Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Neth Heart J ; 32(7-8): 270-275, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38653922

RESUMEN

BACKGROUND: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking. TRIAL DESIGN: The TAVI XS trial is a multicentre, randomised, open-label clinical trial with blinded evaluation of endpoints. A total of 238 patients undergoing transfemoral TAVI will be included. The primary endpoint is the incidence of clinically relevant bleeding (i.e. Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding) of the randomised secondary access site (either diagnostic or pacemaker access, or both) within 30 days after TAVI. Secondary endpoints include time to mobilisation after TAVI, duration of hospitalisation, any BARC type 2, 3 or 5 bleeding, and early safety at 30 days according to Valve Academic Research Consortium­3 criteria. CONCLUSION: The TAVI XS trial is the first randomised trial comparing an upper extremity approach to a lower extremity approach with regard to clinically relevant secondary access site-related bleeding complications. The results of this trial will provide important insights into the safety and efficacy of an upper extremity approach in patients undergoing transfemoral TAVI.

2.
J Card Surg ; 36(1): 48-55, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33084121

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The coronavirus disease 2019 (COVID-19) pandemic has put an enormous strain on healthcare systems and intensive care unit (ICU) capacity, leading to suspension of most elective procedures, including transcatheter aortic valve replacement (TAVR). However, deferment of TAVR is associated with significant wait-time mortality in patients with severe aortic valve stenosis. Conversely, there is currently no data available regarding the safety and feasibility of a continued TAVR program during this unprecedented crisis. The aim of this study is to evaluate the safety and feasibility of patients undergoing TAVR during the COVID-19 pandemic in our center, with specific emphasis on COVID-19 related outcomes. METHODS: All patients who underwent TAVR in our center between February 27, 2020, and June 30, 2020, were evaluated. Clinical outcomes were described in terms of Valve Academic Research Consortium 2 definitions. Patient follow-up was done by chart review and telephone survey. RESULTS: A total of 71 patients have undergone TAVR during the study period. Median age was 80 years, 63% were men, and 25% were inpatients. Procedural success was 99%. After TAVR, 30% involved admission to the ICU, and 94% were ultimately discharged to the cardiac care unit on the same day. Two patients (3%) had confirmed COVID-19 a few days after TAVR, and both died of COVID-19 pneumonia within 2 weeks after hospital discharge. CONCLUSIONS: A continued TAVR program during the COVID-19 pandemic is feasible despite limited hospital resources. However, COVID-19 related mortality after TAVR is of concern.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , COVID-19/epidemiología , Pandemias , SARS-CoV-2 , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Comorbilidad , Femenino , Humanos , Masculino , Países Bajos , Estudios Retrospectivos , Resultado del Tratamiento
3.
J Card Surg ; 34(3): 124-130, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30597626

RESUMEN

Spontaneous leaflet fracture of mechanical heart valve prostheses is very rare. We describe a case of spontaneous leaflet embolization 31 years after aortic valve replacement with an Edwards-Duromedics prosthesis (Baxter Healthcare Corp., Edwards Division, Santa Ana, CA). We review the literature on this subject to increase awareness and recognition for this potentially life-threatening complication.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis/efectos adversos , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Bioprótesis , Urgencias Médicas , Endocarditis/cirugía , Humanos , Masculino , Persona de Mediana Edad , Choque Cardiogénico/etiología , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/cirugía
4.
Artículo en Inglés | MEDLINE | ID: mdl-38376439

RESUMEN

This case report is a step-by-step description of the surgical treatment of a giant right coronary aneurysm with a maximum diameter of 80 mm in a 57-year-old male.


Asunto(s)
Aneurisma Coronario , Masculino , Humanos , Persona de Mediana Edad , Aneurisma Coronario/diagnóstico , Aneurisma Coronario/cirugía
5.
J Clin Med ; 13(3)2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38337345

RESUMEN

Background The femoral vein is commonly used as a pacemaker access site during transcatheter aortic valve replacement (TAVR). Using an upper arm vein as an alternative access site potentially causes fewer bleeding complications and shorter time to mobilization. We aimed to assess the safety and efficacy of an upper arm vein as a temporary pacemaker access site during TAVR. Methods We evaluated all patients undergoing TAVR in our center between January 2020 and January 2023. Upper arm, femoral, and jugular vein pacemaker access was used in 255 (45.8%), 191 (34.3%), and 111 (19.9%) patients, respectively. Clinical outcomes were analyzed according to pacemaker access in the overall population and in a propensity-matched population involving 165 upper arm and 165 femoral vein patients. Primary endpoint was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 pacemaker access site-related bleeding. Results In the overall population, primary endpoint was lowest for upper arm, followed by femoral and jugular vein access (2.4% vs. 5.8% vs. 10.8%, p = 0.003). Time to mobilization was significantly longer (p < 0.001) in the jugular cohort compared with the other cohorts. In the propensity-matched cohort, primary endpoint showed a trend toward lower occurrence in the upper arm compared with the femoral cohort (2.4% vs. 6.1%, p = 0.10). Time to mobilization was significantly shorter (480 vs. 1140 min, p < 0.001) in the upper arm cohort, with a comparable skin-to-skin time (83 vs. 85 min, p = 0.75). Cross-over from upper arm pacemaker access was required in 17 patients (6.3% of attempted cases via an upper arm vein). Conclusions Using an upper arm vein as a temporary pacemaker access site is safe and feasible. Its use might be associated with fewer bleeding complications and shorter time to mobilization compared with the femoral vein.

6.
J Cardiothorac Surg ; 18(1): 289, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37828603

RESUMEN

BACKGROUND: Aortic mycotic aneurysms are a rare but life-threatening condition and may be associated with aorto-bronchial- and aorto-esophageal fistulas. Although both very rare, they carry a high mortality and require (urgent) surgical intervention. Surviving all three conditions concomitantly is extraordinary. We describe a patient who underwent staged repair of such combined defects.


Asunto(s)
Aneurisma Infectado , Enfermedades de la Aorta , Fístula Esofágica , Humanos , Aneurisma Infectado/diagnóstico por imagen , Aneurisma Infectado/cirugía , Enfermedades de la Aorta/cirugía , Fístula Esofágica/diagnóstico , Fístula Esofágica/cirugía
7.
Eur Heart J Cardiovasc Imaging ; 24(8): 1072-1081, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-36915984

RESUMEN

AIMS: Paravalvular regurgitation (PVR) is a common complication after transcatheter aortic valve replacement (TAVR) that poses an increased risk of rehospitalization for heart failure and mortality. The aim of this study was to assess the accuracy of haemodynamic indices to predict relevant PVR. METHODS AND RESULTS: In this prospective single-centre clinical trial, four haemodynamic indices of PVR measured during TAVR were assessed for their correlation with gold standard cardiac magnetic resonance (CMR)-derived regurgitant fraction (CMR-RF) at 1 month follow-up: diastolic delta (DD), heart rate-adjusted diastolic delta (HR-DD), aortic regurgitation index (ARI), and aortic regurgitation index ratio (ARI ratio). These haemodynamic indices were analysed for their ability to predict relevant PVR (defined as CMR-RF > 20%) using receiver operating characteristic (ROC) curves with corresponding area under the ROC curves (AUCs). A total of 77 patients were included and had CMR performed 41 ± 14 days after TAVR. Mean CMR-RF was 12.4 ± 9.3%. Fifteen (19.5%) patients had CMR-RF > 20%. DD had the best correlation with CMR-RF and the highest AUC to predict relevant PVR (0.82; 95% CI, 0.72-0.92), followed by HR-DD (AUC 0.78; 95% CI, 0.67-0.89), ARI (AUC 0.78; 95% CI, 0.66-0.89), and ARI ratio (AUC 0.65; 95% CI, 0.49-0.81). The optimal cut-off value for DD was 32 mmHg, with sensitivity of 69% and specificity of 77% in predicting relevant PVR. CONCLUSION: DD measured during TAVR best predicts relevant PVR. Correction for heart rate (HR-DD) or systolic blood pressure (ARI, ARI ratio) did not improve this predictive value.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Espectroscopía de Resonancia Magnética/efectos adversos , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
8.
Semin Thorac Cardiovasc Surg ; 33(4): 923-930, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33242614

RESUMEN

Grading paravalvular leak (PVL) at the time of transcatheter aortic valve implantation (TAVI) deployment is challenging. Per-procedural invasive hemodynamic measurements could serve to optimize PVL grading and predict outcome after TAVI. The aim of this study was to compare hemodynamic measures of paravalvular leak and their prognostic relevance in self-expanding TAVI devices. Between December 2008 and December 2017 consecutive patients treated for severe symptomatic aortic valve stenosis with self-expanding devices were prospectively studied. Peri-procedural hemodynamic measurements, echocardiographic data as well as clinical follow-up according to VARC-2 criteria were prospectively collected. Diastolic delta (DD), heart rate adjusted DD, aortic regurgitation index (ARI) and ARI ratio were calculated and assessed for their association with 1-year mortality. A total of 651 patients were studied. Moderate or severe paravalvular leakage was found in 4.8% of patients. ARI ratio < 0.6 (hazard ratio 1.96 [1.23-3.12], P = 0.005) was the best independent predictor of 1-year mortality. This study confirms the value of hemodynamic measures, specifically ARI ratio, for prognostication, potentially supporting procedural decision-making with regard to PVL.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
9.
EuroIntervention ; 15(15): e1325-e1331, 2020 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-31532395

RESUMEN

AIMS: Vascular complications are among the most commonly observed complications after TAVI. Iliofemoral vascular outcome has been described extensively. Little is known about vascular complications in transaxillary TAVI. The aim of the current study was to describe the incidence and predictors of axillary artery complications incorporating computed tomography angiography (CTA) measurements. METHODS AND RESULTS: CT analysis was performed in two hundred patients treated with transaxillary TAVI in our centre between January 2014 and December 2017. Vascular complications occurred in 37 (18.5%) patients. Patient characteristics predicting this outcome were female gender (aOR 3.88 [1.48-10.14], p=0.006) and age (aOR 1.08 [1.01-1.16], p=0.034). The CTA measurement predicting vascular complications was a sheath to artery area ratio (SAAR) equal to or larger than 1.63 (OR 3.95 [1.29-12.12], p=0.016). CONCLUSIONS: The present study describes the incidence of axillary artery complications and identifies patient characteristics associated with this outcome. CTA analysis was shown to be an important screening tool in the assessment of patient (access) eligibility. Axillary artery dimensional screening should be based on vascular luminal area assessment rather than diameter measurement alone.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Arteria Axilar , Femenino , Arteria Femoral , Humanos , Incidencia , Resultado del Tratamiento
10.
Ann Thorac Surg ; 107(2): 546-552, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30292844

RESUMEN

BACKGROUND: The femoral artery is generally used as primary access for transcatheter aortic valve implantation. However, peripheral artery disease often precludes femoral access. The purpose of this study was to describe clinical outcome of transcatheter aortic valve implantation using the left axillary artery (LAA) as primary access site. METHODS: From December 2008 until June 2016, data on all consecutive patients treated with a Medtronic device through the LAA at our hospital were registered, and outcome was prospectively collected according to the updated Valve Academic Research Consortium-2 criteria. Mortality check was performed nationally. RESULTS: In total, 362 patients were included (median age 80 years [range, 76 to 84]; logistic European System for Cardiac Operative Risk Evaluation 17% ± 12%). Successful axillary access was achieved in 99%. Medtronic CoreValve (86%) and Evolut R (14% [Medtronic, Minneapolis, MN]) were implanted. Major vascular complications occurred in 5% of patients, 1% was LAA related. Life-threatening bleeding and major bleeding were observed in 2% and 10%, respectively. Additional complications were new left bundle branch blood (30%), new permanent pacemaker (11%), and stroke (1%). There were 6 procedural deaths (2%) and 19 deaths (5%) within 30 days. One-year mortality rate was 19%. CONCLUSIONS: This is the first study reporting outcome after transcatheter aortic valve implantation using the LAA as default access. We conclude that it is highly feasible and safe with low rates of major vascular complications, bleeding, and stroke.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Arteria Axilar , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
11.
J Am Geriatr Soc ; 67(11): 2325-2330, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31342524

RESUMEN

BACKGROUND/OBJECTIVES: Prospectively collected data on postoperative delirium (POD) after transcatheter aortic valve implantation (TAVI) are scarce. The aim of this study was to report the incidence and risk factors of delirium after TAVI under general anesthesia and to assess the association of POD with clinical outcome and short- and long-term survival. DESIGN: Prospective cohort study. SETTING: Academic medical center. PARTICIPANTS: A total of 703 subsequent patients undergoing TAVI under general anesthesia between 2008 and 2017. MEASUREMENTS: Delirium was assessed according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), criteria. Outcomes were postprocedural clinical outcome and short- and long-term survival (30 days and 5 years, respectively). RESULTS: POD was observed in 16.5% (116/703), was the strongest independent predictor of long-term mortality (hazard ratio = 1.91; 95% confidence interval [CI] = 1.36-2.70), and was associated with impaired 30-day and 5-year survival (92.2% vs 96.8% [P = .025] and 40.0% vs 50.0% [P = .007], respectively). Stroke and new onset of atrial fibrillation were more often observed in delirious patients (6.9% vs 1.9% and 12.1% vs 5.1%, respectively). Strongest independent predictors of POD were prior delirium (odds ratio [OR] = 2.56; 95% CI = 1.52-4.31) and aortic valve area less than 0.75 cm2 (OR = 2.39; 95% CI = 1.53-3.74). CONCLUSION: One in six patients experienced POD after TAVI under general anesthesia. POD was the strongest predictor of long-term mortality and was associated with impaired short- and long-term survival. Prior delirium and a more calcified aortic valve were the strongest independent predictors of POD. J Am Geriatr Soc 67:2325-2330, 2019.


Asunto(s)
Anestesia General/efectos adversos , Delirio/epidemiología , Evaluación Geriátrica/métodos , Complicaciones Posoperatorias , Medición de Riesgo/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Países Bajos/epidemiología , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo
12.
Open Heart ; 3(2): e000478, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28008356

RESUMEN

OBJECTIVE: We hypothesised that frailty assessment is of additional value to predict delirium and mortality after transcatheter aortic valve implantation (TAVI). METHODS: Observational study in 89 consecutive patients who underwent TAVI. Inclusion from November 2012 to February 2014, follow-up until April 2014. Measurement of the association of variables from frailty assessment and cardiological assessment with delirium and mortality after TAVI, respectively. RESULTS: Incidence of delirium after TAVI: 25/89 (28%). Variables from frailty assessment protectively associated with delirium were: Mini Mental State Examination, (OR 0.79; 95% CI 0.65 to 0.96; p=0.02), Instrumental Activities of Daily Living (OR 0.79; 95% CI 0.63 to 0.99; p=0.04) and gait speed (OR 0.05; 95% CI 0.01 to 0.50; p=0.01). Timed Up and Go was predictively associated with delirium (OR 1.14; 95% CI 1.03 to 1.26; p=0.01). From cardiological assessment, pulmonary hypertension was protectively associated with delirium (OR 0.34; 95% CI 0.12 to 0.98; p=0.05). Multivariate logistic analysis: Nagelkerke R2=0.359, Mini Mental State Examination was independently associated with delirium. Incidence of mortality: 11/89 (12%). Variables predictively associated with mortality were: the summary score Frailty Index (HR 1.66, 95% CI 1.06 to 2.60; p=0.03), European System for Cardiac Operative Risk Evaluation (EuroSCORE) II (HR 1.14, 95% CI 1.06 to 1.22; p<0.001) and complications (HR 4.81, 95% CI 1.03 to 22.38; p=0.05). Multivariate Cox proportional hazards analysis: Nagelkerke R2=0.271, Frailty Index and EuroSCORE II were independently associated with mortality. CONCLUSIONS: Delirium frequently occurs after TAVI. Variables from frailty assessment are associated with delirium and mortality, independent of cardiological assessment. Thus, frailty assessment may have additional value in the prediction of delirium and mortality after TAVI.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA