1.
J Heart Valve Dis ; 25(3): 289-295, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27989038

RESUMEN

BACKGROUND: The echocardiographic grading of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) severity is challenging. The study aim was to assess the value of quantitative Doppler echocardiography to monitor PVL severity. METHODS: A total of 100 subjects was enrolled in the study, including 65 consecutive patients who had undergone TAVI with a CoreValve prosthesis and without valvular aortic regurgitation, and 35 normal controls. The PVL volume was calculated using the quantitative Doppler method as the difference of left and right ventricular stroke volume (SV). PVL severity was assessed both visually and quantitatively as the circumferential extent on a short-axis view (SAX). RESULTS: The inter-observer variabilities for SVs in TAVI patients were disappointing: 14 ± 11% for the left ventricular SV and 18 ± 14% for right ventricular SV. The correlation (r2) between the averaged regurgitant PVL volume and circumferential SAX extent of PVL was 0.02 (p = NS). The relationship between PVL volumes and categories, defined quantitatively by the circumferential SAX extent of PVL and qualitatively by visual assessment of severity of PVL were poor. The results improved when only patients with optimal quality images were included but were still statistically non-significant. CONCLUSIONS: The relationship between calculated PVL volume in TAVI patients and other estimates of PVL severity was poor, most likely due to intrinsic errors made in the quantitative Doppler method. Therefore, one should be prudent to include the quantitative Doppler method in TAVI patients in clinical trials and clinical decision-making, in particular in patients with reduced image quality.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía Doppler , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Adulto , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estudios de Casos y Controles , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha
2.
Cardiovasc Ultrasound ; 14(1): 37, 2016 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-27600600

RESUMEN

To make assessment of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) more uniform the second Valve Academic Research Consortium (VARC) recently updated the echocardiographic criteria for mild, moderate and severe PVL. In the VARC recommendation the assessment of the circumferential extent of PVL in the short-axis view is considered critical. In this paper we will discuss our observational data on the limitations and difficulties of this particular view, that may potentially result in overestimation or underestimation of PVL severity.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Humanos , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo
3.
Echocardiography ; 33(11): 1665-1675, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27550630

RESUMEN

AIMS: Evaluation of left ventricular (LV) myocardial deformation by speckle tracking echocardiography (STE) is useful for clinical and research purposes. However, strain measurements depend on the used software. Normative data for QLAB 10 (Philips) are scarce. Additionally, little is known about the influence of anthropometric factors. We aimed to establish normal adult STE-derived strain and strain rate values and to evaluate associations with anthropometrics. METHODS: One hundred fifty-five healthy subjects aged 20 to 72 years (≥28 subjects per decile) were prospectively gathered and examined with electrocardiography and two-dimensional echocardiography. With STE, we assessed peak systolic LV global longitudinal strain (GLS), segmental longitudinal strain, and strain rate from the three standard apical views. RESULTS: We included 147 healthy subjects (age 44.6±13.7 years, 50% female, GLS -20.8±2.0%). Men had significantly lower GLS than women (-20.1±1.8% vs -21.5±2.0%, P<.001). GLS was significantly lower in subjects with age above 55 years (P=.029), higher blood pressure (P<.001), higher body surface area (BSA, P<.001), larger LV end-systolic and end-diastolic volumes (both P<.001), lower LV ejection fraction (P<.001), and some indices of diastolic function. After multivariable regression analysis, the correlation with systolic blood pressure, E-wave, and LV end-systolic volume remained significant. The systolic strain rates of most segments correlated with BSA. CONCLUSIONS: Our study resulted in normative LV GLS values assessed with QLAB 10. Male sex, higher BSA, and higher blood pressure negatively influence GLS. Therefore, these factors should be taken into account for strain interpretation in clinical practice.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Contracción Miocárdica/fisiología , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Electrocardiografía , Femenino , Estudios de Seguimiento , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Volumen Sistólico/fisiología , Adulto Joven
4.
Echocardiography ; 33(3): 353-61, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26522441

RESUMEN

AIMS: The aim of this study was to evaluate the feasibility of transthoracic two-dimensional (2D) iRotate, a new echo modality, to assess the whole right ventricle (RV) from a single transducer position based on anatomic landmarks. METHODS AND RESULTS: The anatomic landmarks were first defined based on three-dimensional echocardiographic datasets using multiplane reconstruction analyses. Thereafter, we included 120 healthy subjects (51% male, age range 21-67 years). Using 2D iRotate, four views of the RV could be acquired based on these landmarks. The anterior, lateral, inferior wall (divided into three segments: basal-mid-apical), and right ventricular outflow tract (RVOT) anterior wall of the RV were determined. The feasibility of visualization of RV segments and tricuspid annular plane systolic excursion (TAPSE) and tissue Doppler imaging (TDI) measurements were assessed. To evaluate this model for diseased RVs, a small pilot study of 20 patients was performed. In 98% of healthy subjects and 100% of patients, iRotate mode was feasible to assess the RV from one single transducer position. In total, 86% and 95%, respectively, of the RV segments could be visualized. The visualization of the RVOT anterior wall was worse 23% and 75%, respectively. TAPSE and TDI measurements on all four views were feasible 93% and 92%, respectively, of the healthy subjects and in 100% of the patients. CONCLUSION: With 2D iRotate, a comprehensive evaluation of the entire normal and diseased RV is feasible from a fixed transducer position based on anatomic landmarks. This is less time-consuming than the multiview approach and enhances accuracy of RV evaluation. Imaging of the RVOT segment remains challenging.


Asunto(s)
Puntos Anatómicos de Referencia/diagnóstico por imagen , Ecocardiografía/métodos , Ecocardiografía/normas , Ventrículos Cardíacos/diagnóstico por imagen , Modelos Cardiovasculares , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Anciano , Simulación por Computador , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/métodos , Aumento de la Imagen/normas , Interpretación de Imagen Asistida por Computador/métodos , Interpretación de Imagen Asistida por Computador/normas , Masculino , Persona de Mediana Edad , Países Bajos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
5.
Echocardiography ; 30(3): 293-300, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23347129

RESUMEN

BACKGROUND: Angina and an electrocardiographic strain pattern are potential manifestations of subendocardial ischemia in aortic stenosis (AS). Left ventricular (LV) twist is known to increase proportionally to the severity of AS, which may be a result of loss of the inhibiting effect of the subendocardial fibers due to subendocardial dysfunction. It has also been shown that the ratio of LV twist to circumferential shortening of the endocardium (twist-to-shortening ratio [TSR]) is a reliable parameter of subendocardial dysfunction. The aim of this study was to investigate whether these markers are increased in AS patients with angina and/or electrocardiographic strain. METHODS: The study comprised 60 AS patients with an aortic valve area <2.0 cm(2) and LV ejection fraction >50%, and 30 healthy-for age and gender matched-control subjects. LV rotation parameters were determined by speckle tracking echocardiography. RESULTS: Comparison of patients without angina and strain (n = 22), with either angina or strain (n = 28), and with both angina and strain (n = 8), showed highest peak systolic LV apical rotation, peak systolic LV twist, and TSR, in patients with more signs of subendocardial ischemia. In a multivariate linear regression model, only severity of AS and the presence of angina and/or strain could be identified as independent predictors of peak systolic LV twist and TSR. CONCLUSIONS: Peak systolic LV twist and TSR are increased in AS patients and related to the severity of AS and symptoms (angina) or electrocardiographic signs (strain) compatible with subendocardial ischemia.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Diagnóstico por Imagen de Elasticidad/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Ecocardiografía/métodos , Módulo de Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Disfunción Ventricular Izquierda/etiología
6.
Echocardiography ; 30(5): 558-63, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23228071

RESUMEN

BACKGROUND: Tissue Doppler imaging (TDI) of the mitral annulus has been proposed as an alternative for the identification of hypertrophic cardiomyopathy (HCM) genetically affected subjects without left ventricular hypertrophy (G+/LVH-). Unfortunately, conflicting results have been described in the literature, potentially caused by the angle-dependency of TDI. This study sought to assess abnormalities in mitral annular velocities in G+/LVH- subjects as detected by speckle tracking echocardiography (STE). METHODS: The study population consisted of 23 consecutive genotyped family members without major or minor criteria for the diagnosis of HCM (mean age 37 ± 13 years, 9 men) and 23 healthy volunteers (age 38 ± 12 years, 12 men) who prospectively underwent STE. RESULTS: There were no significant differences in global peak systolic annular velocity (7.4 ± 1.2 vs. 7.1 ± 1.0 cm/sec) and early diastolic annular velocity (10.2 ± 2.5 vs. 11.3 ± 2.2 cm/sec) between G+/LVH- and control subjects. Global peak late diastolic annular velocity was higher in G+/LVH- subjects (8.1 ± 1.7 vs. 5.7 ± 1.1 cm/sec, P < 0.001). Regionally, this difference was seen in all 6 studied LV walls. CONCLUSIONS: This STE study confirms our previous TDI observations on increased peak late diastolic annular velocities in G+/LVH- subjects. Because of the complete overlap in early diastolic annular velocities this parameter cannot be used in the genotypes we studied to differentiate genotype (+) from genotype (-) individuals.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/genética , Heterocigoto , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Estudios de Casos y Controles , Diástole/fisiología , Ecocardiografía Doppler de Pulso/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Linaje , Fenotipo , Estudios Prospectivos , Valores de Referencia , Medición de Riesgo , Sístole/fisiología , Disfunción Ventricular Izquierda/genética , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/genética
7.
Echocardiography ; 28(5): 575-81, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21535116

RESUMEN

BACKGROUND: The wall motion score index (WMSI) is a surrogate for left ventricular ejection fraction (LV-EF), which becomes unreliable in poor echo windows. The value of contrast LV opacification (LVO) for WMSI assessment is not well known. OBJECTIVES: We sought to compare interobserver agreement for WMSI and the correlation between the LVO-WMSI and LV-EF using two-dimensional second harmonic (SH) and LVO echocardiography. METHODS: The study comprised 100 consecutive patients (57 ± 13 years, 85% males). Two independent physicians assessed LV segmental quality and wall motion for both the SH and LVO studies according to a 17-segment model. Systolic wall motion was defined as: normokinesia, hypokinesia (systolic inward endocardial motion <7 mm), akinesia, and dyskinesia. LV-EF was assessed from the LVO images according to the biplane modified Simpson's method. RESULTS: Of the 1,700 analyzed segments, 453 (26.6%) were poorly visualized with SH imaging, and 173 (10.2%) with LVO (P < 0.0001). The two observers agreed on segmental wall motion score in 1,299 segments (agreement 76%, Kappa 0.60) with SH imaging and in 1,491 segments (agreement 88%, Kappa 0.78) with LVO. Interobserver correlation (r(2) ) was 0.86 for the SH-WMSI and 0.93 for the LVO-WMSI. The limits-of-agreement for interobserver LVO-WMSI (mean difference -1.0%± 6.8%, agreement -14.6%, 12.6%) was lower than that for SH-WMSI (mean difference -2.3%± 10.1%, agreement -22.5, 17.9). The LVO-WMSI correlated well with LV-EF (r(2) = 0.71). LV-EF could be estimated according to the formula 1.01 - 0.32 × WMSI. CONCLUSION: Echo-contrast improves interobserver agreement for wall motion scoring and the WMSI. The LVO-imaged WMSI correlates well with LV-EF.


Asunto(s)
Algoritmos , Ecocardiografía/métodos , Aumento de la Imagen/métodos , Fosfolípidos , Volumen Sistólico , Hexafluoruro de Azufre , Disfunción Ventricular Izquierda/diagnóstico por imagen , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Circ J ; 74(1): 101-8, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19966501

RESUMEN

BACKGROUND: In order to gain further insight into age-associated changes of left ventricular (LV) diastolic function, the purpose of the current study was to investigate alterations in LV untwisting with ageing. METHODS AND RESULTS: The study comprised 75 healthy volunteers, classified into 3 groups: age 16-35 (n=25), 36-55 (n=25) and 56-75 (n=25) years. LV untwisting (as a percentage of peak systolic twist) at 5%, 10%, 15% and 50% of diastole, peak diastolic untwisting velocity, time-to-peak diastolic untwisting velocity and untwisting rate (mean untwisting velocity during the time interval from peak systolic twist to mitral valve opening) were assessed using speckle-tracking echocardiography. Untwisting at 5%, 10%, 15% and 50% of diastole decreased with ageing. Although the peak diastolic untwisting velocity and untwisting rate were not significantly different between the age groups, when normalized for LV peak systolic twist, these parameters decreased with advancing age (both P<0.01). Time-to-peak diastolic untwisting velocity increased with ageing (P<0.01). CONCLUSIONS: Impairment of the relative peak diastolic untwisting velocity and untwisting rate, resulting in delayed LV untwisting, may help to explain diastolic dysfunction in the elderly. (Circ J 2010; 74: 101 - 108).


Asunto(s)
Envejecimiento/fisiología , Ventrículos Cardíacos/anatomía & histología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda/fisiología , Adolescente , Adulto , Anciano , Diástole/fisiología , Ecocardiografía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Sístole/fisiología , Adulto Joven
9.
Eur J Epidemiol ; 25(7): 481-90, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20495954

RESUMEN

Insight into echocardiographic parameters in the general population may facilitate early recognition of ventricular dysfunction, reducing the population morbidity and mortality of heart failure. We examined the distribution of structural, systolic and diastolic echocardiographic parameters and their associations with cardiovascular risk factors in the Rotterdam Study, a population-based cohort study in men and women aged > or =55 years. Participants with prevalent heart failure, myocardial infarction and atrial fibrillation and flutter were excluded. Echocardiographic parameters were assessed using two-dimensional, M-mode and Doppler echocardiography. Echocardiograms were available in 4,425 participants. Structural parameters were generally larger in men, and most consistently associated with age, body mass index and blood pressure in both sexes. Prevalence of moderate or poor left ventricular systolic function was 3.9% in men and 2.1% in women. Age, body mass index and blood pressure were most consistently associated with systolic function. E/A ratio was lower in women than in men. Age and diastolic blood pressure were most consistently associated with E/A ratio in both sexes. In conclusion, ventricular systolic and diastolic dysfunction is present in asymptomatic individuals. Selected established cardiovascular risk factors are associated with structural, systolic and diastolic parameters.


Asunto(s)
Insuficiencia Cardíaca Diastólica/diagnóstico por imagen , Insuficiencia Cardíaca Diastólica/epidemiología , Insuficiencia Cardíaca Sistólica/diagnóstico por imagen , Insuficiencia Cardíaca Sistólica/epidemiología , Hipertensión/epidemiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Distribución por Edad , Índice de Masa Corporal , Femenino , Humanos , Hipercolesterolemia/epidemiología , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Prevalencia , Factores de Riesgo , Distribución por Sexo , Ultrasonografía , Disfunción Ventricular Izquierda/epidemiología , Remodelación Ventricular
10.
Echocardiography ; 27(3): 269-74, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19765059

RESUMEN

BACKGROUND: Conceptually, an ideal therapeutic agent should target the underlying mechanisms that cause left ventricular (LV) diastolic dysfunction. The objective of our study was to gain further insight into the mechanics of diastology by comparison of LV untwisting measured by speckle tracking echocardiography (STE) in young healthy adults with normal and "pseudorestrictive" LV filling, and dilated cardiomyopathy (DCM) patients with "true restrictive" LV filling. METHODS: The study comprised 20 healthy volunteers with a Doppler LV-inflow pattern compatible with restrictive LV filling but a diastolic early phase filling velocity/early diastolic velocity of the mitral annulus (E/Em) ratio <8 ("pseudorestrictive"), 20 for age and gender-matched healthy volunteers with normal LV filling and an E/Em ratio <8, and 10 DCM patients with "true restrictive" LV filling and an E/Em ratio >15. LV untwisting parameters were determined by STE. RESULTS: Compared to healthy subjects, DCM patients had decreased peak diastolic untwisting velocity (-62 +/- 33 degrees/s vs -113 +/- 25 degrees/s, P < 0.01) and untwisting rate (-15 +/- 9 degrees/s vs -51 +/- 24 degrees/s, P < 0.01). Compared to healthy subjects with normal LV filling, healthy subjects with "pseudorestrictive" LV filling had increased peak diastolic untwisting velocity (-123 +/- 25 degrees/s vs -104 +/- 30 degrees/s, P < 0.05) and untwisting rate (-59 +/- 23 degrees/s vs -44 +/- 22 degrees/s, P < 0.05). CONCLUSION: Faster LV untwisting plays a pivotal role in the rapid early diastolic filling occasionally seen in young healthy individuals. In contrast, in DCM patients untwisting is severely delayed and this impairment to utilize suction may reduce LV filling.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Diástole , Ventrículos Cardíacos/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Velocidad del Flujo Sanguíneo , Cardiomiopatía Dilatada/fisiopatología , Ecocardiografía , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Válvula Mitral/fisiopatología , Estándares de Referencia
12.
Orv Hetil ; 151(21): 854-63, 2010 May 23.
Artículo en Húngaro | MEDLINE | ID: mdl-20462845

RESUMEN

Recently, echocardiography is the most widely used routine non-invasive diagnostic method, with which morphology and function of the mitral valve can be characterized. The aim of this review is to demonstrate the role of one of the newest echocardiographic developments, the transthoracic real-time three-dimensional echocardiography in the evaluation of mitral valve.


Asunto(s)
Ecocardiografía Tridimensional , Válvula Mitral/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Humanos , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/diagnóstico por imagen
13.
Eur J Echocardiogr ; 10(5): 669-76, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19383641

RESUMEN

AIMS: This study sought to find the most robust method for left ventricular (LV) rotation measurement by speckle tracking echocardiography (STE) with the new QLAB Advanced Quantification Software (version 6.0, Philips, Best, The Netherlands). METHODS AND RESULTS: The study population consisted of 40 non-selected patients (mean age 48 +/- 18 year, 20 men) and 50 non-selected healthy volunteers (mean age 34 +/- 12 year, 21 men). Feasibility and intra-observer reproducibility of the measurement of LV rotation parameters by STE were assessed for two different methods (Method A: six tracking points placed mid-myocardial and Method B: six tracking points placed endocardial and epicardial forming six myocardial segments). Subsequently, inter-observer and temporal reproducibility of the most robust method were assessed. Complete LV rotation assessment was more feasible with Method A (60 out of 90 subjects, 67% vs. 50 out of 90 subjects, 56%). In the 49 subjects in whom both Methods A and B were feasible, intra-observer reproducibility of LV rotation parameters was better with Method A (variabilities 2 +/- 3 to 10 +/- 9% vs. 2 +/- 4 to 21 +/- 18%). With this method, inter-observer variability varied from 4 +/- 4 to 13 +/- 9% and temporal variability from 4 +/- 6 to 19 +/- 15%. CONCLUSION: The most robust method to assess LV rotation with QLAB software is from the mid-myocardium. This method is feasible in approximately two-thirds of subjects and has good intra-observer, inter-observer, and temporal reproducibility, allowing to study changes over time in LV rotation in an individual patient.


Asunto(s)
Ecocardiografía/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Análisis de Varianza , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Rotación , Programas Informáticos , Disfunción Ventricular Izquierda/fisiopatología
14.
Swiss Med Wkly ; 139(7-8): 117-20, 2009 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-19234880

RESUMEN

PRINCIPLES: MELAS, or mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes is a new distinctive clinical entity. The current study was designed to assess ascending aortic elasticity in adult patients with MELAS syndrome and in gene carriers, and to compare the results with age- and gender-matched healthy controls. METHODS: The study comprised eight patients with MELAS syndrome and four asymptomatic gene carriers. All subjects underwent complete 2-dimensional transthoracic echocardiography, and systolic and diastolic ascending aortic diameters (SD and DD respectively) were recorded in M-mode 3 cm above the aortic valve from a parasternal long-axis view. Aortic elastic properties were calculated using aortic data and forearm blood pressure values. RESULTS: SD and DD of MELAS patients and gene carriers were enlarged compared with controls. Aortic stiffness index was increased (16.4+/-3.7 vs 3.6+/-1.1, p=0.00001), while aortic strain (0.035+/-0.012% vs 0.146+/-0.050%, p=0.00002) and aortic distensibility (1.03+/-0.30 cm2/dynes 10(-6) vs 4.70+/-1.69 cm2/dynes 10(-6), p=0.0002) were decreased in MELAS patients compared with controls. Aortic elastic properties of gene carriers were between MELAS patients and controls. CONCLUSIONS: Increased ascending aortic stiffness and enlarged aortic dimensions suggesting vascular remodelling were found in MELAS patients as compared with controls.


Asunto(s)
Aorta/fisiopatología , ADN Mitocondrial/genética , Síndrome MELAS/genética , Adulto , Aorta/diagnóstico por imagen , Presión Sanguínea , Ecocardiografía , Elasticidad , Femenino , Heterocigoto , Humanos , Síndrome MELAS/fisiopatología , Masculino , Mutación
15.
Echocardiography ; 26(4): 371-7, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19054040

RESUMEN

BACKGROUND: Description and quantification of regional left ventricular (LV) rotation and the time course of LV rotation might provide further insight into LV function. METHODS: The study comprised 60 healthy volunteers (age 39 +/- 15 years, 31 men) in whom complete global and regional LV rotation could be assessed at both the basal and apical LV level with speckle tracking echocardiography, using QLAB advanced quantification software version 6.0 (Philips, Best, The Netherlands). RESULTS: At the LV basal level, a brief counterclockwise rotation from aortic valve opening until 25% ejection was seen in the anterior segments (anterior, anteroseptal, anterolateral) only. Clockwise rotation in the anterior segments at the basal level was decreased as compared to the posterior segments (inferior, inferoseptal, inferolateral) from 25% ejection until aortic valve closure. At the LV apical level, all segments showed a brief clockwise rotation during the isovolumic contraction phase. Also, at this level there were no differences in regional LV rotation at any other moment during the cardiac cycle. There was a marked de-rotation from the moment of maximal rotation until E-peak at the LV basal level (79 +/- 18%) whereas de-rotation during this interval was less pronounced at the LV apical level (55 +/- 21%). Only at the LV basal level significant linear relationships were seen between the E/A ratio and de-rotation extent and velocity from mitral valve opening until E-peak (R(2)= 0.42 and R(2)= 0.40, respectively, both P < 0.001). CONCLUSION: In the normal human heart significant regional differences in LV rotation and de-rotation exist.


Asunto(s)
Ecocardiografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Función Ventricular Izquierda/fisiología , Adulto , Femenino , Humanos , Masculino , Rotación
17.
Echocardiography ; 26(2): 189-95, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19054032

RESUMEN

BACKGROUND: Dobutamine stress echocardiography (DSE) suffers from high interobserver and inter-institution variability in the diagnosis of myocardial ischemia. Therefore, we developed a three-dimensional (3D) analysis tool that makes it possible to anatomically align 3D rest and stress data systematically, to generate optimal, nonforeshortened standard anatomical cross sections and to analyse the images synchronized and side-by-side. AIM OF THE STUDY: To investigate whether this 3D analysis tool could improve interobserver agreement on myocardial ischemia during 3D DSE. METHODS: The study comprised 34 consecutive patients with stable chest pain who underwent both noncontrast and contrast 3D DSE. Two observers scored segmental wall motion using a conventional analysis and the novel analysis with the new 3D tool. RESULTS: The two observers agreed on the presence or absence of myocardial ischemia in 81 of 102 coronary territories (agreement 79%, kappa (kappa) 0.28) during noncontrast 3D imaging and 92 of 102 coronary territories (agreement 90%, kappa 0.65) during contrast-enhanced 3D imaging. With the new 3D analysis software these numbers improved to 98 of 102 coronary territories (agreement 96%, kappa 0.69) during noncontrast 3D imaging and 98 of 102 coronary territories (agreement 96%, kappa 0.82) during contrast-enhanced 3D imaging. CONCLUSION: The use of a 3D DSE analysis tool improves interobserver agreement for myocardial ischemia both for noncontrast and contrast images.


Asunto(s)
Ecocardiografía de Estrés/métodos , Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Variaciones Dependientes del Observador , Estudios Retrospectivos
18.
Eur Heart J ; 29(11): 1386-96, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18441322

RESUMEN

AIMS: Studies reporting improved left ventricular (LV) function of percutaneous skeletal myoblast (SkM) injection in patients with ischaemic cardiomyopathy had follow-up not exceeding 12 months, and did not include a control group. Our group has reported evidence for myoblast efficacy in the first five out of the 14 treated patients. The objective of the present evaluation was to assess if these effects were sustained at long-term follow-up. We compared function of patients treated with SkM 4 years earlier with a matched control group. Secondary endpoints included mortality, NYHA class, N-terminal pro-B-natriuretic peptide levels, incidence of arrhythmias, and quality of life. METHODS AND RESULTS: Fourteen patients with ischaemic cardiomyopathy who underwent SkM injection were compared with 28 non-randomized control patients matched for age, sex, location, and extent of myocardial infarction. Contrast echocardiography and tissue Doppler imaging (TDI) was performed to compare global and regional LV function. At 4-year follow-up, three patients (21%) had died in the treated group and 11 patients (39%) in the control group (P = 0.8). In the survivors, LV ejection fraction (EF) was 35 +/- 10% and 37 +/- 9% in the SkM group and 36 +/- 8% and 36 +/- 6% in the controls at baseline and 4 years follow-up, respectively (P = 0.96 between groups at follow-up). TDI-derived systolic velocity in the injected sites was 5.4 +/- 1.8 cm/s in the SkM group when compared with 5.1 +/- 1.6 cm/s in corresponding sites in the control group (P = 0.47). None of the secondary endpoints showed a difference between the groups. However, in the patients fitted with an internal cardioverter defibrillator, more arrhythmias leading to interventions occurred in the treated group than in the control group, 87% and 13%, respectively (P = 0.015). CONCLUSION: Percutaneous intramyocardial SkM injection in ischaemic cardiomyopathy has no sustained positive effect on resting global or regional LV function, respectively, at 4-year follow-up. Moreover, the procedure may induce a higher risk of developing serious arrhythmias, but larger patient series are required before more precise characterization of the safety and efficacy profile of the procedure is possible.


Asunto(s)
Cardiomiopatía Dilatada/terapia , Mioblastos Esqueléticos/trasplante , Isquemia Miocárdica/terapia , Anciano , Cardiomiopatía Dilatada/mortalidad , Cardiomiopatía Dilatada/fisiopatología , Ecocardiografía/métodos , Métodos Epidemiológicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mioblastos Esqueléticos/fisiología , Infarto del Miocardio , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Calidad de Vida , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología
19.
Orv Hetil ; 150(39): 1834-8, 2009 Sep 27.
Artículo en Húngaro | MEDLINE | ID: mdl-19758963

RESUMEN

Based on recently available clinical experiences and criteria, one third of heart failure patients prove to be non-responder despite cardiac resynchronization therapy (CRT) and lack improvement in their clinical status despite optimal treatment. This fact leaded to a new research direction to find a parameter measured by a non-invasive imaging method (for instance echocardiography), which is able to evaluate left ventricular dyssynchrony and to select patients capable for CRT. The aim of this review is to demonstrate the possible role of the newest echocardiography method, the real-time three-dimensional echocardiography based on the available literature.


Asunto(s)
Estimulación Cardíaca Artificial , Ecocardiografía Tridimensional , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/terapia , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos
20.
Orv Hetil ; 150(42): 1925-31, 2009 Oct 18.
Artículo en Húngaro | MEDLINE | ID: mdl-19812010

RESUMEN

Hypertrophic cardiomyopathy is a relatively common hereditary disorder, which is associated with cardiac morphologic and functional alterations. Echocardiography is a non-invasive, simple and easy-to-learn method to evaluate patients with cardiomyopathy. The aim of this review paper is to demonstrate the possible diagnostic role of one of the newest echocardiographic development, the real-time 3-dimensional echocardiography in the evaluation of hypertrophic cardiomyopathy.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ecocardiografía Tridimensional , Cardiomiopatía Hipertrófica/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Válvula Mitral/diagnóstico por imagen , Contracción Miocárdica , Valor Predictivo de las Pruebas , Pronóstico , Índice de Severidad de la Enfermedad , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA