Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Surg Endosc ; 35(8): 4085-4094, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33948714

RESUMEN

BACKGROUND AND AIMS: Pain is one of the consequences of chronic pancreatitis (CP) that has the greatest impact on the quality of life of patients. Endoscopic and surgical interventions, by producing a decrease in intraductal pancreatic pressure, can provide pain relief. This is the first systematic review that includes only randomized clinical trials (RTCs) comparing outcomes in the short-term (less than 2 years) and long-term (more than 2 years) between these two types of interventions. MATERIAL AND METHODS: A comprehensive search of multiple electronic databases to identify RTCs comparing short and long-term pain relief, procedural complications, and days of hospitalization between endoscopic and surgical interventions was performed following the PRISMA guidelines. RESULTS: Three RCTs evaluating a total of 199 patients (99 in the endoscopy group and 100 in the surgery group) were included in this study. Surgical interventions provided complete pain relief, with statistical difference, in the long-term (16,4% vs 35.7%; RD 0.19; 95% CI 0.03-0.35; p = 0.02; I2 = 0%), without significant difference in short-term (17.5% vs 31.2%; RD 0.14; 95% CI -0.01-0.28; p = 0.07; I2 = 0%) when compared to endoscopy. There was no statistical difference in short-term (17.5% vs 28.1%; RD 0.11; 95% CI -0.04-0.25; p = 0.15; I2 = 0%) and long-term (34% vs 41.1%; RD 0.07; 95% CI -0.10-0.24; p = 0.42; I2 0%) in partial relief of pain between both interventions. In the short-term, both complications (34.9% vs 29.7%; RD 0.05; 95% CI -0.10-0.21; p = 0.50; I2 = 48%) and days of hospitalization (MD -1.02; 95% CI -2.61-0.58; p = 0.21; I2 = 0%) showed no significant differences. CONCLUSION: Surgical interventions showed superior results when compared to endoscopy in terms of complete long-term pain relief. The number of complications and length of hospitalization in both groups were similar.


Asunto(s)
Pancreatitis Crónica , Calidad de Vida , Endoscopía , Humanos , Dolor , Manejo del Dolor , Pancreatitis Crónica/complicaciones , Pancreatitis Crónica/cirugía
3.
Acta Cir Bras ; 35(2): e202000206, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32348403

RESUMEN

Purpose To present new endoscopic robotic devices in the context of minimally invasive procedures with high precision and automation. Methods Review of the literature by December 2018 on robotic endoscopy. Results We present the studies and investments for robotic implementation and flexible endoscopy evolution. We divided them into forceps manipulation platforms, active endoscopy and endoscopic capsule. They try to improve forceps handling and stability and to promote active movement. Conclusion The implementation and propagation of robotic models depend on doing what the endoscopist is unable to. The new devices are moving forward in this direction.


Asunto(s)
Endoscopía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Animales , Endoscopios/clasificación , Resección Endoscópica de la Mucosa/instrumentación , Resección Endoscópica de la Mucosa/métodos , Diseño de Equipo , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Modelos Animales , Procedimientos Quirúrgicos Robotizados/instrumentación , Cirugía Asistida por Computador/instrumentación , Instrumentos Quirúrgicos
4.
Arq Gastroenterol ; 57(2): 154-160, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32609157

RESUMEN

BACKGROUND: It has been proposed that the combination of gastrin-17 (G-17), pepsinogens I and II (PGI and PGII), and anti-Helicobacter pylori (H. pylori) antibodies (GastroPanel®, BIOHIT HealthCare, Helsinki, Finland) could serve as biomarkers of atrophic gastritis. OBJECTIVE: This study aimed to ensure the diagnostic accuracy of GastroPanel® and evaluate the effect of proton pump inhibitors (PPIs) on these biomarkers. METHODS: Dyspeptic patients who underwent gastrointestinal endoscopy were enrolled in the present study. Histological findings, which were the gold standard to stratify groups, were as follows: no atrophy (controls); antrum atrophy; corpus atrophy; multifocal atrophy; and neoplasia. G-17, PGI, PGII, and anti-H. pylori immunoglobulin (Ig)G antibodies were assayed using commercially available kits. The ratio of PGI/PGII was calculated. RESULTS: Among 308 patients, 159 (51.6%) were PPI users. The overall prevalence of atrophy was 43.8% (n=135). Ninety-two (29.9%) patients were H. pylori positive according to anti-H. pylori IgG levels. G-17 levels were not low in those with antrum atrophy but were high in those with corpus and multifocal atrophies. PGI levels were significantly lower in those with corpus and multifocal atrophies. The sensitivity of PGI <30 µg/L to detect corpus atrophy was 50% (95% CI 27.8-72.1%), with a specificity of 93.2% (95% CI 84.3-97.5%), a positive likelihood ratio of 7.4 (95% CI 2.9-19.2), and a negative likelihood ratio of 0.5 (95% CI 0.3-0.8). A small number of subjects (n=6) exhibited moderate to intense atrophy (4%), among whom 66.7% exhibited decreased PGI levels. PPI significantly increased the levels of G-17 and PGI, except in those with corpus and multifocal atrophies, in whom PGI levels were not increased by PPIs. CONCLUSION: GastroPanel® (Gastrin-17, PGI, and PGI/PGII ratio) did not demonstrate high sensitivity for detecting gastric atrophy.


Asunto(s)
Gastritis Atrófica/diagnóstico , Inhibidores de la Bomba de Protones , Anticuerpos Antibacterianos , Brasil , Infecciones por Helicobacter , Helicobacter pylori , Humanos
5.
Endosc Int Open ; 6(8): E914-E923, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30258982

RESUMEN

Background and study aims The first-line approach to anastomotic biliary stricture after orthotopic liver transplantation (OLTX) involves endoscopic retrograde cholangiopancreatography (ERCP). The most widely used technique is placement of multiple plastic stents, but discussions are ongoing on the benefits of fully-covered self-expandable metallic stents (FCEMS) in this situation. This study aimed to compare results from use of plastic and metal stents to treat biliary stricture after transplantation. Patients and methods Searches were performed in the Medline, EMBASE, SciELO/LILACS, and Cochrane databases, and only randomized studies comparing the two techniques were included in the meta-analysis. Results Our study included four randomized clinical trials totaling 205 patients. No difference was observed between the stricture resolution rate (RD: 0.01; 95 %CI [-0.08 - 0.10]), stricture recurrence (RD: 0.13; 95 %CI [-0.03 - 0.28]), and adverse events (RD: -0.10; 95 %CI [-0.65 - 0.44]) between the plastic and metallic stent groups. The metallic stent group demonstrated benefits in relation to the number of ERCPs performed (MD: -1.86; 95 %CI [-3.12 to -0.6]), duration of treatment (MD: -105.07; 95 %CI [-202.38 to -7.76 days]), number of stents used (MD: -10.633; 95 %CI [-20.82 to -0.44]), and cost (average $ 8,288.50 versus $ 18,580.00, P  < 0.001). Conclusions Rates of resolution and recurrence of stricture are similar, whereas the number of ERCPs performed, number of stents used, duration of treatment, and costs were lower in patients treated with FCEMS, which shows that this device is a valid option for initial treatment of post-OLTX biliary stricture.

7.
Endosc Int Open ; 6(5): E558-E567, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29756013

RESUMEN

BACKGROUND AND STUDY AIMS: Colorectal cancer (CRC) is the third most common malignancy and the third leading cause of cancer death worldwide. Malignant colonic obstruction (MCO) due to CRC occurs in 8 % to 29 % of patients.The aim of this study was to perform a systematic review and meta-analysis of RCTs comparing colonic SEMS versus emergency surgery (ES) for MCO in palliative patients. This was the first systematic review that included only randomized controlled trials in the palliative setting. METHODS: A literature search was performed according to the PRISMA method using online databases with no restriction regarding idiom or year of publication. Data were extracted by two authors according to a predefined data extraction form. Primary outcomes were: mean survival, 30-day adverse events, 30-day mortality and length of hospital stay. Stoma formation, length of stay on intensive care unit (ICU), technical success and clinical success were recorded for secondary outcomes. Technical success (TS) was defined as successful stent placement across the stricture and its deployment. Clinical success (CS) was defined as adequate bowel decompression within 48 h of stent insertion without need for re-intervention. RESULTS: We analyzed data from four RCT studies totaling 125 patients. The 30-day mortality was 6.3 % for SEMS-treated patients and 6.4 % for ES-treated patients, with no difference between groups (RD: - 0.00, 95 % CI [-0.10, 0.10], I 2 : 0 %). Mean survival was 279 days for SEMS and 244 days for ES, with no significant difference between groups (RD: 20.14, 95 % CI: [-42.92, 83.21], I 2 : 44 %). Clinical success was 96 % in the ES group and 86.1 % in the SEMS group (RD: - 0.13, 95 % CI [-0.23, - 0.02], I 2 : 51 %). Permanent stoma rate was 84 % in the ES group and 14.3 % in the SEMS group (RR: 0.19, 95 % CI: [0.11, 0.33], I 2 : 28 %). Length of hospital stay was shorter in SEMS group (RD: - 5.16, 95 % CI: [-6.71, - 3.61], I 2 : 56 %). There was no significant difference between groups regarding adverse events (RD 0.18, 95 % CI: [-0.19, 0.54;]) neither regarding ICU stay. (RD: - 0.01, 95 % CI: [-0.08, 0.05], I 2 : 7 %). The most common stent-related complication was perforation (42.8 % of all AE). CONCLUSION: Mortality, mean survival, length of stay in the ICU and early complications of both methods were similar. SEMS may be an alternative to surgery with the advantage of early hospital discharge and lower risk of permanent stoma.

8.
Arq. gastroenterol ; 57(2): 154-160, Apr.-June 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1131649

RESUMEN

ABSTRACT BACKGROUND: It has been proposed that the combination of gastrin-17 (G-17), pepsinogens I and II (PGI and PGII), and anti-Helicobacter pylori (H. pylori) antibodies (GastroPanel®, BIOHIT HealthCare, Helsinki, Finland) could serve as biomarkers of atrophic gastritis. OBJECTIVE: This study aimed to ensure the diagnostic accuracy of GastroPanel® and evaluate the effect of proton pump inhibitors (PPIs) on these biomarkers. METHODS: Dyspeptic patients who underwent gastrointestinal endoscopy were enrolled in the present study. Histological findings, which were the gold standard to stratify groups, were as follows: no atrophy (controls); antrum atrophy; corpus atrophy; multifocal atrophy; and neoplasia. G-17, PGI, PGII, and anti-H. pylori immunoglobulin (Ig)G antibodies were assayed using commercially available kits. The ratio of PGI/PGII was calculated. RESULTS: Among 308 patients, 159 (51.6%) were PPI users. The overall prevalence of atrophy was 43.8% (n=135). Ninety-two (29.9%) patients were H. pylori positive according to anti-H. pylori IgG levels. G-17 levels were not low in those with antrum atrophy but were high in those with corpus and multifocal atrophies. PGI levels were significantly lower in those with corpus and multifocal atrophies. The sensitivity of PGI <30 µg/L to detect corpus atrophy was 50% (95% CI 27.8-72.1%), with a specificity of 93.2% (95% CI 84.3-97.5%), a positive likelihood ratio of 7.4 (95% CI 2.9-19.2), and a negative likelihood ratio of 0.5 (95% CI 0.3-0.8). A small number of subjects (n=6) exhibited moderate to intense atrophy (4%), among whom 66.7% exhibited decreased PGI levels. PPI significantly increased the levels of G-17 and PGI, except in those with corpus and multifocal atrophies, in whom PGI levels were not increased by PPIs. CONCLUSION: GastroPanel® (Gastrin-17, PGI, and PGI/PGII ratio) did not demonstrate high sensitivity for detecting gastric atrophy.


RESUMO CONTEXTO: Foi proposto que a combinação de gastrina 17 (G-17), pepsinogênios I e II (PGI e PGII), e anticorpos anti-Helicobacter pylori (H. pylori) (GastroPanel®, BIOHIT HealthCare), poderiam indicar gastrite atrófica. OBJETIVO: Portanto, o objetivo foi averiguar a acurácia diagnóstica do painel gástrico e avaliar o efeito dos inibidores de bomba de prótons (IBP) nesses marcadores. MÉTODOS: Pacientes dispépticos que se submeteram à endoscopia gastrointestinal entraram no estudo. Os achados histológicos foram o padrão ouro para estratificar os grupos: sem atrofia (controles), atrofia de antro, atrofia de corpo, atrofia multifocal e neoplasia. G-17, PGI, PGII, e anticorpos IgG anti-H. pylori foram determinados por kits comerciais. A razão PGI/PGII foi calculada. RESULTADOS: Entre 308 pacientes que foram incluídos, 159 estavam usando IBP (51,6%). A prevalência de atrofia foi de 43,8% (135 pacientes). H. pylori foi positivo em 92 (29,9%) pacientes por IgG anti-H. pylori. G-17 não estava diminuída na atrofia do antro, mas estava elevada nas atrofias do corpo e multifocal. PGI estava significantemente menor nas atrofias de corpo e multifocal. A sensibilidade da PGI <30 µg/L de indicar atrofia do corpo foi 50% (95%IC 27,8-72,1%) com especificidade de 93,2% (95%IC 84,3-97,5%), razão de verossimilhança positiva de 7,4 (95%IC 2,9-19,2) e razão de verossimilhança negativa de 0,5 (95%IC 0,3-0,8). O número de indivíduos com atrofia moderada para intensa foi pequeno (n=6;4%), dos quais 66,7% tinham diminuição dos níveis de PGI. IBP significantemente aumentou os níveis de G-17 e PGI, exceto nas atrofias de corpo e multifocal que não apresentaram aumento de PGI. CONCLUSÃO: O painel gástrico não teve alta sensibilidade de indicar gastrite atrófica.


Asunto(s)
Humanos , Inhibidores de la Bomba de Protones , Gastritis Atrófica/diagnóstico , Brasil , Helicobacter pylori , Infecciones por Helicobacter , Anticuerpos Antibacterianos
9.
Acta cir. bras ; 35(2): e202000206, 2020. graf
Artículo en Inglés | LILACS | ID: biblio-1100883

RESUMEN

Abstract Purpose To present new endoscopic robotic devices in the context of minimally invasive procedures with high precision and automation. Methods Review of the literature by December 2018 on robotic endoscopy. Results We present the studies and investments for robotic implementation and flexible endoscopy evolution. We divided them into forceps manipulation platforms, active endoscopy and endoscopic capsule. They try to improve forceps handling and stability and to promote active movement. Conclusion The implementation and propagation of robotic models depend on doing what the endoscopist is unable to. The new devices are moving forward in this direction.


Asunto(s)
Endoscopía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Instrumentos Quirúrgicos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Endoscopios/clasificación , Modelos Animales , Cirugía Asistida por Computador/instrumentación , Diseño de Equipo , Procedimientos Quirúrgicos Robotizados/instrumentación , Resección Endoscópica de la Mucosa/instrumentación , Resección Endoscópica de la Mucosa/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA