: 0.93 [95% confidence interval, CI: 0.87-0.99], p = 0.03) and low BMI (HR: 1.99 [95% CI: 1.12-3.52], p = 0.02) were associated with the primary outcome. Low BMI was not significantly associated with major bleeding (subdistribution hazard ratio [SHR]: 2.39 [95% CI: 0.96-5.97], p = 0.06) or admission with heart failure (SHR: 1.06 [95% CI: 0.61-1.88], p = 0.83) during follow-up with univariable competing risk regression analysis. CONCLUSION: Low BMI is a risk factor for mortality after mitral valve TEER, confirming the presence of an "obesity paradox" in this population and should receive attention in patient selection.

2.
Catheter Cardiovasc Interv ; 103(2): 276-285, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38091338

RESUMEN

BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.


Asunto(s)
Síndrome Coronario Agudo , Ácidos Alcanesulfónicos , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Trombosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Factores de Riesgo , Resultado del Tratamiento , Stents Liberadores de Fármacos/efectos adversos , Implantes Absorbibles , Diseño de Prótesis , Fármacos Cardiovasculares/efectos adversos , Trombosis Coronaria/etiología , Stents/efectos adversos , Polímeros , Intervención Coronaria Percutánea/efectos adversos
3.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31733182

RESUMEN

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Asunto(s)
Válvula Aórtica/fisiopatología , Aspirina/farmacología , Clopidogrel/farmacología , Inhibidores del Factor Xa/farmacología , Prótesis Valvulares Cardíacas , Inhibidores de Agregación Plaquetaria/farmacología , Rivaroxabán/farmacología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/efectos de los fármacos , Válvula Aórtica/patología , Aspirina/efectos adversos , Aspirina/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Clopidogrel/uso terapéutico , Quimioterapia Combinada , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Femenino , Tomografía Computarizada Cuatridimensional , Hemorragia/inducido químicamente , Humanos , Análisis de Intención de Tratar , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Rivaroxabán/efectos adversos , Rivaroxabán/uso terapéutico , Tromboembolia/etiología , Tromboembolia/mortalidad
4.
Am Heart J ; 257: 41-50, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36423733

RESUMEN

BACKGROUND: Chronic total occlusions (CTO) are frequent among patients with coronary artery disease. Revascularization with percutaneous coronary intervention (PCI) is safe and feasible in experienced hands. However, randomized data are needed to demonstrate symptomatic as well as prognostic effect of CTO-PCI compared to optimal medical therapy alone. METHODS: This trial aims to evaluate the effect of CTO PCI in patients with a CTO lesion and target vessel diameter ≥ 2.5 mm, and myocardial ischemia in the relevant territory. First, all patients are subjected to optimal medical therapy (OMT) for at least for 3 months and non-CTO lesions are managed according to guidelines. Subsequently, prior to randomization myocardial ischemia and quality of life (Seattle Questionnaire (SAQ)) is assessed. Patients are divided into two cohorts based on their SAQ score and randomized to either OMT alone or OMT and CTO-PCI. Cohort A is defined as Low- or asymptomatic patients with a quality-of-life score > 60 and/or CCS class < 2, and more than 10 % ischemia in the left ventricle (LV). Cohort B is symptomatic patients with a quality-of-life score < 60 or CCS class angina > 1 and at least ischemia in 5% of the LV. The primary end-point in cohort A is a composite of major adverse cardiac and cerebral events, hospitalization for heart failure and malignant ventricular arrhythmias. The primary endpoint in cohort B is difference in quality of life 6 months after randomization. IMPLICATIONS: This trial is designed to investigate if CTO-PCI improves QoL and MACCE. Both positive and negative outcome of the trial will affect future guidelines and recommendations on how to treat patients with CTO.


Asunto(s)
Enfermedad de la Arteria Coronaria , Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Oclusión Coronaria/cirugía , Enfermedad de la Arteria Coronaria/etiología , Calidad de Vida , Intervención Coronaria Percutánea/efectos adversos , Angina de Pecho/etiología , Enfermedad Crónica , Resultado del Tratamiento
5.
Am Heart J ; 255: 39-51, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36220354

RESUMEN

BACKGROUND: Coronary artery disease (CAD) frequently coexists with severe aortic valve stenosis (AS) in patients planned for transcatheter aortic valve implantation (TAVI). How to manage CAD in this patient population is still an unresolved question. In particular, it is still not known whether fractional flow reserve (FFR) guided revascularization with percutaneous coronary intervention (PCI) is superior to medical treatment for CAD in terms of clinical outcomes. STUDY DESIGN: The third Nordic Aortic Valve Intervention (NOTION-3) Trial is an open-label investigator-initiated, multicenter multinational trial planned to randomize 452 patients with severe AS and significant CAD to either FFR-guided PCI or medical treatment, in addition to TAVI. Patients are eligible for the study in the presence of at least 1 significant PCI-eligible coronary stenosis. A significant stenosis is defined as either FFR ≤0.80 and/or diameter stenosis >90%. The primary end point is a composite of first occurring all-cause mortality, myocardial infarction, or urgent revascularization (PCI or coronary artery bypass graft performed during unplanned hospital admission) until the last included patient have been followed for 1 year after the TAVI. SUMMARY: NOTION-3 is a multicenter, multinational randomized trial aiming at comparing FFR-guided revascularization vs medical treatment of CAD in patients with severe AS planned for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Constricción Patológica , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Angiografía Coronaria
6.
Catheter Cardiovasc Interv ; 101(1): 13-21, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378691

RESUMEN

OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.


Asunto(s)
Síndrome Coronario Agudo , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus/efectos adversos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Factores de Riesgo , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Implantes Absorbibles , Fármacos Cardiovasculares/efectos adversos , Factores de Tiempo , Diseño de Prótesis , Infarto del Miocardio/etiología , Stents Liberadores de Fármacos/efectos adversos
7.
Circulation ; 143(22): 2155-2165, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33823606

RESUMEN

BACKGROUND: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population. METHODS: The SORT OUT X (Combo Stent Versus Orsiro Stent) trial, was a large-scale, randomized, multicenter, single-blind, 2-arm, noninferiority trial with registry-based follow-up. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction, or target lesion revascularization within 12 months, analyzed using intention-to-treat. The trial was powered for assessing target lesion failure noninferiority of the DTS compared with the SES with a predetermined noninferiority margin of 0.021. RESULTS: A total of 3146 patients were randomized to treatment with the DTS (1578 patients; 2008 lesions) or SES (1568 patients; 1982 lesions). At 12 months, intention-to-treat analysis showed that 100 patients (6.3%) assigned the DTS and 58 patients (3.7%) assigned the SES met the primary end point (absolute risk difference, 2.6% [upper limit of 1-sided 95% CI, 4.1%]; P (noninferiority)=0.76). The SES was superior to the DTS (incidence rate ratios for target lesion failure, 1.74 [95% CI, 1.26-2.41]; P=0.00086). The difference was explained mainly by a higher incidence of target lesion revascularization in the DTS group compared with the SES group (53 [3.4%] vs. 24 [1.5%]; incidence rate ratio, 2.22 [95% CI, 1.37-3.61]; P=0.0012). CONCLUSIONS: The DTS did not confirm noninferiority to the SES for target lesion failure at 12 months in an all-comer population. The SES was superior to the DTS mainly because the DTS was associated with an increased risk of target lesion revascularization. However, rates of death, cardiac death, and myocardial infarction at 12 months did not differ significantly between the 2 stent groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03216733.


Asunto(s)
Antibacterianos/uso terapéutico , Antígenos CD34/metabolismo , Stents Liberadores de Fármacos/normas , Intervención Coronaria Percutánea/métodos , Sirolimus/uso terapéutico , Anciano , Antibacterianos/farmacología , Femenino , Humanos , Masculino , Sirolimus/farmacología , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 99(4): 1095-1103, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35043539

RESUMEN

This sub-study of the SORT OUT IX trial sought to compare clinical outcomes between patients with diabetes randomized to implantation of either the polymer-free biolimus A9-coated BioFreedom stent (BF-BES) or the ultra-thin strut, biodegradable polymer sirolimus-eluting Orsiro stent (O-SES). Patients with diabetes have an increased risk of target lesion failure (TLF) after percutaneous coronary intervention (PCI). The impact of different stent types in patients with diabetes is still discussed. A total of 607 of the 3151 patients (19.3%) enrolled in the SORT OUT IX study had diabetes. Randomization was stratified by patients with/without diabetes; 304 received BF-BES and 303 O-SES. The primary endpoint was TLF, which was a composite of cardiac death, myocardial infarction (not related to other than the index lesion) and target lesion revascularization (TLR) within 1 year. After 1 year, patients with diabetes had higher TLF (7.2% vs. 3.7%, incidence rate ratio [IRR]: 1.65; 95% confidence interval [CI]: 1.08-2.50), than patients without diabetes. TLF did not differ significantly between BF-BES and O-SES in patients with diabetes (8.2% vs. 6.3%, IRR: 1.17; 95% CI: 0.63-2.20). In patients with diabetes, cardiac death occurred in 2.3% of BF-BES and in 3.6% of O-SES (IRR: 0.58; 95% CI: 0.23-1.45) and TLR occurred in 5.3% and 2.3% of BF-BES and O-SES, respectively (IRR: 2.12; 95% CI: 0.81-5.56). Definite stent thrombosis rates of 1.3% were found in both stent types. Patients with diabetes had higher 1-year TLF rate after PCI compared to patients without diabetes, whereas TLF did not differ significantly between the two stent types BF-BES and O-SES in patients with diabetes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Muerte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Humanos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Diseño de Prótesis , Stents , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 99(7): 1965-1975, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35384254

RESUMEN

OBJECTIVES: To compare the efficacy and safety of the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (SES) in patients with and without diabetes mellitus (DM) included in the Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT) X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with DM when compared to patients without DM. Thus, whether the results from the SORT OUT X study apply to patients with and without DM remains unknown. METHODS: In total 3146 patients were randomized to stent implantation with DTS (n = 1578; DM: n = 279) or SES (n = 1568; DM: n = 271). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was increased in the DTS group compared to the SES group, both among patients with DM (9.3% vs. 4.8%; risk difference: 4.5%; incidence rate ratio: 1.99, 95% confidence interval [CI]: 1.02-3.90) and without DM (5.7% vs. 3.5%; incidence rate ratio: 1.67, 95% CI: 1.15-2.42). The differences were mainly explained by higher rates of TLR. CONCLUSION: Compared to the SES, the DTS was associated with an increased risk of TLF at 12 months in patients with and without DM. The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without DM.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Infarto del Miocardio , Intervención Coronaria Percutánea , Implantes Absorbibles , Antígenos CD34/inmunología , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/terapia , Muerte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Sirolimus/efectos adversos , Stents , Resultado del Tratamiento
10.
Circulation ; 141(25): 2052-2063, 2020 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-32434381

RESUMEN

BACKGROUND: In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention. METHODS: The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial. The primary end point, major adverse cardiovascular events, was defined as the composite of cardiac death, myocardial infarction not related to any segment other than the target lesion, or target lesion revascularization within 1 year, analyzed by intention-to-treat. The trial was powered to assess noninferiority for major adverse cardiovascular events of the BioFreedom stent compared with the Orsiro stent with a predetermined noninferiority margin of 0.021. RESULTS: Between December 14, 2015 and April 21, 2017, 3151 patients were assigned to treatment with the BioFreedom stent (1572 patients, 1966 lesions) or to the Orsiro stent (1579 patients, 1985 lesions). Five patients were lost to follow-up because of emigration (99.9% follow-up rate). Mean age was 66.3±10.9, diabetes mellitus was seen in 19.3% of patients, and 53% of the patients had acute coronary syndromes. At 1 year, intention-to-treat analysis showed that 79 (5.0%) patients, who were assigned the BioFreedom stent, and 59 (3.7%), who were assigned the Orsiro stent, met the primary end point (absolute risk difference 1.29% [upper limit of one-sided 95% CI 2.50%]; Pnoninferiority=0.14). Significantly more patients in the BioFreedom stent group had target lesion revascularization than those in the Orsiro stent group (55 [3.5%] vs 20 [1.3%], rate ratio 2.77 [95% CI, 1.66-4.62]; P<0.0001). CONCLUSIONS: The biolimus A9-coated BioFreedom polymer-free stent did not meet criteria for noninferiority for major adverse cardiovascular events at 12 months when compared with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02623140.


Asunto(s)
Implantes Absorbibles , Antiinflamatorios , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Sirolimus/análogos & derivados , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/etiología , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 93(4): 567-573, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244533

RESUMEN

OBJECTIVES: In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared. BACKGROUND: Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention. METHODS: In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years. RESULTS: At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95). CONCLUSION: TLF did not differ between O-SES- and N-BES-treated diabetic patients.


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Polímeros , Sirolimus/análogos & derivados , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
12.
Cardiology ; 142(3): 141-148, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31170719

RESUMEN

Current guidelines do not recommend coronary computed tomography angiography (CCTA) in patients with high levels of coronary calcium, as severe calcification leads to difficulties in estimating stenosis severity due to blooming artifacts obscuring the vessel lumen. Whether the CCTA-derived fractional flow reserve (FFRCT) improves the diagnostic performance of CCTA in patients with high levels of coronary calcification has not been sufficiently evaluated. We hypothesize that a noninvasive diagnostic strategy using FFRCT will perform comparably to an invasive diagnostic strategy in the detection of hemodynamically significant coronary artery disease (CAD) in clinical stable chest pain patients with high levels of coronary calcium. In this prospective, blinded, multicenter study, patients with suspected stable CAD referred for CCTA and demonstrating an Agatston score >399 will be included. Patients accepting inclusion will, in addition to CCTA, undergo invasive coronary angiography (ICA) and invasive FFR measurement. FFRCT analyses are performed by an external core laboratory blinded to any patient data, and the FFRCT results are blinded to all participating study sites. The primary objective is to evaluate whether FFRCT can identify patients with and without hemodynamically significant CAD, when ICA with FFR is the reference standard. A negative study result would question the clinical usefulness of FFRCT in patients with high levels of coronary calcium. A positive study result, however, would imply a reduction in the number of patients referred for coronary catheterization and, at the same time, increase the proportion of patients with hemodynamically significant CAD at the subsequent invasive examination.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Calcificación Vascular/diagnóstico por imagen , Calcio/sangre , Cateterismo Cardíaco , Dolor en el Pecho/etiología , Enfermedad de la Arteria Coronaria/fisiopatología , Dinamarca , Hemodinámica , Humanos , Estudios Multicéntricos como Asunto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Calcificación Vascular/fisiopatología
13.
Lancet ; 385(9977): 1527-35, 2015 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-25601789

RESUMEN

BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All patients who presented with stable coronary artery disease or acute coronary syndromes and at least one coronary artery lesion (more than 50% stenosis) from March, 2011, to August, 2012, were assessed for eligibility. Patients were randomly assigned in a 1:1 ratio to receive either the durable-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat. The trial was powered to assess non-inferiority of durable-polymer zotarolimus-eluting stent compared with the biodegradable-polymer biolimus-eluting stent with a predetermined non-inferiority margin of 0·025. This trial is registered with ClinicalTrials.gov, number NCT01956448. FINDINGS: Of 7103 screened, 1502 patients with 1883 lesions were assigned to receive the durable-polymer zotarolimus-eluting stent and 1497 patients with 1791 lesions to receive the biodegradable-polymer biolimus-eluting stent. 79 (5·3%) and 75 (5·0%) patients, respectively, met the primary endpoint (absolute risk difference 0·0025, upper limit of one-sided 95% CI 0·016%; p=0·004). The individual components of the primary endpoint did not differ significantly between stent types at 12 months. INTERPRETATION: The durable-polymer-coated zotarolimus-eluting stent was non-inferior to the biodegradable-polymer-coated biolimus-eluting stent in unselected patients. FUNDING: Medtronic Cardiovascular and Biosensors Interventional Technologies.


Asunto(s)
Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Isquemia Miocárdica/terapia , Intervención Coronaria Percutánea , Sirolimus/análogos & derivados , Implantes Absorbibles , Anciano , Materiales Biocompatibles Revestidos , Dinamarca , Diseño de Equipo , Femenino , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/etiología , Isquemia Miocárdica/mortalidad , Polímeros , Sirolimus/administración & dosificación , Resultado del Tratamiento
14.
Coron Artery Dis ; 35(2): 92-98, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38009377

RESUMEN

BACKGROUND: Cardiac 15 O-water PET is a noninvasive method to evaluate epicardial and microvascular dysfunction and further quantitate absolute myocardial blood flow (MBF). AIM: The aim of this study was to assess the impact of revascularization on MBF and myocardial flow reserve (MFR) assessed with 15 O-water PET and invasive flow and pressure measurements. METHODS: In 21 patients with single-vessel disease referred for percutaneous coronary intervention (PCI), serial PET perfusion imaging and fractional flow reserve (FFR), coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) were performed during PCI and after 3 months. RESULTS: In the affected myocardium, stress MBF and MFR increased significantly from before revascularization to 3 months after revascularization: stress MBF 2.4 ±â€…0.8 vs. 3.2 ±â€…0.8; P  < 0.001 and MFR 2.5 ±â€…0.8 vs. 3.4 ±â€…1.1; P  = 0.004. FFR and CFR increased significantly from baseline to after revascularization and remained stable from after revascularization to 3-month follow-up: FFR 0.64 ±â€…0.20 vs. 0.91 ±â€…0.06 vs. 0.91 ±â€…0.07; P  < 0.001; CFR 2.4 ±â€…1.2 vs. 3.6 ±â€…1.9 vs. 3.6 ±â€…1.9; P  < 0.001, whereas IMR did not change significantly: 30.3 ±â€…22.9 vs. 30.1 ±â€…25.3 vs. 31.9 ±â€…25.2; P  = ns. After revascularization, an increase in stress MBF was associated with an increase in FFR ( r  = 0.732; P  < 0.001) and an increase in MFR ( r  = 0.499; P  = 0.021). IMR measured before PCI was inversely associated with improvement in stress MBF, ( r  = -0.616; P  = 0.004). CONCLUSION: Recovery of myocardial perfusion after PCI was associated with an increase in FFR 3 months after revascularization. Microcirculatory dysfunction was associated with less improvement in myocardial perfusion.


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Reserva del Flujo Fraccional Miocárdico/fisiología , Angiografía Coronaria/métodos , Microcirculación/fisiología , Intervención Coronaria Percutánea/efectos adversos , Angina Estable/diagnóstico por imagen , Angina Estable/terapia , Angina Estable/etiología , Agua , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología
15.
Contemp Clin Trials Commun ; 38: 101260, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38384894

RESUMEN

Introduction: Percutaneous coronary intervention with implantation of a bioresorbable scaffold (BRS) provide the vessel support for a limited period allowing the vessel to restore normal vasomotion after degradation of the BRS, opposed to treatment with drug-eluting stents where the metal persist in the vessel wall. Late lumen loss and reduction in lumen area after implantation have been reported. The purpose of this study was to investigate whether intense pre-dilatation before BRS implantation resulted in less reduction of minimal lumen area at 6- and 12-month follow-up after implantation of a Magmaris BRS (MgBRS). Coronary imaging with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) was assessed to track changes in lumen and vessel dimensions. Methods: The prospective Optimal lesion PreparaTion before Implantation of the Magmaris bioresorbable scaffold In patients with coronary artery Stenosis (OPTIMIS) study randomly assigned eighty-two patients with chronic coronary syndrome to two pre-dilatation treatment strategies. Patients were randomized in a 1:1 ratio to pre-dilatation with either a non-compliant scoring balloon or a standard non-compliant balloon prior to implantation of a MgBRS. The treated segment was evaluated with OCT and IVUS at baseline, after 6 and 12 months to assess changes in lumen and vessel dimensions. The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation. The power calculation used expected MLA after 6 months (6.22 mm2 for the scoring balloon and 5.01 mm2 for the standard non-compliant balloon), power of 80 %, significance level of 0.05 and expected drop-out rate of 15 %, requiring 82 patients to be enrolled. Results: Eighty-two patients were included in the study. Enrollment was from December 2020 to September 2023. Conclusion: The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation.

16.
Eur Heart J Case Rep ; 7(7): ytad307, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37485290

RESUMEN

Background: Pulmonary embolism (PE) is common, and it is the third leading cause of cardiovascular death. The management of patients with high-risk PE generally consists of systemic thrombolysis; however, surgical or catheter-directed treatment (CDT) can be considered in selected cases. Case summary: A 78-year-old female patient presenting with acute severe dyspnoea develops out-of-hospital cardiac arrest (OHCA). She was admitted with return of spontaneous circulation and a critical haemodynamic state upon arrival to the catheterization laboratory with an estimated no-flow time of 1 min and low-flow time of 52 min. An acute pulmonary angiogram reveals massive PE. After a PE response team conference, the patient was not found eligible for extracorporeal membrane oxygenation, surgery, or thrombolysis. The patient was treated with catheter-directed mechanical thrombectomy 129 min after first medical contact. The patient recovered and was discharged without any neurological deficits. Discussion: Catheter-directed mechanical thrombectomy was a successful treatment in a patient with OHCA secondary to high-risk PE, where thrombolysis and surgical interventions were considered contraindicated. This case underlines the future perspectives of CDT and also that a multidisciplinary team approach may benefit patients with high-risk PE.

17.
Eur Heart J Cardiovasc Pharmacother ; 9(7): 617-626, 2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37403404

RESUMEN

AIMS: To characterize and follow patients with ST-segment elevation myocardial infarction (STEMI) at high bleeding risk (HBR) according to the predicting bleeding complications in patients undergoing stent implantation and subsequent dual antiplatelet therapy (PRECISE-DAPT) score, and to examine the use of P2Y12 inhibitors and the subsequent risk of major adverse cardiovascular events (MACE) and bleeding. METHODS AND RESULTS: This single-centre cohort study included 6179 consecutive STEMI patients who underwent percutaneous coronary intervention (PCI) at Copenhagen University Hospital, Rigshospitalet, between 2009 and 2016. Individual linkage to nationwide registries was conducted to obtain information on diagnoses, claimed drugs, and vital status. Of the 5532 (89.5%) patients with available PRECISE-DAPT scores, 33.0% were at HBR and more often elderly and female with more comorbidities than non-HBR patients. One-year cumulative incidence rates per 100 person-years were 8.7 and 2.1 for major bleeding and 36.8 and 8.3 for MACE in HBR and non-HBR patients, respectively. Among the 4749 (85.8%) patients who survived and collected a P2Y12 inhibitor ≤7 days from discharge, 68.2% of HBR patients were treated with ticagrelor or prasugrel and 31.8% with clopidogrel, while 18.2% non-HBR patients were treated with clopidogrel. Adherence was high for all (>75% days coverage). The risk of MACE was lower in ticagrelor- and prasugrel-treated patients than in clopidogrel-treated patients without differences in major bleeding. CONCLUSION: One-third of PCI-treated all-comer patients with STEMI were at HBR according to the PRECISE-DAPT score and were more often treated with potent P2Y12 inhibitors instead of clopidogrel. Thus, ischaemic risk may be weighted over bleeding risk in STEMI patients at HBR.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Femenino , Anciano , Inhibidores de Agregación Plaquetaria/efectos adversos , Clopidogrel/efectos adversos , Clorhidrato de Prasugrel/efectos adversos , Ticagrelor/efectos adversos , Infarto del Miocardio con Elevación del ST/diagnóstico , Estudios de Cohortes , Intervención Coronaria Percutánea/efectos adversos , Hemorragia/inducido químicamente
18.
Cardiovasc Revasc Med ; 54: 41-46, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37045636

RESUMEN

BACKGROUND: The relation between the resting full cycle ratio (RFR) and fractional flow reserve (FFR) is not fully understood. This study aims to investigate the influence of coronary microvascular dysfunction, assessed by the index of microvascular resistance (IMR), on RFR compared to FFR in patients undergoing functional assessment for coronary stenosis. MATERIALS AND METHODS: Two-hundred patients with borderline stenosis underwent functional assessment of RFR, FFR, coronary flow reserve (CFR) and IMR. Retriever operator curve analysis was performed to assess the diagnostic value of RFR in patients with (IMR ≥ 24) and (IMR < 24). RESULTS: Median RFR did not differ significantly in patients with IMR ≥ 24 compared to patients with IMR < 24: 0.89 (interquartile range (IQR) 0.84, 0.95) vs. 0.90 (IQR 0.84, 0.92), p = 0.29). FFR was significantly higher in patients with IMR ≥ 24 compared to patients with IMR < 24: median FFR 0.85 (IQR (0.76, 0.92)) vs. 0.82 (IQR 0.73, 0.86), p = 0.009, and median CFR was significantly lower 1.80 (IQR 1.40, 2.55) vs. 2.70 (IQR 1.80, 3.95), p < 0.001. The diagnostic value of RFR was high (Area under the curve (AUC) 0.89 95 % Confidence Interval: [0.85, 0.93]) and AUC did not differ between patients with IMR ≥ 24 compared to patients with IMR < 24: 0.89 vs. 0.90, p = 0.89. An overall optimal cut off of 0.88 was identified. The cut off did not differ significantly between patients with IMR ≥ 24 compared to patients with IMR < 24: 0.88 vs. 0.90, p = 0.397. CONCLUSION: In patients with coronary borderline stenosis, the coronary microvascular function did not influence on the cut off values or AUC of RFR compared to FFR.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Constricción Patológica , Angiografía Coronaria , Microcirculación , Resistencia Vascular , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas , Estenosis Coronaria/diagnóstico por imagen , Cateterismo Cardíaco
19.
Circ Cardiovasc Interv ; 16(1): e012332, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36649389

RESUMEN

BACKGROUND: Biodegradable polymer drug-eluting stents were developed to improve safety and efficacy outcomes for patients undergoing percutaneous coronary intervention. However, few long-term follow-up efficacy studies are available. The study sought to investigate 5-year results from the SORT OUT VII trial (Scandinavian Organization for Randomized Trials With Clinical Outcome) comparing the biodegradable polymer ultrathin-strut sirolimus-eluting Orsiro stent (O-SES) versus the biodegradable polymer biolimus-eluting Nobori stent (N-BES). METHODS: This registry-based, randomized, multicenter, single-blinded, noninferiority trial compared O-SES and N-BES in an all-comer population. The composite primary end point, target lesion failure, consisted of cardiac death, myocardial infarction related to the target lesion, or target lesion revascularization within 1 year. Follow-up was extended to 5 years. RESULTS: Five-year follow-up was completed for 2521 patients (99.8%). Five-year target lesion failure did not differ between O-SES (12.4%) and N-BES (13.1%; rate ratio [RR], 0.94 [95% CI, 0.75-1.18]). Cardiac death (RR, 0.95 [95% CI, 0.67-1.34]), target myocardial infarction (RR, 1.14 [95% CI, 0.76-1.71]), target lesion revascularization (RR, 0.90 [95% CI, 0.67-1.21]), and definite stent thrombosis rates (RR, 0.73 [95% CI, 0.41-1.33]) did not differ significantly between the 2 stents. Within the first year, definite ST was significantly lower for O-SES (0.4%) compared to N-BES (1.2%; RR, 0.33 [95% CI, 0.12-0.92]), but no difference was from 1 through 5 years: O-SES 1.2% and N-BES 0.9% (RR, 1.28 [95% CI, 0.58-2.82]). CONCLUSIONS: Five years after treatment with biodegradable polymer stents, target lesion failure did not differ among O-SES and N-BES. Definite stent thrombosis was less often seen within the first year in the O-SES but the difference was not maintained after 5 years. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT01879358.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Factores de Riesgo , Resultado del Tratamiento , Implantes Absorbibles , Infarto del Miocardio/etiología , Polímeros , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis
20.
Cardiol Res Pract ; 2023: 3197512, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37361000

RESUMEN

Background: Reversible P2Y12 inhibition can be obtained with cangrelor administered intravenously. More experience with cangrelor use in acute PCI with unknown bleeding risk is needed. Objectives: To describe real-world use of cangrelor including patient and procedure characteristics and patient outcomes. Methods: We performed a single-centre, retrospective, and observational study including all patients treated with cangrelor in relation to percutaneous coronary intervention at Aarhus University Hospital during the years 2016, 2017, and 2018. We recorded procedure indication and priority, the indications for cangrelor use, and patient outcomes within the first 48 hours after initiation of cangrelor treatment. Results: We treated 991 patients with cangrelor in the study period. Of these, 869 (87.7%) had an acute procedure priority. Among acute procedures, patients were mainly treated for STEMI (n = 723) and the remaining were treated for cardiac arrest and acute heart failure. Use of oral P2Y12 inhibitors prior to percutaneous coronary intervention was rare. Fatal bleeding events (n = 6) were only observed among patients undergoing acute procedures. Stent thrombosis was observed in two patients receiving acute treatment for STEMI. Thus, cangrelor can be used in relation to PCI under acute circumstances with advantages in terms of clinical management. The benefits and risks, in terms of patient outcomes, should ideally be assessed in randomized trials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA