Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Nano Lett ; 24(13): 3978-3985, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38451178

RESUMEN

We investigated atomic site occupancy for the Si dopant in Si-doped κ-Ga2O3(001) using photoelectron spectroscopy (PES) and photoelectron holography (PEH). From PES and PEH, we found that the Si dopant had one chemical state, and three types of inequivalent Si substitutional sites (SiGa) were formed. The ratios for the inequivalent tetrahedral, pentahedral, and octahedral SiGa sites were estimated to be 55.0%, 28.1%, and 16.9%, respectively. Higher (lower) ratios for the three inequivalent SiGa sites may come from a lower (higher) formation energy. The Tetra (Octa) SiGa site has the highest (lowest) ratio of the three SiGa sites since it has the lowest (highest) formation energy. We suggest that the tetrahedral SiGa site is due to the active dopant site, whereas the pentahedral and octahedral SiGa sites can be attributed to the inactive dopant sites for Si-doped κ-Ga2O3(001).

2.
J Cardiothorac Vasc Anesth ; 38(8): 1777-1785, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38834445

RESUMEN

The cervical aortic arch (CAA) is an uncommon congenital anomaly in aortic development, characterized by an elongated aortic arch extending at or above the medial ends of the clavicles. Our objective was to examine the clinical and surgical characteristics of this infrequent condition in the adult population. PubMed, ScienceDirect, SciELO, DOAJ, and Cochrane Library databases were searched until December 2023 for case reports describing the presence of a cervical aortic arch in patients aged ≥18 years. Case reports and series were included if the following criteria were met: (1) description of the cervical aortic arch, (2) age ≥18 years, and (3) English language. The literature search identified 2,325 potentially eligible articles, 61 of whom met our inclusion criteria and included a combined number of 71 patients. Mean age was 38.6 ± 15.4 years, with a female prevalence of 67.1% (47/70). Two-thirds of the CAA were left-sided (48/71, 67.6%), and 62.0% (44/71) of patients presented a concomitant arch aneurysm. Asymptomatic patients were 45.7% (32/70), while of those that were symptomatic, 60.5% (23/38) had symptoms related to vascular-induced compression of trachea and esophagus. Surgery was performed in 42 patients (62.7%) among 67 cases that reported the patient's treatment, and 5 patients (11.9%) among those surgically treated underwent the procedure through an endovascular approach. CAA is an uncommon congenital abnormality that presents challenges in diagnosis and treatment due to its high anatomical variability, diverse clinical manifestations, and presence of concomitant diseases. Surgery seems to be a safe and effective option for the resolution of symptoms.


Asunto(s)
Aorta Torácica , Humanos , Aorta Torácica/anomalías , Aorta Torácica/cirugía , Aorta Torácica/diagnóstico por imagen , Adulto , Manejo de la Enfermedad , Femenino
3.
Perfusion ; : 2676591241241422, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38537032

RESUMEN

PURPOSE: To investigate the impact of direct aortic cannulation (DAC) versus femoral arterial cannulation (FAC) on clinical outcomes of surgery for acute type A aortic dissection. METHODS: PubMed/MEDLINE, Scopus, and Cochrane Central Register of Controlled Trials were searched until August 25, 2023, to conduct a meta-analysis. Primary endpoints of the study were operative mortality and postoperative stroke. Secondary endpoints were cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, temporary neurological dysfunction (TND), combined stroke and TND, re-exploration for bleeding, and need for renal replacement therapy. A random-effect model was used to estimate the pooled effect size, and a leave-one-out method was used for the primary endpoints for sensitivity analysis. RESULTS: 15 studies met our eligibility criteria, including a total of 7941 samples. Operative mortality was significantly lower in the DAC group with a pooled odds ratio (OR) of 0.72 [95% confidence interval (CI): 0.61-0.85)]. Incidence of postoperative stroke was also lower in the DAC group with a pooled OR of 0.79 (95% CI: 0.66-0.94). However, after excluding one study with the greatest weight, the difference became nonsignificant. DAC was also associated with a lower incidence of postoperative TND, and re-exploration for bleeding with a pooled OR of 0.52 (95% CI: 0.37-0.73), and 0.60 (95% CI: 0.47-0.77), respectively. CONCLUSIONS: This meta-analysis showed that patients who underwent ATAAD repair with DAC had a lower incidence of operative mortality, postoperative stroke, TND, and re-exploration for bleeding compared to those who underwent FAC.

4.
Ann Vasc Surg ; 81: 121-128, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34780952

RESUMEN

BACKGROUND: This study investigated the impact of aortic diameter on late aortic dilation of the residual dissected aorta after tear-oriented aortic replacement for acute DeBakey type I aortic dissection. METHODS: Of 133 patients who underwent aortic replacement for acute DeBakey type I/II aortic dissection between 2008 and 2019, 45 patients with a residual dissected aorta after surgery for acute DeBakey type I aortic dissection and who underwent computed tomography at predischarge and after 1 year were retrospectively assessed. The aortic diameter and false lumen area were measured at 3 levels: the maximal aortic site, seventh thoracic vertebra, and celiac axis. Multivariable Cox regression analysis was employed to identify the predictors of late aortic dilation, defined as an aortic growth rate of ≥5 mm/year or a maximal aortic diameter of ≥55 mm. RESULTS: During a median follow-up of 75 [range: 13-152] months, 6 patients (5 men; mean age: 57 ± 14 years) experienced aortic dilation. All 6 patients had the maximal aortic diameter between the distal aortic arch and seventh thoracic vertebra level at the last computed tomography. Multivariable Cox regression analysis showed that the predischarge maximal aortic diameter was an independent determinant of late aortic dilation (hazard ratio: 2.28/mm, 95% confidence interval: 1.10-5.86). CONCLUSIONS: Predischarge maximal aortic diameter is a significant predictor of late aortic dilation in patients with a residual dissected aorta after tear-oriented surgical repair of acute DeBakey type I aortic dissection.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/diagnóstico por imagen , Aorta/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Dilatación , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
5.
Kyobu Geka ; 75(13): 1094-1097, 2022 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-36539225

RESUMEN

A 57-year-old man was transferred with sudden onset chest pain and evolving paralysis and numbness in the left leg. Contrast computed tomography (CT) revealed Stanford type A acute aortic dissection from the ascending aorta to bilateral internal and external iliac arteries with blood flow obstruction to the left kidney and left lower limb. Surgery was initiated 10 hours after onset of ischemic symptoms in the leg. Femoro-femoral bypass was carried out first, and we ensured sufficient phlebotomy from the ischemic limb during reperfusion and continuous hemodiafiltration to prevent myonephropathic metabolic syndrome. Total aortic arch replacement was then performed. Our treatment strategy was effective in this case of Stanford type A aortic dissection with prolonged lower limb ischemia. Although left hip disarticulation was subsequently required due to intractable infection, the patient became able to walk with an artificial limb after post-rehabilitation.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Masculino , Humanos , Persona de Mediana Edad , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Isquemia/cirugía , Aorta Abdominal , Riñón , Procedimientos Quirúrgicos Vasculares/métodos , Síndrome , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía
6.
Ann Vasc Surg ; 73: 361-368, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33359705

RESUMEN

BACKGROUND: To investigate the effect of unilateral internal iliac artery (IIA) embolization for endovascular aortic repair (EVAR) on gluteal muscle size. METHODS: We assessed the gluteal muscle size in 111 consecutive patients who underwent elective EVAR with unilateral IIA embolization (n = 31) or without IIA embolization (n = 80) for abdominal aortic and/or iliac artery aneurysm. The cross-sectional area (CSA) of the gluteus maximus (Gmax) and gluteus medius/minimus (Gmed/min) was measured on computed tomography preoperatively, 6 months postoperatively, and final follow-up. Mean changes in the Gmax and Gmed/min CSA were evaluated using a mixed model analysis of variance. RESULTS: In the patients with embolization, both the Gmax and Gmed/min CSA significantly decreased over time on the embolization and nonembolization sides (P < 0.001); however, embolization did not affect the changes in the Gmax CSA (P = 0.64) and Gmed/min CSA (P = 0.99). In the patients with embolization and those without embolization, both the Gmax and Gmed/min CSA significantly decreased over time (P < 0.001); however, embolization did not affect the changes in the Gmax CSA (P = 0.76) and Gmed/min CSA (P = 0.11). CONCLUSIONS: Unilateral IIA embolization was not associated with gluteal muscle atrophy after EVAR. Pre-emptive unilateral IIA embolization for EVAR seems to be an acceptable procedure in terms of maintenance of gluteal muscle size.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Ilíaco/cirugía , Arteria Ilíaca/cirugía , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Nalgas , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Aneurisma Ilíaco/mortalidad , Arteria Ilíaca/diagnóstico por imagen , Masculino , Tomografía Computarizada Multidetector , Atrofia Muscular/diagnóstico por imagen , Atrofia Muscular/etiología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Ann Vasc Surg ; 70: 474-480, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32634557

RESUMEN

BACKGROUND: Aortic stent grafting can cause aortic stiffening and increase pulse wave velocity (PWV), which can potentially affect long-term cardiovascular outcomes. The aim of this study was to clarify the factors contributing to increases in PWV after thoracic endovascular aortic repair (TEVAR). METHODS: We included 64 patients with thoracic aortic pathology (51 men; mean age, 73 years) who underwent elective TEVAR, in this study. TEVAR was performed for degenerative aortic aneurysm (n = 43) or aortic dissection (n = 21), and the treatment length was 175 ± 52 mm. Brachial-ankle PWV (baPWV) was obtained before and 1 week after TEVAR. Univariable and multivariable logistic regression analyses were used to determine the predictors of increases in baPWV of ≥100 cm/sec after TEVAR. RESULTS: baPWV increased from 1,851 ± 392 cm/sec to 2,047 ± 479 cm/sec, and the change in baPWV (ΔbaPWV) was 195 ± 339 cm/sec (95% confidence interval, 111-280). Thirty-seven patients (58%) had ΔbaPWV ≥100 cm/sec after TEVAR. In the multivariable analysis, in addition to Δheart rate and Δsystolic blood pressure, age (odds ratio, 1.21/year; 95% confidence interval, 1.05-1.40) and coronary artery disease (odds ratio, 12.0; 95% confidence interval, 1.20-121) were independent determinants of ΔbaPWV ≥100 cm/sec after TEVAR, whereas ΔbaPWV ≥100 cm/sec was not associated with treatment length or device type. CONCLUSIONS: TEVAR was associated with PWV progression, especially in older patients with coronary artery disease, whereas treatment length or device type was not a predictor of PWV progression after TEVAR.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Rigidez Vascular , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis de la Onda del Pulso , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
8.
J Artif Organs ; 24(3): 368-371, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33392862

RESUMEN

We herein report a case of successful papillary muscle approximation for severe mitral regurgitation and HeartMate 3 left ventricular assist device implantation via left anterior thoracotomy in a 39-year-old man diagnosed with dilated cardiomyopathy. He underwent papillary muscle approximation in the mitral valve for severe functional regurgitation via the apical cuff hole. The postoperative course was uneventful. Echocardiography revealed that mitral regurgitation has disappeared. He was awaiting heart transplantation while working.


Asunto(s)
Insuficiencia de la Válvula Mitral , Músculos Papilares , Adulto , Ecocardiografía , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Músculos Papilares/diagnóstico por imagen , Músculos Papilares/cirugía , Toracotomía
9.
Ann Cardiothorac Surg ; 13(4): 346-353, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39157180

RESUMEN

The first robotic cardiac operation was performed more than two decades ago. This paper describes the distinct steps and components necessary for teaching robotic-assisted minimally invasive direct coronary artery bypass (R-MIDCAB). It also provides a general overview of the surgical robotic setup and ways to troubleshoot potential complications. The focus of robotic training is not only on the surgeon but includes an entire dedicated cardiac team and administrative institutional support. This team approach ensures that R-MIDCAB can be performed safely and reproducibly. Meticulous planning, incremental learning, and teamwork are the main factors leading to program success and optimal patient outcomes. Robotic-assisted internal mammary artery (IMA) harvesting and coronary revascularization via a small, anterior mini-thoracotomy has provided an alternative to sternotomy in selected patients with coronary artery disease (CAD). Benefits include less postoperative atrial fibrillation, fewer blood transfusion, less time in the operating room (OR), less ventilatory support, fewer strokes, decreased intensive care unit stay and shortened postoperative length of stay all of which manifests as a decrease in institutional resource utilization. Recent data show that R-MIDCAB and hybrid coronary revascularization provides good long-term outcomes. In addition to patient satisfaction, there is an additional overall cost benefit to R-MIDCAB over traditional sternotomy coronary artery bypass grafting (CABG), secondary to decreased hospital length of stay. Robotically harvesting the IMA, operating on a beating heart, and performing anastomoses through a small incision all require advanced training and incremental learning. Increased experience generally leads to shortened surgical times and fewer complications.

10.
J Cardiol Cases ; 30(1): 12-15, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007046

RESUMEN

We report a hybrid procedure of robotic-assisted coronary artery bypass grafting and transcatheter aortic valve-in-valve implantation for left main disease and prosthetic aortic valve stenosis. Robotic-assisted coronary artery bypass grafting using a left internal mammary artery graft was preferred to percutaneous coronary intervention because of the complex anatomy of the coronary lesion and concerns about dual antiplatelet therapy tolerance. This was followed by a valve-in-valve procedure five days later, allowing the patient to be discharged the next day. This innovative, less invasive approach demonstrates the feasibility and potential for early recovery in appropriately selected patients with complex coronary and aortic valve disease. Learning objective: Hybrid robotic-assisted coronary artery bypass grafting (CABG) and transcatheter aortic valve replacement (AVR) is a feasible and less invasive approach for appropriately selected patients with complex coronary and aortic valve disease who are not good candidates for percutaneous coronary intervention or conventional CABG and surgical AVR.

11.
Future Cardiol ; 20(5-6): 305-316, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38963122

RESUMEN

Aim: To evaluate the effects of double (axillary and femoral) vs. single (axillary) cannulation on early outcomes of acute type A aortic dissection (ATAAD). Materials & methods: Meta-analysis using PubMed/MEDLINE, Scopus, and Cochrane databases through August 23, 2023. Focused on operative mortality, postoperative stroke, re-exploration for bleeding, spinal cord injury, and renal replacement therapy. Results: Among 5 propensity score-matched studies with 2127 patients, double cannulation showed comparable mortality and higher rates of postoperative stroke (pooled odds ratio: 1.69, 95% confidence interval: 1.19-2.39) and need for renal replacement therapy (pooled odds ratio: 1.35, 95% confidence interval: 1.13-1.60) compared with single cannulation. Conclusion: Double arterial cannulation in ATAAD surgery is associated with increased postoperative stroke and renal replacement therapy than single cannulation.


What is this summary about? We studied the optimal way to maintain blood flow during surgery for acute aortic dissection. We focused on comparing the use of one tube placement site in the axillary artery with two sites, both in the axillary and femoral arteries, in five previous studies.What were the results? Using two sites was associated with a higher risk of stroke and need for dialysis after surgery than using only one site.What do the results mean? Adding a tube in the femoral artery for blood flow may increase the risk of complications. It appears that placing the tube only in the axillary artery may be a safer choice for appropriately selected patients having this surgery.


Asunto(s)
Disección Aórtica , Arteria Axilar , Humanos , Disección Aórtica/cirugía , Enfermedad Aguda , Cateterismo/métodos , Cateterismo Periférico/métodos , Arteria Femoral , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control
12.
Asian Cardiovasc Thorac Ann ; 32(4): 234-243, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38343086

RESUMEN

BACKGROUND: Research comparing the effectiveness of central aortic cannulation to axillary artery cannulation in repairing acute type A aortic dissection is limited and controversial. This meta-analysis aimed to compare early outcomes of central aortic cannulation versus axillary artery cannulation for surgery for acute aortic dissection type A. METHODS: A comprehensive systematic search was conducted across PubMed/MEDLINE, Scopus, and the Cochrane Central Register of Controlled Trials up to September 1, 2023. The primary endpoints were operative mortality and incidence of postoperative stroke. Secondary endpoints encompassed cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, postoperative temporary neurological dysfunction, combination of stroke and temporary neurological dysfunction, as well as the need for reexploration for bleeding, renal replacement therapy, and tracheotomy. A random-effect model was utilized to calculate the pooled effect size. RESULTS: Eleven studies met our eligibility criteria, enrolling a total of 7204 patients (2760 underwent aortic cannulation and 4444 underwent axillary cannulation). The operative mortality and incidence of postoperative stroke did not show statistical differences between the two groups, with a pooled odds ratio of 1.07 (95% confidence interval: 0.73-1.55) and 1.17 (0.95-1.42), respectively. Similarly, none of the secondary endpoints exhibited significant statistical differences between the two groups. CONCLUSIONS: Aortic cannulation can be a viable alternative to axillary artery cannulation for repair of acute aortic dissection type A, as both approaches present similar early clinical outcomes.


Asunto(s)
Aneurisma de la Aorta , Disección Aórtica , Arteria Axilar , Cateterismo Periférico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Aguda , Aorta/cirugía , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/diagnóstico por imagen , Disección Aórtica/cirugía , Disección Aórtica/mortalidad , Disección Aórtica/diagnóstico por imagen , Arteria Axilar/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Resultado del Tratamiento
13.
J Invasive Cardiol ; 36(6)2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38446024

RESUMEN

OBJECTIVES: The efficacy of hybrid robotic-assisted coronary artery bypass grafting (CABG) and transcatheter aortic valve replacement (TAVR) for coronary and aortic valve disease is poorly reported. Herein, we report our experience with this hybrid approach. METHODS: Between January 2018 and June 2022, 10 (7 male, 3 female) patients with a mean age of 81 years underwent the hybrid procedure. Coronary revascularization was performed prior to TAVR with robotic-assisted left internal mammary artery-to-left anterior descending (LAD) bypass grafting for left main or proximal LAD lesions with or without multivessel disease with or without hybrid percutaneous coronary intervention (PCI). RESULTS: Five patients had left main disease, and 5 had proximal LAD disease with or without multivessel disease. All patients tolerated the robotic-assisted CABG procedure well; 9 patients were extubated in the operating room and all patients were ambulatory on postoperative day 1. Five patients underwent hybrid PCI for non-LAD lesions. TAVR was subsequently performed at intervals ranging from 3 days to 5 months after CABG. One patient with end-stage renal disease on hemodialysis required hospitalization for heart failure during the interval period. The 1-year mortality rate was 0%, and 3 patients died during late follow-up (24-43 months). CONCLUSIONS: This innovative, less invasive approach demonstrates the potential for early recovery in appropriately selected patients with complex coronary and aortic valve disease with promising mid-term outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Procedimientos Quirúrgicos Robotizados , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estudios Retrospectivos , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria/efectos adversos , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Angiografía Coronaria/métodos , Estudios de Seguimiento
14.
Circ Cardiovasc Interv ; : e014296, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39258365

RESUMEN

BACKGROUND: The role of left atrial appendage occlusion (LAAO) in patients without previous atrial fibrillation (AF) is not established. This meta-analysis was conducted on patients with normal sinus rhythm who underwent cardiac surgery, with and without concomitant LAAO, to evaluate its effect on the incidence of cerebrovascular accidents (CVAs). METHODS: A systematic review was conducted from inception until December 2023 for randomized and propensity-score studies comparing CVA in patients without AF undergoing cardiac surgery with or without LAAO. RESULTS: Six studies met our inclusion criteria with a total of 4130 patients: 2146 in the LAAO group and 1984 in the no-LAAO group. The risk ratio of postoperative AF was 1.05 (95% CI, 0.86-1.28); P=0.628. The CVA rates at 5 years were 6.8±1.0% in the no-LAAO group and 4.3±0.8% in the LAAO group (log-rank P=0.021). The Cox regression analysis for CVA in patients undergoing LAAO reported a hazard ratio of 0.65 (95% CI, 0.45-0.94); P=0.022. Landmark analysis at 4 years highlighted a significant difference in overall survival between no-LAAO and LAAO groups, 86±12.2% versus 89.6±11.0%; P=0.041. CONCLUSIONS: In this meta-analysis of patients without previous AF undergoing cardiac surgery, LAAO was associated with a decreased risk of CVA, no difference in the incidence of postoperative atrial fibrillation, and a significant overall survival benefit at a 4-year landmark analysis. Although these findings support LAAO, the randomized LeAAPS trial (Left Atrial Appendage Exclusion for Prophylactic Stroke Reduction Trial), LAA-CLOSURE trial (A Randomized Prospective Multicenter Trial for Stroke Prevention by Prophylactic Surgical Closure of the Left Atrial Appendage in Patients Undergoing Bioprosthetic Aortic Valve Surgery), and LAACS-2 trial (Left Atrial Appendage Closure by Surgery-2) will help define the effectiveness of LAAO in patients undergoing cardiac surgery who have risk factors for AF and CVA. REGISTRATION: URL: https://www.crd.york.ac.uk/prospero/; Unique identifier: CRD42024496366.

15.
Heliyon ; 10(1): e23276, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38230229

RESUMEN

Cesium lead bromide (CsPbBr3) nanocrystals (NCs) with nanoplatelet shapes and different crystal structures were synthesized via the ligand-assisted reprecipitation (LARP) method using different pairs of ligands and antisolvents, namely oleic acid (OA) or linoleic acid (LA) as the ligand and toluene or chloroform as the antisolvent. The XRD data revealed that the obtained CsPbBr3 NCs have different crystal structures, namely orthorhombic, tetragonal, and cubic, depending on the ligand and antisolvent pair, which exhibited significantly different photoluminescence (PL) characteristics. From the XPS data, these CsPbBr3 nanoplatelets showed two doublet peaks of the Br-3d orbital at different binding energies, representing two different chemical environments of the Br bonds. The doublet peak apparent at a higher binding energy was associated with the Br chemical states at the crystal surface, which appeared because of the distorted crystal structure resulting from the interaction of the solvent and ligand with Br ions. The PL emission consists of three luminescence centers: a PL band peaked at 520 nm (A band), a PL band peaked at 540 nm (B band), and a PL band tail, which can be discussed in terms of exciton models. Stable and intense luminescence was observed in CsPbBr3 nanoplatelets synthesized using a pair of toluene antisolvent and LA ligand, namely CsPbBr3#(Tl/LA). The orthorhombic crystal structure and distorted crystal surface in this sample may lead to confinement of the photogenerated small exciton-polaron and weak phonon interactions, which effectively hinder exciton dissociation, particularly at the crystal surface, resulting in intense PL. The results of this study may provide additional important insights into the role of the antisolvent and ligand in the formation of CsPbBr3 NCs and the exciton behavior in their PL characteristics, which may also be found in other types of halide perovskites.

16.
J Clin Med ; 13(17)2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39274200

RESUMEN

Objective: We assessed the available literature regarding patients undergoing minimally invasive mitral valve surgery (MIMVS) with either transthoracic clamping (TTC) or endoaortic balloon occlusion (EABO). Methods: Original research studies that evaluated the perioperative outcomes of TTC versus EABO group were identified from 2000 to 2024. The incidence of all-cause mortality, cerebrovascular accidents (CVA), and aortic dissections were the primary endpoints. The cardiopulmonary bypass (CPB), cross-clamp, and ventilation time, along with the incidence of conversion to sternotomy, re-exploration, new-onset atrial fibrillation (AF), postoperative acute kidney injury (AKI), ICU stay, and LOS were the secondary endpoints. Subgroup analyses were performed regarding the EABO cannulation approach (femoral and aortic) and MIMVS approach (video-assisted and robotic-assisted). Sensitivity analyses were performed with the leave-one-out method and by including risk-adjusted populations. Results: Sixteen studies were included in both the qualitative and quantitative syntheses. After pooling data from 6335 patients, both groups demonstrated similar outcomes on all primary and secondary endpoints in the non-adjusted and adjusted total cohort analyses. These outcomes were further validated by the leave-one-out sensitivity analysis. In addition, the aortic cannulation EABO was associated with a lower cross-clamp time, followed by TTC and the femoral cannulation EABO approach. Furthermore, in the video-assisted subgroup analysis, the EABO approach was associated with a higher incidence of CVA, conversion to sternotomy, and longer ICU stay compared to the TTC group. Conclusions: The present meta-analysis indicates that both aortic occlusion techniques are safe and feasible in the context of MIMVS. A future well-designed randomized-control trial should further validate the current outcomes.

17.
Am J Cardiol ; 221: 9-18, 2024 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-38636627

RESUMEN

Patients with small aortic annuli (SAA) pose a challenge in patients undergoing aortic valve replacement because of the potential for prosthesis-patient mismatch (PPM). This study aimed to compare the clinical and hemodynamic outcomes of self-expandable valve (SEV) versus balloon-expandable valve (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance the baseline characteristics. Bioprosthesis valve dysfunction was based on modified Valve Academic Research Consortium 3 criteria. A total of 1,170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at computed tomography scan, and the matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p <0.001), higher grades of mitral regurgitation (p = 0.029), and lower ejection fraction (p <0.043) in BEVs than SEVs. At follow-up, significant differences favoring the SEV group regarding bioprosthesis valve dysfunction were observed (p = 0.002), especially in terms of severe PPM (p = 0.046) and at least moderate structural valve deterioration (p = 0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients, and PPM (including severe) than a SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the 2 groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Puntaje de Propensión , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Hemodinámica/fisiología , Estudios Retrospectivos , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Anciano , Ecocardiografía
18.
Artículo en Inglés | MEDLINE | ID: mdl-38719630

RESUMEN

BACKGROUND/PURPOSE: To evaluate the impact of coronary artery disease (CAD), percutaneous coronary intervention (PCI), and coronary lesion complexity on outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS/MATERIALS: This retrospective study included 1042 patients divided into two groups by the presence or absence of CAD (SYNTAX score 0, no history of revascularization). Propensity score matching was used to compare the two groups. The effect of PCI, SYNTAX score, and residual SYNTAX score was also analyzed. RESULTS: The median age of the cohort was 82 years, and 641 patients had CAD. After propensity score matching, 346 pairs were analyzed. During 5 years of follow-up (median: 25, range 0-72 months), the rate of coronary intervention was significantly higher in CAD patients (p = 0.018). However, all-cause mortality, composite of all-cause mortality, stroke, and coronary intervention, and overt bleeding defined by VARC-3 were comparable. After stratification, in patients with creatinine ≥1.5 mg/dl, CAD was associated with a worse composite outcome (p = 0.016). Neither PCI nor SYNTAX score was associated with all-cause mortality in CAD patients. Similarly, residual SYNTAX score showed no association with mortality in patients undergoing PCI (all p values >0.7). PCI did not reach a significant difference in overt bleeding in CAD patients (adjusted p = 0.06). CONCLUSIONS: Despite a higher incidence of coronary interventions, major clinical outcomes were similar between patients with and without CAD after TAVR. In patients with chronic kidney disease, CAD may be associated with an adverse composite outcome. Neither PCI nor SYNTAX/residual SYNTAX score influenced all-cause mortality.

19.
Coron Artery Dis ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38739467

RESUMEN

OBJECTIVE: To investigate the impact of prior coronary artery bypass grafting (CABG) and coronary lesion complexity on transcatheter aortic valve replacement (TAVR) outcomes for aortic stenosis. METHODS: Clinical outcomes of TAVR were retrospectively compared between patients with and without prior CABG, and between patients with prior CABG and without coronary artery disease (CAD). The impact of the CABG SYNTAX score was also evaluated in patients with prior CABG. RESULTS: The study included 1042 patients with a median age and follow-up of 82 years and 25 (range: 0-72) months, respectively. Of these, 175 patients had a history of CABG, while 401 were free of CAD. Patients with prior CABG were more likely to be male and had higher rates of diabetes, peripheral artery disease and atrial fibrillation compared with patients without prior CABG. After 2 : 1 propensity score matching, all-cause mortality (P = 0.17) and the composite of all-cause mortality, stroke and coronary intervention (P = 0.16) were similar between patients with (n = 166) and without (n = 304) prior CABG. A 1 : 1 propensity score-matched analysis, however, showed lower rates of all-cause mortality (P = 0.04) and the composite outcome (P = 0.04) in patients with prior CABG (n = 134) compared with patients without CAD (n = 134). The median CABG SYNTAX score was 16 (interquartile range: 9.0-23), which was not associated with better/worse clinical outcomes in patients with prior CABG. CONCLUSION: Prior CABG may positively affect mid-term TAVR outcomes for aortic stenosis compared with no CAD when adjusted for other comorbidities. The CABG SYNTAX score did not influence the prognosis after TAVR.

20.
J Invasive Cardiol ; 36(5)2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38422528

RESUMEN

OBJECTIVES: To assess the impact of concomitant mitral stenosis (MS) on early and late outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS: This study involved 952 patients undergoing TAVR for severe tricuspid aortic stenosis. The patients were classified into 3 groups: without MS, with progressive MS, and severe MS (mitral valve area ≤ 1.5 cm2). Clinical outcomes between these groups were compared. RESULTS: The median age of the overall cohort was 82 years, and patients in the progressive (n = 49) and severe (n = 24) MS groups were more likely to be female than those in the no-MS group (n = 879). Periprocedural mortality rate was lowest in the no-MS group (1.8%) compared with the progressive (4.1%) and severe (4.2%) MS groups, which were not significantly different (P = .20). During 5 years of follow-up (median: 27, range: 0-72 months), there was no significant difference in all-cause mortality (log-rank P = .99), a composite of all-cause mortality or rehospitalization for heart failure (log-rank P = .84), or cardiovascular death (log-rank P = .57) between groups. Although crude analysis showed a significant difference in rehospitalization for heart failure in the severe MS group compared with the no-MS group (P = .049), the difference was not significant in the multivariate analysis (adjusted hazard ratio: 1.36 [95% CI, 0.66-2.80], P = .41). CONCLUSIONS: TAVR can be safely performed in patients with severe tricuspid aortic stenosis and concomitant MS, with early and mid-term outcomes comparable to those in patients without MS.


Asunto(s)
Estenosis de la Válvula Aórtica , Estenosis de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico , Estenosis de la Válvula Mitral/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Anciano de 80 o más Años , Estudios Retrospectivos , Estudios de Seguimiento , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Anciano , Tasa de Supervivencia/tendencias , Factores de Tiempo , Factores de Riesgo , Complicaciones Posoperatorias/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA