1.
Sensors (Basel) ; 18(11)2018 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-30441772

RESUMEN

An Optical Frequency Domain Reflectometry (OFDR) based fiber optic sensor scheme "embedded" in concrete for the purpose of structural health monitoring (SHM) of carbon concrete composites (C³) is presented. The design, while strengthening the concrete structure, also aims to monitor common SHM parameters such as strain and cracks. This was achieved by weaving the carbon fiber together with optical fiber, based on a specialized technique that uses an embroidery setup where both the carbon and optical fiber are woven on a water dissolvable polymer substrate. The performance of the sensing scheme was characterized in-situ utilizing the OFDR based technique and the results presented. The sensors embedded on a custom made concrete block were subjected to varying strain via a three point bending test to destruction and the results discussed. The intended dual-achievement of the scheme thus proposed in SHM and strengthening the C³ is demonstrated. The suitability of the OFDR scheme for C³ is combined with a fibre Bragg grating (FBG)-based approach, and discussed in detail.

2.
Sensors (Basel) ; 17(2)2017 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-28208636

RESUMEN

Optical fiber-based sensors "embedded" in functionalized carbon structures (FCSs) and textile net structures (TNSs) based on alkaline-resistant glass are introduced for the purpose of structural health monitoring (SHM) of concrete-based structures. The design aims to monitor common SHM parameters such as strain and cracks while at the same time acting as a structural strengthening mechanism. The sensor performances of the two systems are characterized in situ using Mach-Zehnder interferometric (MZI) and optical attenuation measurement techniques, respectively. For this purpose, different FCS samples were subjected to varying elongation using a tensile testing machine by carefully incrementing the applied force, and good correlation between the applied force and measured length change was observed. For crack detection, the functionalized TNSs were embedded into a concrete block which was then exposed to varying load using the three-point flexural test until destruction. Promising results were observed, identifying that the location of the crack can be determined using the conventional optical time domain reflectometry (OTDR) technique. The embedded sensors thus evaluated show the value of the dual achievement of the schemes proposed in obtaining strain/crack measurement while being utilized as strengthening agents as well.

3.
Med Phys ; 47(10): e951-e987, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32862452

RESUMEN

The surface brachytherapy Task Group report number 253 discusses the common treatment modalities and applicators typically used to treat lesions on the body surface. Details of commissioning and calibration of the applicators and systems are discussed and examples are given for a risk-based analysis approach to the quality assurance measures that are necessary to consider when establishing a surface brachytherapy program.


Asunto(s)
Braquiterapia , Calibración , Dosificación Radioterapéutica , Informe de Investigación
4.
Med Phys ; 47(4): e65-e91, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31702063

RESUMEN

PURPOSE: The purpose of this study was to provide guidance on quality management for electronic brachytherapy. MATERIALS AND METHODS: The task group used the risk-assessment approach of Task Group 100 of the American Association of Physicists in Medicine. Because the quality management program for a device is intimately tied to the procedure in which it is used, the task group first designed quality interventions for intracavitary brachytherapy for both commercial electronic brachytherapy units in the setting of accelerated partial-breast irradiation. To demonstrate the methodology to extend an existing risk analysis for a different application, the task group modified the analysis for the case of post-hysterectomy, vaginal cuff irradiation for one of the devices. RESULTS: The analysis illustrated how the TG-100 methodology can lead to interventions to reduce risks and improve quality for each unit and procedure addressed. CONCLUSION: This report provides a model to guide facilities establishing a quality management program for electronic brachytherapy.


Asunto(s)
Braquiterapia/instrumentación , Equipos y Suministros Eléctricos , Informe de Investigación , Sociedades Médicas , Control de Calidad , Medición de Riesgo , Flujo de Trabajo