Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Clin Nucl Med ; 49(4): e141-e148, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38350065

RESUMEN

PURPOSE: The aim of this study was to evaluate the diagnostic potential of 68 Ga-pentixafor PET/CT for in vivo CXCR4 receptors imaging in glioma and its possible role in response assessment to radiochemotherapy (R-CT). METHODS: Nineteen (12 men, 7 women) patients with glioblastoma multiforme (GBM) underwent 68 Ga-pentixafor PET/CT, contrast-enhanced MR, and MR spectroscopy. Patients were divided in to 2 groups, that is, group I was the presurgical (n = 9) group in which the scanning was done before surgery, and PET findings were correlated with CXCR4 receptors' density. The group II was the postsurgical (n = 10) group in which the scanning was done before and after R-CT and used for treatment response evaluation. The quantitative analysis of 68 Ga-pentixafor PET/CT evaluated the mean SUV max , SUV mean , SUV peak , and T/B values. MR spectroscopy data evaluated the ratios of tumor metabolites (choline, NAA, creatine). RESULTS: 68 Ga-Pentixafor uptake was noted in all (n = 19) the patients. In the group I, the mean SUV max , SUV mean , SUV peak , and T/B values were found to be 4.5 ± 1.6, 0.60 ± 0.26, 1.95 ± 0.8, and 6.9 ± 4.6, respectively. A significant correlation ( P < 0.005) was found between SUV mean and choline/NAA ratio. Immunohistochemistry performed in 7/9 showed CXCR4 receptors' positivity (intensity 3 + ; stained cells >50.0%). In the group II, the mean SUV max at baseline was 4.6 ± 2.1 and did not differ (4.4 ± 1.6) significantly from the value noted at post-R-CT follow-up PET/CT imaging. At 6 months' clinical follow-up, 4 patients showed stable disease. SUV max and T/B ratios at follow-up imaging were lower (3.70 ± 0.90, 2.64 ± 1.35) than the corresponding values (4.40 ± 2.8; 2.91 ± 0.93) noted at baseline. Six (6/10) patients showed disease progression, and the mean SUV max , and T/B ratio in these patients were significantly ( P < 0.05) higher than the corresponding values at baseline and also higher than that noted in the stable patients. CONCLUSIONS: 68 Ga-Pentixafor PET/CT can be used for in vivo mapping of CXCR4 receptors in GBM. The technique after validation in a large cohort of patients may have added diagnostic value for the early detection of GBM recurrence and for treatment response evaluation.


Asunto(s)
Complejos de Coordinación , Radioisótopos de Galio , Glioblastoma , Glioma , Péptidos Cíclicos , Masculino , Humanos , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones , Receptores CXCR4 , Glioma/diagnóstico por imagen , Glioma/terapia , Colina
2.
Nucl Med Commun ; 45(3): 229-235, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38165171

RESUMEN

OBJECTIVE: To evaluate the diagnostic utility of 68 Ga-Pentixafor PET/CT for in vivo imaging of CXCR4 receptors in soft tissue/bone sarcoma. METHODS: Ten (7M: 3F; mean age = 24.7 ± 14.2 years) consecutive patients with clinical and radiological evidence of bone/soft tissue sarcoma were recruited prospectively whole body 68 Ga-Pentixafor PET/CT imaging was performed at 60-min after tracer administration. After performing standard CT, PET acquisition from head to toe was done (3 min/bed position) in a caudocranial direction. PET/CT data was reconstructed and SUV max , SUV mean values, target-to-background ratio (TBR) and active tumor volume (cc) were computed for the tracer avid lesions. Histopathological and IHC analysis was performed on the surgically excised primary tumors. CXCR4 receptors' intensity was evaluated by visual scoring. RESULTS: The mean SUV max and SUV mean values in the primary tumors were 4.80 ±â€…1.0 (3.9-7.7) and 2.40 ±â€…0.60 (0.9-4.0). The mean TBR and tumor volume (cc) were 1.84 ±â€…1.3 and 312.2 ±â€…285. Diagnosis of osteosarcoma in 7, chondrosarcoma, leiomyosarcoma and synovial sarcoma in 1 patient each was confirmed on HP analysis. Distant metastatic lesions were seen in 3/10 patients. Nuclear CXCR4 receptors' positivity was seen in 5, cytoplasmic in 4 and both pattern seen in 1 patient. The mean CXCR4 receptors' intensity was found to be 7.6 ±â€…2. The highest SUV max value of 7.7 was observed in the patient having both cytoplasmic and nuclear CXCR4 expression. SUV max was found to be poorly correlated ( r  = 0.441) with CXCR4 expression. CONCLUSION: 68 Ga-Pentixafor PET/CT detects CXCR4 receptors over-expressed in sarcoma, its radio-theranostics potential needs detailed evaluation.


Asunto(s)
Complejos de Coordinación , Radioisótopos de Galio , Osteosarcoma , Sarcoma , Adolescente , Adulto , Niño , Humanos , Adulto Joven , Péptidos Cíclicos/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Receptores CXCR4/metabolismo , Masculino , Femenino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA