Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Hypertension ; 7(1): 97-104, 1985.
Artículo en Inglés | MEDLINE | ID: mdl-3980063

RESUMEN

A noninvasive investigation was undertaken in four blood pressure (BP) groups of untreated 49-year-old men derived by screening a random population sample: normotensive men (n = 20) and subjects with borderline (n = 30), mild (n = 45), or moderate BP elevation (n = 24). We here report the findings regarding left ventricular (LV) wall stress, LV wall thickness, and LV systolic function. Although there was an increase in LV wall thickness with hypertension, the raised BP was not compensated for by a sufficient degree of LV wall thickening to keep wall stress within normal limits in the hypertensive groups. Among a subset of individuals with pronounced increase in wall thickness peak systolic wall stress approached the normal range, but end-systolic wall stress was still high. In spite of high wall stress LV systolic function was normal or supranormal in the hypertensive men. The LV ejection phase indices showed a close inverse correlation with end-systolic wall stress (r = -0.67 to -0.84) in all four BP groups, but no correlation or only a weak correlation with peak systolic wall stress (r = 0.18 to -0.40). As judged from the relationship between end-systolic wall stress and ejection phase indices of LV function in the normotensive controls, all hypertensive groups had higher than expected values for LV ejection phase indices, which indicates an increased myocardial contractility secondary to adrenergic stimulation or to a more efficient contractile machinery in the myocardial cells.


Asunto(s)
Ventrículos Cardíacos/fisiopatología , Hipertensión/fisiopatología , Contracción Miocárdica , Sístole , Ecocardiografía , Ventrículos Cardíacos/anatomía & histología , Humanos , Masculino , Persona de Mediana Edad , Estrés Fisiológico , Volumen Sistólico
2.
Hypertension ; 6(3): 329-38, 1984.
Artículo en Inglés | MEDLINE | ID: mdl-6735454

RESUMEN

To study left ventricular (LV) diastolic function of the heart in relation to blood pressure (BP) and other signs of hypertensive cardiac and peripheral vascular changes, isovolumic relaxation time and early diastolic filling were determined in four BP groups of untreated 49-year-old men: normotensive subjects (n = 20), men with borderline hypertension (n = 30), mild hypertension (n = 45), and moderate to severe hypertension (n = 24). Isovolumic relaxation time, measured as the distance between aortic closure (A2, phonocardiography) and mitral valve opening (echocardiography), and early diastolic filling, measured as the distance between mitral valve opening and the O point of the apexcardiogram, tended to increase with BP level, and the total interval from aortic closure to the O point (A2O interval) was significantly prolonged in the two groups with mild and moderate to severe hypertension. A prolonged A2O interval (greater than or equal to 117% of expected value at observed heart rate) was seen in several hypertensives, who had no obvious increase in LV wall thickness on M mode echocardiography. This suggests that a prolonged LV relaxation time may be an early sign of cardiac involvement in primary hypertension. In the group with moderate to severe hypertension, an increase in LV wall thickness was seen together with an increase in resistance at maximal dilation in the calf. This supports the theory that when changes in cardiac structure develop they occur in parallel with structural changes also in the periphery.


Asunto(s)
Diástole , Pruebas de Función Cardíaca , Hipertensión/fisiopatología , Contracción Miocárdica , Presión Sanguínea , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertensión/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Resistencia Vascular
3.
Am J Cardiol ; 88(2): 139-44, 2001 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-11448410

RESUMEN

Pressure recovery has been described in aortic stenosis and may explain the difference occasionally observed between Doppler- and catheter-measured gradients. A narrow ascending aorta (AA) and moderately severe stenosis favors pressure recovery. The aims of this study were to investigate the degree to which these conditions are present in patients with aortic stenosis and high Doppler gradients and to evaluate the magnitude of pressure recovery. One hundred sixteen patients were examined with Doppler echocardiography before aortic valve replacement. Patients with a maximum gradient >70 mm Hg (n = 81) were included. The diameter of the AA was measured and compared with the diameter in an age- and body size-matched group of normal controls (n = 23). Pressure recovery was estimated from a previously validated equation by measuring the maximum Doppler gradient, the effective orifice area (EOA), and the diameter of the AA. The diameter of the AA was similar for patients (mean 3.0 cm, range 2.1 to 4.1) and normal controls (mean 3.0 cm, range 2.3 to 3.5). The maximum Doppler gradient was 107 mm Hg (range 71 to 170) and the EOA was 0.6 cm(2) (range 0.2 to 1.3). The calculated pressure recovery was 18 mm Hg (range 6 to 37), which gives a net gradient of 89 mm Hg (range 51 to 151). Twenty-three percent had a net gradient <70 mm Hg. A cutoff of EOA/AA diameter at >0.2 cm identified 84% of patients (16 of 19) with a net gradient <70 mm Hg. In conclusion, we found that important pressure recovery can be expected in most patients with aortic stenosis and high Doppler gradients. Pressure recovery may explain why some patients with high Doppler gradients are asymptomatic. Also, pressure recovery is a factor to consider in patients with atypical symptomatology and high Doppler gradients when one must decide on valvular replacement.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Doppler , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estudios de Casos y Controles , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Presión , Estudios Retrospectivos
4.
J Thorac Cardiovasc Surg ; 122(2): 287-95, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11479501

RESUMEN

OBJECTIVES: We sought to evaluate the Doppler assessment of effective orifice area in aortic prosthetic valves. The effective orifice area is a less flow-dependent parameter than Doppler gradients that is used to assess prosthetic valve function. However, in vivo reference values show a pronounced spread of effective orifice area and smaller orifices than expected compared with the geometric area. METHODS: Using Doppler echocardiography, we studied patients who received a bileaflet St Jude Medical valve (n = 75; St Jude Medical, Inc, St Paul, Minn) or a tilting disc Omnicarbon valve (n = 46; MedicalCV, Incorporated, Inver Grove Heights, Minn). The prosthetic valves were also investigated in vitro in a steady-flow model with Doppler and catheter measurements in the different orifices. The effective orifice area was calculated according to the continuity equation. RESULTS: In vivo, there was a wide distribution with the coefficient of variation (SD/mean x 100%) for different valve sizes ranging from 21% to 39% in the St Jude Medical valve and from 25% to 33% in the Omnicarbon valve. The differences between geometric orifice area and effective orifice area in vitro were 1.26 +/- 0.41 cm(2) for St Jude Medical and 1.17 +/- 0.38 cm(2) for Omnicarbon valves. The overall effective orifice areas and peak catheter gradients were similar: 1.35 +/- 0.37 cm(2) and 25.9 +/- 16.1 mm Hg for St Jude Medical and 1.46 +/- 0.49 cm(2) and 24.6 +/- 17.7 mm Hg for Omnicarbon. However, in St Jude Medical valves, more pressure was recovered downstream, 11.6 +/- 6.3 mm Hg versus 3.4 +/- 1.6 mm Hg in Omnicarbon valves (P =.0001). CONCLUSIONS: In the patients, we found a pronounced spread of effective orifice areas, which can be explained by measurement errors or true biologic variations. The in vitro effective orifice area was small compared with the geometric orifice area, and we suspect that nonuniformity in the spatial velocity profile causes underestimation. The St Jude Medical and Omnicarbon valves showed similar peak catheter gradients and effective orifice areas in vitro, but more pressure was recovered in the St Jude Medical valve. The effective orifice area can therefore be misleading in the assessment of prosthetic valve performance when bileaflet and tilting disc valves are compared.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Válvula Aórtica/fisiopatología , Determinación de la Presión Sanguínea , Hemodinámica , Humanos , Técnicas In Vitro , Modelos Lineales , Modelos Cardiovasculares , Diseño de Prótesis
5.
J Thorac Cardiovasc Surg ; 116(4): 599-608, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9766588

RESUMEN

OBJECTIVES: Our objectives were to evaluate the long-term bioprosthetic and cardiac functional outcome after insertion (over a 10-year period) of a new-generation porcine zero pressure-fixed Biocor bioprosthesis, as well as to determine the echocardiographic accuracy for selection of patients requiring reoperation. The long-term systematic Doppler echocardiographic assessment after valve replacement with this bioprosthesis is lacking. METHODS: Between January 1983 and January 1993, we inserted 756 Biocor prostheses in the aortic (619) or mitral (137) positions. All 51 patients who had a reoperation during the follow-up time were evaluated echocardiographically before reoperation. Additionally, 263 of 446 patients (59%) with aortic bioprostheses and 42 of 74 patients (57%) with mitral bioprostheses who were alive in January 1993 had long-term echocardiographic follow-up. RESULTS: Group A: Normally functioning bioprostheses were found in the aortic position in 242 of 263 patients and in the mitral position in 33 of 42 patients. Group B: Thirty patients had abnormal bioprosthetic function. Eleven patients had regurgitation, 3 had a combined lesion, and signs of calcification appeared in 16 patients with aortic valves, all with a peak gradient of above 60 mm Hg. Group C: Patients who had a reoperation (41 aortic and 10 mitral) within the follow-up period were followed up echocardiographically from the detection of a possible valve dysfunction until reoperation, and the findings accorded well with those at operation in 49 of 51 patients. CONCLUSIONS: These findings suggest that, during a long-term follow-up, most bioprostheses function normally, facilitating improved heart function. Abnormalities in a bioprosthesis usually develop gradually, enabling their detection by Doppler echocardiographic evaluations performed regularly or in case of any symptomatic deterioration.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Ecocardiografía Doppler , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Análisis de Falla de Equipo , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Reoperación , Resultado del Tratamiento
6.
J Thorac Cardiovasc Surg ; 118(1): 57-65, 1999 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10384185

RESUMEN

OBJECTIVES: Two years after surgery for severe aortic stenosis, we prospectively evaluated the influence of aortic valve replacement, as well as valve type (mechanical or stented biologic) and size, on functional status, left ventricular function, and regression of mass. METHODS: Patients who received either a mechanical (n = 95) or a biologic valve (n = 42) were studied by echocardiography before the operation and after 2 years. RESULTS: The percentage of patients with severe dyspnea decreased from 53% to 13% (P =.001). The cardiac index increased from mean 2.6 L/min per square meter (95% CI: 2.48-2. 72 L/min per square meter) to 3.1 L/min per square meter (95% CI: 2. 94-3.26 L/min per square meter; P =.001). The percentage of the patients with mild-to-moderate diastolic dysfunction decreased from 43% to 18% (P =.001). The left ventricular mass index was reduced by 42.4 g (95% CI: 35-50 g; P =.001). In comparison with biologic valves of the same size, mechanical valves produced a more pronounced reduction in mass index (overall difference 21.7 g; 95% CI: 37.1-6.4 g; P =.007) and a lower mean Doppler gradient (overall difference 4 mm Hg; 95% CI: 2-6 mm Hg; P =.0002). CONCLUSIONS: Patients undergoing aortic valve replacement had an improvement in functional status, as well as systolic and diastolic left ventricular function, and a reduction in left ventricular mass index, irrespective of prosthesis size and type. Mechanical valves are somewhat less obstructive than stented bioprosthetic valves of the same size. They are also associated with a concomitantly more pronounced reduction of left ventricular mass.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/clasificación , Hipertrofia Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Anciano , Válvula Aórtica , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Gasto Cardíaco , Diástole , Disnea/etiología , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Hipertrofia Ventricular Izquierda/etiología , Modelos Lineales , Masculino , Pronóstico , Diseño de Prótesis , Stents , Volumen Sistólico , Sístole , Resultado del Tratamiento , Ultrasonografía
7.
Ann Thorac Surg ; 60(2 Suppl): S447-52, 1995 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7646206

RESUMEN

To determine the long-term outcome of biological and mechanical heart valve prostheses, we compared the Biocor, a new generation of porcine bioprosthesis, with the St. Jude Medical mechanical prosthesis. One hundred consecutive patients operated on between 1983 and 1985 with the Biocor in the aortic, mitral, or both positions (without concomitant cardiac procedures) were followed until January 1993, together with 100 matched patients implanted with the St. Jude valve. The mean age was 66 and 67 years, respectively. The follow-up was 100% complete. Valve-related mortality differed significantly, with a freedom rate of 80.7% +/- 9.0% for the St. Jude group and 97.7% +/- 1.6% for the Biocor group. There were few thromboembolic events, with no significant difference between the groups. Anticoagulant-related hemorrhage occurred almost exclusively in the St. Jude group (2.3%/patient-year), and reoperations were required almost exclusively in the Biocor group (1.8%/patient-year). The occurrence of all valve-related complications (mortality plus morbidity) differed markedly, with an actuarial freedom at 10 years of 55.8% +/- 9.8% for St. Jude and 80.0% +/- 4.4% for the Biocor. Quality of life and echocardiographic measurements did not differ significantly between the groups. We conclude from this study that the long-term performance of the Biocor and St. Jude are comparable, even though valve-related complications tended to be fewer in the Biocor group, with a significantly lower incidence of valve-related death.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Calidad de Vida , Análisis Actuarial , Anciano , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Bioprótesis/mortalidad , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/mortalidad , Humanos , Masculino , Válvula Mitral/cirugía , Complicaciones Posoperatorias , Reoperación , Tasa de Supervivencia , Tromboembolia/etiología
8.
J Am Soc Echocardiogr ; 11(5): 466-77, 1998 May.
Artículo en Inglés | MEDLINE | ID: mdl-9619619

RESUMEN

The objectives of the present investigation were (1) to describe Doppler echocardiographic findings for mechanical and biologic aortic valves at an early stage after operation and later in a stable phase and (2) to study the changes occurring between these investigations. Patients (n = 213) who received a mechanical (St. Jude Medical, Omnicarbon) or a biologic (Biocor) valve were studied by Doppler echocardiography within the first week (baseline, n = 203) and after 2 years (late, n = 172). The comparison of baseline with late investigation (mean +/- SD) showed an increase in systolic blood pressure (137 +/- 18.5 to 154 +/- 20.6 mm Hg, p = 0.0001, n = 112), reduction of heart rate (85 +/- 15.3 to 74 +/- 12.0 beats/min, p = 0.0001, n = 141) and increase in stroke volume (59 +/- 20.6 to 77 +/- 19.8 ml, p = 0.0001, n = 132). Prosthetic Doppler echocardiographic findings demonstrated a reduction in blood flow velocity in the left ventricular outflow tract (VLVOT, 1.10 +/- 0.25 to 0.96 +/- 0.23 m/sec, p = 0.0001, n = 146) reduction in peak velocity (Vmax 2.72 +/- 0.53 to 2.59 +/- 0.54 m/sec, p = 0.02, n = 150), reduction in mean pressure gradient (deltaPmean, 18.4 +/- 7.2 to 16.3 +/- 7.3 mm Hg, p = 0.004) and an increase in velocity index (Vmax/VLVOT, 2.56 +/- 0.62 to 2.67 +/- 0.60, p = 0.003, n = 144). The standard deviations of difference between baseline and late investigation expressed as percentage of mean were 25% for VLVOT, 20% for Vmax, 44% for deltaPmean, and 25% for velocity index. In conclusion, this large reference base provides data that should be useful for the clinician evaluating patients with prosthetic valves early after valve replacement as well as at a later stage. When valve dysfunction is suspected a previous investigation for comparison is helpful, and our data describe the changes that normally may be seen between an early baseline and a late investigation.


Asunto(s)
Bioprótesis , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica , Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/fisiología , Ecocardiografía , Femenino , Estudios de Seguimiento , Hemodinámica/fisiología , Humanos , Masculino , Variaciones Dependientes del Observador , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Valores de Referencia , Factores de Tiempo
9.
J Am Soc Echocardiogr ; 13(1): 39-50, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10625830

RESUMEN

The extent to which Doppler echocardiography information can be used in the assessment of prosthesis hemodynamic performance is still controversial. The goals of our study were to assess the importance of valve design and size both on Doppler echocardiography findings and on pressure recovery in a fluid mechanics model. We performed Doppler and catheter measurements in the different orifices of the bileaflet St Jude (central and side orifices), the monoleaflet Omnicarbon (major and minor orifices), and the stented Biocor porcine prosthesis. Net pressure gradients were predicted from Doppler flow velocities, assuming either independence or dependence of valve size. The peak Doppler estimated gradients (mean +/- SD for sizes 21 to 27) were 21 +/- 10.3 mm Hg for St Jude, 18 +/- 9.3 mm Hg for Omnicarbon, and 37 +/- 14.5 mm Hg for Biocor (P <.05 for St Jude and Omnicarbon vs Biocor). The pressure recovery (proportion of peak catheter pressure) was 53% +/- 8.6% for central-St Jude, 29% +/- 8. 9% for side-St Jude, 20% +/- 5.6% for major-Omnicarbon, 23% +/- 7.4% for minor-Omnicarbon, and 18% +/- 3.6% for Biocor (P <.05 for central-St Jude and side-St Jude vs Omnicarbon and Biocor). Valve sizes (x) significantly influenced pressure recovery (y in percentage) (central-St Jude: y = 3.7x - 35.9, r = 0.88, P =.0001; major-Omnicarbon: y = 2.1x - 30.3, r = 0.85, P =.0001). By assuming dependence of valve size, Doppler was able to predict net pressure gradients in St Jude with a mean difference between net catheter and Doppler-predicted gradient of -3.8 +/- 2.5 mm Hg. In conclusion, prosthetic valve design and size influence the degree of pressure recovery, making Doppler gradients potentially misleading in both the assessment of hemodynamic performance and the comparison of one design with another. The preliminary results indicate that net gradient can be predicted from Doppler gradients.


Asunto(s)
Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Ecocardiografía Doppler , Técnicas In Vitro , Presión , Diseño de Prótesis
10.
J Heart Valve Dis ; 5(2): 128-35, 1996 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8665003

RESUMEN

BACKGROUND AND AIMS OF THE STUDY: Prosthesis size is known to have an effect on long term outcome after heart valve replacement. We evaluated 115 patients subjected to aortic valve replacement to assess the ability by preoperative echocardiography to identify patients having small aortic roots and thereby likely to receive a small prosthesis (size 19 or 21), previously shown to be associated with a worse prognosis. METHODS: From an initial part of the study (Group A), comprising 67 patients, we evaluated the influence of image quality on the accuracy for prediction of patients receiving a small prosthesis. In a second series of 48 patients (Group B), we tested the predictive value of various limits of aortic annulus diameter to define patients at risk of receiving a small prosthesis. RESULTS: The measurement of aortic annulus diameter in Group A gave a reasonable correlation to subsequent prosthetic dimension (r = 0.73, n = 59). However, there was a considerable variation of echocardiographic aortic annulus diameter among patients receiving prostheses of the same size. In Group B, an aortic annulus diameter of < or = 22 mm correctly identified 10 of 13 patients receiving a small prosthesis (sensitivity 77%). Twenty-two of 25 patients (88%) with an aortic annulus diameter > 22 mm received a large prosthesis. CONCLUSIONS: We conclude that the echocardiographic measurement of the aortic annulus diameter is a fairly sensitive method to identify patients receiving a small prosthesis. However, the predictive accuracy is dependent upon training as well as image quality. Furthermore, the value of planning in advance the type of prosthesis, annuloplasty or homograft for aortic valve replacement remains to be shown.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/ultraestructura , Ecocardiografía , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Pronóstico , Estudios Prospectivos , Diseño de Prótesis , Sensibilidad y Especificidad
11.
Clin Nephrol ; 6(4): 453-7, 1976 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-788979

RESUMEN

An 18-year-old woman taking an oral contraceptive was admitted to hospital because of a stroke due to occlusion of three branches of the right middle cerebral artery. She later developed renovascular hypertension due to occlusion of one of two renal arteries on the right side. Occlusion of the ceoliac artery was also found. The circumstances suggest that the occlusions were caused by multiple emboli, the source of which could not be identified. The kidney with the circulatory disturbance was shown to have a persistent abnormal renin secretion three and six months after the stroke, but the peripheral renin level was lower at the second investigation. Cardiac function studies revealed an alarming degree of left ventricular hypertrophy, and satisfactory blood pressure control could not be maintained despite increasing antihypertensive therapy. Surgical corrrction of the circulatory disturbance promptly led to normotension without drugs, and the patient has remained normotensive during the postoperative observation period of twelve months. The oral contraceptive was probably responsible for precipitating the vascular occlusions, but no predisposing factors or warning symptoms were present to identify this patient as being at risk.


PIP: The case history of an 18-year-old patient, who had been taking oral contraceptives for 2 years (ethinylestradiol 50 mcg, megestrol acetate 4 mg) and who developed multiple arterial occlusions and hypertension, is reported. Occlusion of the ceoliac artery was also found. The circumstances suggest that the occlusions were caused by multiple emboli of unknown source. The affected kidney was shown to have an abnormal renin secretion 3 and 6 months after the stroke, but the peripheral renin level was lower at the 6 month investigation. A large degree of left ventricular hypertrophy was seen. Blood pressure was still uncontrolled despite antihypertensive therapy. Surgery was performed on the affected kidney and normal perfusion restored. The patient then became normotensive, and has remained so for a 12-month period. Oral contraceptives were probably responsible for precipitating the vascular occlusion. Predisposing factors or warning symptoms were absent in this patient.


Asunto(s)
Arteriopatías Oclusivas/inducido químicamente , Anticonceptivos Orales Combinados , Anticonceptivos Orales , Etinilestradiol/efectos adversos , Hipertensión Renal/inducido químicamente , Megestrol/efectos adversos , Adolescente , Aortografía , Arteriopatías Oclusivas/diagnóstico por imagen , Arteria Celíaca/diagnóstico por imagen , Angiografía Cerebral , Femenino , Humanos , Embolia y Trombosis Intracraneal/inducido químicamente , Embolia y Trombosis Intracraneal/diagnóstico por imagen , Pruebas de Función Renal , Trasplante de Riñón , Obstrucción de la Arteria Renal/inducido químicamente , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/cirugía , Trasplante Autólogo
12.
Eur J Cardiothorac Surg ; 15(1): 24-30, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10077369

RESUMEN

OBJECTIVE: In patients with severe aortic stenosis, we studied the impact of gender on preoperative left ventricular geometry and function, as well as on early postoperative mortality and morbidity. METHODS: Prospective Doppler echocardiographic evaluation was performed in 99 female patients and 96 males. RESULTS: The patients had severe aortic stenosis and the mean pressure gradients were similar in females and males. Left ventricular diastolic volume adjusted for body surface area (BSA) was larger in males, 55+/-17.4 ml/m2 versus 43+/-13.1 mL/m2 (mean+/-standard deviation; P = 0.0001). The ejection fraction was similar in females (55+/-14%) and males (55+/-13%), and patients of both sexes had significantly lower stroke volume and cardiac index than healthy controls. The relative wall thickness (wall thickness/diastolic diameter ratio) was higher (P = 0.03) in females (0.47+/-0.10) than in males (0.43+/-0.10) Consequently, the diastolic diameter/wall thickness ratio (a substitute for wall tension) was higher (P = 0.02) in males (4.2+/-0.99) than in females (3.9+/-0.80). Compared with survivors, patients who died within 30 days of the operation (n = 17, 11 females) had a smaller body surface area (1.70+/-0.19 vs. 1.82+/-0.19 m2, P = 0.012), smaller left ventricular outflow tract (20.8+/-0.21 vs. 22.0+/-0.22 mm, P = 0.023), higher incidence of abnormal intraventricular flow velocity (33 vs. 8%, P = 0.018) and increased relative wall thickness (0.52+/-0.17 vs. 0.45+/-0.09 P = 0.039). Gender was of no independent importance for early mortality when age and left ventricular outflow tract diameter were accounted for. CONCLUSIONS: Cardiac adaptation to aortic stenosis seems to be influenced by gender, males presenting larger left ventricular volumes and higher wall tension. The echocardiographic findings of a narrow left ventricular outflow tract, abnormally increased intraventricular velocity and increased relative wall thickness identified patients with increased risk of early postoperative mortality. However gender had no independent impact on early postoperative outcome.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Ventrículos Cardíacos/fisiopatología , Caracteres Sexuales , Función Ventricular Izquierda , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Velocidad del Flujo Sanguíneo , Unidades de Cuidados Coronarios/estadística & datos numéricos , Ecocardiografía Doppler en Color , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Mortalidad Hospitalaria , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Variaciones Dependientes del Observador , Complicaciones Posoperatorias , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Resultado del Tratamiento
13.
Minerva Cardioangiol ; 44(7-8): 353-9, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8965991

RESUMEN

Our experience with primary malignant cardiac tumors is reviewed. Six adult patients were treated surgically during a 10-year period. A preoperative diagnosis of cardiac "tumor" was established in all cases by means of echocardiography. Surgery was possible in each case. Adjuvant therapy was also used. All patients died between 3 weeks and 43 months from the first operation. The importance of an aggressive surgical attitude and the role of adjuvant therapy is discussed.


Asunto(s)
Neoplasias Cardíacas , Adulto , Ecocardiografía , Resultado Fatal , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/mortalidad , Neoplasias Cardíacas/patología , Neoplasias Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias
14.
BMJ ; 315(7113): 912-6, 1997 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-9361540

RESUMEN

OBJECTIVES: To investigate the consequences of longstanding obesity on left ventricular mass and structure and to examine the effects of weight loss on these variables. DESIGN: Cross sectional survey and controlled intervention study. SETTING: City of Gothenburg and surrounding areas. Sweden. SUBJECTS: 41 obese patients treated with weight reducing gastric surgery, 31 obese patients treated conventionally, and 43 non-obese subjects. MAIN OUTCOME MEASURES: Changes in left ventricular mass and relative wall thickness. RESULTS: Obese patients had higher blood pressure, greater left ventricular mass, and increased relative wall thickness than did matched non-obese control subjects. Obese subjects treated with gastric surgery had a substantial weight loss and a significant reduction in all variables when compared with conventionally treated obese subjects. Univariate and multivariate analysis of pooled data from the two groups of obese subjects showed that changes in relative wall thickness and left ventricular mass were more closely related to the change in weight than to the concomitant change in blood pressure. CONCLUSIONS: Structural heart abnormalities occurring in conjunction with obesity diminish after weight loss. The regression in these structural aberrations is better predicted by the weight loss than by the accompanying reduction in blood pressure. To prevent or improve abnormalities of heart structure in obese people, weight control should be the primary goal; it should be regarded as at least as important as regulating blood pressure.


Asunto(s)
Ventrículos Cardíacos/patología , Obesidad/patología , Pérdida de Peso/fisiología , Adulto , Análisis de Varianza , Presión Sanguínea , Índice de Masa Corporal , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/fisiopatología , Obesidad/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA