Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Zhonghua Yi Xue Yi Chuan Xue Za Zhi ; 39(11): 1187-1191, 2022 Nov 10.
Artículo en Zh | MEDLINE | ID: mdl-36317201

RESUMEN

OBJECTIVE: To analyze the Z values of true and false positive cases by non-invasive prenatal testing (NIPT) in order to improve its accuracy in clinical practice. METHODS: Results of 24 384 NIPT tests were reviewed. For cases with high risks for trisomies 21, 18 and 13, the range of Z values in true and false positive cases was analyzed and discussed. RESULTS: A total of 335 high-risk cases were identified by NIPT, among which 256 had elected prenatal diagnosis, 153 (59.77%) were verified as true positives, and 103 (40.23%) were false positives, and the area under the curve (AUC) was 0.9994. For NIPT screening, the positive predictive value (PPV) for trisomy 21 was 100% when Z>13, regardless if the pregnant woman was over 35. When 335 and about 41.6% (5/12) for those<35. For trisomy 18, the PPV was 100% when Z>13, and only 14.3% (1/7) when 3

Asunto(s)
Trastornos de los Cromosomas , Síndrome de Down , Femenino , Embarazo , Humanos , Síndrome de la Trisomía 13/diagnóstico , Síndrome de la Trisomía 13/genética , Trisomía/diagnóstico , Trisomía/genética , Síndrome de Down/diagnóstico , Síndrome de Down/genética , Trastornos de los Cromosomas/genética , Síndrome de la Trisomía 18/diagnóstico , Diagnóstico Prenatal/métodos
2.
J Obstet Gynaecol Res ; 43(10): 1578-1584, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28708319

RESUMEN

AIM: The aim of the current study was to investigate whether iodized oil (IO) enhances high-intensity focused ultrasound (HIFU) ablation of uterine leiomyoma and to determine the features of hyperechoic changes in the target region. METHODS: Forty samples of uterine leiomyoma were randomly divided into an experimental group and a control group. In the experimental group, the leiomyoma was ablated by HIFU 30 min after 1 mL of iodized oil had been injected into the center of the myoma. The hyperechoic values and areas in the target region were observed by B-modal ultrasound after HIFU ablation. The samples were cut successively into slices and stained by triphenyltetrazolium chloride (TTC) solution within 1 h after HIFU ablation. The diameters of TTC-non-stained areas were measured and tissues in the borderline of the TTC-stained and -non-stained areas were observed pathologically. All procedures in the control group were the same as those in the experimental group except IO was replaced by physiological saline. RESULTS: The hyperechoic value in the target region in the experimental group was higher than that in the control group 4 min after HIFU ablation (P < 0.05). Hyperechoic areas in the target region as well as TTC-non-stained volumes in the experimental group were greater than those in the control group (P < 0.05). Routine pathologic observation showed that coagulation necrosis of leiomyoma occurred in the target region in both groups. CONCLUSION: IO causes coagulation necrosis, enlarges tissue damage, and postpones the attenuation of hyperechoic changes in the target region when HIFU ablation is carried out for leiomyoma in vitro.


Asunto(s)
Medios de Contraste/uso terapéutico , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Aceite Yodado/uso terapéutico , Leiomioma/terapia , Neoplasias Uterinas/terapia , Medios de Contraste/efectos adversos , Femenino , Humanos , Técnicas In Vitro , Aceite Yodado/efectos adversos
3.
Geburtshilfe Frauenheilkd ; 80(3): 300-306, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32139919

RESUMEN

Objective Aim of the study was to evaluate the clinical efficacy and safety of major uterine wall resection and reconstruction of the uterus (MURU) combined with a levonorgestrel-releasing intrauterine system (LNG-IUS) for the treatment of adenomyosis. Methods Ninety patients diagnosed with adenomyosis were enrolled in this study. All participants were examined by transvaginal ultrasound (TVU) or magnetic resonance imaging (MRI). Serum levels of cancer antigen 125 (CA 125) were quantitatively measured. All patients underwent MURU in combination with LNG-IUS. The therapeutic safety of MURU was assessed during surgery and the patients' stay in hospital. The clinical efficacy was evaluated by comparatively analyzing changes in dysmenorrhea, volume of menstrual blood, uterine volume and serum levels of CA 125 before, and at 3, 6 and 12 months following MURU. Results All 90 patients enrolled in the study were successfully treated with MURU combined with LNG-IUS. No significant complications were observed during surgery and hospital stay. The mean operation time, intraoperative blood loss and length of hospital stay were 82.4 ± 13.8 min, 53.3 ± 20.3 ml, and 4.3 ± 0.8 days, respectively. Dysmenorrhea completely disappeared in all patients. Uterine volume and serum levels of CA 125 were restored to normal ranges. No recurrence of adenomyosis was observed during postoperative follow-up. Conclusion MURU combined with LNG-IUS is an efficacious and safe treatment for severe adenomyosis. This combined technique is not only effective to manage severe adenomyosis but also preserves as much of the uterus as possible.

4.
Zhonghua Fu Chan Ke Za Zhi ; 42(1): 14-7, 2007 Jan.
Artículo en Zh | MEDLINE | ID: mdl-17331414

RESUMEN

OBJECTIVE: To explore the therapeutic effect of focused ultrasound (FU) on chronic cervicitis unitarily and its influential factors. METHODS: Three hundred and thirteen patients of chronic cervicitis were treated with the device of CZF model focused ultrasound. The therapeutic effects in 300 cases with complete records, as well as the relationship between the diameter of cervical erosion and the exposure time to FU were analyzed. RESULTS: The effective rates of FU in treatment of chronic cervicitis unitarily were 100.0% (53/53), 95.2% (120/126) and 91.7% (111/121), respectively, for mild, moderate and severe cases. The overall effective rate was 94.7% (284/300). With other parameters of FU unchanged, the exposure time to FU showed an exponential relationship with the diameter of erosion, and the regression equation was D = 31.71e(0.4808t) (R(2) = 0.9966). CONCLUSIONS: The controllability and achievement ratio of FU to treat cervical erosion could be enhanced when exposure time and manners were fully considered based on the diameter and type of cervical erosion. A satisfactory therapeutic efficacy could be achieved with FU to treat cervical erosion unitarily.


Asunto(s)
Terapia por Ultrasonido/métodos , Erosión del Cuello del Útero/terapia , Cervicitis Uterina/terapia , Adulto , Cuello del Útero/patología , Enfermedad Crónica , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Erosión del Cuello del Útero/patología , Cervicitis Uterina/patología
5.
Wei Sheng Yan Jiu ; 34(4): 474-6, 2005 Jul.
Artículo en Zh | MEDLINE | ID: mdl-16229282

RESUMEN

OBJECTIVE: To study the toxicity of nano-hydroxyapatite on rabbits by vein. METHODS: The hydroxyapatite solution was intravenous injected into 50 New Zealand white rabbits with different concentration, then to observe the reactions and the survial rates of rabbits, and to investigate the effects of nano-HA to the liver function, renal function, enzyme and Ca, Mg, P. RESULTS: The medium lethal dosege of nano-HA administrated intravenous (iv) was determined as 200mg/kg. The level of phosphorous increased but calcium and magnesium kept stable. LDH, CPK, GOP and GDT dramatically increased in 30 minutes after injection, arriving the peak at 2 hours later, however, they all returned to normal 24h after injection. BUN and ALP got to the peak at 24 hours later, then decreased rapidly to normal level. The other indexes almost maintained at normal level. CONCLUSION: Nano-hydroxyapatite has no accumulative toxicity to rabbits, it is suggested that it is safe when the hydroxyapatite-sol was applied intravenously as a drug carrier in small dosage more less than the medium lethal dose, even as a kind of anticancer drug.


Asunto(s)
Durapatita/toxicidad , Nanopartículas/toxicidad , Animales , Durapatita/administración & dosificación , Femenino , Inyecciones Intravenosas , Dosificación Letal Mediana , Masculino , Nanopartículas/administración & dosificación , Conejos , Pruebas de Toxicidad Aguda
6.
Oncol Rep ; 33(5): 2354-60, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25708247

RESUMEN

MicroRNAs (miRNAs) are frequently dysregulated in human cancers and can act as potent oncogenes or tumor suppressor genes. Aberrant expression of miR-424 has been identified in some types of cancer, however, its expression and potential biologic role in endometrial cancer are remains to be determined. In the present study, we demonstrated that miR-424 was downregulated in human endometrial cancer and suppressed growth of the human Ishikawa and HEC-1B endometrial cancer cell lines. Bioinformatics analysis indicated that E2F7 was a putative target of miR-424. In a luciferase reporter system, we confirmed that E2F7 was a direct target gene of miR-424. Furthermore, knockdown of E2F7 inhibited Ishikawa and HEC-1B cell growth. These findings indicate that miR-424 targets the E2F7 transcript and suppresses endometrial cancer cell growth, suggesting that miR-424 has a tumor suppressive role in human endometrial cancer pathogenesis.


Asunto(s)
Carcinoma/genética , Factor de Transcripción E2F7/genética , Neoplasias Endometriales/genética , Regulación Neoplásica de la Expresión Génica , MicroARNs/genética , ARN Mensajero/metabolismo , Apoptosis , Ciclo Celular , Línea Celular Tumoral , Proliferación Celular , Supervivencia Celular , Regulación hacia Abajo , Femenino , Técnicas de Silenciamiento del Gen , Humanos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
7.
Oncol Lett ; 7(5): 1485-1492, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24765161

RESUMEN

The aim of the present study was to evaluate the safety and efficiency of an intravenously delivered nano-hydroxyapatite (Nano-HA) solution into a rabbit model (Oryctolagus cuniculus) to determine the potential enhancement of high-intensity focused ultrasound (HIFU) for the ablation of hepatocellular carcinoma (HCC) in liver tissue. The present study clearly indicated that the intravenous delivery of large quantities of Nano-HA into the body of the rabbit model over relatively short periods of time may be absorbed by the hepatic reticuloendothelial system. Subsequent HIFU treatment for HCC, as well as intravenous Nano-HA, produced a rapid increase in temperature and an enlargement of the coagulated necrotic area during ablation in the in vivo and ex vivo environments. In addition, it was found that the therapeutic doses of Nano-HA produced mild and transient abnormalities in the normal renal function and hepatic enzymes during the first 24 h following administration. The results of the current study indicated that the combination of Nano-HA and HIFU may provide a safe and effective alternative to conventional surgical procedures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA