Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Card Surg ; 35(3): 710-712, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31971286

RESUMEN

As patient survival after cardiac transplantation has improved over the course of the last several decades, clinicians are now faced with late complications. This includes aortic stenosis which, traditionally, has been treated with reoperative sternotomy and aortic valve replacement. Transcather aortic valve replacement (TAVR) offers a minimally invasive alternative in this high-risk population. A small but growing number of cases of TAVR after heart transplantation in high-risk patients have been reported in the last 10 years; we now present a case of aortic valve replacement via a transcatheter approach 24 years after cardiac transplantation.


Asunto(s)
Válvula Aórtica/cirugía , Trasplante de Corazón , Complicaciones Posoperatorias/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Reoperación , Esternotomía , Factores de Tiempo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 89(2): E64-E74, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27220088

RESUMEN

BACKGROUND: 5% of patients undergoing coronary stenting have an indication for anticoagulation. The aim of our study was to determine the bleeding rates and complications in patients on triple oral antithrombotic therapy (TOAT) after coronary stenting. METHODS: We studied patients who underwent coronary stenting in our institution between 2003-2013 and were started on TOAT. Bleeding was the primary outcome. RESULTS: Totally, 999 patients were treated with TOAT with a median follow up of 127 days. All patients were treated with warfarin as an anticoagulant. 267 patients (26.7%) developed a total of 331 bleeding events. 100 patients had bleeding during the first 30 days of therapy. Major bleeding, minor bleeding, bleeding requiring medical attention, and minimal bleeding developed in 2.9%, 3.3%, 17.2%, and 3.3% of the patients respectively as their most significant bleeding event. Patients with anticoagulation initiated at time of stenting had a significantly higher bleeding rate compared to those already on chronic anticoagulation [adjusted HR (95% CI): 1.37 (1.03-1.79), P = 0.03]. The bleeding likelihood was significantly higher for patients with drug-eluted stents (DES) compared to bare-metal stents (BMS) [adjusted OR (95% CI): 1.52 (1.14 - 2.04), P < 0.05]. Patients with atrial fibrillation had an increased rate of bleeding after 6 month of initiation of TOAT with significantly worse outcomes. CONCLUSIONS: TOAT after coronary stenting is associated with high bleeding rates. Patients with AF had worse outcomes. Patients with newly initiated anticoagulation at time of stenting bleed significantly more than people already on chronic anticoagulation prior to stenting. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Anticoagulantes/efectos adversos , Aspirina/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/terapia , Fibrinolíticos/efectos adversos , Hemorragia/inducido químicamente , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/efectos adversos , Ticlopidina/análogos & derivados , Warfarina/efectos adversos , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Aspirina/administración & dosificación , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Clopidogrel , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Esquema de Medicación , Quimioterapia Combinada , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Ohio , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/administración & dosificación , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Stents , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Warfarina/administración & dosificación
3.
Stroke ; 47(9): 2339-46, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27507868

RESUMEN

BACKGROUND AND PURPOSE: Carotid artery revascularization was previously found to incrementally reduce stroke risk among patients with carotid stenosis treated with medical therapy. However, the frequency with which optimal medical therapies are used at discharge after carotid endarterectomy (CEA) and carotid artery stenting (CAS) is not known, and the influence of patient, operator, and hospital characteristics on the likelihood of prescription is poorly understood. METHODS: In a retrospective cohort study of 23 112 patients undergoing CAS or CEA between January 2007 and June 2012 at US hospitals participating in the CARE registry (Carotid Artery Revascularization and Endarterectomy), we examined antiplatelet therapy and statin utilization at discharge. Hierarchical multivariable logistic regression was used in adjusted analyses. RESULTS: Antiplatelet agents and statins were prescribed at discharge in 99% and 78%, respectively, after CAS and 93% and 75%, respectively, after CEA. After adjustment, antiplatelet therapy was more often prescribed after CAS than CEA (odds ratio 2.4 [95% confidence interval 1.68-3.45]), but statin prescription was equally likely (odds ratio 1.11 [95% confidence interval 0.84-1.49]). Operator specialty (medical>radiology/surgery) and hospital community setting (suburban>urban>rural) independently predicted antiplatelet and statin agent use at discharge, whereas hospital geographic location (Northeast>Midwest/South>West) predicted use of statins but not antiplatelet therapy at discharge. CONCLUSIONS: US antiplatelet agent and statin discharge prescription rates were suboptimal after both CAS and CEA and varied by revascularization modality, operating physician specialty, and hospital characteristics. Improved and more uniform utilization after these procedures will be critical to the success of comprehensive stroke risk reduction efforts.


Asunto(s)
Estenosis Carotídea/cirugía , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Anciano , Anciano de 80 o más Años , Estenosis Carotídea/tratamiento farmacológico , Prescripciones de Medicamentos , Endarterectomía Carotidea , Femenino , Adhesión a Directriz , Encuestas de Atención de la Salud , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estudios Retrospectivos , Stents
4.
Catheter Cardiovasc Interv ; 87(2): 188-99, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26602705

RESUMEN

Carotid artery stenting (CAS) has become an integral part of the therapeutic armamentarium offered by cardiovascular medicine programs for the prevention of stroke. The purpose of this expert consensus statement is to provide physician training and credentialing guidance to facilitate the safe and effective incorporation of CAS into clinical practice within these programs. Since publication of the 2005 Clinical Competence Statement on Carotid Stenting, there has been substantial device innovation, publication of numerous clinical trials and observational studies, accumulation of extensive real-world clinical experience and widespread participation in robust national quality improvement initiatives [5]. Collectively, these advances have led to substantial evolution in the selection of appropriate patients, as well as in the cognitive, technical and clinical skills required to perform safe and effective CAS. Herein, we summarize published guidelines, describe training pathways, outline elements of competency, offer strategies for tracking outcomes, specify facility, equipment and personnel requirements, and propose criteria for maintenance of CAS competency.


Asunto(s)
Angioplastia/educación , Angioplastia/instrumentación , Enfermedades de las Arterias Carótidas/terapia , Habilitación Profesional , Stents , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Angiografía Cerebral , Competencia Clínica/normas , Consenso , Habilitación Profesional/normas , Curriculum , Educación de Postgrado en Medicina/normas , Humanos , Valor Predictivo de las Pruebas , Sociedades Médicas/normas , Resultado del Tratamiento
5.
Stroke ; 46(6): 1525-32, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25953368

RESUMEN

BACKGROUND AND PURPOSE: It is not known whether racial or ethnic disparities observed with other revascularization procedures are also seen with carotid artery stenting (CAS) and endarterectomy (CEA). METHODS: We compared the utilization and outcomes of CAS and CEA across racial/ethnic groups within the CARE Registry between May 2007 and December 2012. RESULTS: Between 2007 and 2012, of the 13 129 patients who underwent CAS, majority were non-Hispanic whites (89.3%), followed by blacks (4.4%), Hispanics (4.3%), and other groups (2.0%). A similar distribution was observed among the 10 953 patients undergoing CEA (non-Hispanic whites, 92.6%; blacks, 3.5%; Hispanics, 2.8%; and other groups, 1.1%). During this time period, a trend toward proportionate increase in CAS utilization was observed in non-Hispanic whites and other groups, whereas the opposite was observed among Hispanics and blacks. This trend persisted even when hospitals performing both CAS and CEA were exclusively analyzed. Adherence to antiplatelet and statin therapy was significantly lower among blacks post CEA. In-hospital major adverse cardiac and cerebrovascular events remained comparable across groups post CAS and CEA. At 30 days, the incidence of stroke (7.2%) and major adverse cardiac and cerebrovascular events (8.8%) was higher among blacks post CEA (P<0.05), after risk adjustment. CONCLUSION: During the study period, utilization of CAS and CEA was highest among non-Hispanic whites. There was a trend toward increased CAS utilization over time among non-Hispanic whites and other groups, and a trend toward increased CEA utilization among Hispanics and blacks. In-hospital major adverse cardiac and cerebrovascular events remained comparable between groups, whereas 30-day major adverse cardiac and cerebrovascular events were significantly higher in blacks.


Asunto(s)
Negro o Afroamericano , Revascularización Cerebral/efectos adversos , Endarterectomía Carotidea/efectos adversos , Cardiopatías , Hispánicos o Latinos , Sistema de Registros , Accidente Cerebrovascular , Población Blanca , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Cardiopatías/epidemiología , Cardiopatías/etnología , Cardiopatías/etiología , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Incidencia , Masculino , Cumplimiento de la Medicación , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Stents , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etnología , Accidente Cerebrovascular/etiología , Estados Unidos
7.
Echocardiography ; 31(5): E145-6, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24495221

RESUMEN

This case highlights the utility of agitated saline studies during transesophageal echocardiography (TEE) for detection of pulmonary arteriovenous malformations (PAVM) as a viable alternative to contrast-enhanced imaging studies. By carefully studying each pulmonary vein individually during saline contrast studies, TEE is able to demonstrate and localize PAVM. In addition, this report represents the first documentation of PAVM arising as a complication of graft-versus-host disease after allogeneic hematopoietic stem cell transplant.


Asunto(s)
Malformaciones Arteriovenosas/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Enfermedad Injerto contra Huésped/diagnóstico por imagen , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Hipoxia/etiología , Arteria Pulmonar/anomalías , Venas Pulmonares/anomalías , Malformaciones Arteriovenosas/complicaciones , Diagnóstico Diferencial , Enfermedad Injerto contra Huésped/complicaciones , Humanos , Hipoxia/diagnóstico , Masculino , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen
8.
J Interv Cardiol ; 26(1): 77-83, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22958204

RESUMEN

OBJECTIVE: To assess the feasibility of endovascular repair of traumatic aortic injuries performed by interventional cardiologists in collaboration with cardiothoracic surgeons. BACKGROUND: Traumatic aortic injury (TAI) represents a significant cause of mortality in trauma patients. Endovascular techniques have recently come into play for the management of TAI and are usually performed by a multidisciplinary team consisting of a thoracic or vascular surgeon and/or interventional radiology. With extensive expertise in catheter-based interventions, interventional cardiologists may have a pivotal role in this important procedure. METHODS: From January 2009 to July 2011, we reviewed the TAI endovascular repair outcomes performed by a team of interventional cardiologists in collaboration with cardiothoracic surgery at our institution. The charts of these patients were reviewed to collect desired data, which included preoperative, procedural, and follow-up details. RESULTS: Twenty patients were identified in our series. Most of these patients developed TAI from motor vehicle accidents. Technical success for endovascular repair of TAI was achieved in all patients. Two patients developed endoleak, of which one patient required subsequent open repair. Two patients expired in the hospital from coexistent injuries. CONCLUSIONS: Our series of endovascular repair for TAI performed by interventional cardiologists with the collaboration of cardiothoracic surgeons showed excellent outcomes. Our experience may give further insight in the collaborative role of interventional cardiology and cardiothoracic surgery for endovascular repair of TAI.


Asunto(s)
Aorta/lesiones , Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Stents , Adolescente , Adulto , Anciano , Aortografía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Grupo de Atención al Paciente , Estudios Retrospectivos , Adulto Joven
9.
Vasc Med ; 18(1): 27-31, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23439777

RESUMEN

Since the long-term patency of axillofemoral (AXF) grafts is inferior to aorto-bifemoral (ABF) grafts, limb salvage procedures are crucial in this group of patients. Emerging endovascular devices have helped in the successful restoration of flow for acute limb ischemia in both native arteries as well as bypass grafts. One such device, the Trellis thrombectomy system is being used more frequently in this setting. The device has previously been used in veins, native arteries, and rarely in aortofemoral grafts. We present its first successful use for the treatment of occluded AXF bypass graft. The use of this device helped to isolate the treatment zone in the occluded graft, which allowed the use of a lower dose of thrombolytics, less systemic release of thrombolytics, and less distal embolization. Resolution of extensive clot burden was achieved and, with subsequent stenting of the graft at the distal anastomotic site, arterial flow to the leg through the AXF graft was restored and a revision surgery was avoided.


Asunto(s)
Arteria Axilar , Procedimientos Endovasculares , Arteria Femoral , Oclusión de Injerto Vascular/terapia , Trombolisis Mecánica , Terapia Trombolítica , Terapia Combinada , Humanos , Masculino , Persona de Mediana Edad
10.
Am J Emerg Med ; 30(7): 1322.e5-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21871757

RESUMEN

A 39-year-old man with HIV presented to the emergency department for evaluation of dyspnea accompanied by fever, diffuse chest discomfort, dry cough, and fatigue for past 1 week. The patient described his dyspnea as exertional progressing over 1 week to rest dyspnea. He was prescribed antiretroviral therapy but was noncompliant. He had no paroxysmal nocturnal dyspnea, orthopnea, rash, oral thrush, or diarrhea. His last record CD4+ lymphocyte count and HIV viral load were 43 cells/mm3 and 178,0000 copies/mL, respectively. Vital signs included a temperature of 101°F, heart rate of 115 beats per minute, respiratory rate of 16 per minute, and pulse oxygenation of 91% on room air. Lung examination revealed decreased breath sounds bilaterally, and the remainder of the examination was unrevealing. Laboratory findings revealed leukocytosis and increased serum lactate dehydrogenase of 577 U/L (90-190 U/L), and chest radiograph showed a right lower lobe infiltrate and perihilar, bilateral interstitial infiltrates (Fig. 1A).


Asunto(s)
Disnea/etiología , Infecciones por VIH/complicaciones , Hipoxia/etiología , Embolia Pulmonar/diagnóstico , Adulto , Disnea/diagnóstico , Disnea/diagnóstico por imagen , Humanos , Hipoxia/diagnóstico , Hipoxia/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Masculino , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Radiografía
11.
Echocardiography ; 29(1): E1-4, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-21988226

RESUMEN

During embryological development, an incomplete fusion of septum primum (SP) and septum secundum (SS) occurring cranially results in an inverted pouch-like structure with its base opening into the right atrium. This has been recently termed as right atrial septal pouch (RASP). Whether this pouch predisposes to intracardiac thrombosis by creating a milieu of localized stasis is unknown. Although some case reports have alluded to thromboembolic potential of left atrial septal pouch with similar origin, there has been no description regarding RASP acting as a thrombogenic nidus. We present a case of thrombus in the RASP with sequential imaging.


Asunto(s)
Ecocardiografía/métodos , Atrios Cardíacos/anomalías , Atrios Cardíacos/diagnóstico por imagen , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Anciano , Diagnóstico Diferencial , Femenino , Humanos
12.
JACC Case Rep ; 2(2): 305-308, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34317229

RESUMEN

Intra-aortic balloon pump via the axillary approach has been increasingly utilized to facilitate physical rehabilitation prior to definitive heart failure therapy. There is a high risk of device fracture with loss of arterial accessibility. Three cases are presented that demonstrate innovative arteriotomy hemostasis techniques for malfunctioning axillary intra-aortic balloon pumps. (Level of Difficulty: Intermediate.).

13.
Tex Heart Inst J ; 47(1): 10-14, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32148446

RESUMEN

The 6-minute walk distance (6MWD) test is a useful prognostic tool in chronic heart failure. Its usefulness after percutaneous coronary intervention is unknown. In a prospective observational study, patients underwent a 6MWD test within 2 weeks after percutaneous coronary intervention. The primary endpoint was major adverse cardiovascular events (MACE) (death, acute coronary syndrome, and heart failure admission) at one year. Receiver operating characteristic curves and area under the curve were used to determine the 6MWD test's predictive power, and the Youden index was used to measure its effectiveness. A total of 212 patients were enrolled (98% men; mean age, 65 ± 9 yr). Major comorbidities were hypertension in 187 patients (88%), dyslipidemia in 186 (88%), and diabetes mellitus in 95 (45%). Among the 176 patients (83%) who completed the 6MWD test, the incidence of MACE at one year was 22% (acute coronary syndrome in 17%; heart failure admission in 4%; and death in 3%). The area under the curve for MACE was 0.59, and 6MWD was shorter for patients with MACE than for those without (290 vs 326 m; P=0.03). For 39 patients with previous heart failure who completed the 6MWD test, the area under the curve was 0.64 for MACE and 0.78 for heart failure admission. The 6MWD test predicted reasonably well the incidence of MACE one year after percutaneous coronary intervention. In a subgroup of patients with previous heart failure, it fared even better in predicting heart failure admission. Larger studies are needed to confirm these findings.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Tolerancia al Ejercicio , Intervención Coronaria Percutánea , United States Department of Veterans Affairs , Prueba de Paso , Caminata , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Estado Funcional , Factores de Riesgo de Enfermedad Cardiaca , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Medición de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
16.
JACC Cardiovasc Interv ; 12(5): 422-430, 2019 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-30846079

RESUMEN

OBJECTIVES: The goal of this study was to investigate the trends, predictors, and outcomes of delayed discharge (>72 h) after transcatheter aortic valve replacement. BACKGROUND: Length of stay post-transcatheter aortic valve replacement may have significant clinical and administrative implications. METHODS: Data from the Transcatheter Valve Therapy Registry were used to identify patients undergoing nonaborted transfemoral transcatheter aortic valve replacement who survived to discharge, and data linked from the Centers for Medicare & Medicaid Services were used to provide 1-year events. Patients were categorized to early discharge (≤72 h) versus delayed discharge (>72 h). The trends, predictors, and adjusted 1-year outcomes were compared in both groups. RESULTS: From 2011 to 2015, a total of 13,389 patients (55.1%) were discharged within 72 h, whereas 10,896 patients (44.9%) were discharged beyond 72 h. There was a significant decline in rates of delayed discharge across the study period (62% vs. 34%; p < 0.01). This remained unchanged when stratified by Transcatheter Valve Therapy risk scores. Several factors were identified as independent predictors of early and delayed discharge. After adjustment for in-hospital complications, delayed discharge was an independent predictor of 1-year all-cause mortality (hazard ratio: 1.45; 95% confidence interval: 1.30 to 1.60; p < 0.01). CONCLUSIONS: Rates of delayed discharge have declined from 2011 to 2015. Delayed discharge is associated with a significant increase in mortality even after adjusting for in-hospital complications. Further work is necessary to determine if predictors of early discharge could be used to develop length of stay scores that might be instrumental in administrative, financial, or clinical policy development.


Asunto(s)
Válvula Aórtica/cirugía , Cateterismo Periférico/tendencias , Arteria Femoral , Tiempo de Internación/tendencias , Alta del Paciente/tendencias , Complicaciones Posoperatorias/terapia , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Punciones , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
17.
Cardiovasc Revasc Med ; 20(12): 1100-1104, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30826204

RESUMEN

PURPOSE: We investigated the outcomes of patients who underwent Transcatheter Aortic Valve Replacement (TAVR) with and without Balloon Aortic Valvuloplasty (BAV) using the SAPIEN 3 (S3) valve. METHODS: All patients who underwent TAVR using S3 valve were included. The primary outcomes were the incidence of stroke and significant paravalvular leak (PVL). Secondary outcomes were the incidence of mortality, balloon post dilation, and need for permanent pacemaker. RESULTS: From July-2014 to April-2018, 34 (9%) patients underwent BAV prior to TAVR and 344 (91%) patients underwent direct TAVR without BAV using the S3 valve. The Society of Thoracic Surgeons (STS) risk score was similar between two groups; 5.8 ±â€¯3.5 in no BAV group and 5.4 ±â€¯3.3 in BAV group, p = 0.53. After TAVR, 6 (1.7%) patients in no BAV group but no patient in BAV group developed stroke (p = 1.0). No patient had severe PVL and only 5 patients (1.3%) had moderate PVL at 30-day; 4 (1.2%) in no BAV group and 1 (2.9%) in BAV group (p = 0.38). Forty-six patients (13.4%) in the no BAV group and 4 (11.8%) patients in the BAV group needed balloon post dilation (p = 1.0). Six (1.6%) patients died during hospitalization, all in the no BAV group (p = 1.0). Forty-five (11.9%) patients needed new pacemaker implantation; 44 (12.8%) patients in no BAV group and 1 (2.9%) patient in BAV group (p = 0.1). Two-year survival rate was 85% in no BAV group and 84% in BAV group (p = 0.46). CONCLUSIONS: TAVR using S3 valves is associated with very low rates of post-TAVR stroke and significant PVL. Outcomes of direct TAVR are similar to the outcomes of TAVR with BAV, without an increased rate of stroke, significant PVL, or balloon post dilation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Valvuloplastia con Balón , Estimulación Cardíaca Artificial , Femenino , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
18.
Innovations (Phila) ; 14(3): 243-250, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31074313

RESUMEN

OBJECTIVE: Limited data is available about the effect of implanted valve size on prosthesis-patient mismatch (PPM) incidence and aortic gradient (AG) after transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). We compared PPM incidence and postprocedural AG between TAVR and SAVR patients considering the impact of implanted valve size. METHODS: From March 20, 2012, to September 30, 2015, 563 consecutive patients underwent TAVR (n = 419) or isolated SAVR (n = 144). Postprocedural transthoracic echocardiography was obtained within 30 days; AG, effective orifice area (EOA), and EOA index were calculated. RESULTS: A total of 381 patients in TAVR group and 82 patients in SAVR group were included. Mean preoperative AG and mean aortic valve area were not significantly different between the 2 groups. Postprocedural AG was significantly lower in TAVR than SAVR group, 7.74 ± 5.39 versus 14.27 ± 8.16 (P < 0.001). Between patients who had TAVR and SAVR with a valve size ≤23 mm, SAVR patients were 3 times more likely to have greater than mild AG after the procedure, OR: 3.1 (95% CI, 1.1 to 8.9) (P < 0.001). PPM incidence was significantly higher in SAVR group than TAVR group, 44 (53.7%) versus 112 (29.4%), OR = 2.8 (95% CI, 1.7 to 4.5) (P < 0.001). The PPM incidence was also higher in SAVR group than TAVR group among those who had the procedures with a valve size ≤23 mm, 35 (64.8%) versus 56 (47.9%), OR = 2 (95% CI, 1.1 to 3.9) (P = 0.048). Postprocedural outcomes were comparable between the 2 groups. CONCLUSIONS: In comparison to SAVR, TAVR is associated with less PPM and lower AG, especially in patients receiving a valve size ≤23 mm.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anatomía & histología , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estudios de Casos y Controles , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Diseño de Prótesis , Estudios Retrospectivos
19.
Cardiovasc Revasc Med ; 20(7): 612-618, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30126824

RESUMEN

OBJECTIVES: Individual randomized trials comparing drug-eluting balloons (DEB) versus everolimus-eluting stents (EES) for in-stent restenosis (ISR) were underpowered for clinical end-points. The objective of this study was to compare the clinical outcomes of DEB versus EES for any ISR. MATERIALS & METHODS: Electronic databases were searched for randomized trials which compared DEB versus EES for any ISR (i.e., drug eluting or bare metal stents). Summary estimate risk ratios (RRs) were constructed using a DerSimonian and Laird random effects model. RESULTS: Five trials with 962 patients were included. In-segment minimum lumen diameter (MLD) was lower with DEB (standardized mean difference -0.24, 95% confidence interval [CI] -0.46 - -0.01) on angiographic follow-up at a mean of 8.6 months. There was no statistically significant difference in the risk of target vessel revascularization (TVR) at 1 year (RR 1.15, 95% CI 0.60-2.19), but TVR was increased with DEB at 3 years (RR 1.87, 95% CI 1.15-3.03). The risk of target lesion revascularization (TLR) was statistically increased with DEB (RR 2.17, 95% CI 1.13-4.19) at a mean of 24.4 months. There was no difference in the risk of MI, stent thrombosis, cardiac mortality and all-cause mortality between both groups. CONCLUSION: In patients with any type of ISR, DEB was associated a similar risk of TVR at 1-year, but increased risk of TVR and TLR at longer follow-up, as compared with EES. The quality of evidence was moderate, suggesting the need for further randomized trials with longer follow-up to confirm the role of DEB in the management of ISR.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/mortalidad , Reestenosis Coronaria/fisiopatología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA