Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38984417

RESUMEN

The rapid technological advancements in cardiac implantable electronic devices such as pacemakers, implantable cardioverter defibrillators, and loop recorders, coupled with a rise in the number of patients with these devices, necessitate an updated clinical framework for periprocedural management. The introduction of leadless pacemakers, subcutaneous and extravascular defibrillators, and novel device communication protocols underscores the imperative for clinical updates. This scientific statement provides an inclusive framework for the periprocedural management of patients with these devices, encompassing the planning phase, procedure, and subsequent care coordinated with the primary device managing clinic. Expert contributions from anesthesiologists, cardiac electrophysiologists, and cardiac nurses are consolidated to appraise current evidence, offer patient and health system management strategies, and highlight key areas for future research. The statement, pertinent to a wide range of health care professionals, underscores the importance of quality care pathways for patient safety, optimal device function, and minimization of hemodynamic disturbances or arrhythmias during procedures. Our primary objective is to deliver quality care to the expanding patient cohort with cardiac implanted electronic devices, offering direction in the era of evolving technologies and laying a foundation for sustained education and practice enhancement.

2.
Annu Rev Med ; 74: 55-64, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-35914765

RESUMEN

An estimated 10-15% of those infected with SARS-CoV-2 may have post-COVID-19 condition. Common lingering signs and symptoms include shortness of breath, fatigue, high heart rate, and memory and cognitive dysfunction even several months after infection, often impacting survivors' quality of life. The prevalence and duration of individual symptoms remain difficult to ascertain due to the lack of standardized research methods across various studies and limited patient follow-up in clinical studies. Nonetheless, data indicate post-COVID-19 condition may occur independent of acuity of initial infection, hospitalization status, age, or pre-existing comorbidities. Risk factors may include female sex and underlying respiratory or psychiatric disease. Supportive therapies to mitigate symptoms remain the mainstay of treatment. Reassuringly, most patients experience a reduction in symptoms by 1 year. The use of a universal case definition and shared research methods will allow for further clarity regarding the pervasiveness of this entity and its long-term health consequences.


Asunto(s)
COVID-19 , Disfunción Cognitiva , Humanos , Femenino , Calidad de Vida , SARS-CoV-2 , Disfunción Cognitiva/epidemiología , Disfunción Cognitiva/etiología , Disnea
3.
J Struct Biol ; : 108110, 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-39009246

RESUMEN

Atrial fibrillation (AF) is the most common clinical arrhythmia, however there is limited understanding of its pathophysiology including the cellular and ultrastructural changes rendered by the irregular rhythm, which limits pharmacological therapy development. Prior work has demonstrated the importance of reactive oxygen species (ROS) and mitochondrial dysfunction in the development of AF. Mitochondrial structure, interactions with other organelles such as sarcoplasmic reticulum (SR) and T-tubules (TT), and degradation of dysfunctional mitochondria via mitophagy are important processes to understand ultrastructural changes due to AF. However, most analysis of mitochondrial structure and interactome in AF has been limited to two-dimensional (2D) modalities such as transmission electron microscopy (EM), which does not fully visualize the morphological evolution of the mitochondria during mitophagy. Herein, we utilize focused ion beam-scanning electron microscopy (FIB-SEM) and perform reconstruction of three-dimensional (3D) EM from murine left atrial samples and measure the interactions of mitochondria with SR and TT. We developed a novel 3D quantitative analysis of FIB-SEM in a murine model of AF to quantify mitophagy stage, mitophagosome size in cardiomyocytes, and mitochondrial structural remodeling when compared with control mice. We show that in our murine model of spontaneous and continuous AF due to persistent late sodium current, left atrial cardiomyocytes have heterogenous mitochondria, with a significant number which are enlarged with increased elongation and structural complexity. Mitophagosomes in AF cardiomyocytes are located at Z-lines where they neighbor large, elongated mitochondria. Mitochondria in AF cardiomyocytes show increased organelle interaction, with 5X greater contact area with SR and are 4X as likely to interact with TT when compared to control. We show that mitophagy in AF cardiomyocytes involves 2.5X larger mitophagosomes that carry increased organelle contents. In conclusion, when oxidative stress overcomes compensatory mechanisms, mitophagy in AF faces a challenge of degrading bulky complex mitochondria, which may result in increased SR and TT contacts, perhaps allowing for mitochondrial Ca2+ maintenance and antioxidant production.

4.
J Cardiovasc Electrophysiol ; 35(1): 130-135, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37975539

RESUMEN

INTRODUCTION: Cavo-tricuspid isthmus (CTI) dependent atrial flutter (AFL) is one of the most common atrial arrhythmias involving the right atrium (RA) for which radiofrequency catheter ablation has been widely used as a therapy of choice. However, there is limited data on the effect of this intervention on cardiac size and function. METHODS: A retrospective study was conducted on 468 patients who underwent ablation for CTI dependent typical AFL at a single institution between 2010 and 2019. After excluding patients with congenital or rheumatic heart disease, heart transplant recipients, or those without baseline echocardiogram, a total of 130 patients were included in the analysis. Echocardiographic data were analyzed at baseline before ablation, and at early follow-up within 1-year postablation. Follow-up echocardiographic data was available for 55 patients. RESULTS: Of the 55 patients with CTI-AFL, the mean age was 64.2 ± 14.8 years old with 14.5% (n = 8) female. The average left ventricular ejection fraction (LVEF) significantly improved on follow-up echo (40.2 ± 16.9 to 50.4 ± 14.9%, p < .0001), of which 50% of patients had an improvement in LVEF of at least 10%. There was a significant reduction in left atrial volume index (82.74 ± 28.5 to 72.96 ± 28 mL/m2 , p = .008) and RA volume index (70.62 ± 25.6 to 64.15 ± 31 mL/m2 , p = .046), and a significant improvement in left atrial reservoir strain (13.04 ± 6.8 to 19.10 ± 7.7, p < .0001). CONCLUSIONS: Patients who underwent CTI dependent AFL ablation showed an improvement in cardiac size and function at follow-up evaluation. While long-term results are still unknown, these findings indicate that restoration of sinus rhythm in patients with typical AFL is associated with improvement in atrial size and left ventricular function.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 35(7): 1401-1411, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38738814

RESUMEN

INTRODUCTION: Ablation of scar-related reentrant atrial tachycardia (SRRAT) involves identification and ablation of a critical isthmus. A graph convolutional network (GCN) is a machine learning structure that is well-suited to analyze the irregularly-structured data obtained in mapping procedures and may be used to identify potential isthmuses. METHODS: Electroanatomic maps from 29 SRRATs were collected, and custom electrogram features assessing key tissue and wavefront properties were calculated for each point. Isthmuses were labeled off-line. Training data was used to determine the optimal GCN parameters and train the final model. Putative isthmus points were predicted in the training and test populations and grouped into proposed isthmus areas based on density and distance thresholds. The primary outcome was the distance between the centroids of the true and closest proposed isthmus areas. RESULTS: A total of 193 821 points were collected. Thirty isthmuses were detected in 29 tachycardias among 25 patients (median age 65.0, 5 women). The median (IQR) distance between true and the closest proposed isthmus area centroids was 8.2 (3.5, 14.4) mm in the training and 7.3 (2.8, 16.1) mm in the test group. The mean overlap in areas, measured by the Dice coefficient, was 11.5 ± 3.2% in the training group and 13.9 ± 4.6% in the test group. CONCLUSION: A GCN can be trained to identify isthmus areas in SRRATs and may help identify critical ablation targets.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Cicatriz , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Taquicardia Supraventricular , Humanos , Femenino , Masculino , Cicatriz/fisiopatología , Cicatriz/diagnóstico , Persona de Mediana Edad , Anciano , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Automatización , Aprendizaje Automático , Resultado del Tratamiento , Procesamiento de Señales Asistido por Computador
6.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38587017

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , América Latina , Resultado del Tratamiento , Catéteres , Asia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
7.
Am J Physiol Cell Physiol ; 322(1): C1-C11, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34817268

RESUMEN

SARS-CoV-2 has rapidly spread across the globe and infected hundreds of millions of people worldwide. As our experience with this virus continues to grow, our understanding of both short-term and long-term complications of infection with SARS-CoV-2 continues to grow as well. Just as there is heterogeneity in the acute infectious phase, there is heterogeneity in the long-term complications seen following COVID-19 illness. The purpose of this review article is to present the current literature with regards to the epidemiology, pathophysiology, and proposed management algorithms for the various long-term sequelae that have been observed in each organ system following infection with SARS-CoV-2. We will also consider future directions, with regards to newer variants of the virus and their potential impact on the long-term complications observed.


Asunto(s)
COVID-19/complicaciones , COVID-19/fisiopatología , SARS-CoV-2 , Algoritmos , COVID-19/etiología , Enfermedades Cardiovasculares/etiología , Enfermedades del Sistema Nervioso Central/etiología , Progresión de la Enfermedad , Enfermedades Hematológicas/etiología , Humanos , Síndrome Post Agudo de COVID-19
8.
J Cardiovasc Electrophysiol ; 31(12): 3086-3096, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33022765

RESUMEN

INTRODUCTION: Electrocardiographic characteristics in COVID-19-related mortality have not yet been reported, particularly in racial/ethnic minorities. METHODS AND RESULTS: We reviewed demographics, laboratory and cardiac tests, medications, and cardiac rhythm proximate to death or initiation of comfort care for patients hospitalized with a positive SARS-CoV-2 reverse-transcriptase polymerase chain reaction in three New York City hospitals between March 1 and April 3, 2020 who died. We described clinical characteristics and compared factors contributing toward arrhythmic versus nonarrhythmic death. Of 1258 patients screened, 133 died and were enrolled. Of these, 55.6% (74/133) were male, 69.9% (93/133) were racial/ethnic minorities, and 88.0% (117/133) had cardiovascular disease. The last cardiac rhythm recorded was VT or fibrillation in 5.3% (7/133), pulseless electrical activity in 7.5% (10/133), unspecified bradycardia in 0.8% (1/133), and asystole in 26.3% (35/133). Most 74.4% (99/133) died receiving comfort measures only. The most common abnormalities on admission electrocardiogram included abnormal QRS axis (25.8%), atrial fibrillation/flutter (14.3%), atrial ectopy (12.0%), and right bundle branch block (11.9%). During hospitalization, an additional 17.6% developed atrial ectopy, 14.7% ventricular ectopy, 10.1% atrial fibrillation/flutter, and 7.8% a right ventricular abnormality. Arrhythmic death was confirmed or suspected in 8.3% (11/133) associated with age, coronary artery disease, asthma, vasopressor use, longer admission corrected QT interval, and left bundle branch block (LBBB). CONCLUSIONS: Conduction, rhythm, and electrocardiographic abnormalities were common during COVID-19-related hospitalization. Arrhythmic death was associated with age, coronary artery disease, asthma, longer admission corrected QT interval, LBBB, ventricular ectopy, and usage of vasopressors. Most died receiving comfort measures.


Asunto(s)
Arritmias Cardíacas/mortalidad , COVID-19/mortalidad , Mortalidad Hospitalaria , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etnología , Arritmias Cardíacas/terapia , COVID-19/diagnóstico , COVID-19/etnología , COVID-19/terapia , Causas de Muerte , Comorbilidad , Electrocardiografía , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Mortalidad Hospitalaria/etnología , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Ciudad de Nueva York/epidemiología , Pronóstico , Factores Raciales , Estudios Retrospectivos , Medición de Riesgo , Factores de Tiempo
9.
J Cardiovasc Electrophysiol ; 31(6): 1249-1254, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32281214

RESUMEN

A global coronavirus (COVID-19) pandemic occurred at the start of 2020 and is already responsible for more than 74 000 deaths worldwide, just over 100 years after the influenza pandemic of 1918. At the center of the crisis is the highly infectious and deadly SARS-CoV-2, which has altered everything from individual daily lives to the global economy and our collective consciousness. Aside from the pulmonary manifestations of disease, there are likely to be several electrophysiologic (EP) sequelae of COVID-19 infection and its treatment, due to consequences of myocarditis and the use of QT-prolonging drugs. Most crucially, the surge in COVID-19 positive patients that have already overwhelmed the New York City hospital system requires conservation of hospital resources including personal protective equipment (PPE), reassignment of personnel, and reorganization of institutions, including the EP laboratory. In this proposal, we detail the specific protocol changes that our EP department has adopted during the COVID-19 pandemic, including performance of only urgent/emergent procedures, after hours/7-day per week laboratory operation, single attending-only cases to preserve PPE, appropriate use of PPE, telemedicine and video chat follow-up appointments, and daily conferences to collectively manage the clinical and ethical dilemmas to come. We discuss also discuss how we perform EP procedures on presumed COVID positive and COVID tested positive patients to highlight issues that others in the EP community may soon face in their own institution as the virus continues to spread nationally and internationally.


Asunto(s)
Centros Médicos Académicos/provisión & distribución , Betacoronavirus , Infecciones por Coronavirus/diagnóstico , Electrofisiología/métodos , Equipo de Protección Personal/normas , Neumonía Viral/diagnóstico , COVID-19 , Humanos , Pandemias , SARS-CoV-2
10.
Curr Cardiol Rep ; 23(1): 2, 2020 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-33231782

RESUMEN

PURPOSE OF REVIEW: Cardiac arrhythmias are known complications in patients with COVID-19 infection that may persist even after recovery from infection. A review of the spectrum of cardiac arrhythmias due to COVID-19 infection and current guidelines and assessment or risk and benefit of management considerations is necessary as the population of patients infected and covering from COVID-19 continues to grow. RECENT FINDINGS: Cardiac arrhythmias such as atrial fibrillation, supraventricular tachycardia, complete heart block, and ventricular tachycardia occur in patients infected, recovering and recovered from COVID-19. Personalized care while balancing risk/benefit of medical or invasive therapy is necessary to improve care of patients with arrhythmias. Providers must provide thorough follow-up care and use necessary precaution while caring for COVID-19 patients.


Asunto(s)
Fibrilación Atrial , COVID-19 , Taquicardia Supraventricular , Humanos , Pandemias , SARS-CoV-2 , Taquicardia Supraventricular/terapia
11.
Indian Pacing Electrophysiol J ; 20(6): 250-256, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32861812

RESUMEN

BACKGROUND: The COVID-19 pandemic has greatly altered the practice of cardiac electrophysiology around the world for the foreseeable future. Professional organizations have provided guidance for practitioners, but real-world examples of the consults and responsibilities cardiac electrophysiologists face during a surge of COVID-19 patients is lacking. METHODS: In this observational case series we report on 29 consecutive inpatient electrophysiology consultations at a major academic medical center in New York City, the epicenter of the pandemic in the United States, during a 2 week period from March 30-April 12, 2020, when 80% of hospital beds were occupied by COVID-19 patients, and the New York City metropolitan area accounted for 10% of COVID-19 cases worldwide. RESULTS: Reasons for consultation included: Atrial tachyarrhythmia (31%), cardiac implantable electronic device management (28%), bradycardia (14%), QTc prolongation (10%), ventricular arrhythmia (7%), post-transcatheter aortic valve replacement conduction abnormality (3.5%), ventricular pre-excitation (3.5%), and paroxysmal supraventricular tachycardia (3.5%). Twenty-four patients (86%) were positive for COVID-19 by nasopharyngeal swab. All elective procedures were canceled, and only one urgent device implantation was performed. Thirteen patients (45%) required in-person evaluation and the remainder were managed remotely. CONCLUSION: Our experience shows that the application of a massive alteration in workflow and personnel forced by the pandemic allowed our team to efficiently address the intersection of COVID-19 with a range of electrophysiology issues. This experience will prove useful as guidance for emerging hot spots or areas affected by future waves of the pandemic.

12.
Pacing Clin Electrophysiol ; 42(5): 542-547, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30829416

RESUMEN

BACKGROUND: Leadless pacemakers (LPMs) have been shown to have lower postoperative complications than traditional permanent pacemakers but there have been no studies on the outcomes of LPMs in patients with transcatheter heart valve replacements (THVRs). This study determined outcomes of LPMs compared to transvenous single-chamber pacemakers (SCPs) post-THVR. METHODS: This is a retrospective single-center study including 10 patients who received LPMs post-THVR between February 2017 and August 2018 and a comparison group of 23 patients who received SCP post-THVR between July 2008 and August 2018. LPM or SCP was implanted at the discretion of electrophysiologists for atrial fibrillation with slow ventricular response or sinus node dysfunction with need for single-chamber pacing only. RESULTS: LPMs were associated with decreased tricuspid regurgitation (P = 0.04) and decreased blood loss during implantation (7.5 ± 2.5 cc for LPMs vs 16.8 ± 3.2 cc for SCPs, P = 0.03). Five LPM patients had devices positioned in the right ventricular septum as seen on transthoracic echocardiogram. Frequency of ventricular pacing was similar between LPM and SCP groups. In the LPM group, one case was complicated by a pseudoaneurysm and one death was due to noncardiac causes. There was one pneumothorax and one pocket infection in the SCP group. CONCLUSIONS: In this small retrospective study, LPMs were feasible post-THVR and found to perform as well as SCPs, had less intraprocedural blood loss, and were associated with less tricuspid regurgitation. Further, larger studies are required to follow longer-term outcomes and complications.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Procedimientos Quirúrgicos Cardíacos , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide/prevención & control , Anciano de 80 o más Años , Ecocardiografía , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos
13.
J Interv Card Electrophysiol ; 67(2): 409-424, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38038816

RESUMEN

BACKGROUND: Esophageal perforation and fistula formation are rare but serious complications following atrial fibrillation ablation. In this review article, we outline the incidence, pathophysiology, predictors, and preventative strategies of this dreaded complication. METHODS: We conducted an electronic search in 10 databases/electronic search engines to access relevant publications. All articles reporting complications following atrial fibrillation ablation, including esophageal injury and fistula formation, were included for systematic review. RESULTS: A total of 130 manuscripts were identified for the final review process. The overall incidence of esophageal injury following atrial fibrillation ablation was significantly higher with thermal ablation modalities (radiofrequency 5-40%, cryoballoon 3-25%, high-intensity focused ultrasound < 10%) as opposed to non-thermal ablation modalities (no cases reported to date). The incidence of esophageal perforation and fistula formation with the use of thermal ablation modalities is estimated to occur in less than 0.25% of all atrial fibrillation ablation procedures. The use of luminal esophageal temperature monitoring probe and mechanical esophageal deviation showed protective effect toward reducing the incidence of this complication. The prognosis is very poor for patients who develop atrioesophageal fistula, and the condition is rapidly fatal without surgical intervention. CONCLUSIONS: Esophageal perforation and fistula formation following atrial fibrillation ablation are rare complications with poor prognosis. Various strategies have been proposed to protect the esophagus and reduce the incidence of this fearful complication. Pulsed field ablation is a promising new ablation technology that may be the future answer toward reducing the incidence of esophageal complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula Esofágica , Perforación del Esófago , Humanos , Perforación del Esófago/complicaciones , Perforación del Esófago/cirugía , Fístula Esofágica/epidemiología , Fístula Esofágica/etiología , Fístula Esofágica/cirugía , Pronóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía
14.
Cardiovasc Digit Health J ; 5(3): 141-148, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38989041

RESUMEN

Background: Despite near-global availability of remote monitoring (RM) in patients with cardiac implantable electronic devices (CIED), there is a high geographical variability in the uptake and use of RM. The underlying reasons for this geographic disparity remain largely unknown. Objectives: To study the determinants of worldwide RM utilization and identify locoregional barriers of RM uptake. Methods: An international survey was administered to all CIED clinic personnel using the Heart Rhythm Society global network collecting demographic information, as well as information on the use of RM, the organization of the CIED clinic, and details on local reimbursement and clinic funding. The most complete response from each center was included in the current analysis. Stepwise forward multivariate linear regression was performed to identify determinants of the percentage of patients with a CIED on RM. Results: A total of 302 responses from 47 different countries were included, 61.3% by physicians and 62.3% from hospital-based CIED clinics. The median percentage of CIED patients on RM was 80% (interquartile range, 40-90). Predictors of RM use were gross national income per capita (0.76% per US$1000, 95% CI 0.72-1.00, P < .001), office-based clinics (7.48%, 95% CI 1.53-13.44, P = .014), and presence of clinic funding (per-patient payment model 7.90% [95% CI 0.63-15.17, P = .033); global budget 3.56% (95% CI -6.14 to 13.25, P = .471]). Conclusion: The high variability in RM utilization can partly be explained by economic and structural barriers that may warrant specific efforts by all stakeholders to increase RM utilization.

15.
Am J Cardiol ; 213: 146-150, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38008349

RESUMEN

Successful synchronized direct current cardioversion (DCCV) requires adequate current delivery to the heart. However, adequate current for successful DCCV has not yet been established. Transmyocardial current depends on 2 factors: input energy and transthoracic impedance (TTI). Although factors affecting TTI have been studied in animal models, factors affecting TTI in humans have not been well established. Herein, we explored the potential factors that affect TTI in humans. A retrospective review of patients who underwent DCCV at a large quaternary medical center between October 2019 and August 2021 was conducted. Pertinent clinical information, including demographics, echocardiography findings, laboratory findings, and body characteristics, was collected. Cardioversion details, including joules delivered and TTI, were recorded by the defibrillator for each patient's first shock. Predictors of thoracic impedance were assessed using regression analysis. A total of 220 patients (29% women) were included in the analysis; 143 of the patients (65%) underwent DCCV for atrial fibrillation and 77 (35%) underwent DCCV for atrial flutter. The mean impedance in our population was 73 ± 18 Ω. In a regression model with high impedance defined as the upper quartile of our cohort, body mass index (BMI), female sex, obstructive sleep apnea, and chronic kidney disease (all p values <0.05) were significantly associated with high impedance. According to a receiver operating characteristic analysis, BMI has a high predictive value for high impedance, with an area under the curve of 0.76. In conclusion, our study reveals that elevated BMI, female sex, sleep apnea, and chronic kidney disease were predictors of higher TTI. These factors may help determine the appropriate initial shock energy in patients who underwent DCCV for atrial fibrillation and flutter.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Insuficiencia Renal Crónica , Humanos , Femenino , Masculino , Cardioversión Eléctrica , Fibrilación Atrial/complicaciones , Cardiografía de Impedancia , Aleteo Atrial/terapia , Insuficiencia Renal Crónica/complicaciones
16.
Heart Rhythm ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38597857

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

17.
Artículo en Inglés | MEDLINE | ID: mdl-38609733

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

18.
IEEE Trans Biomed Eng ; 70(3): 853-859, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36049009

RESUMEN

Conventional biventricular (BiV) pacing cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. Recently, multiple novel CRT delivering technologies such as His-Bundle pacing have been investigated as alternative pacing strategies for optimal treatment benefit. Electromechanical Wave Imaging (EWI), a high frame-rate echocardiography-based modality, is capable of visualizing the change from dyssynchronous activation to resynchronized BiV-paced ventricles in 3D. This proof-of-concept study introduces a new EWI-based dispersion metric to further characterize ventricular activation. Patients with His-Bundle device implantation (n = 4), left-bundle branch block (n = 10), right-ventricular (RV) pacing (n = 10), or BiV pacing (n = 15) were imaged, as well as four volunteers in normal sinus rhythm (NSR). EWI successfully mapped the ventricular activation resulting from His-Bundle pacing. Additionally, very similar activation patterns were obtained in the NSR subjects, confirming recovery of physiological activation with His pacing. The dispersion metric was the most sensitive EWI-based metric that identified His pacing as the most efficient treatment (lowest activation time spread), followed by BiV and RV pacing. More specifically, the dispersion metric significantly (p < 0.005) distinguished His pacing from the other two pacing schemes as well as LBBB. The initial findings presented herein indicate that EWI and its new dispersion metric may provide a useful resynchronization evaluation clinical tool in CRT patients under both novel His-Bundle pacing and more conventional BiV pacing strategies.


Asunto(s)
Terapia de Resincronización Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Ecocardiografía , Arritmias Cardíacas
19.
J Interv Card Electrophysiol ; 66(8): 1939-1953, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36929368

RESUMEN

BACKGROUND: The current COVID-19 pandemic has led to many studies examining its arrhythmogenic effects. However, there are many other viruses that are capable of inducing arrhythmias that have not received as much attention. The objective of this study was to review common viruses and identify studies highlighting their arrhythmogenic effects. METHODS AND RESULTS: In this review, we examined 15 viruses and the literature regarding their arrhythmogenic effects. The common mechanisms of action appear to be direct invasion of myocytes leading to immune mediated damage, infection of vascular endothelium, and alteration of cardiac ion channels. CONCLUSIONS: This review highlights the growing evidence that supports the involvement of other viral infections in the development of arrhythmia. Physicians should be aware of these potentially life-threatening effects when caring for patients with these viruses, some of which are very common. Additional studies are required to better understand the complex mechanism and risk factors of cardiac arrhythmias in patients suffered from viral infections to determine whether the processes can be reversed or even prevented.


Asunto(s)
Pandemias , Virosis , Humanos , Arritmias Cardíacas/etiología , Factores de Riesgo , Virosis/complicaciones
20.
Heart Rhythm O2 ; 4(3): 171-179, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36993911

RESUMEN

Background: Prolongation of the PR interval has long been considered a benign condition, particularly in the setting of nonstructural heart disease. Objective: The purpose of this study was to investigate the effect of PR interval on various well-adjudicated cardiovascular outcomes using a large real-world population data of patients with implanted dual-chamber permanent pacemakers or implantable cardioverter-defibrillators. Methods: PR intervals were measured during remote transmissions in patients with implanted permanent pacemakers or implantable cardioverter-defibrillators. Study endpoints (time to the first occurrence of AF, heart failure hospitalization [HFH], or death) were obtained between January 2007 and June 2019 from the deidentified Optum de-identified Electronic Health Record dataset. Results: A total of 25,752 patients (age 69.3 ± 13.9 years; 58% male) were evaluated. The average intrinsic PR interval was 185 ± 55 ms. In the subset of 16,730 patients with available long-term device diagnostic data, a total of 2555 (15.3%) individuals developed AF during 2.59 ± 2.18 years of follow-up. The incidence of AF was significantly higher (up to 30%) in patients with a longer PR interval (ie, PR interval ≥270 ms; P < .05). Time-to-event survival analysis and multivariable analysis showed that PR interval ≥190 ms was significantly associated with higher incidence of AF, HFH, or HFH or death when compared with shorter PR intervals (P < .05 for all 3 parameters). Conclusion: In a large real-world population of patients with implanted devices, PR interval prolongation was significantly associated with increased incidence of AF, HFH, or death.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA