RESUMEN
Dynamic preload parameters are used to guide perioperative fluid management. However, reported cut-off values vary and the presence of a gray zone complicates clinical decision making. Measurement error, intrinsic to the calculation of pulse pressure variation (PPV) has not been studied but could contribute to this level of uncertainty. The purpose of this study was to quantify and compare measurement errors associated with PPV calculations. Hemodynamic data of patients undergoing liver transplantation were extracted from the open-access VitalDatabase. Three algorithms were applied to calculate PPV based on 1 min observation periods. For each method, different durations of sampling periods were assessed. Best Linear Unbiased Prediction was determined as the reference PPV-value for each observation period. A Bayesian model was used to determine bias and precision of each method and to simulate the uncertainty of measured PPV-values. All methods were associated with measurement error. The range of differential and proportional bias were [- 0.04%, 1.64%] and [0.92%, 1.17%] respectively. Heteroscedasticity influenced by sampling period was detected in all methods. This resulted in a predicted range of reference PPV-values for a measured PPV of 12% of [10.2%, 13.9%] and [10.3%, 15.1%] for two selected methods. The predicted range in reference PPV-value changes for a measured absolute change of 1% was [- 1.3%, 3.3%] and [- 1.9%, 4%] for these two methods. We showed that all methods that calculate PPV come with varying degrees of uncertainty. Accounting for bias and precision may have important implications for the interpretation of measured PPV-values or PPV-changes.
Asunto(s)
Fluidoterapia , Hemodinámica , Humanos , Presión Sanguínea , Teorema de Bayes , Fluidoterapia/métodos , Algoritmos , Volumen SistólicoRESUMEN
Pediatric cardiac anesthesia is a subspecialty of cardiac and pediatric anesthesiology dedicated to the perioperative care of patients with congenital heart disease. Members of the Congenital and Education Subcommittees of the European Association of Cardiothoracic Anaesthesiology and Intensive Care (EACTAIC) agreed on the necessity to develop an EACTAIC pediatric cardiac anesthesia fellowship curriculum. This manuscript represents a consensus on the composition and the design of the EACTAIC Pediatric Cardiac Anesthesia Fellowship program. This curriculum provides a basis for the training of future pediatric cardiac anesthesiologists by clearly defining the theoretical and practical requirements for fellows and host centers.
Asunto(s)
Anestesia en Procedimientos Quirúrgicos Cardíacos , Anestesiología , Anestesiología/educación , Niño , Cuidados Críticos , Curriculum , Becas , HumanosRESUMEN
BACKGROUND: Traditional formulas to calculate pulse pressure variation (PPV) cannot be used in patients with atrial fibrillation (AF). We have developed a new algorithm that accounts for arrhythmia-induced pulse pressure changes, allowing us to isolate and quantify ventilation-induced pulse pressure variation (VPPV). The robustness of the algorithm was tested in patients subjected to altered loading conditions. We investigated whether changes in VPPV imposed by passive leg raising (PLR) were proportional to the pre-PLR values. METHODS: Consenting patients with active AF scheduled for an ablation of the pulmonary vein under general anaesthesia and mechanical ventilation were included. Loading conditions were altered by PLR. ECG and invasive pressure data were acquired during 60 s periods before and after PLR. A generalised additive model was constructed for each patient on each observation period. The impact of AF was modelled on the two preceding RR intervals of each beat (RR0 and RR-1). The impact of ventilation and the long-term pulse pressure trends were modelled as separate splines. Ventilation-induced pulse pressure variation was defined as the percentage of the maximal change in pulse pressure during the ventilation cycle. RESULTS: Nine patients were studied. The predictive abilities of the models had a median r2 of 0.92 (inter-quartile range: 89.2-94.2). Pre-PLR VPPV ranged from 0.1% to 27.9%. After PLR, VPPV decreased to 0-11.3% (P<0.014). The relation between the Pre-PLR values and the magnitude of the changes imposed by the PLR was statistically significant (P<0.001). CONCLUSIONS: Our algorithm enables quantification of VPPV in patients with AF with the ability to detect changing loading conditions.
Asunto(s)
Fibrilación Atrial/fisiopatología , Electrocardiografía/métodos , Corazón/fisiopatología , Pulmón/fisiopatología , Anciano , Algoritmos , Fibrilación Atrial/terapia , Presión Sanguínea/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración Artificial/métodosRESUMEN
BACKGROUND: Assessing diastolic dysfunction is essential and should be part of every routine echocardiography examination. However, clinicians routinely observe lower mitral annular velocities by transesophageal echocardiography (TEE) under anesthesia than described by awake transthoracic echocardiography (TTE). It would be important to know whether this difference persists under constant loading conditions. We hypothesized that mean early diastolic mitral annular velocity, measured by tissue Doppler imaging (TDI, JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic1/v/2021-04-15T211206Z/r/image-tiff) would be different in the midesophageal 4-chamber (ME 4Ch) than in the apical 4-chamber (AP 4Ch) view under unchanged or constant loading conditions. Secondarily we examined (1) JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic2/v/2021-04-15T211206Z/r/image-tiff in an alternative transesophageal view with presumed superior Doppler beam alignment, the deep transgastric view (DTG), compared to those in the AP 4Ch, and (2) early diastolic speckle tracking-based strain rate (JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic3/v/2021-04-15T211206Z/r/image-tiff), in the ME 4Ch and in the AP 4Ch. METHODS: Twenty-five consecutive adult patients undergoing on-pump cardiac surgery from February 2017 to July 2017 were included. Both TTE and TEE measurements were obtained under anesthesia in a randomized order in the AP 4Ch, ME 4Ch, and DTG views. Within-patient average values were compared by paired t tests with a Bonferroni adjustment. Box plots, correlation, and agreement by Bland-Altman were examined for all 3 comparisons. A second echocardiographer independently acquired and analyzed images; images were reanalyzed after 4 weeks. Image quality and reproducibility were also reported. RESULTS: Averaged JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic4/v/2021-04-15T211206Z/r/image-tiff measurements were lower in the ME 4Ch than in the AP 4Ch (6.6 ± 1.7 cm/s vs 7.0 ± 1.5 cm, P = .028; within-patient difference mean ± standard deviation: 0.6 ± 1.2 cm/s). An alternative TEE view for JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic5/v/2021-04-15T211206Z/r/image-tiff, the DTG, also exhibited lower mean values (6.0 ± 1.6 cm/s, P = .006; within-patient difference mean ± standard deviation: 1.1 ± 1.8 cm/s). JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic6/v/2021-04-15T211206Z/r/image-tiff strain rate showed a low degree of bias, but greater variability (ME 4Ch: 0.87 ± 0.32%/s vs AP 4Ch: 0.73 ± 0.18%/s, P = .078; within-patient difference mean ± standard deviation: -0.1 ± 0.2%/s). CONCLUSIONS: This study confirms that TEE modestly underestimates JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic7/v/2021-04-15T211206Z/r/image-tiff but not to a clinically relevant extent. While JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic8/v/2021-04-15T211206Z/r/image-tiff in the DTG is not a promising alternative, the future role for speckle tracking-based early diastolic strain rate is unknown.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Ecocardiografía Doppler , Ecocardiografía Transesofágica , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Bélgica , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/fisiopatologíaRESUMEN
BACKGROUND: Blockade of cardiac sympathetic fibers by thoracic epidural anesthesia (TEA) was previously shown to reduce right and left ventricular systolic function and effective pulmonary arterial elastance. At conditions of constant paced heart rate, cardiac output and systemic hemodynamics were unchanged. In this study, we further investigated the effect of cardiac sympathicolysis during physical stress and increased oxygen demand. METHODS: In a cross-over design, 12 patients scheduled to undergo thoracic surgery performed dynamic ergometric exercise tests with and without TEA. Hemodynamics were monitored and biventricular function was measured by transthoracic two-dimensional and M-mode echocardiography, pulsed wave Doppler and tissue Doppler imaging. RESULTS: TEA attenuated systolic RV function (TV S': - 21%, P < 0.001) and LV function (MV S': - 14%, P = 0.025), but biventricular diastolic function was not affected. HR (- 11%, P < 0.001), SVI (- 15%, P = 0.006), CI (- 21%, P < 0.001) and MAP (- 12%, P < 0.001) were decreased during TEA, but SVR was not affected. Exercise resulted in significant augmentation of systolic and diastolic biventricular function. During exercise HR, SVI, CI and MAP increased (respectively, + 86%, + 19%, + 124% and + 17%, all P < 0.001), whereas SVR decreased (- 49%, P < 0.001). No significant interactions between exercise and TEA were found, except for RPP (P = 0.024) and MV E DT (P = 0.035). CONCLUSION: Cardiac sympathetic blockade by TEA reduced LV and RV systolic function but did not significantly blunt exercise-induced increases in LV and RV function. These data indicate that additional mechanisms besides those controlled by the cardiac sympathetic nervous system are involved in the regulation of cardiac function during dynamic exercise. Trial registration Clinical trial registration: Nederlands Trial Register, NTR 4880 http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=4880 .
Asunto(s)
Anestesia Epidural , Bloqueo Nervioso Autónomo/métodos , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología , Adolescente , Adulto , Anciano , Estudios Cruzados , Ecocardiografía Doppler , Prueba de Esfuerzo , Femenino , Sistema de Conducción Cardíaco/fisiología , Monitorización Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Sistema Nervioso Simpático/fisiologíaRESUMEN
The European Association of Cardiothoracic Anaesthesiology (EACTA) and the Society of Cardiovascular Anesthesiologists (SCA) aimed to create joint recommendations for the perioperative management of patients with suspected or proven severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection undergoing cardiac surgery or invasive cardiac procedures. To produce appropriate recommendations, the authors combined the evidence from the literature review, reevaluating the clinical experience of routine cardiac surgery in similar cases during the Middle East Respiratory Syndrome (MERS-CoV) outbreak and the current pandemic with suspected coronavirus disease 2019 (COVID-19) patients, and the expert opinions through broad discussions within the EACTA and SCA. The authors took into consideration the balance between established procedures and the feasibility during the present outbreak. The authors present an agreement between the European and US practices in managing patients during the COVID-19 pandemic. The recommendations take into consideration a broad spectrum of issues, with a focus on preoperative testing, safety concerns, overall approaches to general and specific aspects of preparation for anesthesia, airway management, transesophageal echocardiography, perioperative ventilation, coagulation, hemodynamic control, and postoperative care. As the COVID-19 pandemic is spreading, it will continue to present a challenge for the worldwide anesthesiology community. To allow these recommendations to be updated as long as possible, the authors provided weblinks to international public and academic sources providing timely updated data. This document should be the basis of future task forces to develop a more comprehensive consensus considering new evidence uncovered during the COVID-19 pandemic.
Asunto(s)
Anestesia en Procedimientos Quirúrgicos Cardíacos , Anestesiología , COVID-19 , Anestesiólogos , China , Consenso , Humanos , Pandemias , SARS-CoV-2RESUMEN
OBJECTIVES: Transcatheter aortic valve replacement (TAVR) has become an alternative treatment for patients with symptomatic aortic stenosis not eligible for surgical valve replacement due to a high periprocedural risk or comorbidities. However, there are several areas of debate concerning the pre-, intra- and post-procedural management. The standards and management for these topics may vary widely among different institutions and countries in Europe. DESIGN: Structured web-based, anonymized, voluntary survey. SETTING: Distribution of the survey via email among members of the European Association of Cardiothoracic Anaesthesiology working in European centers performing TAVR between September and December 2018. PARTICIPANTS: Physicians. MEASUREMENTS AND MAIN RESULTS: The survey consisted of 25 questions, including inquiries regarding number of TAVR procedures, technical aspects of TAVR, medical specialities present, preoperative evaluation of TAVR candidates, anesthesia regimen, as well as postoperative management. Seventy members participated in the survey. Reporting members mostly performed 151-to-300 TAVR procedures per year. In 90% of the responses, a cardiologist, cardiac surgeon, cardiothoracic anesthesiologist, and perfusionist always were available. Sixty-six percent of the members had a national curriculum for cardiothoracic anesthesia. Among 60% of responders, the decision for TAVR was made preoperatively by an interdisciplinary heart team with a cardiothoracic anesthesiologist, yet in 5 countries an anesthesiologist was not part of the decision-making. General anesthesia was employed in 40% of the responses, monitored anesthesia care in 44%, local anesthesia in 23%, and in 49% all techniques were offered to the patients. In cases of general anesthesia, endotracheal intubation almost always was performed (91%). It was stated that norepinephrine was the vasopressor of choice (63% of centers). Transesophageal echocardiography guiding, whether performed by an anesthesiologist or cardiologist, was used only ≤30%. Postprocedurally, patients were transferred to an intensive care unit by 51.43% of the respondents with a reported nurse-to-patient ratio of 1:2 or 1:3, to a post-anesthesia care unit by 27.14%, to a postoperative recovery room by 11.43%, and to a peripheral ward by 10%. CONCLUSION: The results indicated that requirements and quality indicators (eg, periprocedural anesthetic management, involvement of the anesthesiologist in the heart team, etc) for TAVR procedures as published within the European guideline are largely, yet still not fully implemented in daily routine. In addition, anesthetic TAVR management also is performed heterogeneously throughout Europe.
Asunto(s)
Anestésicos , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anestesia General , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Europa (Continente) , Humanos , Factores de Riesgo , Encuestas y Cuestionarios , Resultado del TratamientoRESUMEN
The novel coronavirus pandemic has radically changed the landscape of normal surgical practice. Lifesaving cancer surgery, however, remains a clinical priority, and there is an increasing need to fully define the optimal oncologic management of patients with varying stages of lung cancer, allowing prioritization of which thoracic procedures should be performed in the current era. Healthcare providers and managers should not ignore the risk of a bimodal peak of mortality in patients with lung cancer; an imminent spike due to mortality from acute coronavirus disease 2019 (COVID-19) infection, and a secondary peak reflecting an excess of cancer-related mortality among patients whose treatments were deemed less urgent, delayed, or cancelled. The European Association of Cardiothoracic Anaesthesiology and Intensive Care Thoracic Anesthesia Subspecialty group has considered these challenges and developed an updated set of expert recommendations concerning the infectious period, timing of surgery, vaccination, preoperative screening and evaluation, airway management, and ventilation of thoracic surgical patients during the COVID-19 pandemic.
Asunto(s)
Anestesia , Anestesiología , COVID-19 , Cuidados Críticos , Humanos , Pandemias , SARS-CoV-2RESUMEN
BACKGROUND: Maintaining adequate perioperative hepatic blood flow (HBF) supply is essential for preservation of postoperative normal liver function. Propofol and sevoflurane affect arterial and portal HBF. Previous studies have suggested that propofol increases total HBF, primarily by increasing portal HBF, while sevoflurane has only minimal effect on total HBF. Primary objective was to compare the effect of propofol (group P) and sevoflurane (group S) on arterial, portal and total HBF and on the caval and portal vein pressure during major abdominal surgery. The study was performed in patients undergoing pancreaticoduodenectomy because - in contrast to hepatic surgical procedures - this is a standardized surgical procedure without potential anticipated severe hemodynamic disturbances, and it allows direct access to the hepatic blood vessels. METHODS: Patients were randomized according to the type of anesthetic drug used. For both groups, Bispectral Index (BIS) monitoring was used to monitor depth of anesthesia. All patients received goal-directed hemodynamic therapy (GDHT) guided by the transpulmonary thermodilution technique. Hemodynamic data were measured, recorded and guided by Pulsioflex™. Arterial, portal and total HBF were measured directly, using ultrasound transit time flow measurements (TTFM) and were related to hemodynamic variables. RESULTS: Eighteen patients were included. There was no significant difference between groups in arterial, portal and total HBF. As a result of the GDHT, pre-set hemodynamic targets were obtained in both groups, but MAP was significantly lower in group S (p = 0.01). In order to obtain these pre-set hemodynamic targets, group S necessitated a significantly higher need for vasopressor support (p < 0.01). CONCLUSION: Hepatic blood flow was similar under a propofol-based and a sevoflurane-based anesthetic regimen. Related to the application of GDHT, pre-set hemodynamic goals were maintained in both groups, but sevoflurane-anaesthetized patients had a significantly higher need for vasopressor support. TRIAL REGISTRATION: Study protocol number is AGO/2017/002 - EC/2017/0164. EudraCT number is 2017-000071-90. Clin.trail.gov, NCT03772106 , Registered 4/12/2018, retrospective registered.
Asunto(s)
Anestésicos por Inhalación/farmacología , Anestésicos Intravenosos/farmacología , Hígado/irrigación sanguínea , Propofol/farmacología , Flujo Sanguíneo Regional/efectos de los fármacos , Sevoflurano/farmacología , Femenino , Humanos , Hígado/efectos de los fármacos , Masculino , Persona de Mediana EdadRESUMEN
OBJECTIVE: First, to compare tricuspid annular displacement and velocity in transthoracic and transesophageal echocardiography (TTE, TEE) using conventional angle-dependent technologies. Second, to evaluate both alternative TEE views as well as an alternative technology (speckle tracking) for overcoming proposed differences in TTE and TEE. DESIGN: Prospective, comparative, cross-over study with a randomized order of image acquisition. SETTING: University hospital. PARTICIPANTS: Adults undergoing cardiac surgery. INTERVENTIONS: Postinduction standardized image acquisition and analysis in TTE and TEE by 2 echocardiographers. MEASUREMENTS AND MAIN RESULTS: The authors measured tricuspid annular plane systolic excursion (TAPSE) by M-mode and velocity by tissue Doppler (S') in the apical 4-chamber TTE view and midesophageal 4-chamber TEE view (AP4C, ME4C). They then examined (1) the same measurements in alternative TEE views with proposed better ultrasound angulation; and (2) speckle tracking-based endpoints (TAPSE by speckle tracking, strain, and strain rate). Data were available in 24 of 25 patients. Conventional TAPSE by M-mode and velocity by tissue Doppler (TDI) were underestimated in the ME4C compared with the AP4C reference (mean ± standard deviation: TAPSE: 13.1 ± 3.8 mm v 17.3 ± 4.0 mm; S': 6.7 ± 2.1 cm/s v 9.1 ± 2.2 cm/s; both p < 0.001). Neither a modified deep transgastric view (TAPSE 14.5 ± 4.7 mm, pâ¯=â¯0.017; S' 6.8 ± 1.8 cm/s, p < 0.001) nor a transgastric right ventricular inflow view (TAPSE 12.3 ± 4.0 mm, pâ¯=â¯0.001; S' 6.0 ± 1.3 cm/s, p < 0.001) was similar to the AP4C. Speckle tracking TAPSE was unbiased but with high variability (mean biasâ¯=â¯-0.3 mm, 95% limits of agreementâ¯=â¯-9.1 to 8.4); strain and strain rate were higher in TEE than for TTE (-17.7 ± 3.6 v -12.6 ± 2.1, p < 0.001; -1.0 ± 0.2/s v -0.7 ± 0.1/s, p < 0.001). CONCLUSIONS: Right ventricular displacement, velocity, and myocardial deformation measured by TEE versus TTE are different. Neither alternative transesophageal echocardiography views nor speckle tracking-based deformation is promising; TAPSE by speckle tracking is unbiased but imprecise.
Asunto(s)
Ecocardiografía , Disfunción Ventricular Derecha , Adulto , Estudios Cruzados , Ecocardiografía Transesofágica , Humanos , Estudios Prospectivos , Sístole , Función Ventricular DerechaRESUMEN
This special article summarizes the design and certification process of the European Association of Cardiothoracic Anesthesiology (EACTA) Cardiothoracic and Vascular Anesthesia (CTVA) Fellowship Program. The CTVA fellowship training includes a two-year curriculum at an EACTA-accredited educational facility. Before fellows are accepted into the program, they must meet a number of requirements, including evidence of a valid license to practice medicine, a specialist degree examination in anesthesiology, and appropriate language skills as required in the host centers. The CVTA Fellowship Program has 2 sequential and complementary levels of training-both with a modular structure that allows for individual planning and also takes into account the differing national healthcare needs and requirements of the 36 countries represented in EACTA. The basic training period focuses on the anesthetic management of patients undergoing cardiac, thoracic, and vascular surgery and related procedures. The advanced training period is intended to deepen and to extend the clinical and nontechnical skills that fellows have acquired during the basic training. The goal of the EACTA fellowship is to produce highly trained and competent perioperative physicians who are able to care for patients undergoing cardiac, thoracic, and vascular anesthesia.
Asunto(s)
Anestesia en Procedimientos Quirúrgicos Cardíacos , Anestesia , Anestesiología , Anestesiología/educación , Curriculum , Becas , HumanosRESUMEN
The novel coronavirus has caused a pandemic around the world. Management of patients with suspected or confirmed coronavirus infection who have to undergo thoracic surgery will be a challenge for the anesthesiologists. The thoracic subspecialty committee of European Association of Cardiothoracic Anaesthesiology (EACTA) has conducted a survey of opinion in order to create recommendations for the anesthetic approach to these challenging patients. It should be emphasized that both the management of the infected patient with COVID-19 and the self-protection of the anesthesia team constitute a complicated challenge. The text focuses therefore on both important topics.
Asunto(s)
Comités Consultivos/normas , Manejo de la Vía Aérea/normas , Anestesia en Procedimientos Quirúrgicos Cardíacos/normas , Betacoronavirus , Infecciones por Coronavirus/cirugía , Neumonía Viral/cirugía , Guías de Práctica Clínica como Asunto/normas , Manejo de la Vía Aérea/métodos , Anestesia en Procedimientos Quirúrgicos Cardíacos/métodos , Anestesiología/métodos , Anestesiología/normas , COVID-19 , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/epidemiología , Europa (Continente)/epidemiología , Humanos , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/epidemiología , SARS-CoV-2RESUMEN
OBJECTIVES: A rapid, reliable quantitative assessment of left ventricular systolic and diastolic function is important for patient treatment in urgent and dynamic settings. Quantification of annular velocities based on a single 2-dimensional image loop, rather than on Doppler velocities, could be useful in point-of-care or focused cardiac ultrasound. We hypothesized that novel speckle-tracking-based mitral annular velocities would correlate with reference standard tissue Doppler imaging (TDI) velocities in a focused cardiac ultrasound-esque setting. METHODS: Two echocardiographers each performed transthoracic echocardiographic measurements before and after induction of anesthesia in supine patients undergoing cardiac surgery. Speckle-tracking echocardiography (STE)-based systolic (S'STE ) and diastolic (E'STE and A'STE ) velocities were compared to TDI and global longitudinal strain/strain rate. We also compared mitral annular displacement by speckle tracking with M-mode imaging. RESULTS: Twenty-five patients were included and examined in both preinduction and postinduction states. Speckle-tracking-based velocities correlated with TDI measurements in both states (S', r = 0.73 and 0.76; E', r = 0.87 and 0.65; and A', r = 0.65 and 0.73), showing a mean bias of 25% to 30% of the reference standard measurement. The correlation of S'STE with strain and the strain rate (S-wave) and E'STE with the strain rate (E-wave) was good in awake, spontaneously breathing patients but was less strong in the ventilated state. Similarly, displacement by speckle tracking correlated with M-mode measurements in both states (r = 0.91 and 0.84). Measurements required medians of 31 and 34 seconds; reproducibility was acceptable for S'STE and E'STE . CONCLUSIONS: Speckle-tracking-based mitral annular velocities and displacement correlate well with conventional measures as well as with deformation imaging. They may be clinically useful in rapidly assessing both systolic and diastolic function from a single 2-dimensional image loop.
Asunto(s)
Ecocardiografía , Sistemas de Atención de Punto , Diástole , Humanos , Reproducibilidad de los Resultados , Sístole , Función Ventricular IzquierdaRESUMEN
Cardiac sympathetic blockade with high-thoracic epidural anesthesia is considered beneficial in patients undergoing major surgery because it offers protection in ischemic heart disease. Major outcome studies have failed to confirm such a benefit, however. In fact, there is growing concern about potential harm associated with the use of thoracic epidural anesthesia in high-risk patients, although underlying mechanisms have not been identified. Since the latest review on this subject, a number of clinical and experimental studies have provided new information on the complex interaction between thoracic epidural anesthesia-induced sympatholysis and cardiovascular control mechanisms. Perhaps these new insights may help identify conditions in which benefits of thoracic epidural anesthesia may not outweigh potential risks. For example, cardiac sympathectomy with high-thoracic epidural anesthesia decreases right ventricular function and attenuates its capacity to cope with increased right ventricular afterload. Although the clinical significance of this pathophysiologic interaction is unknown at present, it identifies a subgroup of patients with established or pending pulmonary hypertension for whom outcome studies are needed. Other new areas of interest include the impact of thoracic epidural anesthesia-induced sympatholysis on cardiovascular control in conditions associated with increased sympathetic tone, surgical stress, and hemodynamic disruption. It was considered appropriate to collect and analyze all recent scientific information on this subject to provide a comprehensive update on the cardiovascular effects of high-thoracic epidural anesthesia and cardiac sympathectomy in healthy and diseased patients.This review provides a comprehensive update on the cardiovascular effects of high-thoracic epidural anesthesia and cardiac sympathectomy in healthy and diseased patients.
Asunto(s)
Anestesia Epidural/tendencias , Bloqueo Nervioso Autónomo/tendencias , Barorreflejo/fisiología , Frecuencia Cardíaca/fisiología , Función Ventricular Izquierda/fisiología , Anestesia Epidural/métodos , Animales , Bloqueo Nervioso Autónomo/métodos , Barorreflejo/efectos de los fármacos , Enfermedades Cardiovasculares/tratamiento farmacológico , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/cirugía , Frecuencia Cardíaca/efectos de los fármacos , Hemodinámica/efectos de los fármacos , Hemodinámica/fisiología , Humanos , Vértebras Torácicas , Función Ventricular Izquierda/efectos de los fármacosRESUMEN
OBJECTIVES: A novel speckle-tracking-based option for measuring tricuspid annular velocities in the midesophageal 4-chamber view (ME4C) was compared with velocities measured by tissue Doppler in the apical-4 chamber view (AP4C). Because this method was based on a modified speckle-tracking-based measurement of tricuspid annular plane systolic excursion (TAPSE), the authors also compared TAPSE by speckle tracking in the ME4C with TAPSE by M-mode in the AP4C. The authors hypothesized that velocities measured by speckle tracking in transesophageal echocardiography (TEE) would be similar, correlate, and agree with those measured by tissue Doppler in transthoracic echocardiography (TTE). DESIGN: Prospective diagnostic study with randomization of the order of post-induction echocardiography views by TTE (AP4C) and TEE (ME4C). Images were both acquired and analyzed by 2 echocardiographers independently. The primary outcome was S'; secondary outcomes were E', A', and TAPSE. SETTING: Single university hospital. PARTICIPANTS: Consecutive adult patients undergoing cardiac surgery (mainly coronary artery bypass grafting). INTERVENTIONS: None. MAIN RESULTS: Complete data was available in 24 of 25 patients. For the primary outcome, S' measured by speckle tracking in the ME4C correlated and agreed with S' measured by tissue Doppler in the AP4C (S'STEâ¯=â¯0.87STDIâ¯+â¯0.60, p < 0.001, râ¯=â¯0.78; mean bias -0.6 cm/s, 95% limits of agreement (LoA) -3.5 to 2.4 cm/s). Similarly results were found for E', but not A' (E'STEâ¯=â¯0.69E'TDIâ¯+â¯2.37, p < 0.001, râ¯=â¯0.71; mean bias 0.1 cm/s, 95%LoA -2.5 to 2.8cm/s; A'STEâ¯=â¯0.15A'TDIâ¯+â¯11.17, pâ¯=â¯0.629). TAPSE measurements by the authors' modified speckle-tracking-based technique were similar to TAPSE by M-mode (18.2 ± 5.5 mm and 17.1 ± 3.9 mm, respectively). CONCLUSIONS: Tricuspid annular velocities (S'STE, E'STE) determined by speckle tracking in TEE seem to be promising surrogates for velocities measured in TTE. This may be important for perioperative assessment of the right ventricle.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Tricúspide/diagnóstico por imagen , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Ecocardiografía Doppler/métodos , Ecocardiografía Transesofágica/métodos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Reproducibilidad de los Resultados , Válvula Tricúspide/fisiopatología , Función Ventricular Derecha/fisiologíaRESUMEN
OBJECTIVES: In this measurement validation study, the authors evaluated agreement between 2-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), measuring anterior mitral valve leaflet length by both novice and experienced echocardiographers. DESIGN: This was a retrospective, observational study. SETTING: Single university hospital. PARTICIPANTS: Analyses on datasets from 44 patients. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Fifty datasets from 44 patients with mitral regurgitation were analyzed by 4 observers (2 novices, 2 experts). All observers measured the anterior mitral valve leaflet length from end-systolic 2D TEE images from the midesophageal longitudinal axis view and 3D software-augmented TEE images. The overall mean anterior mitral valve leaflet length was significantly shorter with 3D versus 2D TEE measurements (24.6 ± 4.5 mm v 26.2 ± 5.3 mm; p < 0.001), with novices measuring shorter leaflets than experts for both techniques (p < 0.001 and pâ¯=â¯0.005, respectively). Bland-Altman plots of 3D and 2D TEE measurements showed mean biases (95% limits of agreement) of -1.6 mm (-9.0 to 5.9 mm), -1.8 mm (-9.6 to 6.0 mm), and -1.3 mm (-8.4 to 5.7 mm) for all observers, novices, and experts, respectively. For 2D measurements, interobserver reliability was very strong among experts and strong among novices (Pearson's râ¯=â¯0.83 v 0.66; pâ¯=â¯0.055). For 3D measurements, interobserver reliability was strong in experts and moderate in novices (Pearson's râ¯=â¯0.69 v 0.51; pâ¯=â¯0.168). CONCLUSION: For both novices and experts, 3D TEE measurements of the anterior mitral valve leaflet were significantly shorter than 2D measurements. Interobserver reliability was lowest for novices making 3D TEE measurements, indicating that reliable, quantitative evaluation of 3D TEE may require a greater amount of practice.
Asunto(s)
Competencia Clínica/normas , Ecocardiografía Tridimensional/normas , Ecocardiografía/normas , Testimonio de Experto/normas , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Anciano , Ecocardiografía/métodos , Ecocardiografía Tridimensional/métodos , Testimonio de Experto/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios RetrospectivosRESUMEN
BACKGROUND: Blockade of cardiac sympathetic fibers by thoracic epidural anesthesia may affect right ventricular function and interfere with the coupling between right ventricular function and right ventricular afterload. Our main objectives were to study the effects of thoracic epidural anesthesia on right ventricular function and ventricular-pulmonary coupling. METHODS: In 10 patients scheduled for lung resection, right ventricular function and its response to increased afterload, induced by temporary, unilateral clamping of the pulmonary artery, was tested before and after induction of thoracic epidural anesthesia using combined pressure-conductance catheters. RESULTS: Thoracic epidural anesthesia resulted in a significant decrease in right ventricular contractility (ΔESV25: +25.5 mL, P=0.0003; ΔEes: -0.025 mm Hg/mL, P=0.04). Stroke work, dP/dtMAX, and ejection fraction showed a similar decrease in systolic function (all P<0.05). A concomitant decrease in effective arterial elastance (ΔEa: -0.094 mm Hg/mL, P=0.004) yielded unchanged ventricular-pulmonary coupling. Cardiac output, systemic vascular resistance, and mean arterial blood pressure were unchanged. Clamping of the pulmonary artery significantly increased afterload (ΔEa: +0.226 mm Hg/mL, P<0.001). In response, right ventricular contractility increased (ΔESV25: -26.6 mL, P=0.0002; ΔEes: +0.034 mm Hg/mL, P=0.008), but ventricular-pulmonary coupling decreased (Δ(Ees/Ea) = -0.153, P<0.0001). None of the measured indices showed significant interactive effects, indicating that the effects of increased afterload were the same before and after thoracic epidural anesthesia. CONCLUSIONS: Thoracic epidural anesthesia impairs right ventricular contractility but does not inhibit the native positive inotropic response of the right ventricle to increased afterload. Right ventricular-pulmonary arterial coupling was decreased with increased afterload but not affected by the induction of thoracic epidural anesthesia. CLINICAL TRIAL REGISTRATION: URL: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2844. Unique identifier: NTR2844.