Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am Heart J ; 269: 1-7, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38109984

RESUMEN

BACKGROUND: Previous studies have examined the impact of antithrombotic agents on Patent Foramen Ovale (PFO) in relation to migraine. However, differences in effectiveness of different antithrombotic agents and traditional migraine medications are not known. METHODS/DESIGN: This study is an investigator-initiated, randomized, multicenter, single-masked (outcomes assessor), and active-controlled parallel-group trial (ClinicalTrials.gov Identifier: NCT05546320), with the objective of evaluating the prevention efficacy of antithrombotic agents compared to first-line migraine medication in PFO patients. The trial involves 1,000 migraine patients with a right-to-left shunt at the atrial level, randomized in a 1:1:1:1 fashion to receive either aspirin 300 mg QD, clopidogrel 75 mg QD, rivaroxaban 20 mg QD, or the active-control metoprolol 25 mg BID. The primary efficacy end point is the response rate, defined as a 50% or greater reduction in the average migraine attack days per month or in the average number of migraine attacks per month at 12-week visit compared to baseline. CONCLUSIONS: The COMPETE trial aims to provide valuable insights into the comparative effectiveness of antithrombotic agents and standard migraine therapies in patients with PFO. This study holds the promise of advancing treatment approaches for individuals having migraines associated with PFO, thus addressing an important gap in current migraine management strategies.


Asunto(s)
Foramen Oval Permeable , Trastornos Migrañosos , Humanos , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/tratamiento farmacológico , Fibrinolíticos , Trastornos Migrañosos/complicaciones , Trastornos Migrañosos/tratamiento farmacológico , Proyectos de Investigación , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 103(7): 1148-1151, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38639161

RESUMEN

The transcatheter edge-to-edge mitral valve repair (TEER) has been recommended as a reliable treatment option for selected patients with severe degenerative and functional mitral regurgitation (MR). Although MR patients with rheumatic etiology were excluded from two significant trials (EVEREST II and COAPT) that established a role for the TEER in degenerative and functional MR. However, it has been reported that the TEER procedure could be safely and effectively performed in carefully selected rheumatic MR patients. Therefore, we share a case report of successfully treating severe rheumatic MR using a novel-designed TEER system (JensClipTM).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Cardiopatía Reumática , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/etiología , Cateterismo Cardíaco/instrumentación , Resultado del Tratamiento , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/cirugía , Cardiopatía Reumática/fisiopatología , Cardiopatía Reumática/terapia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Femenino , Ecocardiografía Transesofágica , Ecocardiografía Doppler en Color , Diseño de Prótesis , Prótesis Valvulares Cardíacas , Persona de Mediana Edad , Masculino
3.
Cancer ; 129(24): 3873-3883, 2023 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-37538036

RESUMEN

BACKGROUND: TP53 mutation heterogeneity should be considered when using TP53 as a predictive biomarker for anti-programmed death (ligand) 1 (PD-(L)1) monotherapy in lung adenocarcinoma (LUAD). However, whether TP53 variant allele frequency (VAF) should also be considered remains unknown. METHODS: Patients with LUAD from both published research and the local cohort were included to discover and validate the relationship between TP53 VAF and the efficacy of PD-(L)1 inhibitors. The Cancer Genome Atlas (TCGA) LUAD data were included for genomic, transcriptomic, and tumor microenvironment analysis. RESULTS: Among 159 patients in the discovery cohort, low TP53 VAF patients (VAF ≤ 25%) experienced significantly longer progression-free survival (PFS) than both high TP53 VAF (5.4 vs. 3.3 months; p = .021) and TP53-wild-type patients (5.4 vs. 2.5 months; p = .011). Multivariate Cox regression revealed low TP53 VAF as an independent biomarker of better efficacy. Among 50 patients in the combined validation cohort, median PFS of low TP53 VAF patients was also significantly longer than that of high TP53 VAF patients (12.0 vs. 2.1 months; p = .037). Analyzed with 469 TCGA LUAD samples, low TP53 VAF is associated with significantly higher PD-L1 expression, enrichment of gene sets related to T-cell activation, T cell-mediated immunity, and interferon-γ signaling pathways, and independently associated with more tumor-infiltrating CD8+ T cells compared with both high TP53 VAF and TP53-wild type. CONCLUSIONS: TP53 VAF should also be considered when using TP53 as a predictive biomarker. Only low TP53 VAF is independently associated with better efficacy of anti-PD-(L)1 monotherapy, which may result from higher PD-L1 expression and more tumor-infiltrating CD8+ T cells.


Asunto(s)
Adenocarcinoma del Pulmón , Neoplasias Pulmonares , Humanos , Antígeno B7-H1/genética , Linfocitos T CD8-positivos , Ligandos , Adenocarcinoma del Pulmón/tratamiento farmacológico , Adenocarcinoma del Pulmón/genética , Biomarcadores de Tumor/genética , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Frecuencia de los Genes , Mutación , Microambiente Tumoral/genética , Proteína p53 Supresora de Tumor/genética
4.
J Card Surg ; 37(5): 1242-1249, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35220611

RESUMEN

BACKGROUND: Severe mitral regurgitation (MR) is associated with progressive heart failure and impairment of survival. Degenerative MR accounts for most MV repair surgeries. Conventional mitral valve repair surgery requires cardiopulmonary bypass and is associated with significant morbidity and risks. Transapical beating-heart mitral valve repair by artificial chordae implantation with transesophageal echocardiography (TEE) guidance has the potential to significantly reduce surgical morbidity. We report the first-in-human experience of degenerative MR repair using a novel artificial chordae implantation device (MitralstitchTM system). METHODS: Ten patients with severe MR underwent transapical artificial chordae implantation using MitralstitchTM system. The procedure was performed through a small left thoracotomy under general anesthesia and TEE guidance. Patients underwent transthoracic echocardiography and other assessments during the follow-up. RESULTS: All 10 patients with an average age of 63.7 ± 9.6 years successfully received transapical artificial chordae implantation. Their MR reduced from severe to none or trace in five patients, mild in five patients before discharge. Five patients received one artificial chordal implantation, four patients received two, and one patient received three and edge-to-edge repair by locking two of them. The safety and efficacy endpoint were achieved in all patients at 1-month follow-up. At 1-year follow-up, six patients had mild MR, three patients had moderate MR, one patient had recurrence of severe MR and underwent surgical repair. CONCLUSIONS: The results of this first-in-human study show safety and feasibility of transapical mitral valve repair using MitralStitch system. Patient selection and technical refinement are crucial to improve the outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Anciano , Cuerdas Tendinosas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Persona de Mediana Edad , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Resultado del Tratamiento
5.
J Interv Cardiol ; 31(6): 841-848, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30079559

RESUMEN

OBJECTIVE: To evaluate the feasibility, efficacy, and safety of a fully biodegradable poly lactic acid (PLA)-based occluder for atrial septal defect (ASD) closure in an animal model. METHODS: ASDs, approximately 12-mm in diameter, were generated in sheep (n = 18) by needle puncture and balloon dilatation. For ASD closure, occluders were implanted by percutaneous transcatheter approach under echocardiographic guidance. Outcomes were evaluated by transthoracic echocardiography, electrocardiography, blood testing, and histology within the follow-up period ranging from 1 month to 2 years. RESULTS: All occluders were successfully implanted. During follow-up, no animal died; rectal temperatures, blood test results, and electrocardiograms were within normal ranges; and transthoracic echocardiograms, macroscopic studies, and histopathological and electron microscopic examination demonstrated that the occluders were well positioned, with no shifting, residual shunts, severe inflammation, thrombus formation, atrioventricular valve insufficiency, cardiac erosion or arrhythmias. The occluders gradually embedded into the endocardial tissue of the hosts with complete endothelialization and disk absorption at 12 months, and a distinct molecular weight decrease of the framework (to 9% of initial) at 24 months after implantation. CONCLUSIONS: In a sheep model, the use of totally biodegradable occluders appears feasible, efficacious and safe for ASD closure. Studies in humans are ongoing.


Asunto(s)
Implantes Absorbibles , Defectos del Tabique Interatrial/cirugía , Diseño de Prótesis/métodos , Dispositivo Oclusor Septal , Animales , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Modelos Animales de Enfermedad , Ecocardiografía , Electrocardiografía , Estudios de Seguimiento , Poliésteres/efectos adversos , Poliésteres/farmacología , Ovinos , Resultado del Tratamiento
6.
Echocardiography ; 35(10): 1507-1511, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29920758

RESUMEN

OBJECTIVE: Percutaneous balloon mitral valvuloplasty (PBMV) is the treatment of choice in patients with isolated mitral stenosis. This study aimed to assess the feasibility of PBMV under echocardiography guidance only of isolated mitral stenosis (MS). METHODS: From October 2016 to Dec 2017, 20 consecutive patients with severe MS underwent PBMV with echocardiography as the only imaging modality at a single center. Outpatient follow-up including chest radiography, electrocardiography, and transthoracic echocardiography was conducted at 1, 3,6, and 12 months after the procedure. RESULTS: All 20 patients successfully underwent PBMV under echocardiography guidance without radiation and contrast agent. Among them, 2 patients were pregnant, 5 had chronic renal failure, and 1 had history of allergy to contrast. Mitral transvalvular pressure gradient measured at catheterization dropped from 13.35 ± 2.85 mm Hg to 5.10 ± 1.17 mm Hg (P < .01). Mitral valve area increased from 0.82 ± 0.10 cm2 pre-PBMV to 1.88 ± 0.24 cm2 post-PBMV (P < .01). Mean balloon diameter was 26.63 ± 0.93 mm. Mild mitral regurgitation developed in 6 patients. Mean follow-up duration was 6.27 ± 3.12 months. At last follow-up, mitral valve area remained high (1.71 ± 0.14 cm2 ) and mean transmitral pressure gradient low (6.07 ± 1.03 mm Hg). No pericardial effusion or peripheral vascular complications occurred. CONCLUSION: In this small experience, PBMV could be successfully performed under only echocardiography guidance and appeared safe and effective while avoiding radiation and contrast agent use.


Asunto(s)
Valvuloplastia con Balón/métodos , Ecocardiografía/métodos , Estenosis de la Válvula Mitral/terapia , Válvula Mitral/diagnóstico por imagen , Radiología Intervencionista/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Resultado del Tratamiento
8.
Echocardiography ; 33(7): 1040-5, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27038152

RESUMEN

INTRODUCTION: Percutaneous patent ductus arteriosus (PDA) occlusion has become the preferred therapeutic option, which uses fluoroscopy as the guidance. To reduce the x-ray exposure, PDA occlusion using the Amplatzer Duct Occluder II (ADO II) under guidance of transthoracic echocardiography only was conducted. This single center study aims to access the safety and efficiency of this new strategy. METHODS AND RESULTS: From June 2013 to May 2015, 63 consecutive PDA patients underwent transthoracic echocardiography-guided PDA occlusion through the femoral artery. Outpatient follow-up was conducted at 1, 3, and 6 months, and yearly. Sixty-two patients successfully underwent echocardiography-guided percutaneous PDA occlusion. One patient was converted to minimally invasive transthoracic occlusion due to failure of delivery sheath passage through tortuous PDA. Mean procedure duration was 24.3 ± 7.0 minutes; ADO II diameter averaged 4.6 ± 0.9 mm; 8 cases showed traces of residual shunt immediately after operation which resolved after 24 hours; and mean hospital stay was 3.4 ± 0.5 days. There was no occluder migration, hemolysis, pericardial effusion, pulmonary branch or aortic stenosis at mean 13.5 ± 4.8 months follow-up. CONCLUSIONS: This study demonstrated that percutaneous PDA occlusion can be successfully performed under guidance of transthoracic echocardiography only and appears safe and effective while avoiding radiation and contrast agent use.


Asunto(s)
Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/cirugía , Ecocardiografía/métodos , Dispositivo Oclusor Septal , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Preescolar , Femenino , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Diseño de Prótesis , Procedimientos de Cirugía Plástica/métodos , Resultado del Tratamiento
9.
J Interv Cardiol ; 28(4): 390-5, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26077469

RESUMEN

OBJECTIVE: Demonstrate the benefits of percutaneous atrial septal defect (ASD) closure under guidance of transthoracic echocardiography (TTE) without fluoroscopy. METHODS: From February 2013 to April 2014, 127 consecutive patients with an isolated type II ASD were recruited to undergo percutaneous closure under either TTE (n = 60, TTE group) or TEE (n = 67, TEE group) guidance. The TTE group received local anesthesia or sedation with propofol, and the TEE group received general anesthesia with endotracheal intubation. Follow-up examinations were performed for both groups at 1 month, 3 months, 6 months, and 1 year after discharge and annually thereafter. RESULTS: The TTE group had a significantly shorter procedure time and respirator ventilation duration than the TEE group. The dose of propofol required, the cost, and the pharyngeal complication rate were significantly lower in the TTE group than in the TEE group. The median follow-up of 11.6 months was uneventful in all patients. CONCLUSIONS: Percutaneous ASD closure with TTE guidance as the only imaging tool avoids fluoroscopy, endotracheal intubation, and probe insertion and is associated with a satisfactory procedural success rate and lower costs. This procedure is a safe and reliable treatment for ASD.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia , Dispositivo Oclusor Septal , Anestesia General , Anestesia Local , Niño , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Humanos , Hipnóticos y Sedantes/administración & dosificación , Intubación Intratraqueal , Masculino , Propofol/administración & dosificación , Estudios Retrospectivos
10.
Zhonghua Yi Xue Za Zhi ; 95(27): 2183-5, 2015 Jul 21.
Artículo en Zh | MEDLINE | ID: mdl-26710908

RESUMEN

OBJECTIVE: To avoid the injuries of radiation and contrast agent, we assess the efficacy and safety of percutaneous patent ductus arteriosus (PDA) closure by femoral vein approach solely under echocardiography guidance. METHODS: From January 2014 to December 2014, 25 patients in Fuwai hospital with PDA were selected, with mean age (4.5 ± 2.1) years and mean body weight (19 ± 7) kg. The mean diameter of PDA was (5.9 ± 1.2) mm. Patients were all treated by percutaneous PDA closure solely by echocardiography guidance in femoral vein. The effect of the procedure was evaluated by echocardiography. Follow-up was given at one month after procedure. RESULTS: Twenty-three cases were successfully treated with percutaneous PDA closure by femoral vein approach solely under echocardiography guidance, while two patients was closed by femoral artery approach because guide wires could not pass through PDA. The procedural time was (33 ± 5) min. The mean diameter of PDA occluder was (11.4 ± 1.5) mm. Postoperative early trivial residual shunt occurred in three patients. All patients survived with no peripheral vascular injury or complications such as cardiac perforation. Hospitalization time was (3.6 ± 0.8) days. At one month follow-up, no complications such as residual shunt or pericardial effusion were occurred. CONCLUSION: Echocardiography guided percutaneous PDA closure by femoral vein approach is safe and effective, and avoids the use of radiation and contrast agents.


Asunto(s)
Conducto Arterioso Permeable , Ecocardiografía , Vena Femoral , Peso Corporal , Cateterismo , Preescolar , Estudios de Seguimiento , Hospitalización , Hospitales , Humanos , Derrame Pericárdico , Periodo Posoperatorio , Prótesis e Implantes , Seguridad , Lesiones del Sistema Vascular
11.
JACC Case Rep ; 29(10): 102334, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38601843

RESUMEN

Transcatheter edge-to-edge repair (TEER) has been established as a safe and effective option for treating patients with severe symptomatic degenerative mitral regurgitation (MR) who are at prohibitive surgical risk. However, the significant cost presents a considerable disease burden in low-income countries. This case details the treatment of a high-surgical-risk patient with severe degenerative MR by using the GeminiOne (Peijia Medical) system-a novel Chinese TEER device.

12.
Int J Cardiol ; 395: 131561, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37913964

RESUMEN

BACKGROUND: The global and national burden of rheumatic mitral valve disease (MVD) has been well studied and estimated before. However, little is known about non-rheumatic degenerative MVD. Therefore, this study aimed to assess the trends in non-rheumatic degenerative MVD (NRDMVD) epidemiology, with an emphasis on NRDMVD mortality, leading risk factors, and their associations with age, period, and birth cohort. METHODS: Using the data derived from the Global Burden of Disease Study 2019, including prevalence, mortality, and disability-adjusted life years, we analyzed the burden of NRDMVD and the detailed trends of NRDMVD mortality over the past 30 years in 204 countries and territories by implementing the age-period-cohort framework. RESULTS: Globally, the number of deaths due to NRDMVD increased from 5695.89 (95% uncertainty interval [UI]: 5405.19 to 5895.4) × 1000 in 1990 to 9137.79 (95% UI: 8395.68 to 9743.55) × 1000 in 2019. The all-age mortality rate increased from 106.47 (95% UI: 101.03 to 110.2) per 100,000 to 118.1 (95% UI: 108.51 to 125.93) per 100,000, whereas the age-standardized mortality rate decreased from 170.45 (95% UI: 159.61 to 176.94) per 100,000 to 117.95 (95% UI: 107.83 to 125.92) per 100,000. The estimated net drift of mortality per year was -1.1% (95% confidence interval: -1.17 to -1.04). The risk of death due to NRDMVD increased with age, reaching its peak after 85 years old globally. Despite female patients being associated with lower local drift than male patients, no significant gender differences were observed in the age effect across countries and regions for all sociodemographic index (SDI) levels, except low-SDI regions. CONCLUSIONS: We estimated the global disease prevalence of and mortality due to NRDMVD over approximately a 30-year period. The health-related burden of NRDMVD has declined worldwide; however, the condition persisted in low-SDI regions. Moreover, higher attention should be paid to female patients.


Asunto(s)
Carga Global de Enfermedades , Válvula Mitral , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Factores de Riesgo , Distribución por Sexo , Salud Global , Prevalencia , Estudios de Cohortes , Años de Vida Ajustados por Calidad de Vida , Incidencia
13.
Adv Sci (Weinh) ; 11(2): e2305967, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37984880

RESUMEN

Transcatheter intervention has been the preferred treatment for congenital structural heart diseases by implanting occluders into the heart defect site through minimally invasive access. Biodegradable polymers provide a promising alternative for cardiovascular implants by conferring therapeutic function and eliminating long-term complications, but inducing in situ cardiac tissue regeneration remains a substantial clinical challenge. PGAG (polydioxanone/poly (l-lactic acid)-gelatin-A5G81) occluders are prepared by covalently conjugating biomolecules composed of gelatin and layer adhesive protein-derived peptides (A5G81) to the surface of polydioxanone and poly (l-lactic acid) fibers. The polymer microfiber-biomacromolecule-peptide frame with biophysical and biochemical cues could orchestrate the biomaterial-host cell interactions, by recruiting endogenous endothelial cells, promoting their adhesion and proliferation, and polarizing immune cells into anti-inflammatory phenotypes and augmenting the release of reparative cytokines. In a porcine atrial septal defect (ASD) model, PGAG occluders promote in situ tissue regeneration by accelerating surface endothelialization and regulating immune response, which mitigate inflammation and fibrosis formation, and facilitate the fusion of occluder with surrounding heart tissue. Collectively, this work highlights the modulation of cell-biomaterial interactions for tissue regeneration in cardiac defect models, ensuring endothelialization and extracellular matrix remodeling on polymeric scaffolds. Bioinspired cell-material interface offers a highly efficient and generalized approach for constructing bioactive coatings on medical devices.


Asunto(s)
Gelatina , Dispositivo Oclusor Septal , Animales , Porcinos , Gelatina/química , Polidioxanona , Células Endoteliales , Polímeros , Materiales Biocompatibles , Ácido Láctico , Péptidos
14.
ESC Heart Fail ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937863

RESUMEN

AIMS: This study aimed to analyse the global prevalence and disability trends of heart failure (HF) from 1990 to 2019, considering both sexes and country-specific economic strata. METHODS: This study conducted a secondary analysis employing data from the Global Burden of Disease (GBD) study. The analysis is stratified by sex and Socio-demographic Index (SDI) levels. Through age-period-cohort and Joinpoint regression analyses, we investigated the temporal trends in HF prevalence and years lived with disability (YLDs) during this period. RESULTS: Between 1990 and 2019, the global prevalence of HF surged by 106.3% (95% uncertainty interval: 99.3% to 114.3%), reaching 56.2 million cases in 2019. While all-age prevalence and YLDs increased over the 30 year span, age-standardized rates decreased by 2019. Countries with higher SDI experienced a more pronounced percentage decrease compared with those with lower SDI. Longitudinal analysis revealed an overall improvement in both prevalence and YLDs for HF, albeit with notable disparities between SDI quintiles and sexes. Ischaemic heart disease and hypertensive heart disease emerged as the most rapidly increasing and primarily contributing causes of HF, albeit with variations observed across different countries. The average annual percentage change for prevalence and YLDs over the period was -0.26% and -0.25%, respectively. CONCLUSIONS: This study offers valuable insights into the global burden of HF, considering factors such as population aging, regional disparities, sex differences and aetiological variations. The findings hold significant implications for healthcare planning and resource allocation. Continued assessment of these trends and innovative strategies for HF prevention and management are crucial for addressing this pressing global health concern.

15.
Interdiscip Sci ; 15(4): 653-662, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37470945

RESUMEN

PURPOSE: Studies relating to the right ventricle (RV) are inadequate, and specific diagnostic algorithms still need to be improved. This essay is designed to make exploration and verification on an algorithm of deep learning based on imaging and clinical data to detect RV abnormalities. METHODS: The Automated Cardiac Diagnosis Challenge dataset includes 20 subjects with RV abnormalities (an RV cavity volume which is higher than 110 mL/m2 or RV ejection fraction which is lower than 40%) and 20 normal subjects who suffered from both cardiac MRI. The subjects were separated into training and validation sets in a ratio of 7:3 and were modeled by utilizing a nerve net of deep-learning and six machine-learning algorithms. Eight MRI specialists from multiple centers independently determined whether each subject in the validation group had RV abnormalities. Model performance was evaluated based on the AUC, accuracy, recall, sensitivity and specificity. Furthermore, a preliminary assessment of patient disease risk was performed based on clinical information using a nomogram. RESULTS: The deep-learning neural network outperformed the other six machine-learning algorithms, with an AUC value of 1 (95% confidence interval: 1-1) on both training group and validation group. This algorithm surpassed most human experts (87.5%). In addition, the nomogram model could evaluate a population with a disease risk of 0.2-0.8. CONCLUSIONS: A deep-learning algorithm could effectively identify patients with RV abnormalities. This AI algorithm developed specifically for right ventricular abnormalities will improve the detection of right ventricular abnormalities at all levels of care units and facilitate the timely diagnosis and treatment of related diseases. In addition, this study is the first to validate the algorithm's ability to classify RV abnormalities by comparing it with human experts.

16.
J Thorac Dis ; 15(4): 2079-2097, 2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37197484

RESUMEN

Background: Non-rheumatic heart valve disease (NRVD) is a common cardiovascular disease, whereas calcific aortic valve disease (CAVD) is a type of disease with the fastest-growing mortality and disability-adjusted life years (DALYs). This study presents an overview of the trends noted in the DALY, CAVD mortality, and the modifiable risk factors in the last 30 years, across 204 countries and territories, and their relationship with the period, age, and birth cohort. Methods: Data were obtained from the Global Burden of Disease (GBD) 2019 database. An age-period-cohort (APC) model was used to assess general annual percentage changes in DALYs and mortality over the past 30 years in 204 countries and territories. Results: In 2019, the age-standardized mortality rate for the entire population in areas with a high socio-demographic index (SDI) was more than 4 times higher than that in low-SDI areas. From 1990 to 2019, the net drift in mortality for the whole population was from -2.1% [95% confidence interval (CI): -2.39% to -1.82%] per year in high-SDI regions to 0.05% (95% CI: -0.13% to 0.23%) per year in low- to medium-SDI regions. The trend of DALYs was similar to that of mortality. The age-wise distribution of deaths exhibited a shift toward older populations in high-SDI regions globally, except for Qatar, Saudi Arabia, and the United Arab Emirates. Over time, in most medium, medium-low, and low SDI regions, there was no significant improvement in the period and birth cohort or even an unfavorable or worsening risk. The main variable risk factors of CAVD death and DALYs lost were high sodium diet, high systolic blood pressure, and lead exposure. Those risk factors only showed a significant downward trend in middle- and high-SDI regions. Conclusions: Health disparities between regions for CAVD are widening and could lead to a heavy disease burden in the future. Health authorities and policymakers in low SDI areas, in particular, need to consider improving resource allocation, increasing access to medical resources, and controlling variable risk factors to stem the growth of the disease burden.

17.
iScience ; 26(11): 108150, 2023 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-37908310

RESUMEN

Recent studies suggest that pleiotropic effects may explain the genetic architecture of cardiovascular diseases (CVDs). We conducted a comprehensive gene-centric pleiotropic association analysis for ten CVDs using genome-wide association study (GWAS) summary statistics to identify pleiotropic genes and pathways that may underlie multiple CVDs. We found shared genetic mechanisms underlying the pathophysiology of CVDs, with over two-thirds of the diseases exhibiting common genes and single-nucleotide polymorphisms (SNPs). Significant positive genetic correlations were observed in more than half of paired CVDs. Additionally, we investigated the pleiotropic genes shared between different CVDs, as well as their functional pathways and distribution in different tissues. Moreover, six hub genes, including ALDH2, XPO1, HSPA1L, ESR2, WDR12, and RAB1A, as well as 26 targeted potential drugs, were identified. Our study provides further evidence for the pleiotropic effects of genetic variants on CVDs and highlights the importance of considering pleiotropy in genetic association studies.

18.
Artículo en Inglés | MEDLINE | ID: mdl-37852669

RESUMEN

AIM: To increase the comprehensive understanding of trends in the burden of cardiovascular disease (CVD) attributable to low physical activity in the Western Pacific Region. METHODS: Based on data from the Global Burden of Disease (GBD) study for the years 1990-2019, an age-period-cohort (APC) analysis was conducted to investigate trends in CVD-related mortality attributable to low physical activity in the Western Pacific Region and associations with age, period, and birth cohort. We also used joinpoint regression analysis to identify the periods with the most substantial changes. RESULTS: The Western Pacific Region witnessed a substantial increase in CVD deaths attributable to low physical activity, accompanied by a rise in all-age CVD-related mortality. However, the age-standardized death rate was lower in the region than the global level, highlighting the importance of considering the age composition of CVD burden in the region. Countries with higher SDI levels exhibited lower mortality than those with lower SDI levels. The longitudinal analysis using the APC model indicated an overall improvement in CVD-related mortality attributable to low physical activity in the region, but with differences between sexes and CVD subtypes. Specific period in which CVD-related mortality decreased significantly were 2011-2016, for the average annual percentage change for the period was -0.69%. CONCLUSION: The study highlights the significance of addressing low physical activity as a modifiable risk factor for CVD burden in the Western Pacific Region. Further research is essential to understand the factors contributing to inter-country variations, sex disparities, and CVD subtypes distinctions.

19.
Quant Imaging Med Surg ; 13(12): 8657-8668, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38106309

RESUMEN

Background: As the global burden of hypertension continues to increase, early diagnosis and treatment play an increasingly important role in improving the prognosis of patients. In this study, we developed and evaluated a method for predicting abnormally high blood pressure (HBP) from infrared (upper body) remote thermograms using a deep learning (DL) model. Methods: The data used in this cross-sectional study were drawn from a coronavirus disease 2019 (COVID-19) pilot cohort study comprising data from 252 volunteers recruited from 22 July to 4 September 2020. Original video files were cropped at 5 frame intervals to 3,800 frames per slice. Blood pressure (BP) information was measured using a Welch Allyn 71WT monitor prior to infrared imaging, and an abnormal increase in BP was defined as a systolic blood pressure (SBP) ≥140 mmHg and/or diastolic blood pressure (DBP) ≥90 mmHg. The PanycNet DL model was developed using a deep neural network to predict abnormal BP based on infrared thermograms. Results: A total of 252 participants were included, of which 62.70% were male and 37.30% were female. The rate of abnormally high HBP was 29.20% of the total number. In the validation group (upper body), precision, recall, and area under the receiver operating characteristic curve (AUC) values were 0.930, 0.930, and 0.983 [95% confidence interval (CI): 0.904-1.000], respectively, and the head showed the strongest predictive ability with an AUC of 0.868 (95% CI: 0.603-0.994). Conclusions: This is the first technique that can perform screening for hypertension without contact using existing equipment and data. It is anticipated that this technique will be suitable for mass screening of the population for abnormal BP in public places and home BP monitoring.

20.
Bioact Mater ; 24: 252-262, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36632501

RESUMEN

Ventricular septal defect (VSD) is one of the commonest congenital heart diseases (CHDs). Current occluders for VSD treatment are mainly made of nitinol, which has the risk of nickel allergy, persistent myocardial abrasion and fatal arrythmia. Herein, a fully biodegradable polydioxanone (PDO) occluder equipped with a shape line and poly-l-lactic acid PLLA membranes is developed for VSD closure without the addition of metal marker. PDO occluder showed great mechanical strength, fatigue resistance, geometry fitness, biocompatibility and degradability. In a rat subcutaneous implantation model, PDO filaments significantly alleviated inflammation response, mitigated fibrosis and promoted endothelialization compared with nitinol. The safety and efficacy of PDO occluder were confirmed in a canine VSD model with 3-year follow-up, demonstrating the biodegradable PDO occluder could not only effectively repair VSD, induce cardiac remodeling but also address the complications associated with metal occluders. Furthermore, a pilot clinical trial with five VSD patients indicated that all the occluders were successfully implanted under the guidance of echocardiography and no adverse events occurred during the 3-month follow-up. Collectively, the fully bioresorbable PDO occluder is safe and effective for clinical VSD closure and holds great promise for the treatment of structural CHDs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA