Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Am J Vet Res ; 69(5): 652-8, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18447797

RESUMEN

OBJECTIVE: To determine whether lipid particle coalescence develops in veterinary parenteral nutrition (PN) admixture preparations that are kept at room temperature (23 degrees C) for > 48 hours and whether that coalescence is prevented by admixture filtration, refrigeration, or agitation. SAMPLE POPULATION: 15 bags of veterinary PN solutions. PROCEDURES: Bags of a PN admixture preparation containing a lipid emulsion were suspended and maintained under different experimental conditions (3 bags/group) for 96 hours while admixtures were dispensed to simulate IV fluid administration (rate, 16 mL/h). Bags were kept static at 4 degrees C (refrigeration); kept at 23 degrees C (room temperature) and continuously agitated; kept at room temperature and agitated for 5 minutes every 4 hours; kept static at room temperature and filtered during delivery; or kept static at room temperature (control conditions). Admixture samples were collected at 0, 24, 48, 72, and 96 hours and examined via transmission electron microscopy to determine lipid particle diameters. At 96 hours, 2 samples were collected at a location distal to the filter from each bag in that group for bacterial culture. RESULTS: Distribution of lipid particle size in the control preparations and experimentally treated preparations did not differ significantly. A visible oil layer developed in continuously agitated preparations by 72 hours. Bacterial cultures of filtered samples yielded no growth. CONCLUSIONS AND CLINICAL RELEVANCE: Data indicated that the veterinary PN admixtures kept static at 23 degrees C are suitable for use for at least 48 hours. Manipulations of PN admixtures appear unnecessary to prolong lipid particle stability, and continuous agitation may hasten lipid breakdown.


Asunto(s)
Emulsiones Grasas Intravenosas/química , Nutrición Parenteral/veterinaria , Animales , Estabilidad de Medicamentos , Microscopía Electrónica de Transmisión/veterinaria , Nutrición Parenteral/métodos , Tamaño de la Partícula
2.
Vet Surg ; 37(3): 212-21, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18394066

RESUMEN

OBJECTIVE: To compare Chinese finger trap (CFT) and 4 friction suture (FFS) techniques to secure gastrostomy (GT), jejunostomy (JT), and thoracostomy (TT) tubes of different materials. STUDY DESIGN: Prospective experimental study. ANIMALS: Canine cadavers (n=20). METHODS: Randomly, GT (n=20), JT (20), and TT (20) were inserted using 2 different suture techniques (10 for each tube type) and either silicone or another material (10 for each type). Axial distraction was applied to each tube until failure. Force and displacement to failure and failure mode were recorded and compared between techniques and materials for GT, JT, and TT. RESULTS: CFT failed most commonly by suture breakage whereas FFS failed mainly by tube slippage (P=.003). For GT, failure occurred more commonly by tube slippage (n=15; P<.001) whereas tube breakage was more common for JT (n=10; P<.001) and suture breakage for TT (n=14; P=.022). Silicone had higher force to failure than latex with GT, lower force to failure than red rubber with JT, and lower displacement to failure than polyvinylchloride with TT. CONCLUSIONS: Different failure modes occurred for CFT (suture breakage) and FFS (tube slippage) and among different tube types (tube slippage with GT, tube breakage with JT, and suture breakage with TT). Based on study results, CFT is preferred to FFS for anchoring silicone GT and TT. Silicone GT, red rubber JT, and polyvinylchloride TT were more secure than latex GT, silicone JT, and silicone TT, respectively. CLINICAL RELEVANCE: CFT should be preferred over FFS based on force and displacement to failure, but tube type and tissue reaction could influence anchoring strength.


Asunto(s)
Gastrostomía/veterinaria , Intubación Gastrointestinal/veterinaria , Yeyunostomía/veterinaria , Elastómeros de Silicona , Técnicas de Sutura/veterinaria , Toracostomía/veterinaria , Animales , Cadáver , Perros , Falla de Equipo , Gastrostomía/instrumentación , Gastrostomía/métodos , Intubación Gastrointestinal/instrumentación , Intubación Gastrointestinal/métodos , Yeyunostomía/instrumentación , Yeyunostomía/métodos , Estudios Prospectivos , Toracostomía/instrumentación , Toracostomía/métodos
3.
J Am Vet Med Assoc ; 230(12): 1841-8, 2007 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-17571987

RESUMEN

OBJECTIVE: To assess the reliability and accuracy of a predictive rectal thermometer, an infrared auricular thermometer designed for veterinary use, and a subcutaneous temperature-sensing microchip for measurement of core body temperature over various temperature conditions in dogs. DESIGN: Prospective study. ANIMALS: 8 purpose-bred dogs. PROCEDURES: A minimum of 7 days prior to study commencement, a subcutaneous temperature-sensing microchip was implanted in 1 of 3 locations (interscapular, lateral aspect of shoulder, or sacral region) in each dog. For comparison with temperatures measured via rectal thermometer, infrared auricular thermometer, and microchip, core body temperature was measured via a thermistor-tipped pulmonary artery (TTPA) catheter. Hypothermia was induced during anesthesia at the time of TTPA catheter placement; on 3 occasions after placement of the catheter, hyperthermia was induced via administration of a low dose of endotoxin. Near-simultaneous duplicate temperature measurements were recorded from the TTPA catheter, the rectal thermometer, auricular thermometer, and subcutaneous microchips during hypothermia, euthermia, and hyperthermia. Reliability (variability) of temperature measurement for each device and agreement between each device measurement and core body temperature were assessed. RESULTS: Variability between duplicate near-simultaneous temperature measurements was greatest for the auricular thermometer and least for the TTPA catheter. Measurements obtained by use of the rectal thermometer were in closest agreement with core body temperature; for all other devices, temperature readings typically underestimated core body temperature. CONCLUSIONS AND CLINICAL RELEVANCE: Among the 3 methods of temperature measurement, rectal thermometry provided the most accurate estimation of core body temperature in dogs.


Asunto(s)
Temperatura Corporal/fisiología , Cateterismo de Swan-Ganz/veterinaria , Fiebre/veterinaria , Hipotermia/veterinaria , Arteria Pulmonar/fisiología , Termómetros/veterinaria , Animales , Cateterismo de Swan-Ganz/métodos , Estudios Cruzados , Perros , Oído , Femenino , Fiebre/diagnóstico , Hipotermia/diagnóstico , Masculino , Procedimientos Analíticos en Microchip/veterinaria , Estudios Prospectivos , Recto , Sensibilidad y Especificidad , Termómetros/normas
4.
Neurosurg Focus ; 21(3): E11, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-17029335

RESUMEN

OBJECT: The object of this study was to determine whether the combination of cyclosporine and simvastatin could ameliorate cerebral vasospasm after subarachnoid hemorrhage (SAH) in a canine model to a greater extent than simvastatin alone. METHODS: Animals were assigned to one of three groups: control (five dogs), simvastatin alone (four), or simvastatin and cyclosporine (four). A double SAH model was used. Baseline basilar artery (BA) angiograms were obtained. These were repeated at Days 3, 7, and 10. Measurement of the BA diameter was performed. Decreased BA diameter was seen on Day 3 in the control and simvastatin/cyclosporine group. A return to baseline diameters was seen by Day 7. An increase from baseline diameter was seen in the simvastatin group at Day 10. CONCLUSIONS: Cyclosporine may interfere with the vasodilatory effects of simvastatin. Vasodilation greater than baseline is seen at Day 10 in the simvastatin group. The combination of simvastatin and cyclosporine does not ameliorate cerebral vasospasm in a canine model to a greater extent than simvastatin alone.


Asunto(s)
Ciclosporina/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Inmunosupresores/uso terapéutico , Simvastatina/uso terapéutico , Vasoespasmo Intracraneal/tratamiento farmacológico , Análisis de Varianza , Angiografía/métodos , Animales , Arteria Basilar/efectos de los fármacos , Arteria Basilar/patología , Modelos Animales de Enfermedad , Perros , Quimioterapia Combinada , Distribución Aleatoria , Hemorragia Subaracnoidea/complicaciones , Factores de Tiempo , Vasoespasmo Intracraneal/etiología
5.
Ann Thorac Surg ; 77(1): 203-9, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14726062

RESUMEN

BACKGROUND: Poor healing of median sternotomy can significantly increase morbidity, mortality, and hospital costs. Effective union requires reliable sternal fixation. Although wire has proven the most reliable and widely used sternotomy closure material, no experimental studies have compared a large variety of wiring techniques in a human model. We developed an easily reproducible experimental model using cadaveric human sterna and compared several wiring methods to assess closure strength and stability. METHODS: Fifty-three fresh adult human cadaveric sternal plates with adjacent ribs were fixed with specially designed spiked stainless steel clamps and attached to a texture analyzer. Single peristernal and transsternal, alternating single peristernal and transsternal, figure-eight peristernal, figure-eight pericostal, and Robicsek closures using no. 5 stainless steel wires were tested. We evaluated bone density, stiffness, and displacement using perpendicular, repetitive variable force loads of 800 Newtons cycling at a rate of 0.5 mm/s. RESULTS: There were no significant differences in age, sex, or bone density in outcome measures of the sternal groups. No clamp failures or clamp damage to the specimens occurred. The single peristernal and alternating peristernal and transsternal closures proved superior in strength and stability (p < 0.001). The figure-eight peristernal, then the single transsternal, then the Robicsek were next stablest groups in decreasing order. The figure-eight pericostal closure had the highest failure rate (p < 0.001). CONCLUSIONS: This novel model of sternotomy closure testing was reliable, inexpensive, and easily reproducible. The mechanical stability of peristernal and alternating peristernal and transsternal wires was significantly greater than that of the other tested methods. Pericostal figure-eight closures were not sufficiently stable to be considered a reliable method of primary sternotomy repair.


Asunto(s)
Esternón/fisiología , Esternón/cirugía , Anciano , Fenómenos Biomecánicos/instrumentación , Cadáver , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Torácicos/métodos
6.
Artif Organs ; 20(5): 670-677, 1996 May.
Artículo en Inglés | MEDLINE | ID: mdl-28868701

RESUMEN

The increased use of centrifugal mechanical assist (CMA) for treatment of refractory postcardiotomy cardiogenic shock highlights the need for experimental testing to improve clinical results. This report describes the preoperative conditioning, anesthetic and surgical technique, and postoperative management of a reliable calf model refined in this laboratory for in vivo sub-chronic (96 h) testing of CMA. Holstein bull calves (2 to 3 months old; mean body weight, 78 kg; n = 35) were instrumented for left ventricular CMA; 4 of these calves were sham-operated controls. Anesthetic recovery and postoperative restraint were accomplished in a specially designed crate to which each calf was preconditioned extensively. Younger calves were more readily conditioned and more tolerant of postoperative restraint than older calves. One calf died of ventricular fibrillation in-traoperatively. One calf that had been heparinized developed uncontrollable hemothorax and died 12 h postoperatively. One calf prematurely dislodged his aortic cannula 15 h postoperatively and exsanguinated. Six calves developed pelvic limb paresis or paralysis because of lumbar spinal cord thromboembolism by 36 h postoperatively, and 3 of these calves were sacrificed by 42 h postoperatively. Fifteen calves required sedation in the first 12 h after the operation. Tachycardia associated with bottle feeding occurred in 15 calves. Second-degree atrioventricular block was noted frequently during deep relaxation. Postmortem examination demonstrated the absence of surgical wound and distant infection, security of cannulae in all but the calf that prematurely dislodged the aortic cannula, absence of thrombus formation at cannu-lation sites, and presence of thromboembolism in 51% of the calves. The incidence of thromboembolic lesions was not influenced by the need for chemical restraint, by the occurrence of feeding-associated tachycardia, or by the presence of atrioventricular block. There were no thromboembolic lesions in any of the sham-operated controls.

7.
J Am Vet Med Assoc ; 221(3): 378-80, 2002 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-12164534

RESUMEN

OBJECTIVE: To compare measurements of body temperature obtained with auricular thermometers versus rectal thermometers in dogs with otitis externa. DESIGN: Prospective study. ANIMALS: 100 client-owned dogs: 50 with and 50 without clinical evidence of otitis externa. PROCEDURE: Dogs were evaluated for the presence of otitis externa on the basis of clinical signs, otoscopic examination, and cytologic evaluation of ear exudate. Auricular and rectal temperatures were obtained simultaneously in all dogs prior to and following ear examination. RESULTS: There was a high correlation between auricular and rectal temperatures in dogs with otitis externa both prior to and after ear manipulation. Significant differences were not detected in temperature measurements among dogs with different degrees of otitis externa. CONCLUSIONS AND CLINICAL RELEVANCE: Auricular temperature readings obtained by use of an auricular thermometer in dogs with otitis externa are accurate measurements of body temperature, compared with rectal temperature measurements. Temperature measurements are reliable before and after examination of the ear canal.


Asunto(s)
Temperatura Corporal/fisiología , Enfermedades de los Perros/metabolismo , Conducto Auditivo Externo/metabolismo , Otitis Externa/veterinaria , Recto/metabolismo , Termómetros/veterinaria , Animales , Perros , Otitis Externa/metabolismo , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
J Vet Emerg Crit Care (San Antonio) ; 20(2): 207-15, 2010 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-20487248

RESUMEN

OBJECTIVE: To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. DESIGN: Prospective clinical study. SETTING: University teaching hospital. ANIMALS: Eleven client-owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). INTERVENTIONS: Blood pressure measurement. MEASUREMENTS AND MAIN RESULTS: Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hgor=100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland-Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. CONCLUSIONS: The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.


Asunto(s)
Determinación de la Presión Sanguínea/veterinaria , Enfermedades de los Perros/diagnóstico , Hipertensión/veterinaria , Hipotensión/veterinaria , Oscilometría/veterinaria , Ultrasonografía Doppler/veterinaria , Animales , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Determinación de la Presión Sanguínea/normas , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/fisiopatología , Perros , Femenino , Hospitales Veterinarios , Hospitales Universitarios , Hipertensión/diagnóstico , Hipotensión/diagnóstico , Masculino , Missouri , Oscilometría/métodos , Oscilometría/normas , Estudios Prospectivos , Ultrasonografía Doppler/normas
9.
Artif Organs ; 26(11): 994-7, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12406159

RESUMEN

Because of the infrequent application of cardiac assist devices for postcardiotomy heart failure, most published reports include the results of learning curves from multiple surgeons. Between October 1986 and June 2001, a single surgeon used 35 Sarns Centrifugal Pumps as ventricular assist devices in 21 patients with severe hemodynamic compromise after open heart surgery (0.88% incidence). Patients' ages ranged from 39 to 77 (mean, 59.6 years). Three patients required right ventricular assist devices, 4 left ventricular assist devices, and 14 had biventricular assist devices. For all, the indication for application was inability to wean from cardiopulmonary bypass despite multiple inotropes and intraaortic balloon pumping. All were expected to be intraoperative deaths without further mechanical assistance. Patients were assisted from 2 to 434 h (median, 48 h). Fifteen patients (71.4%) were weaned from device(s), and 11 patients (52.4%) were hospital survivors. Actuarial survival in those dismissed from the hospital was 78% at 5 years and 39% at 10 years. Patients facing certain demise after cardiac surgery can be salvaged with temporary centrifugal mechanical assist. Results are competitive with that achieved with more sophisticated devices. Hospital survivors enjoy reasonable longevity.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Centrifugación , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Acontecimientos que Cambian la Vida , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Retrospectivos , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA