Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 149(6): e296-e311, 2024 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-38193315

RESUMEN

Multiple applications for machine learning and artificial intelligence (AI) in cardiovascular imaging are being proposed and developed. However, the processes involved in implementing AI in cardiovascular imaging are highly diverse, varying by imaging modality, patient subtype, features to be extracted and analyzed, and clinical application. This article establishes a framework that defines value from an organizational perspective, followed by value chain analysis to identify the activities in which AI might produce the greatest incremental value creation. The various perspectives that should be considered are highlighted, including clinicians, imagers, hospitals, patients, and payers. Integrating the perspectives of all health care stakeholders is critical for creating value and ensuring the successful deployment of AI tools in a real-world setting. Different AI tools are summarized, along with the unique aspects of AI applications to various cardiac imaging modalities, including cardiac computed tomography, magnetic resonance imaging, and positron emission tomography. AI is applicable and has the potential to add value to cardiovascular imaging at every step along the patient journey, from selecting the more appropriate test to optimizing image acquisition and analysis, interpreting the results for classification and diagnosis, and predicting the risk for major adverse cardiac events.


Asunto(s)
American Heart Association , Inteligencia Artificial , Humanos , Aprendizaje Automático , Corazón , Imagen por Resonancia Magnética
2.
Front Cardiovasc Med ; 11: 1297304, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38464845

RESUMEN

Introduction: Volume overload from mitral regurgitation can result in left ventricular systolic dysfunction. To prevent this, it is essential to operate before irreversible dysfunction occurs, but the optimal timing of intervention remains unclear. Current echocardiographic guidelines are based on 2D linear measurement thresholds only. We compared volumetric CT-based and 2D echocardiographic indices of LV size and function as predictors of post-operative systolic dysfunction following mitral repair. Methods: We retrospectively identified patients with primary mitral valve regurgitation who underwent repair between 2005 and 2021. Several indices of LV size and function measured on preoperative cardiac CT were compared with 2D echocardiography in predicting post-operative LV systolic dysfunction (LVEFecho <50%). Area under the curve (AUC) was the primary metric of predictive performance. Results: A total of 243 patients were included (mean age 57 ± 12 years; 65 females). The most effective CT-based predictors of post-operative LV systolic dysfunction were ejection fraction [LVEFCT; AUC 0.84 (95% CI: 0.77-0.92)] and LV end systolic volume indexed to body surface area [LVESViCT; AUC 0.88 (0.82-0.95)]. The best echocardiographic predictors were LVEFecho [AUC 0.70 (0.58-0.82)] and LVESDecho [AUC 0.79 (0.70-0.89)]. LVEFCT was a significantly better predictor of post-operative LV systolic dysfunction than LVEFecho (p = 0.02) and LVESViCT was a significantly better predictor than LVESDecho (p = 0.03). Ejection fraction measured by CT demonstrated significantly greater reproducibility than echocardiography. Discussion: CT-based volumetric measurements may be superior to established 2D echocardiographic parameters for predicting LV systolic dysfunction following mitral valve repair. Validation with prospective study is warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA