Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Clin Chem ; 65(3): 406-418, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30647123

RESUMEN

BACKGROUND: Clinical practice guidelines recommend estimation of glomerular filtration rate (eGFR) using validated equations based on serum creatinine (eGFRcr), cystatin C (eGFRcys), or both (eGFRcr-cys). However, when compared with the measured GFR (mGFR), only eGFRcr-cys meets recommended performance standards. Our goal was to develop a more accurate eGFR method using a panel of metabolites without creatinine, cystatin C, or demographic variables. METHODS: An ultra-performance liquid chromatography-tandem mass spectrometry assay for acetylthreonine, phenylacetylglutamine, pseudouridine, and tryptophan was developed, and a 20-day, multiinstrument analytical validation was conducted. The assay was tested in 2424 participants with mGFR data from 4 independent research studies. A new GFR equation (eGFRmet) was developed in a random subset (n = 1615) and evaluated in the remaining participants (n = 809). Performance was assessed as the frequency of large errors [estimates that differed from mGFR by at least 30% (1 - P30); goal <10%]. RESULTS: The assay had a mean imprecision (≤10% intraassay, ≤6.9% interassay), linearity over the quantitative range (r 2 > 0.98), and analyte recovery (98.5%-113%). There was no carryover, no interferences observed, and analyte stability was established. In addition, 1 - P30 in the validation set for eGFRmet (10.0%) was more accurate than eGFRcr (13.1%) and eGFRcys (12.0%) but not eGFRcr-cys (8.7%). Combining metabolites, creatinine, cystatin C, and demographics led to the most accurate equation (7.0%). Neither equation had substantial variation among population subgroups. CONCLUSIONS: The new eGFRmet equation could serve as a confirmatory test for GFR estimation.


Asunto(s)
Cromatografía Liquida/métodos , Tasa de Filtración Glomerular , Espectrometría de Masas en Tándem/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Glutamina/análogos & derivados , Glutamina/sangre , Humanos , Masculino , Persona de Mediana Edad , Seudouridina/sangre , Reproducibilidad de los Resultados , Treonina/análogos & derivados , Treonina/sangre , Triptófano/sangre
2.
Artículo en Inglés | MEDLINE | ID: mdl-28029544

RESUMEN

Early detection of insulin resistance (IR) and/or impaired glucose tolerance (IGT) is crucial for delaying and preventing the progression toward type 2 diabetes. We recently developed and validated a straightforward metabolite-based test for the assessment of IR and IGT in a single LC-MS/MS method. Plasma samples were diluted with isotopically-labeled internal standards and extracted by simple protein precipitation. The extracts were analyzed by LC-MS/MS for the quantitation of 2-hydroxybutyric acid (0.500-40.0µg/mL), 3-hydroxybutyric acid (1.00-80.0µg/mL), 4-methyl-2-oxopentanoic acid (0.500-20.0µg/mL), 1-linoleoyl-2-hydroxy-sn-glycero-3-phosphocholine (2.50-100µg/mL), oleic acid (10.0-400µg/mL), pantothenic acid (0.0100-0.800µg/mL), and serine (2.50-100µg/mL). Liquid chromatography was carried out on a reversed phase column with a run time of 3.1min and the mass spectrometer operated in negative MRM mode. Method validation was performed on three identical LC-MS/MS systems with five runs each. Sufficient linearity (R2>0.99) was observed for all the analytes over the ranges. The imprecision (CVs) was found to be less than 5.5% for intra-run and less than 5.8% for inter-run for the seven analytes. The analytical recovery was determined to be between 96.3 and 103% for the seven analytes. This fast and robust method has subsequently been used for patient sample analysis for the assessment of IR and IGT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA