Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Radiol Med ; 129(4): 615-622, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38512616

RESUMEN

PURPOSE: The accurate prediction of treatment response in locally advanced rectal cancer (LARC) patients undergoing MRI-guided radiotherapy (MRIgRT) is essential for optimising treatment strategies. This multi-institutional study aimed to investigate the potential of radiomics in enhancing the predictive power of a known radiobiological parameter (Early Regression Index, ERITCP) to evaluate treatment response in LARC patients treated with MRIgRT. METHODS: Patients from three international sites were included and divided into training and validation sets. 0.35 T T2*/T1-weighted MR images were acquired during simulation and at each treatment fraction. The biologically effective dose (BED) conversion was used to account for different radiotherapy schemes: gross tumour volume was delineated on the MR images corresponding to specific BED levels and radiomic features were then extracted. Multiple logistic regression models were calculated, combining ERITCP with other radiomic features. The predictive performance of the different models was evaluated on both training and validation sets by calculating the receiver operating characteristic (ROC) curves. RESULTS: A total of 91 patients was enrolled: 58 were used as training, 33 as validation. Overall, pCR was observed in 25 cases. The model showing the highest performance was obtained combining ERITCP at BED = 26 Gy with a radiomic feature (10th percentile of grey level histogram, 10GLH) calculated at BED = 40 Gy. The area under ROC curve (AUC) of this combined model was 0.98 for training set and 0.92 for validation set, significantly higher (p = 0.04) than the AUC value obtained using ERITCP alone (0.94 in training and 0.89 in validation set). CONCLUSION: The integration of the radiomic analysis with ERITCP improves the pCR prediction in LARC patients, offering more precise predictive models to further personalise 0.35 T MRIgRT treatments of LARC patients.


Asunto(s)
Radiómica , Neoplasias del Recto , Humanos , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/radioterapia , Neoplasias del Recto/patología , Imagen por Resonancia Magnética/métodos , Recto , Terapia Neoadyuvante/métodos , Estudios Retrospectivos
2.
J Med Imaging Radiat Sci ; 55(2): 339-346, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38403521

RESUMEN

BACKGROUND: Virtual Environment Radiotherapy Training (VERT) is a virtual tool used in radiotherapy with a dual purpose: patient education and student training. This scoping review aims to identify the applications of VERT to acquire new skills in specific activities of Radiation Therapists (RTTs) clinical practice and education as reported in the literature. This scoping review will identify any gaps in this field and provide suggestions for future research. METHODS: In accordance with Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) extension for scoping reviews and Arskey and O'Malley framework, an electronic search was conducted to retrieve complete original studies, reporting the use and implementation of VERT for teaching skills to RTTs. Studies were searched in PubMed, EMBASE, and SCOPUS databases and included retrieved articles if they investigated the use of VERT for RTTs training. RESULTS: Of 251 titles, 16 articles fulfilled the selection criteria and most of the studies were qualitative evaluation studies (n=5) and pilot studies (n=4). The specific use of VERT for RTTs training was grouped into four categories (Planning CT, Set-up, IGRT, and TPS). CONCLUSION: The use of VERT was described for each category by examining the interaction of the students or trainee RTTs in performing each phase within the virtual environment and describing their perceptions. This system Virtual Reality (VR) enables the development of specific motor skills without interfering and pressurising clinical resources by using clinical equipment in a risk-free offline environment, improving the clinical confidence of students or trainee RTTs. However, even if VR can be integrated into the RTTs training with a great advantage, VERT has still not been embraced. This mainly due to the presence of significant issues and limitations, such as inadequate coverage within the current literature, software and hardware costs.


Asunto(s)
Realidad Virtual , Humanos , Radioterapia , Competencia Clínica
3.
Radiat Oncol ; 19(1): 52, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671526

RESUMEN

BACKGROUND: Oligo-progression or further recurrence is an open issue in the multi-integrated management of oligometastatic disease (OMD). Re-irradiation with stereotactic body radiotherapy (re-SBRT) technique could represent a valuable treatment option to improve OMD clinical outcomes. MRI-guided allows real-time visualization of the target volumes and online adaptive radiotherapy (oART). The aim of this retrospective study is to evaluate the efficacy and toxicity profile of MRI-guided repeated SBRT (MRIg-reSBRT) in the OMD setting and propose a re-SBRT classification. METHODS: We retrospectively analyzed patients (pts) with recurrent liver metastases or abdominal metastatic lesions between 1 and 5 centimeters from liver candidate to MRIg-reSBRT showing geometric overlap between the different SBRT courses and assessing whether they were in field (type 1) or not (type 2). RESULTS: Eighteen pts completed MRIg-reSBRT course for 25 metastatic hepatic/perihepatic lesions from July 2019 to January 2020. A total of 20 SBRT courses: 15 Type 1 re-SBRT (75%) and 5 Type 2 re-SBRT (25%) was delivered. Mean interval between the first SBRT and MRIg-reSBRT was 8,6 months. Mean prescribed dose for the first treatment was 43 Gy (range 24-50 Gy, mean BEDα/ß10=93), while 41 Gy (range 16-50 Gy, mean BEDα/ß10=92) for MRIg-reSBRT. Average liver dose was 3,9 Gy (range 1-10 Gy) and 3,7 Gy (range 1,6-8 Gy) for the first SBRT and MRIg-reSBRT, respectively. No acute or late toxicities were reported at a median follow-up of 10,7 months. The 1-year OS and PFS was 73,08% and 50%, respectively. Overall Clinical Benefit was 54%. CONCLUSIONS: MRIg-reSBRT could be considered an effective and safe option in the multi-integrated treatment of OMD.


Asunto(s)
Neoplasias Hepáticas , Imagen por Resonancia Magnética , Radiocirugia , Radioterapia Guiada por Imagen , Humanos , Radiocirugia/métodos , Radiocirugia/efectos adversos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Radioterapia Guiada por Imagen/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética/métodos , Anciano de 80 o más Años , Adulto
4.
Artículo en Inglés | MEDLINE | ID: mdl-38405058

RESUMEN

Introduction: Advancements in MRI-guided radiotherapy (MRgRT) enable clinical parallel workflows (CPW) for online adaptive planning (oART), allowing medical physicists (MPs), physicians (MDs), and radiation therapists (RTTs) to perform their tasks simultaneously. This study evaluates the impact of this upgrade on the total treatment time by analyzing each step of the current 0.35T-MRgRT workflow. Methods: The time process of the workflow steps for 254 treatment fractions in 0.35 MRgRT was examined. Patients have been grouped based on disease site, breathing modality (BM) (BHI or FB), and fractionation (stereotactic body RT [SBRT] or standard fractionated long course [LC]). The time spent for the following workflow steps in Adaptive Treatment (ADP) was analyzed: Patient Setup Time (PSt), MRI Acquisition and Matching (MRt), MR Re-contouring Time (RCt), Re-Planning Time (RPt), Treatment Delivery Time (TDt). Also analyzed was the timing of treatments that followed a Simple workflow (SMP), without the online re-planning (PSt + MRt + TDt.). Results: The time analysis revealed that the ADP workflow (median: 34 min) is significantly (p < 0.05) longer than the SMP workflow (19 min). The time required for ADP treatments is significantly influenced by TDt, constituting 40 % of the total time. The oART steps (RCt + RPt) took 11 min (median), representing 27 % of the entire procedure. Overall, 79.2 % of oART fractions were completed in less than 45 min, and 30.6 % were completed in less than 30 min. Conclusion: This preliminary analysis, along with the comparative assessment against existing literature, underscores the potential of CPW to diminish the overall treatment duration in MRgRT-oART. Additionally, it suggests the potential for CPW to promote a more integrated multidisciplinary approach in the execution of oART.

5.
Clin Transl Radiat Oncol ; 47: 100808, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39005509

RESUMEN

Introduction: Organ motion (OM) and volumetric changes pose challenges in radiotherapy (RT) for locally advanced cervical cancer (LACC). Magnetic Resonance-guided Radiotherapy (MRgRT) combines improved MRI contrast with adaptive RT plans for daily anatomical changes. Our goal was to analyze cervico-uterine structure (CUS) changes during RT to develop strategies for managing OM. Materials and methods: LACC patients received chemoradiation by MRIdian system with a simultaneous integrated boost (SIB) protocol. Prescription doses of 55-50.6 Gy at PTV1 and 45-39.6 Gy at PTV2 were given in 22 and 25 fractions. Daily MRI scans were co-registered with planning scans and CUS changes were assessed.Six PTVs were created by adding 0.5, 0.7, 1, 1.3, 1.5, and 2 cm margins to the CUS, based on the simulation MRI. Adequate margins were determined to include 95 % of the CUSs throughout the entire treatment in 95 % of patients. Results: Analysis of 15 LACC patients and 372 MR scans showed a 31 % median CUS volume decrease. Asymmetric margins of 2 cm cranially, 0.5 cm caudally, 1.5 cm posteriorly, 2 cm anteriorly, and 1.5 cm on both sides were optimal for PTV, adapting to CUS variations. Post-14th fraction, smaller margins of 0.7 cm cranially, 0.5 cm caudally, 1.3 cm posteriorly, 1.3 cm anteriorly, and 1.3 cm on both sides sufficed. Conclusion: CUS mobility varies during RT, suggesting reduced PTV margins after the third week. MRgRT with adaptive strategies optimizes dose delivery, emphasizing the importance of streamlined IGRT with reduced PTV margins using a tailored MRgRT workflow with hybrid MRI-guided systems.

6.
Phys Med ; 121: 103369, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38669811

RESUMEN

PURPOSE: In radiotherapy it is often necessary to transfer a patient's DICOM (Digital Imaging and COmmunications in Medicine) dataset from one system to another for re-treatment, plan-summation or registration purposes. The aim of the study is to evaluate effects of dataset transfer between treatment planning systems. MATERIALS AND METHODS: Twenty-five patients treated in a 0.35T MR-Linac (MRidian, ViewRay) for locally-advanced pancreatic cancer were enrolled. For each patient, a nominal dose distribution was optimized on the planning MRI. Each plan was daily re-optimized if needed to match the anatomy and exported from MRIdian-TPS (ViewRay Inc.) to Eclipse-TPS (Siemens-Varian). A comparison between the two TPSs was performed considering the PTV and OARs volumes (cc), as well as dose coverages and clinical constraints. RESULTS: From the twenty-five enrolled patients, 139 plans were included in the data comparison. The median values of percentage PTV volume variation are 10.8 % for each fraction, while percentage differences of PTV coverage have a mean value of -1.4 %. The median values of the percentage OARs volume variation are 16.0 %, 7.0 %, 10.4 % and 8.5 % for duodenum, stomach, small and large bowel, respectively. The percentage variations of the dose constraints are 41.0 %, 52.7 % and 49.8 % for duodenum, stomach and small bowel, respectively. CONCLUSIONS: This study has demonstrated a non-negligible variation in size and dosimetric parameters when datasets are transferred between TPSs. Such variations should be clinically considered. Investigations are focused on DICOM structure algorithm employed by the TPSs during the transfer to understand the cause of such variations.


Asunto(s)
Neoplasias Pancreáticas , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Imagen por Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA