Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 21(4)2021 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-33668682

RESUMEN

This article covers the suitability to measure gait-parameters via a Laser Range Scanner (LRS) that was placed below a chair during the walking phase of the Timed Up&Go Test in a cohort of 92 older adults (mean age 73.5). The results of our study demonstrated a high concordance of gait measurements using a LRS in comparison to the reference GAITRite walkway. Most of aTUG's gait parameters demonstrate a strong correlation coefficient with the GAITRite, indicating high measurement accuracy for the spatial gait parameters. Measurements of velocity had a correlation coefficient of 99%, which can be interpreted as an excellent measurement accuracy. Cadence showed a slightly lower correlation coefficient of 96%, which is still an exceptionally good result, while step length demonstrated a correlation coefficient of 98% per leg and stride length with an accuracy of 99% per leg. In addition to confirming the technical validation of the aTUG regarding its ability to measure gait parameters, we compared results from the GAITRite and the aTUG for several parameters (cadence, velocity, and step length) with results from the Berg Balance Scale (BBS) and the Activities-Specific Balance Confidence-(ABC)-Scale assessments. With confidence coefficients for BBS and velocity, cadence and step length ranging from 0.595 to 0.798 and for ABC ranging from 0.395 to 0.541, both scales demonstrated only a medium-sized correlation. Thus, we found an association of better walking ability (represented by the measured gait parameters) with better balance (BBC) and balance confidence (ABC) overall scores via linear regression. This results from the fact that the BBS incorporates both static and dynamic balance measures and thus, only partly reflects functional requirements for walking. For the ABC score, this effect was even more pronounced. As this is to our best knowledge the first evaluation of the association between gait parameters and these balance scores, we will further investigate this phenomenon and aim to integrate further measures into the aTUG to achieve an increased sensitivity for balance ability.

2.
J Clin Oncol ; 42(2): 146-156, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-37906724

RESUMEN

PURPOSE: In patients with peritoneal metastasis (PM) from gastric cancer (GC), chemotherapy is the treatment of choice. Cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) are still being debated. This randomized, controlled, open-label, multicenter phase III trial (EudraCT 2006-006088-22; ClinicalTrials.gov identifier: NCT02158988) explored the impact on overall survival (OS) of HIPEC after CRS. PATIENTS AND METHODS: Adult patients with GC and histologically proven PM were randomly assigned (1:1) to perioperative chemotherapy and CRS alone (CRS-A) or CRS plus HIPEC (CRS + H). HIPEC comprised mitomycin C 15 mg/m2 and cisplatin 75 mg/m2 in 5 L of saline perfused for 60 minutes at 42°C. The primary end point was OS; secondary endpoints included progression-free survival (PFS), other distant metastasis-free survival (MFS), and safety. Analyses followed the intention-to-treat principle. RESULTS: Between March 2014 and June 2018, 105 patients were randomly assigned (53 patients to CRS-A and 52 patients to CRS + H). The trial stopped prematurely because of slow recruitment. In 55 patients, treatment stopped before CRS mainly due to disease progression/death. Median OS was the same for both groups (CRS + H, 14.9 [97.2% CI, 8.7 to 17.7] months v CRS-A, 14.9 [97.2% CI, 7.0 to 19.4] months; P = .1647). The PFS was 3.5 months (95% CI, 3.0 to 7.0) in the CRS-A group and 7.1 months (95% CI, 3.7 to 10.5; P = .047) in the CRS + H group. The CRS + H group showed better MFS (10.2 months [95% CI, 7.7 to 14.7] v CRS-A, 9.2 months [95% CI, 6.8 to 11.5]; P = .0286). The incidence of grade ≥3 adverse events (AEs) was similar between groups (CRS-A, 38.1% v CRS + H, 43.6%; P = .79). CONCLUSION: This study showed no OS difference between CRS + H and CRS-A. PFS and MFS were significantly better in the CRS + H group, which needs further exploration. HIPEC did not increase AEs.


Asunto(s)
Hipertermia Inducida , Neoplasias Peritoneales , Neoplasias Gástricas , Adulto , Humanos , Neoplasias Gástricas/tratamiento farmacológico , Neoplasias Gástricas/cirugía , Neoplasias Peritoneales/tratamiento farmacológico , Neoplasias Peritoneales/secundario , Quimioterapia Intraperitoneal Hipertérmica , Terapia Combinada , Procedimientos Quirúrgicos de Citorreducción/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Tasa de Supervivencia , Estudios Retrospectivos
3.
Assist Technol ; 32(1): 1-8, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-29482463

RESUMEN

To initiate appropriate interventions and avoid physical decline, comprehensive measurements are needed to detect functional changes in elderly people at the earliest possible stage. The established Timed Up&Go (TUG) test takes little time and, due to its standardized and easy procedure, can be conducted by elderly people in their own homes without clinical guidance. Therefore, cheap light barriers (LBs) and force sensors (FSs) are well suited ambient sensors that could easily be attached to existing (arm)chairs to measure and report TUG times in order to identify functional decline. We validated the sensitivity of these sensors in a clinical trial with 100 elderlies aged 58-92 years with a mean of 74 (±6.78) years by comparing the sensor-based results with standard TUG measurements using a stopwatch. We further evaluated the accuracy enhancement when calibrating the algorithm via a mixed linear model. With calibration, the LBs achieved a root mean square error (RMSE) of 0.83 s, compared to 1.90 s without, and the FSs achieved 0.90 s compared to 2.12 s without. The suitability of measuring accurate TUG times with each of the ambient sensors and of measuring TUG regularly in the homes of elderly people could be confirmed.


Asunto(s)
Evaluación Geriátrica/métodos , Locomoción , Accidentes por Caídas/prevención & control , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Tiempo de Reacción/fisiología , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA