Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Surg Technol Int ; 432023 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-37972554

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the long-term clinical and hemodynamic results in patients affected by severe aortic valve disease after aortic valve replacement with third-generation stentless aortic prostheses (3F® stentless equine pericardial [Medtronic plc, Minneapolis Minnesota] and Pericarbon Freedom™ stentless bovine pericardial [LivaNova plc, London, United Kingdom]) and to analyze the benefits and the drawbacks associated to their use. MATERIALS AND METHODS: Between June, 2003 and Sept, 2015 a cohort of 548 consecutive patients affected by aortic valve disease received an aortic valve replacement using a last-generation stentless pericardial aortic prosthesis at our unit. Respectively, 322 patients received a Pericarbon Freedom™ and 226 received a 3F® aortic valve. Size ranged between 19 and 29, with prevalence of 23 and 25 devices. Mean age at operation was 71± 11 years, 57% of patients were males, the mean logistic EuroScore was 8.9 ± 7.2 and 44.2% received concomitant procedures. The mean extracorporeal circulation (ECC) time was 119.2 ± 40.6. The mean cross clamp time was 90.5' ± 21.4'. In 30 patients, the aortic prosthesis was included in a Dacron tube straight graft for a Bentall operation. RESULTS: Early/in-hospital mortality was 2.55% (14 cases) for the entire cohort. In patients receiving isolated aortic valve replacement (AVR), it was 0.91% (5 cases). Follow up ranged between six months and 12 years (median follow-up time: 6.77 years). During follow up, 137 patients died of all causes (25%), of whom 32 patients died of cardiac causes (5.8%). Cardiac survival probability was 91% at 12 years. All surviving patients were in NYHA class I at last follow up. Actuarial freedom from structural valve deterioration was 86% at 12 years. Freedom from endocarditis was 95% at 12 years. Freedom from a valve-related reoperation at 12 years follow up was 95%. Mean residual transprosthetic gradient at 12 years was 10.3 ± 4.8MmHg. CONCLUSIONS: Last-generation stentless pericardial valves offer excellent hemodynamics and adequate durability and freedom from structural deterioration at 12 years follow up. The implantation technique of a stentless valve is a little more demanding when compared to a stented valve, but it can be easily reproduced after minimal training. Incidence of endocarditis and thromboembolic events is low and comparable to stented pericardial valves. Young and active patients, and patients with large BSA where a patient-prosthesis mismatch may be anticipated are, in our opinion, ideal candidates to receive these kinds of valves.

2.
Surg Technol Int ; 422023 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-37466920

RESUMEN

Aortic annuloplasty has been clearly demonstrated to have a protective influence in aortic valve repair. Over the past 20 years, different annuloplasty concepts have been proposed by different groups. However, the most appropriate approach to enable long-term annular stability remains highly controversial. The aim of this article is to give a general overview of all types of aortic annuloplasty, particularly focusing on the use of an external Teflon ring, as proposed by our group. In this technique, external root dissection is performed in the same fashion as for reimplantation; the only difference is that it is necessary to go below the coronary ostia take-off. A series of pledgeted sutures (usually between 6 and 9 sutures) are placed at the level of the virtual basal ring. The external ring is made using a Teflon strip with a length of 8 to 9 cm, to reduce the annulus to a diameter of between 21 and 23 mm. The sub-annular sutures are then passed at the appropriate level through the Teflon strip and the strip is parachuted outside the aortic root base, passing under the coronary ostia. The two ends of the Teflon strip are tied at the level of the non-coronary sinus. Aortic annuloplasty is a crucial step to improve valve competence and stabilization. While several techniques offer good mid- to long-term results, annuloplasty with an external Teflon ring appears to be a simple and effective alternative to guarantee stable root diameters. Longer follow-up studies are needed to confirm the mid- to long-term results.

3.
J Card Surg ; 37(4): 781-788, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35092083

RESUMEN

OBJECTIVE: To compare the early and midterm clinical outcomes of patients undergoing two different surgical procedures (stentless biological Bentall [SBB] vs. valve-sparing David Reimplantation [VSDR]) for aortic root dilatation, with or without concomitant aortic valve pathology. METHODS: A population of 106 patients underwent aortic root replacement from 2004 to 2015 at our unit. Mean age at operation was 63.1 ± 10 years. The patients were retrospectively assigned to 2 groups according to surgical procedure. David operation was carried out in 52 patients (group A-VSDR) and stentless biological Bentall in 54 patients (group B-SBB). Preoperative characteristics were similar in the 2 cohorts, except for age and EuroSCORE. Mean follow-up time was 7.09 years (0.26-14.50 years), and 96% complete. Patients were evaluated and analyzed for intra-operative results and long-term clinical outcomes. RESULTS: Intraoperative mortality was 0% in both groups. Overall survival probability at 11 years was 91.8% in group A and 73.8% in group B (p = .004). Cardiac mortality at 11 years was similar in the 2 groups (p = .116). Freedom from structural valve deterioration at 11 years was 88.8% (VSDR) and 90.6% (SBB) [p = .689]. Freedom from reoperation at 11 years did not differ between the groups (83.6% VSDR vs. 98.5% SBB, p = .574). Freedom from major adverse cardiac and cerebrovascular events at 11 years was 76.7% (VSDR) versus 80.1% (SBB) (p = .542). Mean gradient at last follow-up was lower in VSDR group (8.13 vs. 11.70 mmHg, p < .001). CONCLUSIONS: David reimplantation and stentless biological Bentall procedures achieve excellent and comparable results at midterm follow-up. David operations provide superior hemodynamic performance preserved over time and may be preferred in younger, active patients.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Reoperación , Reimplantación , Estudios Retrospectivos , Resultado del Tratamiento
4.
J Card Surg ; 37(5): 1413-1415, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35152492

RESUMEN

We report an unusual case of black discoloration of an aortic root aneurysm and aortic valve cusps due to homogentisic acid deposition in a patient suffering from alkaptonuria. The patient underwent a valve-sparing aortic root replacement after careful and objective evaluation of the valve cusps. Despite alkaptonuria is classically associated with aortic valve stenosis and replacement, in the present case, the affected valve cusps were suitable for repair. To our knowledge, this is the first reported case of aortic valve-sparing procedure performed in a patient with alkaptonuria.


Asunto(s)
Alcaptonuria , Aneurisma de la Aorta Torácica , Estenosis de la Válvula Aórtica , Alcaptonuria/complicaciones , Aorta , Aneurisma de la Aorta Torácica/complicaciones , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Humanos
5.
Surg Technol Int ; 412022 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-36288241

RESUMEN

Patients affected by severe aortic root pathology require an operation to replace the dilated aortic root and repair or replace the aortic valve, which is very frequently involved in the disease. Among the surgical options available for aortic root replacement, the Bentall operation and the David aortic valve reimplantation procedure are the most commonly used by surgeons. This article provides an overview of the Bio-Bentall and David operations. It illustrates their surgical details and discusses the correct indications for both procedures to achieve excellent long-term outcomes. Finally, the authors present their experience with the physiologic treatment of aortic root pathology by using stentless Bio-conduits and David reimplantation in a cohort of patients with long-term follow-up. A comparative analysis of early and late results along with an evaluation of possible benefits and drawbacks related to each technique concluded that both procedures were effective in correcting the aortic root pathology, and the results were adequate and stable over time. Since hemodynamic performance was more improved after the David operation, it should be preferred, whenever feasible, in younger and active patients.

6.
Surg Technol Int ; 40: 235-240, 2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35179734

RESUMEN

An indefinitely lasting bioprosthesis that does not require anticoagulation treatment is the holy grail of substitutive heart surgery. However, this goal is not yet in sight with the present state of technology. Over the past few years, tremendous advances have been achieved regarding tissue anticalcification processes, hemodynamic performance and future-proofing by ensuring compatibility with transcatheter valve-in-valve procedures. The Inspiris Resilia valve (Edwards Lifesciences, Irvine, CA) was designed to incorporate all of these enhancements. It is now leaving the experimental phase and is being tested in the real world. We present here a comprehensive review of the evolution of biological prostheses, details of new anticalcification technologies, and early results of published studies as well as the experience at the European Hospital (Rome, Italy), the site of the first European implant and a leading center in various protocols. In our two years of experience with the Inspiris Resilia, there have been no cases of structural valve deterioration, endocarditis, detachment or periprocedural complication, and gradients seem to be superior to those with the previous generation of Edwards valves. While longer-term experience is clearly needed, the results thus far are encouraging.


Asunto(s)
Bioprótesis , Calcinosis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Calcinosis/cirugía , Humanos , Diseño de Prótesis
7.
J Card Surg ; 36(9): 3381-3383, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34091957

RESUMEN

We present the case of a 73-year-old male patient undergoing a modified Bentall-DeBono procedure in 2015 due to aortic stenosis and aortic aneurism involving the root. A bioprosthetic stented conduit made with a stented Edwards Perimount 21-mm bioprosthesis and a Vascutek Valsalva 28-mm Dacron graft was implanted along with a mitral annuloplasty. Five years later, due to early degeneration of the bioprosthesis and a progression of the mitral disease, he underwent a second surgical procedure where a Medtronic Mosaic 27-mm valve prosthesis was implanted in mitral position and a sutureless Livanova Perceval 23-mm valve in aortic position. Because of the difficulty in removing the previously implanted aortic prosthesis, the Perceval valve was inserted inside the frame of the PeriMount as an open "valve-in-valve" procedure. In October 2020, the patient underwent a ViV TAVI with a 23-mm Edwards Sapien 3 (Edwards Lifescience). After induction of general anesthesia and heparin administration, the procedure was performed via right femoral artery approach with preimplantation of two Proglides. After transfemoral insertion of a 14-French sheath, the aortic valve was crossed with a 0.035-in. straight guide-wire, taking care to avoid crossing the crowns of Perceval frame. After exchange of the standard wire with an extra-stiff 0.035-in. Safari wire, the Sapien-3 valve was advanced across the two previously implanted surgical valves and deployed at the level of the Perceval ring. After bioprosthesis deployment, peak-to-peak left ventricular aortic gradient was reduced from 51 to 16 mmHg.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Resultado del Tratamiento
8.
Surg Technol Int ; 38: 305-313, 2021 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-33970474

RESUMEN

Patients with symptomatic post-ischemic dilative myocardiopathy of the left ventricle require, in selected cases, an operation to reshape and reduce the volume of the left ventricular chamber, in addition to surgical myocardial revascularization and mitral valve repair, with the aim of prolonging survival, improving the quality of life and minimizing the need for re-hospitalizations related to recurrent heart failure. This procedure is called surgical ventricular restoration (SVR), and is a useful tool for the treatment of heart failure patients as an alternative to heart transplant. This article provides an overview of surgical ventricular restoration for the treatment of dilative ischemic myocardiopathy. It illustrates several surgical options, describes the operative details, and discusses the correct indications for the procedure. Finally, an interesting protocol for one-step cell therapy during SVR is proposed, as an innovative treatment for heart failure patients.


Asunto(s)
Cardiomiopatía Dilatada , Insuficiencia de la Válvula Mitral , Isquemia Miocárdica , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/cirugía , Ventrículos Cardíacos/cirugía , Humanos , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Calidad de Vida , Resultado del Tratamiento
9.
Surg Technol Int ; 38: 271-277, 2021 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-33724434

RESUMEN

In the original pre-formed Valsalva graft, the skirt is the defining feature. It is a self-expanding portion, obtained by 90° rotation of the Dacron fabric corrugation with respect to the rest of the graft. Due to this manufacturing feature, the skirt length is equal to the graft diameter and, once pressurized, it expands by 25-30% (up to 10 mm) from the nominal size. Proximal to this bulged portion, a small collar completes the prosthesis. By virtue of this anatomical design, the Valsalva graft is recommended for most aortic root surgeries including valve-sparing and Bentall procedures. The skirt, by recreating the pseudo-sinuses, represents the key feature of the graft when used for aortic valve-sparing procedures (remodeling and reimplantation). However, in the Bentall procedure, the graft collar is an important feature because it is useful to attach the Valsalva graft to the valve prosthesis sewing ring when making a valved conduit. Moreover, once the graft is pressurized, the whole volume of the skirt better accommodates the struts and the leaflets of biological and mechanical prostheses. Furthermore, the expanded skirt reduces the distance and the tension on the coronary button anastomosis, increasing safety and possibly reducing complication rates. This review demonstrates the versatility of the Valsalva graft in various scenarios of aortic root surgery, with special emphasis on different uses of the skirt and the collar.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Aorta/cirugía , Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reimplantación
10.
Surg Technol Int ; 39: 321-328, 2021 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-34710946

RESUMEN

BACKGROUND: Low preoperative haemoglobin is frequently observed in heart surgery patients and is associated with a significant decrease in haemoglobin between post-operative days 2 and 3, known as haemoglobin drift. Overall, these patients tend to receive many RBC transfusions. Since iron homeostasis is often impaired in these patients, restoration of iron availability might override iron-restricted erythropoiesis. However, reduced tolerance to oral iron salts has limited this strategy to intravenous iron administration. STUDY DESIGN AND METHODS: The purpose of this study was to assess whether preoperative supplementation with oral sucrosomial iron, a new iron-delivery technology with improved tolerance and bioavailability, might be an effective strategy for this patient population. One thousand consecutive patients were randomized and received either a one-month course of sucrosomial iron (60 mg/day) or no treatment prior to elective heart surgery at a single high-volume centre (ClinicalTrials.gov NCT03560687). Primary end-points were haemoglobin concentration on the day of hospital admittance and number of blood transfusions. Secondary end-points were haemoglobin drift, tolerance of treatment and cost-effectiveness of sucrosomial iron administration. RESULTS: Baseline haemoglobin in the treatment group was higher (by 0.67 g/dL; p<0.001) than that in the control group. The percentage of patients in the treatment group who required transfusion (35.4%) was half that in the control group (64.6%). The average number of transfused units per operation was 0.95 vs. 2.03 in the treatment and control groups, respectively. Haemoglobin drift was substantially similar in the two groups, and the tolerability of treatment was excellent (98%). The overall cost of treatment was 156 Euros less in the treatment group, expressed as a raw cost of transfusion. CONCLUSION: In elective heart surgery, routine preoperative sucrosomial iron administration seems to be a safe, well-tolerated and cost-effective strategy to increase preoperative haemoglobin and reduce the need for allogeneic blood transfusions.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hierro , Transfusión Sanguínea , Suplementos Dietéticos , Compuestos Férricos , Hemoglobinas , Humanos , Estudios Prospectivos
11.
J Card Surg ; 35(5): 988-995, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32176376

RESUMEN

BACKGROUND: To analyze the long-term results after Bentall operation using the stentless Shelhigh No-React (NR)-2000 bio-root prosthesis. MATERIAL: From 2004 to 2008, 26 consecutive, nonselected patients (mean age at surgery: 67 ± 9 years) underwent a Bentall operation using a stentless Shelhigh valved conduit at our institution. Mean preoperative Logistic-EuroSCORE was 17.1 ± 12.9. The mean size of the aortic root was 53.2 ± 5 mm. The mean preoperative ejection fraction was 55 ± 7.4%. Three patients had a bicuspid valve. One patient with acute endocarditis and one patient with type A aortic dissection were operated on an emergency. Three patients (11.54%) had a previous cardiac operation. The Button-Bentall technique was used in all cases. Seven patients (26.92%) received an associated procedure. The mean size of the implanted prosthesis was 26.1 ± 2.2. Follow-up ranged between 6 and 174 months (mean 93.4 ± 59.1 months). Primary endpoints consisted of early and late mortality, freedom from acute endocarditis, freedom from structural valve deterioration, and freedom from valve-related-reoperation. RESULTS: Two patients died in hospital, while 10 patients died during follow-up time, of which three for cardiac causes (12.5%). Overall survival probability was 52.9% at 15 years. Freedom from acute endocarditis was 95.7% at 5 and 15 years. Freedom from severe aortic incompetence due to structural deterioration was 100% at 5 and 10 years, 90.9% at 15 years. The mean aortic gradient at follow-up was 11.4 ± 5 mm Hg. Freedom from valve-related reoperation was 100% at 5 and 10 years, 90.9% at 15 years. CONCLUSIONS: In our experience, Bentall's operation using the Shelhigh NR-2000 stentless bio-conduit provided satisfactory early and long-term results. However, our findings are not consistent with unfavorable long-term outcomes following the implantation of this device reported by other authors.


Asunto(s)
Disección Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Endocarditis Bacteriana/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Enfermedad de la Válvula Aórtica Bicúspide , Bioprótesis , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
12.
J Card Surg ; 35(7): 1548-1555, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32490568

RESUMEN

BACKGROUND: The aim of this multicenter prospective study was to evaluate the prognostic weight of preoperative right ventricular assessment on early mortality in cardiac surgery. METHODS: This is a multicenter prospective observational study performed by the Italian Group of Research for Outcome in Cardiac Surgery (GIROC) including 11 centers. From October 2017 to March 2019, out of 923 patients undergoing cardiac surgery, 28 patients with some missing data were excluded and 895 patients were enrolled in the study right ventricular dilatation was defined as a basal end-diastolic diameter >42 mm. The right ventricle (RV) function was assessed using the combination of three parameters: fractional area changing (FAC), tricuspid annular plane systolic excursion (TAPSE), and S'-wave using tissue Doppler imaging (TDI-S'); RV dysfunction was defined as the presence of at least two of the following cutoffs: FAC <35%, TAPSE <17 mm, and TDI S' <9.5 mm RESULTS: Among the entire cohort, 624 (70%) showed normal RV, 92 (10%) isolated RV dilatation, 154 (17%) isolated RV dysfunction, and 25 (3%) both RV dilatation and dysfunction. Non-surviving patients showed a significantly higher rate of RV alteration at multivariable analysis, RV status was found to be an independent predictor for higher in-hospital mortality beside Euroscore II. CONCLUSIONS: This prospective multicenter observation study shows the importance to assess RV preoperatively and to include both RV function and dimension in a risk score model such as Euroscore II to implement its predictivity, since PH cannot always mirror the status of the right ventricle.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Ventrículos Cardíacos/patología , Evaluación de Resultado en la Atención de Salud/métodos , Proyectos de Investigación , Función Ventricular Derecha , Adulto , Anciano , Anciano de 80 o más Años , Dilatación Patológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Preoperatorio , Pronóstico , Estudios Prospectivos , Riesgo , Disfunción Ventricular Derecha , Adulto Joven
13.
Surg Technol Int ; 35: 197-201, 2020 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-32120449

RESUMEN

INTRODUCTION: Progressive saphenous vein graft (SVG) failure remains a key limitation to the long-term success of coronary artery bypass grafting (CABG). SVG disease after the first year is dominated by intimal hyperplasia, which predisposes the SVG to thrombosis and accelerated atherosclerosis. The objective of this study was to review and summarize the latest experimental and clinical data on the use of mechanical external stents for vein grafts. METHODS: In January 2020, the PubMed database was searched using the terms "external stent", "CABG", "saphenous vein graft" and "intimal hyperplasia". The results were reviewed and only randomized experimental and clinical studies that analyzed the effect of external stenting on venous intimal hyperplasia were included in the analysis, together with studies that investigated the clinical benefit of external stenting. RESULTS: Eight experimental and four clinical trials met the search criteria. Controlled trials in different large animal models concluded that external stenting significantly reduced intimal hyperplasia 3-6 months post implantation, and reduced both thrombosis rates and the development of lumen irregularities. Data from randomized controlled trials with a follow-up period of 1-4.5 years supported the pre-clinical findings and demonstrated that external stents significantly reduced vein graft disease. CONCLUSION: Strong evidence indicates that supporting the vein with external stents is safe and leads to clear advantages at both the anatomical and cellular levels. With the further accumulation of consistent positive results, external stenting of SVG may become the standard of care in future CABG.


Asunto(s)
Puente de Arteria Coronaria/métodos , Oclusión de Injerto Vascular/prevención & control , Vena Safena/trasplante , Stents , Túnica Íntima/patología , Animales , Aterosclerosis/etiología , Aterosclerosis/prevención & control , Implantación de Prótesis Vascular/métodos , Oclusión de Injerto Vascular/etiología , Humanos , Hiperplasia/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Vena Safena/cirugía , Trombosis/etiología , Trombosis/prevención & control , Túnica Íntima/cirugía , Grado de Desobstrucción Vascular
14.
J Interv Cardiol ; 2019: 8586927, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31772548

RESUMEN

OBJECTIVES: The aim of this study is to assess long-term-outcomes of patients with concomitant CAD and COD treated with different revascularization strategies. BACKGROUND: Multisite artery disease is common and patients with combined disease have poor prognosis. The best therapeutic strategy for patients with concomitant carotid obstructive disease (COD) and coronary artery disease (CAD) remains controversial. METHODS: This observational registry enrolled, between January 2006 and December 2012, 1022 consecutive patients from high volume institutions with concomitant CAD and COD suitable for endovascular, surgical, or hybrid revascularization in both territories selected by consensus of a multidisciplinary team. RESULTS: The cumulative incidence of 5-year major cardiovascular events (MACCE) including cardiovascular death, myocardial infarction (MI), or stroke in the overall population was 12%. The incidence of 5-year MACCE was not statistically different in the surgical, endovascular, or hybrid patients group (10.1% vs. 13.0% vs. 13.2%, P = .257, respectively). However, the hybrid group exhibited rates of myocardial infarction, chronic kidney disease, and cumulative incidence of all clinical events higher than the surgical group. After propensity score matching, the incidence of 5-year MACCE was similar in the three groups (13.0% vs. 15.0% vs. 16.0%, p = .947, respectively). CONCLUSIONS: An individualized revascularization approach of patients with combined CAD and COD yields very good results at long-term follow-up, despite the high risk of this multilevel population even when the baseline clinical features are equalized.


Asunto(s)
Enfermedades de las Arterias Carótidas/cirugía , Revascularización Cerebral , Enfermedad de la Arteria Coronaria/cirugía , Efectos Adversos a Largo Plazo , Revascularización Miocárdica , Anciano , Enfermedades de las Arterias Carótidas/diagnóstico , Enfermedades de las Arterias Carótidas/epidemiología , Revascularización Cerebral/efectos adversos , Revascularización Cerebral/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/estadística & datos numéricos , Femenino , Humanos , Incidencia , Italia/epidemiología , Efectos Adversos a Largo Plazo/clasificación , Efectos Adversos a Largo Plazo/epidemiología , Efectos Adversos a Largo Plazo/etiología , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/efectos adversos , Revascularización Miocárdica/métodos , Evaluación de Resultado en la Atención de Salud , Sistema de Registros/estadística & datos numéricos , Factores de Riesgo
15.
Blood Purif ; 47 Suppl 3: 1-5, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30982024

RESUMEN

BACKGROUND: Extracorporeal treatment may be useful during sepsis, but definitive recommendations are lacking. Aim of this study is to review retrospectively the medical records of septic patients submitted to continuous renal replacement therapy (CRRT) with the adsorbing membrane oXiris and evaluate (1) the safety of the device, (2) the cardiorenal response, and (3) the immunological response. MATERIALS AND METHODS: The medical records of 60 septic patients submitted to CRRT with the membrane oXiris from April 2011 to December 2018 have been reviewed. The adsorbing membrane oXiris® (Baxter, IL, USA) was used through a Prisma plataform (Prismaflex - Baxter, IL, USA). At basal time (T0), at 24 h (T1), and at the end of the treatment (T2) were analyzed the clinical data, the cytokines, and the time course of endotoxin. RESULTS: Sixty patients were included in the study. In total, 85% of patients had acute kidney injury (AKI). Every CRRT treatment was of 72 ± 13 h, with the consumption of 3.2 ± 1 filters. No AE events were reported. The main cardiorenal and respiratory parameters improved with a decrease of the noradrenaline dosage. Cytokines, procalcitonin, and endotoxin activity assay decreased too. SOFA total improved from 12.4 ± 2 to 9 ± 2. CONCLUSION: In sepsis/septic shock patients with AKI, CRRT with the adsorbing membrane oXiris may be safe and improves the cardiorenal - function and the clinical condition. The effect on cytokines and endotoxin may explain in part these results. A RCT is warranted to confirm these data.


Asunto(s)
Lesión Renal Aguda/terapia , Membranas Artificiales , Terapia de Reemplazo Renal , Sepsis/terapia , Lesión Renal Aguda/sangre , Anciano , Citocinas/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Terapia de Reemplazo Renal/instrumentación , Terapia de Reemplazo Renal/métodos , Estudios Retrospectivos , Sepsis/sangre
16.
Surg Technol Int ; 35: 217-232, 2019 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-31476790

RESUMEN

This is the third and final part of our update on the latest advances in cardiac valvular replacement. Part 1 was dedicated to cardiac valvular replacement, and Part 2 focused on transcatheter cardiac valvular treatment. This part concerns annuloplasty prostheses for valvular reconstructive surgery. The number of patients undergoing surgical heart valve repair has been increasing, particularly in high-volume centers. Annuloplasty is now considered the gold standard in mitral valve regurgitation repair secondary to degenerative, ischemic and idiopathic dilated cardiomyopathy disease. The techniques of mitral valve reconstruction have been well established, but controversies remain regarding the type of annuloplasty ring to be used. The available annuloplasty rings include rigid, flexible, complete, partial, and semi-rigid/flexible. The choice of annuloplasty ring has been the focus of extensive investigation and debate, but to date it still largely remains a matter of "surgeon's preference" rather than an evidence-based selection. Functional tricuspid regurgitation was traditionally treated by the classic De Vega annuloplasty, but has since evolved after the development of prosthetic tricuspid annuloplasty. Head-to-head comparisons have demonstrated superior long-term outcomes with device-based annuloplasty compared to suture-based surgery, but the type of ring to be used (flexible versus rigid) has recently been questioned, without reaching definitive conclusions. In contrast to mitral and tricuspid valve repair, aortic repair is more difficult with respect to specific valve features. Annuloplasty is considered to play a key role in controlling aortic regurgitation and preventing recurrence after valve repair. Various modifications of annuloplasty have been advocated (internal/external, with/without ring (suture), rigid/flexible ring). but none of them has become a de facto standard. This paper describes the various rings that are available to help orient surgeons and to serve as a reference for students.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Mitral , Anuloplastia de la Válvula Mitral/métodos , Resultado del Tratamiento , Válvula Tricúspide , Insuficiencia de la Válvula Tricúspide/cirugía
17.
Surg Technol Int ; 33: 219-237, 2018 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-30204929

RESUMEN

When the original monograph on valvular prostheses was published in Surgical Technology International, back in 1993, transcatheter technology had not yet been invented. These techniques have been gradually revealed in subsequent issues. When we first considered writing a paper that described both surgical and transcatheter prosthesis, we realized that such a combined paper would be impractically large. Therefore, we decided to split our survey into more than one paper. This paper seeks to address the paucity of information available regarding transcatheter aortic valve implantation (TAVI) and similar devices. This publication may serve as a reference point for critically organizing information on an evolving topic. The following article deals with the large number of transcatheter devices related to valvular and ventricular pathologies: TAVI for the aortic and mitral valves, with a focus on indications, techniques and complications, as well as specific aortic devices, and devices to treat mitral regurgitation with non-conventional access. Every effort has been made to make the content relevant and up-to-date, which proved to be particularly challenging due to the continuous technological evolution which characterizes this field.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades de las Válvulas Cardíacas/cirugía , Válvulas Cardíacas/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
18.
Surg Technol Int ; 32: 175-189, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29669161

RESUMEN

The original monograph on valvular prostheses in Surgical Technology International was published in 1993. It represents a milestone and a reference point for critically organizing information on a complex and rapidly evolving topic. The last update was published in 2010. Since then, there have been significant developments regarding both "traditional" surgical prosthesis and valves for transcatheter implantation. Both bioprostheses and mechanical prostheses continue to evolve with respect to both their design and materials to further optimize hemodynamics and prevent a patient-prosthesis mismatch. Each type of prosthesis has its own Achilles's heel: limited durability leading to structural failure for bioprostheses, and the need for anticoagulation for mechanical prostheses. After a long period of only marginal improvements, new techniques for tissue preservation and manufacturing seem to have placed surgeons on the verge of a minor revolution regarding bioprostheses. In addition, in the realm of mechanical prostheses, the many promises of silicon-free pyrolitic carbon still need to be confirmed, while an extremely cautious approach with new anticoagulants has left patients out of the non-dose-adjusted revolution, which has radically improved the quality of life of other patients, such as those suffering from atrial fibrillation. On the other hand, transcatheter therapies are maturing, and the next few years will probably see an even stronger shift in the treatment of patients away from surgical theaters to cath labs, or perhaps to a new mixed theater (which could lead to a new mixed surgeon/catheter expert professional). This paper provides device descriptions and images of the technologies that are considered to be predominant, at least for the moment, to help orient surgeons and to serve as a reference for students. This report would not have been possible without the prior work of Profs. Denton Cooley and Eric Jamieson.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Calidad de Vida
19.
J Heart Valve Dis ; 26(5): 518-527, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-29762920

RESUMEN

BACKGROUND: The study aim was to investigate the hemodynamic behavior over time and ease of implant and durability of the Sorin Pericarbon Freedom (SPF)® stentless pericardial aortic xenograft. METHODS: Between March 2003 and April 2010, a total of 251 consecutive, non-selected patients (mean age 70.1 years; range: 17-89 years; 17.1% aged >80 years) received a SPF bioprosthesis as an aortic valve substitute at the authors' institution. All implantations were performed by a single surgeon using a classical, double-line, subcoronary implant technique. Of these patients. 108 (43%) underwent a concomitant procedure. The mean logistic EuroSCORE was 8.3. Patients were followed for complications and hemodynamic evaluation. Echocardiographic controls and clinical data were obtained at discharge, and at six months' and eight years' follow up. RESULTS: The in-hospital/30-day mortality was 1.2% for the entire group, but 0% for patients with isolated valve replacement. A total of 27 deaths had occurred at the time of the last follow up (22 were due to non-cardiac causes). At follow up (mean 3.7 years; range: 0-7.8 years), 91.1% of survivors were in NYHA classes I or II. Freedom from reoperation and from structural valve deterioration was 96.0% and 96.8%, respectively, at 7.8 years. The mean pressure gradient of the series (measured using echocardiography) was 10.3 ± 4.5 mmHg at discharge, and 8.3 ± 4.5mmHg at the time of the last follow up. The mean effective orifice area was 1.85 ± 0.70 cm2 for the entire series, and there was an absence of prosthesis-patient mismatch in 90% of patients. CONCLUSIONS: The study results confirmed the favourable hemodynamic behavior, low risk of implantation and acceptable durability of the pericardial stentless SPF aortic prosthesis. The data also endorsed use of the SPF as an aortic valve substitute, even in a young and active population, and particularly in the presence of a small aortic annulus. The accuracy of implantation remains a crucial factor for durability and subsequent satisfactory hemodynamic performance. A longer follow up would provide further information with regards to complications and durability of the SPF prosthesis.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Italia , Masculino , Persona de Mediana Edad , Pericardio/trasplante , Falla de Prótesis , Trasplante Heterólogo/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA