1.
J Obstet Gynaecol Res ; 48(5): 1157-1164, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35178830

RESUMEN

AIM: To assess the impact of laser power and time on interstitial ablation generated by neodymium-doped yttrium aluminium garnet (Nd:YAG) and diode laser in the human placental model. METHODS: The experiment was carried out in a simulation model of interstitial laser ablation on ex-vivo placental tissue. One-hundred and forty-four pieces of fresh placentae were interstitially ablated with Nd:YAG or diode laser at various power (15, 20, 25, 30 W)-time (5, 10, 15 s) combinations. The ablation tissues were evaluated using both sonographic and histopathologic measurements. RESULTS: Laser generator, power, and time significantly affected the ablation size (p < 0.001). The coagulation zone continuously increased with extending time at the power of 15, 20, and 25 W. When adjusting to the power of 30 W, increased time from 10 to 15 s did not induce the larger coagulation diameter. The maximal diameter was obtained at the laser power of 20 W for 15 s. The ablation from the diode laser was greater than that from Nd:YAG laser. The sonographic evaluation overestimated the ablation size by an average of 24%. CONCLUSION: Diode laser destroys greater tissue than Nd:YAG laser. Different power settings of interstitial laser ablation produce diverse patterns of correlation between laser time and coagulation size.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Femenino , Humanos , Láseres de Estado Sólido/uso terapéutico , Placenta/diagnóstico por imagen , Placenta/cirugía , Embarazo
2.
BMC Pregnancy Childbirth ; 21(1): 797, 2021 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-34847869

RESUMEN

BACKGROUND: Placental anastomoses in monochorionic diamniotic (MCDA) twin pregnancy have a major impact on fetal circulation. This study was designed to define reference ranges of cardiac and vascular Doppler indices in MCDA twin pregnancies. METHODS: This cross-sectional study included 442 uncomplicated MCDA twin fetuses undergoing Doppler ultrasonography at 18-35 weeks of gestation. Left and right myocardial performance index (LV-MPI, RV-MPI), E/A ratio of atrioventricular valves, pulsatility indices of umbilical artery, middle cerebral artery (MCA), and ductus venosus (DV), cerebroplacental ratio, peak systolic velocity of MCA, S/a ratio of DV, and early diastolic filling time of ductus venosus (DV-E) were evaluated under standardized settings. The equation models between Doppler indices and gestational age (GA) were fitted. After adjustment for GA, the correlations between MPI and fetal heart rate (FHR), and between MPI and DV indices were analyzed. RESULTS: Estimated centiles of Doppler indices were derived as a function of GA, being distinct in values from those of singletons. There was no correlation between GA-adjusted MPI and FHR. DV-E was inversely related to LV-MPI. CONCLUSIONS: MCDA twins showed significant changes in some Doppler indices throughout gestation with quantitative differences from singletons, emphasizing the importance of MC twin-specific reference values for clinical application. Further adjustment of MPI for FHR was unnecessary. DV-E is a vascular index indirectly representing fetal diastolic function.


Asunto(s)
Fenómenos Fisiológicos Cardiovasculares , Edad Gestacional , Embarazo Gemelar/fisiología , Ultrasonografía Doppler , Ultrasonografía Prenatal , Adulto , Estudios de Cohortes , Estudios Transversales , Femenino , Humanos , Embarazo , Estudios Prospectivos , Valores de Referencia
3.
J Perinat Med ; 2021 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-33818041

RESUMEN

Skin-over-biocellulose for Antenatal Fetoscopic Repair (SAFER) is a recently developed technique for fully percutaneous fetoscopic repair of myelomeningocele. The formation of a neo-dura mater triggered by the use of a biocellulose patch over the placode obviates the need of primary repair of fetal dura mater, and seems to further improve neurodevelopmental outcome. Insufflation of humidified carbon dioxide into the amniotic cavity requires proper training and a different equipment set from those used in the classic "under-water" fetoscopy. To shorten the learning curve of novice teams, we have developed a structured training course encompassing three critical steps: (1) visiting the proctor center, (2) selection of the first case, and (3) on-site training of the surgical team. Upon the site arrival, there will be: (1) theoretical lecture for all specialists involved in the fetal care, (2) simulation training, and (3) surgical proctoring. Proctor team can take over the surgery if the local team cannot complete. This training course has been successfully used in five different countries: Israel, Chile, Italy, USA and England and all local teams are already performing surgeries solo without any failures or maternal morbidity. Teaching new procedures in fetal medicine is challenging, because of the small number of candidate cases, and the direct relation of good outcomes and the number of cases operated. This proposed training modules may be adopted by other teams that want to embark on this type of novel minimally invasive treatment.

4.
Prenat Diagn ; 40(8): 958-965, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32297344

RESUMEN

BACKGROUND: Twin reversed arterial perfusion (TRAP) sequence consists of acardiac twin (A) paradoxically perfused by pump twin (P) through an umbilical artery (UA). We proposed characterization of acardiac twins with intrafetal vascular pattern (IVP), and assessed its correlation with morphology and UA Doppler indices. METHODS: We prospectively evaluated 21 cases of TRAP sequence. Morphology (acardia vs hemicardia) and IVP (simple vs complex) of acardiac twins were characterized with ultrasound and color Doppler. Twins weight ratio (A/P Wt) and UA Doppler indices of acardiac and pump twins including (1) difference of systolic/diastolic ratio (UA ∆S/D), (2) difference of resistance index (UA ∆RI), and (3) ratio of pulsatility index (UA PI A/P) were calculated. RESULTS: The median (min, max) gestational age at diagnosis was 18 (11, 27) weeks. Acardia (n = 14) were associated with simple IVP (n = 16) (P < .05). After exclusion of acardia with complex IVP (n = 1), the A/P Wt, UA ∆S/D, UA ∆RI, and UA PI A/P of acardia with simple IVP (n = 13), hemicardia with simple IVP (n = 3), and hemicardia with complex IVP (n = 4) were not significantly different (P > .05). CONCLUSIONS: Most of acardiac twins were acardia with simple IVP. Morphology and IVP of acardiac twins were not associated with UA Doppler indices.


Asunto(s)
Transfusión Feto-Fetal/diagnóstico , Cardiopatías Congénitas/diagnóstico , Ultrasonografía Doppler , Arterias Umbilicales/diagnóstico por imagen , Adulto , Femenino , Transfusión Feto-Fetal/epidemiología , Transfusión Feto-Fetal/patología , Feto/anomalías , Feto/irrigación sanguínea , Feto/diagnóstico por imagen , Edad Gestacional , Cardiopatías Congénitas/epidemiología , Cardiopatías Congénitas/patología , Humanos , Masculino , Embarazo , Tailandia/epidemiología , Gemelos Monocigóticos , Ultrasonografía Prenatal , Arterias Umbilicales/patología , Arterias Umbilicales/fisiopatología
5.
J Perinat Med ; 48(9): 931-942, 2020 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-32681782

RESUMEN

Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)-associated infection (COVID-19) is affecting populations worldwide. This statement may serve as guidance for infection prevention and safe ultrasound practices during the COVID-19 pandemic. Ultrasound examination is a fundamental part of obstetric care, yet it is a potential vector for transmission of SARS-CoV-2. Decontamination methods should always be implemented for ultrasound equipment, especially in the presence of suspected or confirmed COVID-19 cases. There must be workflow policies to protect pregnant women and healthcare providers from nosocomial cross transmission of SARS-CoV-2. Cleaning and disinfecting of equipment must be in accordance with their potential of pathogen transmission. Consider using telemedicine and genetic technologies as an adjunctive of obstetric ultrasound to reduce patient crowding. Patient triage and education of healthcare providers of infection prevention are crucial to minimize cross contamination of SARS-CoV-2 during obstetric ultrasound.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/transmisión , Transmisión de Enfermedad Infecciosa/prevención & control , Contaminación de Equipos/prevención & control , Neumonía Viral/transmisión , Complicaciones Infecciosas del Embarazo/virología , Ultrasonografía Prenatal/instrumentación , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/prevención & control , Desinfección/métodos , Femenino , Personal de Salud/educación , Humanos , Higiene , Pandemias/prevención & control , Neumonía Viral/diagnóstico , Neumonía Viral/prevención & control , Embarazo , Complicaciones Infecciosas del Embarazo/diagnóstico , Complicaciones Infecciosas del Embarazo/prevención & control , SARS-CoV-2
6.
J Perinat Med ; 48(2): 102-114, 2020 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-31961794

RESUMEN

Three-dimensional ultrasound (3DUS) may provide additional information for prenatal assessment of twins. It may improve the diagnostic confidence of dating, nuchal translucency (NT) and chorionicity assignment in twin pregnancies. The "virtual 3DUS placentoscopy" can guide selective fetoscopic laser photocoagulation (SFLP) to treat twin-twin transfusion syndrome (TTTS). Volumetric assessment of the dysmorphic acardiac twin with the Virtual Organ Computer-aided Analysis (VOCAL) software is more accurate than the conventional ultrasound measurement. Twin anemia polycythemia (TAP) sequence and selective intrauterine growth restriction (sIUGR) may be clinically monitored with 3DUS placental volume (PV) and power Doppler vascular indices. Congenital anomalies are more common in twins. Evaluation of fetal anomalies with 3DUS could assist perinatal management. The 3DUS power Doppler can provide a better understanding of true and false umbilical cord knots, which are commonly found in monoamniotic (MA) twins. Single demise in monochorionic (MC) twin pregnancies can cause severe neurologic morbidity in the surviving co-twin. Prenatal prediction of brain injury in the surviving co-twin with unremarkable neurosonographic examination is difficult. The 3DUS power Doppler may aid in prenatal detection of subtle abnormal cerebral perfusion. Prenatal assessment of conjoined twins with 3DUS is important if emergency postnatal surgical separation is anticipated. There is no significant additional advantage in using real-time 3DUS to guide prenatal interventions. Assessment of the cervix and pelvic floor during twin pregnancies is enhanced with 3DUS. Due to lack of high-quality studies, routine prenatal 3DUS in twin pregnancies needs to be balanced with risks of excessive ultrasound exposure.


Asunto(s)
Imagenología Tridimensional , Embarazo Gemelar , Ultrasonografía Prenatal , Parálisis Cerebral/diagnóstico por imagen , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Transfusión Feto-Fetal/diagnóstico por imagen , Humanos , Embarazo
7.
Fetal Diagn Ther ; 47(1): 84-90, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31461709

RESUMEN

BACKGROUND: A low-fidelity fetoscopic surgical simulator (FSS) for training of selective fetoscopic laser photocoagulation (SFLP) was developed. OBJECTIVE: To evaluate and compare training satisfaction with an FSS and with a conventional box trainer (BT). METHODS: The BT consisted of a cleaned human placenta attached to the inside of a plastic storage box with a watertight lock cover and an ultrasound-transparent rubber skin. The FSS consisted of the replica of a monochorionic twin placenta attached to the inside of a spherically shaped, ultrasound-transparent phantom. Tap water was used as an ultrasound conduction agent. Evaluation of the mannequin trainings was conducted on 8 junior maternal-fetal medicine (MFM) attending physicians and 22 MFM fellows. Training satisfaction was scored from 0 to 10 on 8 different domains. RESULTS: The mean satisfaction score (±SD) with the FSS was higher than with the BT in all domains (p < 0.05). The fellows' training satisfaction with the BT was greater than that of the attending physicians in 4 domains: tactile feedback, demonstration of chorionic vessels, feedback on performance, and overall value as learning aid (p < 0.05). CONCLUSIONS: As evaluated by a small group of trainees, our FSS is superior to the BT in mannequin training of SFLP. However, the BT may be more useful for trainees with limited clinical experience.


Asunto(s)
Fetoscopía/educación , Coagulación con Láser/educación , Maniquíes , Entrenamiento Simulado , Femenino , Humanos , Embarazo
8.
Am J Obstet Gynecol ; 221(6): 650.e1-650.e16, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31589866

RESUMEN

BACKGROUND: The administration of aspirin <16 weeks gestation to women who are at high risk for preeclampsia has been shown to reduce the rate of preterm preeclampsia by 65%. The traditional approach to identify such women who are at risk is based on risk factors from maternal characteristics, obstetrics, and medical history as recommended by the American College of Obstetricians and Gynecologists and the National Institute for Health and Care Excellence. An alternative approach to screening for preeclampsia has been developed by the Fetal Medicine Foundation. This approach allows the estimation of patient-specific risks of preeclampsia that requires delivery before a specified gestational age with the use of Bayes theorem-based model. OBJECTIVE: The purpose of this study was to examine the diagnostic accuracy of the Fetal Medicine Foundation Bayes theorem-based model, the American College of Obstetricians and Gynecologists, and the National Institute for Health and Care Excellence recommendations for the prediction of preterm preeclampsia at 11-13+6 weeks gestation in a large Asian population STUDY DESIGN: This was a prospective, nonintervention, multicenter study in 10,935 singleton pregnancies at 11-13+6 weeks gestation in 11 recruiting centers across 7 regions in Asia between December 2016 and June 2018. Maternal characteristics and medical, obstetric, and drug history were recorded. Mean arterial pressure and uterine artery pulsatility indices were measured according to standardized protocols. Maternal serum placental growth factor concentrations were measured by automated analyzers. The measured values of mean arterial pressure, uterine artery pulsatility index, and placental growth factor were converted into multiples of the median. The Fetal Medicine Foundation Bayes theorem-based model was used for the calculation of patient-specific risk of preeclampsia at <37 weeks gestation (preterm preeclampsia) and at any gestation (all preeclampsia) in each participant. The performance of screening for preterm preeclampsia and all preeclampsia by a combination of maternal factors, mean arterial pressure, uterine artery pulsatility index, and placental growth factor (triple test) was evaluated with the adjustment of aspirin use. We examined the predictive performance of the model by the use of receiver operating characteristic curve and calibration by measurements of calibration slope and calibration in the large. The detection rate of screening by the Fetal Medicine Foundation Bayes theorem-based model was compared with the model that was derived from the application of American College of Obstetricians and Gynecologists and National Institute for Health and Care Excellence recommendations. RESULTS: There were 224 women (2.05%) who experienced preeclampsia, which included 73 cases (0.67%) of preterm preeclampsia. In pregnancies with preterm preeclampsia, the mean multiples of the median values of mean arterial pressure and uterine artery pulsatility index were significantly higher (mean arterial pressure, 1.099 vs 1.008 [P<.001]; uterine artery pulsatility index, 1.188 vs 1.063[P=.006]), and the mean placental growth factor multiples of the median was significantly lower (0.760 vs 1.100 [P<.001]) than in women without preeclampsia. The Fetal Medicine Foundation triple test achieved detection rates of 48.2%, 64.0%, 71.8%, and 75.8% at 5%, 10%, 15%, and 20% fixed false-positive rates, respectively, for the prediction of preterm preeclampsia. These were comparable with those of previously published data from the Fetal Medicine Foundation study. Screening that used the American College of Obstetricians and Gynecologists recommendations achieved detection rate of 54.6% at 20.4% false-positive rate. The detection rate with the use of National Institute for Health and Care Excellence guideline was 26.3% at 5.5% false-positive rate. CONCLUSION: Based on a large number of women, this study has demonstrated that the Fetal Medicine Foundation Bayes theorem-based model is effective in the prediction of preterm preeclampsia in an Asian population and that this method of screening is superior to the approach recommended by American College of Obstetricians and Gynecologists and the National Institute for Health and Care Excellence. We have also shown that the Fetal Medicine Foundation prediction model can be implemented as part of routine prenatal care through the use of the existing infrastructure of routine prenatal care.


Asunto(s)
Presión Arterial/fisiología , Factor de Crecimiento Placentario/sangre , Preeclampsia/epidemiología , Flujo Pulsátil , Arteria Uterina/diagnóstico por imagen , Adulto , Pueblo Asiatico , Aspirina/uso terapéutico , Teorema de Bayes , Femenino , Edad Gestacional , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Preeclampsia/diagnóstico , Preeclampsia/prevención & control , Embarazo , Primer Trimestre del Embarazo , Diagnóstico Prenatal , Estudios Prospectivos , Medición de Riesgo/métodos
9.
Prenat Diagn ; 39(13): 1291-1297, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31671220

RESUMEN

OBJECTIVES: To develop a simulation model and assess the learning curve of fetal shunting. METHODS: Three staff and three trainees performed fetal shunting on a model using the fetal bladder stent. The model was evaluated according to various sources of validity evidence. The number of procedures to reach competency was determined by the learning curve-cumulative summation (LC-CUSUM) and CUSUM analysis. The learning and control phases were defined as the periods before and after passing the level of competency, respectively. RESULTS: The model was validated to be constructive in the educational process. A total of 600 procedures were carried out with an overall success rate of 94.2% and no significant difference between staff and trainees. The average number of procedures to reach competency was 47. Total procedural time decreased after passing the level of competency. Although the trainees required a longer procedural time in the learning phase than the staff did, there was no significant between-group difference in the control phase. CONCLUSIONS: Using this model, the estimated number of procedures to achieve competency was 47, as substantiated by the increased procedural success and reduced procedural time in the control phase. Training on this simulation model may improve technical performance.


Asunto(s)
Terapias Fetales , Entrenamiento Simulado/métodos , Adulto , Femenino , Humanos , Curva de Aprendizaje , Stents
10.
J Perinat Med ; 47(6): 643-650, 2019 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-31265430

RESUMEN

Objective To derive and validate a population-specific multivariate approach for birth weight (BW) prediction based on quantitative intrapartum assessment of maternal characteristics by means of an algorithmic method in low-risk women. Methods The derivation part (n = 200) prospectively explored 10 variables to create the best-fit algorithms (70% correct estimates within ±10% of actual BW) for prediction of BW at term; vertex presentation with engagement. The algorithm was then cross validated with samples of unrelated cases (n = 280) to compare the accuracy with the routine abdominal palpation method. Results The best-fit algorithms were parity-specific. The derived simplified algorithms were (1) BW (g) = 100 [(0.42 × symphysis-fundal height (SFH; cm)) + gestational age at delivery (GA; weeks) - 25] in nulliparous, and (2) BW (g) = 100 [(0.42 × SFH (cm)) + GA - 23] in multiparous. Cross validation showed an overall 69.3% accuracy within ±10% of actual BW, which exceeded routine abdominal palpation (60.4%) (P = 0.019). The algorithmic BW prediction was significantly more accurate than routine abdominal palpation in women with the following characteristics: BW 2500-4000 g, multiparous, pre-pregnancy weight <50 kg, current weight <60 kg, height <155 cm, body mass index (BMI) <18.5 kg/m2, cervical dilatation 3-5 cm, station <0, intact membranes, SFH 30-39 cm, maternal abdominal circumference (mAC) <90 cm, mid-upper arm circumference (MUAC) <25 cm and female gender of the neonates (P < 0.05). Conclusion An overall accuracy of term BW prediction by our simplified algorithms exceeded that of routine abdominal palpation.


Asunto(s)
Algoritmos , Peso al Nacer , Pesos y Medidas Corporales/métodos , Diagnóstico Prenatal/métodos , Ultrasonografía Prenatal/métodos , Adulto , Índice de Masa Corporal , Precisión de la Medición Dimensional , Femenino , Edad Gestacional , Humanos , Recién Nacido , Paridad , Valor Predictivo de las Pruebas , Embarazo , Pronóstico , Reproducibilidad de los Resultados , Tailandia
11.
Prenat Diagn ; 38(7): 504-510, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29722035

RESUMEN

OBJECTIVE: The objective of the study is to compare radiofrequency (RF) effects on fresh placentae with varying levels of sustained time (Ts) and degrees of target temperature (°t). METHOD: A total of 108 pieces of fresh placentae were coagulated with a 2-cm RF needle at 60 W in an organ bath. The vertical and horizontal diameters (Vd, Hd) of tissue coagulation visualized by ultrasound were measured. The impacts of 12 different Ts-°t combinations on the ablation size ascertained on pathological examination (Vdp , Hdp ) were compared using 2-way ANOVA. The agreement between sonographic and pathological findings was assessed using Bland-Altman analysis. RESULTS: Considerable changes in the Vdp and Hdp were associated with increasing the Ts and °t. The impact of RF on tissue coagulation was greatest when the °t was set at 100°C, with further destruction as the Ts progressed to 7 minutes of exposure. The ablation size estimated by ultrasound exhibited an overestimation by an average of 5.65% and 21.02% for Vd and Hd, respectively. CONCLUSION: A prolonged Ts at a higher °t contributes to progressive placental tissue destruction by RF, with maximum destruction at 100°C for 7 minutes in an ex vivo nonperfused placenta. Tissue injury that is apparent on ultrasound may extend beyond pathological damage.


Asunto(s)
Placenta/efectos de la radiación , Ablación por Radiofrecuencia , Femenino , Calor , Humanos , Técnicas In Vitro , Embarazo , Factores de Tiempo
12.
J Obstet Gynaecol Res ; 44(5): 813-830, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29442407

RESUMEN

The benefit of the early administration of aspirin to reduce preterm pre-eclampsia among screened positive European women from multivariate algorithmic approach (ASPRE trial) has opened an intense debate on the feasibility of universal screening. This review aims to assess the new perspectives in the combined screening of pre-eclampsia in the first trimester of pregnancy and the chances for prevention using low-dose aspirin with special emphasis on the particularities of the Asian population. PubMed, CENTRAL and Embase databases were searched from inception until 15 November 2017 using combinations of the search terms: preeclampsia, Asian, prenatal screening, early prediction, ultrasonography, pregnancy, biomarker, mean arterial pressure, soluble fms-like tyrosine kinase-1, placental growth factor, pregnancy-associated plasma protein-A and pulsatility index. This is not a systematic review or meta-analysis, so the risk of bias of the selected published articles and heterogeneity among the studies need to be considered. The prevalence of pre-eclampsia and serum levels of biochemical markers in Asian are different from Caucasian women; hence, Asian ethnicity needs to be corrected for in the algorithmic assessment of multiple variables to improve the screening performance. Aspirin prophylaxis may still be viable in Asian women, but resource implication needs to be considered. Asian ethnicity should be taken into account before implementing pre-eclampsia screening strategies in the region. The variables included can be mixed and matched to achieve an optimal performance that is appropriate for economical restriction in individual countries.


Asunto(s)
Pueblo Asiatico , Preeclampsia , Pueblo Asiatico/etnología , Femenino , Humanos , Preeclampsia/diagnóstico , Preeclampsia/etnología , Preeclampsia/prevención & control , Embarazo
13.
J Perinat Med ; 45(3): 273-279, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-27071145

RESUMEN

An estimated 276,000 babies die within 4 weeks of birth every year, worldwide, from congenital anomalies. Better quality ultrasound screening can increase the detection of these fetal malformations in the prenatal period. Prenatal counseling for the pregnant woman and her family, regarding the nature of the disease and prognosis is necessary. Options for management in prenatal, perinatal, intrapartum, neonatal, and childhood periods need to be thoroughly discussed, so that the family can make an informed decision. A multidisciplinary approach is usually needed once a decision has been made to optimize fetal outcome, to plan for the timing and location as well as the mode of delivery. In most of the cases, vaginal delivery can be attempted. An elective cesarean delivery should be reserved for maternal concern of dystocia, certain fetal conditions that cesarean delivery will optimize perinatal outcome, or if the parents have a psychosocial determination to have a live-born infant.


Asunto(s)
Anomalías Congénitas/terapia , Parto Obstétrico/métodos , Cesárea , Anomalías Congénitas/diagnóstico , Consejo , Femenino , Humanos , Recién Nacido , Embarazo , Diagnóstico Prenatal
14.
J Perinat Med ; 45(6): 667-691, 2017 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-28231064

RESUMEN

Conjoined twins are a rare, but serious, complication of monozygotic twins. Early prenatal diagnosis of conjoined twins is increasingly made with transvaginal ultrasound and color Doppler studies. Most prenatally diagnosed conjoined twins are terminated due to the high perinatal mortality, but advancement in pediatric surgery has allowed for successful postnatal separation in a small number of cases, and some parents may consider this option over termination of pregnancy. It is important to get a detailed prenatal ultrasound for the site and extent of fusion for an accurate categorization. Three-dimensional ultrasound (3DUS) provides images that can facilitate counselling for the parents. Additional information that impacts on diagnosis, prognostication, and perinatal management of conjoined twins could be obtained from selective use of 3DUS, particularly those with atypical fetal union. Most of the proposed additional benefits of 3DUS are based on case reports. Magnetic resonance imaging (MRI) has been increasingly used for the purpose of identifying intricate organ sharing. Because of the rarity of this condition, and the heterogeneity of fetal fusion, added benefits of either 3DUS or MRI for prenatal diagnosis and perinatal management of conjoined twins have not been demonstrated by well-conducted clinical trials. This article aims to review clinical application of various 3DUS display modes in prenatal assessment of conjoined twins, focusing on their potential additional benefits, risks and misuses. 3DUS may help detecting additional findings that are not possible with 2DUS, but, it has not been scientifically shown to improve the survival rate of the twins or reduce maternal morbidity.


Asunto(s)
Gemelos Siameses , Ultrasonografía Prenatal , Femenino , Humanos , Imagenología Tridimensional , Embarazo
15.
J Perinat Med ; 45(7): 895-901, 2017 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-28665791

RESUMEN

INTRODUCTION: Circulating soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PlGF) are potential markers for preeclampsia. The objective was to construct and analyse the reference ranges of serum levels of sFlt-1 and PlGF throughout the course of pregnancy in low-risk Thai pregnant women. METHODS: We enrolled 110 low-risk, Thai women singleton pregnancy from 10 to 40 gestational weeks. Serum concentrations of sFlt-1 and PlGF were measured with an automated assay. The reference ranges of serum levels of sFlt-1, PlGF and sFlt-1/PlGF ratio were constructed and assessed for possible correlations with gestational age, maternal factors [age, parity, tobacco use, artificial reproductive technologies (ARTS) and body mass index (BMI)], and pregnancy outcomes (gestational age at delivery, development of preeclampsia, neonatal birth weight and placental weight). RESULTS: None of the subjects developed preeclampsia. Serum sFlt-1 concentrations significantly elevated from 20 to 40 gestational weeks (P=0.003). Significant elevation and dropping of serum PlGF levels and sFlt-1/PlGF ratios were observed at 10 to 29 and 30 to 40 weeks of gestation, respectively (P<0.001). There was an inversed correlation between serum PlGF levels at 20 to 29 gestational weeks and neonatal birth weights (r=-0.48, P<0.05). There were no associations between serum levels of sFlt-1, PlGF, or sFlt-1/PlGF ratios and maternal BMI, gestational age at delivery, or placental weight (P>0.05). Effects from parity, smoking and ARTS were inconclusive. CONCLUSION: Robust change of serum PlGF levels suggests for its broader clinical application compared to sFlt-1. Prediction of preeclampsia using serum analytes may be gestational period specific.


Asunto(s)
Factor de Crecimiento Placentario/sangre , Embarazo/sangre , Receptor 1 de Factores de Crecimiento Endotelial Vascular/sangre , Adulto , Estudios Transversales , Femenino , Humanos , Valores de Referencia , Adulto Joven
16.
Fetal Diagn Ther ; 41(3): 161-178, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28219061

RESUMEN

OBJECTIVES: The Management of Myelomeningocele Study (MOMS Trial) has inspired many fetal therapy centers (FTCs) to offer open fetal surgery for myelomeningocele (MMC). This is an initial effort to create a candidate model that can be applicable to many parts of Asia. MATERIAL AND METHODS: A limited selection of specialists from 4 established FTCs in Thailand, Hong Kong, India, and Singapore met for a round table discussion. Experts from Children's Hospital of Philadelphia (CHOP) involved in the Trial moderated the session. The practice suggestions in this statement were from a targeted literature review and expert opinion. RESULTS: A high prevalence of MMC in Asia supports an effort to adopt the procedure, but only in established FTCs with good maternal and neonatal ancillary supports. The falling incidence of MMCs may affect case volume and maintenance of skill. A regional approach was recommended. Fetal benefits have to be weighed against maternal risks, with a consideration of recent outcome data from the endoscopic approach. Responsible FTCs need standardized diagnosis and management, with their long-term outcome data available for an audit. CONCLUSIONS: It is envisaged that the information presented by this multidisciplinary team would be useful for FTCs in Asia or elsewhere that plan to establish more advanced fetal care in the future.


Asunto(s)
Fetoscopía/normas , Meningomielocele/epidemiología , Meningomielocele/cirugía , Asia/epidemiología , Femenino , Fetoscopía/métodos , Humanos , Meningomielocele/diagnóstico , Embarazo , Atención Prenatal/métodos , Atención Prenatal/normas , Singapur/epidemiología
18.
J Perinat Med ; 44(2): 131-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26506099

RESUMEN

Mid trimester fetal anatomy scan is a fundamental part of routine antenatal care. Some U/S soft markers or controversial U/S signs are seen during the scan and create some confusion regarding their relation to fetal chromosomal abnormalities. Example of these signs: echogenic focus in the heart, echogenic bowel, renal pyelectasis, ventriculomegaly, polydactely, club foot, choroid plexus cyst, single umbilical artery. We are presenting an evidence based approach from the literature for management of these controversial U/S signs.


Asunto(s)
Ultrasonografía Prenatal , Encefalopatías/congénito , Encefalopatías/diagnóstico por imagen , Cardiomegalia/congénito , Cardiomegalia/diagnóstico por imagen , Plexo Coroideo/diagnóstico por imagen , Pie Equinovaro/diagnóstico por imagen , Anomalías Congénitas/diagnóstico por imagen , Quistes/congénito , Quistes/diagnóstico por imagen , Ecocardiografía , Intestino Ecogénico/diagnóstico por imagen , Medicina Basada en la Evidencia , Femenino , Humanos , Recién Nacido , Masculino , Polidactilia/diagnóstico por imagen , Embarazo , Segundo Trimestre del Embarazo , Pielectasia/diagnóstico por imagen , Arteria Umbilical Única/diagnóstico por imagen
19.
J Perinat Med ; 44(2): 119-23, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26389632

RESUMEN

Today we are living in a globalized world in which information on what is happening in one part of the world is easily communicated to other parts of the world. This happens thanks to advancement in science and technology. One area where technology has made the greatest impact is heath care provision. Ultrasound technology is now playing a critical role in health care provision particularly in Obstetrics and Gynaecology. This has significantly assisted in provision of quality health care to pregnant women and their unborn infants and in reducing maternal and neonatal morbidity and mortality in the developed world. Africa the continent with greatest health care challenges and with the highest maternal and neonatal mortalities is yet to fully utilize this important technology. The need for this technology is great as the conditions requiring its application abound. The effective application of Ultrasound however faces serious challenges in Africa. To successfully entrench Ultrasound in quality Obstetrics and Gynaecology care various approaches must be adopted to overcome the challenges. The aim of this paper is to identify the benefits and the challenges inimical to the application Ultrasound in Obstetrics and Gynecology in Africa. It also examines what needs to be done to achieve better application of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Ultrasonografía Prenatal/estadística & datos numéricos , África , Países en Desarrollo , Femenino , Ginecología/tendencias , Humanos , Recién Nacido , Obstetricia/tendencias , Perinatología/tendencias , Embarazo , Calidad de la Atención de Salud/tendencias , Ultrasonografía Prenatal/tendencias
20.
J Perinat Med ; 44(2): 125-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26376219

RESUMEN

Gray-scale image data are processed in 3D ultrasound by repeated scans of multiple planes within a few seconds to achieve one surface rendering image and three perpendicular plane images. The 4D image is achieved by repeating 3D images in short intervals, i.e. 3D and 4D ultrasound are based on simple B-mode images. During 3D/4D acquisition, a fetus in utero is exposed by ultrasound beam for only a few seconds, and it is as short as real-time B-mode scanning. Therefore, simple 3D imaging is as safe as a simple B-mode scan. The 4D ultrasound is also as safe as a simple B-mode scan, but the ultrasound exposure should be shorter than 30 min. The thermal index (TI) and mechanical index (MI) should both be lower than 1.0, and the ultrasound study is regulated by the Doppler ultrasound if it is combined with simple 3D or 4D ultrasound. Recently, some articles have reported the functional changes of animal fetal brain neuronal cells and liver cell apoptosis with Doppler ultrasound. We discuss cell apoptosis by ultrasound in this report. Diagnostic ultrasound safety is achieved by controlling the output pulse and continuous ultrasound waves using thermal and mechanical indices, which should be <1.0 in abdominal and transvaginal scan, pulsed Doppler, as well as 3D and 4D ultrasound. The lowest spatial peak temporal average (SPTA) intensity of the ultrasound to suppress cultured cell growth is 240 mW/cm2, below which no ultrasound effect has been reported. An ultrasound user must be trained to recognize the ultrasound bioeffects; thermal and mechanical indices, and how to reduce these when they are higher than 1.0 on the monitor display; and guide the proper use of the ultrasound under the ALARA principle, because the user is responsible for ensuring ultrasound safety.


Asunto(s)
Imagenología Tridimensional/métodos , Ultrasonografía Prenatal/métodos , Animales , Femenino , Feto/diagnóstico por imagen , Humanos , Imagenología Tridimensional/efectos adversos , Recién Nacido , Embarazo , Seguridad , Ultrasonografía Prenatal/efectos adversos