Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Biomed Res Int ; 2016: 5958196, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27882326

RESUMEN

Objective. Decreased cardiac function after resuscitation from cardiac arrest (CA) results from global ischemia of the myocardium. In the evolution of postarrest myocardial dysfunction, preferential involvement of any coronary arterial territory is not known. We hypothesized that there is no preferential involvement of any coronary artery during electrical induced ventricular fibrillation (VF) in piglet model. Design. Prospective, randomized controlled study. Methods. 12 piglets were randomized to baseline and electrical induced VF. After 5 min, the animals were resuscitated according to AHA PALS guidelines. After return of spontaneous circulation (ROSC), animals were observed for an additional 4 hours prior to cardiac MRI. Data (mean ± SD) was analyzed using unpaired t-test; p value ≤ 0.05 was considered statistically significant. Results. Segmental wall motion (mm; baseline versus postarrest group) in segment 7 (left anterior descending (LAD)) was 4.68 ± 0.54 versus 3.31 ± 0.64, p = 0.0026. In segment 13, it was 3.82 ± 0.96 versus 2.58 ± 0.82, p = 0.02. In segment 14, it was 2.42 ± 0.44 versus 1.29 ± 0.99, p = 0.028. Conclusion. Postarrest myocardial dysfunction resulted in segmental wall motion defects in the LAD territory. There were no perfusion defects in the involved segments.


Asunto(s)
Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Paro Cardíaco/etiología , Paro Cardíaco/fisiopatología , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/fisiopatología , Animales , Cardiomiopatías/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Paro Cardíaco/diagnóstico , Masculino , Volumen Sistólico , Porcinos , Fibrilación Ventricular/diagnóstico
2.
Resuscitation ; 84(10): 1433-8, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23735651

RESUMEN

OBJECTIVE: To evaluate the hemodynamic effects of using an adhesive glove device (AGD) to perform active compression-decompression CPR (AGD-CPR) in conjunction with an impedance threshold device (ITD) in a pediatric cardiac arrest model. DESIGN: Controlled, randomized animal study. METHODS: In this study, 18 piglets were anesthetized, ventilated, and continuously monitored. After 3min of untreated ventricular fibrillation, animals were randomized (6/group) to receive either standard CPR (S-CPR), active compression-decompression CPR via adhesive glove device (AGD-CPR) or AGD-CPR along with an ITD (AGD-CPR+ITD) for 2min at 100-120compressions/min. AGD is delivered using a fingerless leather glove with a Velcro patch on the palmer aspect and the counter Velcro patch adhered to the pig's chest. Data (mean±SD) were analyzed using one-way ANOVA with pair wise multiple comparisons to assess differences between groups. p-Value≤0.05 was considered significant. RESULTS: Both AGD-CPR and AGD-CPR+ITD groups produced lower intrathoracic pressure (IttP, mmHg) during decompression phase (-13.4±6.7, p=0.01 and -11.9±6.5, p=0.01, respectively) in comparison to S-CPR (-0.3±4.2). Carotid blood flow (CBF, % of baseline mL/min) was higher in AGD-CPR and AGD-CPR+ITD (respectively 64.3±47.3%, p=0.03 and 67.5±33.1%, p=0.04) as compared with S-CPR (29.1±12.5%). Coronary perfusion pressure (CPP, mmHg) was higher in AGD-CPR and AGD-CPR+ITD (respectively 19.7±4.6, p=0.04 and 25.6±12.1, p=0.02) when compared to S-CPR (9.6±9.1). There was no statistically significant difference between AGD-CPR and AGD-CPR+ITD groups with reference to intra-thoracic pressure, carotid blood flow and coronary perfusion pressure. CONCLUSION: Active compression decompression delivered by this simple and inexpensive adhesive glove device resulted in improved cerebral blood flow and coronary perfusion pressure. There was no statistically significant added effect of ITD use along with AGD-CPR on the decompression of the chest.


Asunto(s)
Reanimación Cardiopulmonar/instrumentación , Reanimación Cardiopulmonar/métodos , Adhesivos , Animales , Descompresión , Impedancia Eléctrica , Femenino , Guantes Quirúrgicos , Hemodinámica , Masculino , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA