Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Acta Obstet Gynecol Scand ; 101(6): 639-648, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35301710

RESUMEN

INTRODUCTION: The incidence of placenta accreta spectrum (PAS) has increased, but the optimal management and the optimal way to achieve vascular control are still controversial. This study aims to compare maternal outcomes between different methods of vascular control in surgical PAS management. MATERIAL AND METHODS: A retrospective cohort study on consecutive cases diagnosed with PAS between 2013 and 2020 in single tertiary hospital. The final diagnosis of PAS was made following preoperative ultrasound and confirmation during surgery. Management of PAS using cesarean hysterectomy with internal iliac artery ligation (IIAL) was compared with two types of vascular control in uterine conservative-resective surgery (IIAL vs identification-ligation of the upper vesical, upper vaginal, and uterine arteries). RESULTS: Over an 8-year period, 234 pregnant women were diagnosed with PAS meeting the inclusion criteria. Uterine conservative-resective surgery (200 cases) was associated with lower mean blood loss compared with cesarean hysterectomy with IIAL (34 cases) in all PAS cases (1379 ± 769 mL vs 3168 ± 1916 mL; p < 0.001). In sub-analysis of the two uterine conservative-resective surgery subgroups, the group with identification-ligation of the upper vesical, upper vaginal, and uterine arteries had a significantly lower blood loss compared with uterine conservative-resective surgery with IIAL (1307 ± 743 mL vs 1701 ± 813 mL; p = 0.005). Women in the hysterectomy with IIAL group had more massive transfusion (35.3% vs 2.5%; p < 0.001; odds ratio [OR] 21.3, 95% confidence interval [CI] 6.9-66), major blood loss (>1500 mL) (70.6% vs 34%, p < 0.001; OR 4.7; 95% CI 2.1-10.3), catastrophic blood loss (>2500 mL) (64.7% vs 12.5%;p < 0.001; OR 12.8, 95% CI 5.7-29.1), other complications (32% vs 12.4%; p = 0.007; OR 3.4, 95% CI 1.5-7.7), and intensive care unit admission (32.4% vs 1.5%; p < 0.001; OR 31.4, 95% CI 8.2-120.7) compared with the uterine conservative-resective surgery groups. The identification-ligation of the upper vesical, upper vaginal and uterine arteries had a significant lower risk for major blood loss (30.5% vs 50%; p = 0.041; OR 0.44, 95% CI = 0.2-0.9) compared with IIAL for vascular control of uterine conservative-resective surgery. CONCLUSIONS: Cesarean hysterectomy is not the default treatment for PAS, PAS with invasion above the vesical trigone are suitable for uterine conservative-resective surgery with upper vesical, upper vaginal and uterine artery vascular control.


Asunto(s)
Placenta Accreta , Cesárea , Femenino , Hemorragia/cirugía , Humanos , Histerectomía/métodos , Arteria Ilíaca/cirugía , Placenta Accreta/diagnóstico por imagen , Placenta Accreta/cirugía , Embarazo , Estudios Retrospectivos
2.
J Clin Ultrasound ; 47(1): 9-13, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30246313

RESUMEN

OBJECTIVE: This study aimed to determine the role of three-dimensional (3D)/four-dimensional (4D) volume rendering ultrasound (VRU) in the diagnosis of abnormally invasive placenta (AIP). MATERIALS AND METHODS: Twelve consecutive patients strongly suspected of having AIP on the basis of conventional ultrasound (US) and clinical history performed between September 2016 and December 2016 in the main tertiary referral hospital in Surabaya, East Java were included in this prospective observational study. A Samsung WS 80A Elite US scanner with a 3D/4D "crystal vue" and "realistic vue" volume rendering mode was used to establish the diagnosis of AIP and evaluate the site, and depth of placental invasion. The VRU images were compared with the intraoperative findings. RESULTS: Using this novel US technique, all cases of suspected AIP were subsequently confirmed during surgery. Importantly, the new US technique provided a correct diagnosis of the degree of invasion in 11 out of these 12 suspected AIP cases: 5/5 for placenta percreta, 3/3 for placenta increta, and 2/3 for placenta accreta; one patient was misdiagnosed in terms of the degree of placenta accreta, and one patient had normal implantation). CONCLUSION: This new software of 3D/4D VRU represents a promising technique for the preoperative diagnosis and staging of AIP.


Asunto(s)
Imagenología Tridimensional/métodos , Placenta Accreta/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Adulto , Femenino , Humanos , Placenta/diagnóstico por imagen , Embarazo , Estudios Prospectivos , Adulto Joven
3.
Hypertens Pregnancy ; 37(4): 175-181, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30277426

RESUMEN

OBJECTIVE: To compare the level of serum heme oxygenase 1 (HO-1), soluble FMS like tyrosine kinase (sFlt-1), and neonatal outcome in early onset preeclampsia (EO-PE), late onset preeclampsia (LO-PE), and normal pregnancy (NP). METHODS: In this prospective observational case control study, HO-1 and sFlt-1 levels were measured in blood samples within 24 h of hospital admission. Preeclampsia cases were divided into two groups based on gestational age at delivery: EO-PE (<34 weeks) and LO-PE (≥34 weeks). A total of 45 patients were involved in this study. RESULT: Maternal serum level of sFlt-1 was higher in EO-PE than LO-PE and NP groups (mean ± SD; 14.50 ± 17.12 ng/ml vs 5.20 ± 6.69 ng/ml vs 2.72 ± 1.2 ng/ml [p = 0.020]. Maternal serum level of HO-1 was not different between EO-PE, LO-PE, and NP groups (p = 0.681). Birthweights were significantly lower in the EO-PE group compared with the LO-PE and NP groups (1580 ± 536 g vs 2635 ± 578 g vs 3010 ± 371 g [p = 0.000]). The rate of small for gestational age infant (26.7% vs 6.7% vs 0%; p = 0.046) and perinatal death (20% vs 0 vs 0; p = 0.037) was also significantly higher in EO-PE compared to LO-PE and NP. The maternal sFlt-1 level was negatively correlated with birthweight (p = 0.006; CC = -0.445). CONCLUSION: This study did not find a correlation between maternal HO-1 levels and sFlt-1 levels. Maternal serum sFLt-1 levels in preeclampsia were higher in EO-PE and were associated with a worse perinatal outcome.


Asunto(s)
Peso al Nacer/fisiología , Hemo-Oxigenasa 1/sangre , Parto/sangre , Preeclampsia/sangre , Receptor 1 de Factores de Crecimiento Endotelial Vascular/sangre , Adulto , Estudios de Casos y Controles , Femenino , Edad Gestacional , Humanos , Embarazo , Resultado del Embarazo , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA