Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Craniofac Surg ; 35(1): 80-84, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37888998

RESUMEN

OBJECTIVE: The cosmetically good coverage of skull defects is a challenge in neurosurgical clinics. In addition, the skull treated with implants and the underlying structures must remain radiologically assessable. In this examination, the postoperative courses of patients after implantation of CranioTop is described. Digital x-ray, computed tomography, and magnetic resonance images after implantation of CranioTop were evaluated with regard to their assessability. MATERIALS AND METHODS: Between 2018 and 2020, 23 titanium cranioplasties (CranioTop) were implanted to 21 patients. The intraoperative handling, the accuracy of fit, the healing process, the cosmetic result and the physical condition of the patients were examined. In addition, digital x-rays, magnetic resonance imaging, and computed tomography scans of the cranium supplied with CranioTop were examined. RESULTS: The evaluation showed good to very good results regarding patients' satisfaction. There were no severe complications; thirteen patients found the cosmetic result very good; 8 patients assessed the cosmetic result as good. Because of the low thickness and density of the CranioTop plastic there was only low formation of radial stripe artifacts (streaking) and susceptibility artifacts. The assessment of digital x-ray, computed tomography, and magnetic resonance imaging images is possible after implantation of CranioTop. CONCLUSION: The patients treated with CranioTop showed a high level of satisfaction with regard to the cosmetic result and their physical condition. Furthermore, the cranium supplied with CranioTop remains well assessable in radiologic imaging with only slight limitations in magnetic resonance imaging.


Asunto(s)
Implantes Dentales , Procedimientos de Cirugía Plástica , Humanos , Satisfacción del Paciente , Titanio , Cráneo/diagnóstico por imagen , Cráneo/cirugía , Craneotomía/métodos , Prótesis e Implantes
2.
J Craniofac Surg ; 32(4): 1291-1296, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33710056

RESUMEN

BACKGROUND: Adequate and stable coverage of cranial contour and continuity defects of any origin is a common challenge in neurosurgical clinics. This study presents the results of investigations concerning the mechanical load-bearing capacity and design advantages of custom-made implants made from a thin, pure-titanium sheet (CranioTop) (CLinstruments, Attendorn, Germany) for covering complex cranial defects. METHODS: In 9 test series, the stability of three differently shaped and sized thin titanium sheet implants was tested using vertical, uniaxial compression with 3 different compression stamps, to investigate the behaviour of these implants in relation to punctiform as well as planar forces. RESULTS: All 9 model implants showed elastic behavior in the synchronously recorded force/displacement diagrams at an impression of up to 2 mm. The forces at 2 mm deformation were between 170.1 and 702.7 Newton. CONCLUSION: Cranioplasty using CranioTop is a stable procedure for covering skull defects, even those of large dimensions. An added advantage is the significant reduction in effort required to prepare the area of the bone margins compared to other current techniques of cranioplasty.


Asunto(s)
Implantes Dentales , Procedimientos de Cirugía Plástica , Alemania , Humanos , Prótesis e Implantes , Cráneo/cirugía , Titanio , Soporte de Peso
3.
Acta Neurochir (Wien) ; 162(11): 2659-2669, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32495079

RESUMEN

BACKGROUND: A shift in how we evaluate healthcare outcomes has driven the introduction of quality indicators as potential parameters to evaluate value-based healthcare delivery. So far, only few studies have been performed evaluating quality indicators in the context of neurosurgery, especially in the European region. The purpose of this study was to evaluate the 30-day readmission rate, identify reasons for readmission regarding the various neurosurgical diagnoses, and discuss the usefulness of this rate as a potential quality indicator. METHODS: During a 6-year period, a total of 8878 hospitalized patients in our neurosurgical department were retrospectively analyzed and included in this study. Reasons for readmission were identified. Patients' diagnoses and baseline characteristics were obtained in order to identify possible risk factors for readmission. RESULTS: The 30-day readmission rate was 2.9%. The most common reason for unplanned readmissions were surgical site infections. The reasons for readmissions varied significantly between the different underlying neurosurgical diseases (p < 0.001). Multivariate logistic regression revealed hydrocephalus (OR, 4) and shorter length of stay during index admission (OR, 0.9) as risk factors for readmission. CONCLUSIONS: We provided an analysis of reasons for readmission for various neurosurgical diseases in a large patient spectrum in Germany. Although readmission rates are easy to track and an attractive tool for quality assessment, the rate alone cannot be seen as an adequate measure for quality in neurosurgery as it lacks a homogenous definition and depends on the underlying health care system. In addition, strategies for risk adjustment are required.


Asunto(s)
Procedimientos Neuroquirúrgicos/efectos adversos , Readmisión del Paciente/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Garantía de la Calidad de Atención de Salud , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Adulto Joven
4.
J Clin Med ; 13(3)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38337502

RESUMEN

(1) Background: In this study, epidemiological, clinical, therapeutical, and haemostaseological variables were investigated regarding their correlation with the recurrence of chronic subdural haematomas to assess the risk of recurrence more reliably in everyday clinical practice. (2) Methods: In our retrospective study, the electronic records of 90 patients who underwent surgery for a chronic subdural haematoma at our institute between 1 January 2017 and 31 May 2021 were analysed regarding previously defined variables. (3) Results: In the patient collective, 33.33% of the 90 patients experienced a recurrence requiring treatment. The occurrence of a recurrence was not statistically significantly related to age, gender, known alcohol abuse, a specific location, extension over one or both hemispheres, the surgical method, or anticoagulant medication. However, the recurrence was statistically significantly related to haematoma width (p = 0.000007), septation (p = 0.005), and the existence of a coagulation disorder not treated with medication (p = 0.04). (4) Conclusions: In our study, the width of the haematoma, septation, and coagulation disorders not treated with medication were documented as risk factors for the occurrence of a chronic subdural haematoma. Identifying of these risk factors could help in adapting individual therapeutic concepts for chronic subdural haematomas.

5.
Hum Brain Mapp ; 34(6): 1464-76, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22331645

RESUMEN

Ischemic small vessel disease (SVD) is a common finding on routine scans in older people, but cognitive sequelae vary considerably. To improve understanding of mechanisms underlying decline or preservation of cognitive function in this condition, we assessed cognition and cortical plasticity in 20 elderly subjects with severe SVD and 20 age-matched controls without SVD, as rated on conventional MRI. Cognitive status was determined with a neuropsychological test battery, cortical plasticity induced with a paired associative stimulation protocol. Microstructural white matter changes were further analyzed for fractional anisotrophy using diffusion tensor imaging. We found that cortical plasticity as well as memory functions were preserved in severe SVD, while executive functions showed trendwise or significant decreases. Within the SVD group, lower white matter integrity in parahippocampal regions and posterior parts of the corpus callosum was associated with larger cortical plasticity, an association not seen for prefrontal white matter tracts. Enhanced cortical plasticity in subjects with lower white matter integrity in memory-relevant areas might thus indicate a compensatory mechanism to counteract memory decline in severe SVD.


Asunto(s)
Isquemia Encefálica/patología , Corteza Cerebral/patología , Corteza Cerebral/fisiología , Cognición/fisiología , Plasticidad Neuronal/fisiología , Anciano , Anisotropía , Isquemia Encefálica/complicaciones , Isquemia Encefálica/fisiopatología , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Estimulación Magnética Transcraneal
6.
Brain Sci ; 13(12)2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38137098

RESUMEN

(1) Background: Infections in deep brain stimulation (DBS) hardware, while an undesired complication of DBS surgeries, can be effectively addressed. Minor infections are typically treated with wound revision and IV antibiotics. However, when visible hardware infection occurs, most centers opt for complete removal, leaving the patient in a preoperative state and necessitating post-removal care. To avoid the need for such care, a novel technique was developed. (2) Methods: The electrodes are placed at the exact same spot and then led to the contralateral side. new extensions and a new generator contralateral to the infection as well. Subsequently, the infected system is removed. This case series includes six patients. (3) Results: The average duration of DBS system implantation before the second surgery was 272 days. Only one system had to be removed after 18 months due to reoccurring infection; the others remained unaffected. Laboratory alterations and pathogens were identified in only half of the patients. (4) Conclusions: The described surgical technique proves to be safe, well tolerated, and serves as a viable alternative to complete system removal. Importantly, it effectively prevents the need of post-removal care for patients.

8.
World Neurosurg ; 105: 585-590, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28602930

RESUMEN

BACKGROUND: Sufficient visualization of the operating field is crucial for success in surgery and is important especially concerning minimally invasive and deep approaches in spine surgery. METHODS: The spinal microsurgical approach was imitated using an isolated box that was accessed with different devices. Different light sources and auxiliary devices were analyzed and compared. Light sources used were a microscope, a standard operating room lamp, and a headlamp. The auxiliary devices included different tubes with and without optical light fibers, different retractors, and an endoscope. RESULTS: We demonstrated that different combinations of light sources and auxiliary devices provide significantly different illumination in the artificial operating field. A tube with optical fibers seems to be superior for nonmicroscopic approaches. The smaller these tubes are in diameter, the higher the illuminance on the surgical focus. CONCLUSIONS: The combination of tube and microscope seems to be the best choice for deep approaches in microsurgical spinal surgery. An endoscope supplies illuminance comparable to a surgical microscope.


Asunto(s)
Iluminación/métodos , Microcirugia/métodos , Procedimientos Neuroquirúrgicos/métodos , Equipo Quirúrgico , Humanos , Iluminación/instrumentación , Microcirugia/instrumentación , Modelos Neurológicos , Procedimientos Neuroquirúrgicos/instrumentación , Enfermedades de la Columna Vertebral/cirugía
9.
PLoS One ; 7(7): e41004, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22844423

RESUMEN

BACKGROUND: Severe stenosis of the internal carotid artery (ICA) has been associated with impaired cognition in patients, but its effect on rapid-onset cortical plasticity is not known. Carotid endarterectomy (CEA) in patients with severe ICA stenosis reduces stroke risk, but the impact on cognition or physiology of the respective hemisphere remains controversial. METHODS/RESULTS: 16 patients with severe stenosis of the ICA and 16 age and sex matched controls were included. Rapid-onset cortical plasticity was assessed using the paired-associative stimulation (PAS) protocol. PAS models long-term synaptic potentiation in human motor cortex, combining repetitive stimulation of the peripheral ulnar nerve with transcranial magnetic stimulation of the contralateral motor cortex. Cognitive status was assessed with a neuropsychological test battery. In patients, verbal learning and rapid-onset cortical plasticity were significantly reduced as compared to controls. Identical follow-up tests in 9 of the 16 patients six months after CEA revealed no improvement of cognitive parameters or cortical plasticity. CONCLUSIONS: Decreased rapid-onset cortical plasticity in patients with severe stenosis of the ICA was not improved by reperfusion. Thus, other strategies known to increase plasticity should be tested for their potential to improve cortical plasticity and subsequently cognition in these patients.


Asunto(s)
Estenosis Carotídea/fisiopatología , Estenosis Carotídea/cirugía , Corteza Cerebral/fisiopatología , Plasticidad Neuronal , Reperfusión , Anciano , Estenosis Carotídea/terapia , Estudios de Casos y Controles , Cognición , Terapia por Estimulación Eléctrica , Endarterectomía Carotidea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Estimulación Magnética Transcraneal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA