Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 198-205, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037864

RESUMEN

INTRODUCTION: The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS: This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS: Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS: Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Femenino
2.
J Cardiovasc Electrophysiol ; 35(3): 505-510, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38178380

RESUMEN

INTRODUCTION: Dual atrioventricular nodal non-reentrant tachycardia (DAVNNT) is a rare and challenging-to-diagnose arrhythmia, without previous reports associating it with a leftward inferior extension (LIE). METHODS: Diagnosis was made using adenosine triphosphate (ATP) injection during atrial pacing in a suspected DAVNNT patient. RESULTS: Ablation of the rightward inferior extension was unsuccessful in eliminating DAVNNT; however, subsequent ablation of the LIE successfully eradicated the arrhythmia. CONCLUSION: This unique case, marked by the first instance of DAVNNT caused by LIE, diagnosed through ATP injection, underscores the utility of this diagnostic approach and broadens the spectrum of our understanding and management of this condition.


Asunto(s)
Ablación por Catéter , Polifosfatos , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Adenosina Trifosfato , Nodo Atrioventricular , Ablación por Catéter/efectos adversos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adenosina , Arritmias Cardíacas , Electrocardiografía
3.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38556747

RESUMEN

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Asunto(s)
Fibrilación Atrial , Criocirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Criocirugía/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Potenciales de Acción , Frecuencia Cardíaca , Factores de Tiempo , Estudios Retrospectivos , Recurrencia , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología
4.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
5.
J Cardiovasc Electrophysiol ; 34(2): 478-482, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36579408

RESUMEN

INTRODUCTION: Persistent left superior vena cava (PLSVC) is accompanied by enlarged coronary sinus (CS) and deformation of the triangle of Koch. This makes anatomical evaluation of the atrioventricular (AV) nodal pathways difficult. METHODS: We attempted cryoablation of retrograde fast pathway located in the enlarged CS roof of PLSVC for slow-fast AV nodal reentrant tachycardia (AVNRT) induced by inadvertent antegrade fast pathway elimination during ablation of left atrial tachycardia. RESULTS: Slow-fast AVNRT was successfully eliminated without AV block progression. CONCLUSIONS: This is the first case of successful retrograde fast pathway ablation of the CS ostial roof for slow-fast AVNRT with PLSVC.


Asunto(s)
Ablación por Catéter , Seno Coronario , Criocirugía , Vena Cava Superior Izquierda Persistente , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
6.
J Cardiovasc Electrophysiol ; 34(12): 2484-2492, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37752712

RESUMEN

INTRODUCTION: Cryoballoon ablation (CBA) of the left atrial (LA) roof in addition to a pulmonary vein isolation has been expected to improve the clinical outcomes post-atrial fibrillation (AF) ablation. We demonstrated the characteristics and efficacy of CBA of the LA roof through our experience with a large volume of procedures. METHODS: Among 1036 AF ablation procedures with CBA of the LA roof, 834 patients who underwent a de novo ablation were analyzed. RESULTS: Complete LA roof line conduction block was obtained in 767 patients (92.0%) solely by CBA (Group A). Compared with the other patients (Group B), the mean nadir balloon temperature during CBA of the LA roof (-44.5 ± 5.6°C for Group A vs. -40.5 ± 7.5°C for Group B, p < .01) and number of cryoballoon applications during the LA roof ablation with a circular mapping catheter located in the left superior pulmonary vein (1.3 ± 0.8 for Group A vs. 1.6 ± 1.0 for Group B, p = .02) were significantly lower in Group A. A multivariate analysis revealed that those were predictors of a complete LA roof conduction block after only CBA. The 1-year Kaplan-Meier atrial arrhythmia free rate estimates were 80.6% for Group A and 59.0% for Group B (p < .01). CONCLUSION: Complete LA roof line conduction block could be obtained with a cryoballoon without touch-up ablation in most cases. The LA roof CBA with a circular mapping catheter located in the right superior pulmonary vein was preferable to obtaining complete LA roof conduction block, which was important with regard to the clinical outcomes.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Criocirugía/efectos adversos , Criocirugía/métodos , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
7.
Europace ; 25(4): 1400-1407, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36892146

RESUMEN

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fallo Renal Crónico , Tromboembolia , Humanos , Femenino , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Anticoagulantes/efectos adversos , Hemorragia/inducido químicamente , Tromboembolia/etiología , Tromboembolia/prevención & control , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Ablación por Catéter/efectos adversos , Sistema de Registros
8.
Pacing Clin Electrophysiol ; 46(8): 882-889, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493225

RESUMEN

BACKGROUND: Open-window mapping (OWM) is a novel automated mapping method for catheter ablation of an accessory pathway (AP), in which the local signal is annotated with window-of-interest parameters to analyze both atrial and ventricular signals. This study aimed to determine the utility of OWM in visualizing the location and width of APs in patients with Wolff-Parkinson-White syndrome. METHODS: This two-center study enrolled 30 patients (20 males; mean age: 56 years, interquartile range [IQR]: 22-69 years) who underwent high-density OWM with the extended early-meets-late (EEML) algorithm using a 20-electrode, 5-spline catheter (PENTARAY, Biosense Webster). The lower threshold of the EEML was set to adjust the EEML gap to match the propagation mapping, and broad APs were defined as an EEML gap > 1 cm. RESULTS: The median mapping points, mapping time, and lower threshold of the EEML were 2482 (IQR: 1755-4000) points, 23 (IQR: 15-30) min, and 23 (IQR: 18-25), respectively. All 30 APs (24 in the mitral annulus and 6 in the tricuspid annulus) were successfully eliminated. Of these APs, 21 (70%) were eliminated by the first radio frequency (RF) application. OWM revealed broad APs in 11 patients (37%), in four of whom (36%) the first RF application achieved a loss of AP conduction (vs. 90% of patients without broad APs; p = .004). CONCLUSION: OWM facilitates the visualization of the location and width of APs, which may be particularly useful for predicting whether multiple RF applications are required for broad APs.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Síndrome de Wolff-Parkinson-White , Masculino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Síndrome de Wolff-Parkinson-White/cirugía , Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter/métodos , Ventrículos Cardíacos , Ondas de Radio , Electrocardiografía
9.
Pacing Clin Electrophysiol ; 46(6): 475-486, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37129189

RESUMEN

BACKGROUNDS: Catheter ablation for non-paroxysmal atrial fibrillation (non-PAF) remains challenging and more effective strategy has been required to reduce postoperative arrhythmia recurrences. This study aims to investigate the efficacy and safety of a novel extensive ablation strategy for non-PAF, that is based on a combination of cryoballoon (CBA), radiofrequency (RFA), and Marshall-vein ethanol ablations (EA-VOM). METHODS: The study was a single-center, retrospective observational study. We enrolled 171 consecutive patients who underwent de-novo catheter ablation for non-PAF under conscious sedation with a novel extensive ablation strategy that included CBA for pulmonary vein isolation (PVI) and left atrial roof ablation (LARA), RFA for mitral isthmus (MI) ablation, superior vena cava isolation, and other linear ablations and EA-VOM. Recurrence of atrial arrhythmias over 1 year, procedure outcomes, and procedure-related complications were investigated. RESULTS: A total of 139 (81.3%) patients remained in sinus rhythm during 1-year follow-up. Of the 139 patients, 51 patients (29.8%) received antiarrhythmic drugs. The mean procedure time was 204 ± 45 min. PVI and LARA ablation by CBA and MI block by RFA and EA-VOM were completed in 171 (100%) and 166 (97.1%) patients, respectively. No serious procedure-related complications were observed except for one case of delayed pericardial effusion. CONCLUSION: Approximately 80% of the study patients were AF-free during 1-year follow-up period after a single procedure based on the novel extensive ablation strategy combining CBA, RFA, and EA-VOM. This strategy for non-PAF may be preferred in terms of maintenance of sinus rhythm, safety even in high-risk patients, and relatively short procedure time.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Etanol , Vena Cava Superior , Atrios Cardíacos , Venas Pulmonares/cirugía , Criocirugía/métodos , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
10.
Pacing Clin Electrophysiol ; 45(1): 5-13, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34679229

RESUMEN

INTRODUCTION: Gastric hypomotility (GH) is a major complication of atrial fibrillation (AF) ablation. We aimed to clarify whether additional cryoballoon ablation (CBA) of the left atrial (LA) roof is associated with GH. METHODS AND RESULTS: This study included 54 patients with non-paroxysmal AF who underwent CBA for pulmonary vein isolation and of the LA roof line. GH was defined according to the results of esophagogastroscopy performed 2 days after ablation. GH was observed in 10 patients. There were significant differences in LA diameter (LAD), right inferior pulmonary vein (RIPV) diameter, and the height of the LA roof from the point where the LA posterior wall and esophagus make contact between patients with (GH+) and without GH (GH-) (LAD: 41.0 [36.3-41.8] mm vs. 46.5 [42.8-50.0] mm, p < .01; RIPV diameter: 19.7 [19.0-20.5] mm vs. 23.2 [21.2-24.9] mm, p < .01; height of LA roof: 5.7 [5.1-6.1] mm vs. 8.8 [7.1-11.2] mm for, p < .01, respectively). Multivariate analysis revealed that LA roof height was a predictor of GH. Moreover, Patient Assessment of Upper Gastrointestinal Disorders-Symptom Severity Index (PAGI-SYM) scores increased significantly 1 week after ablation (from 1.0 [0.0-2.8] to 5.0 [3.0-11.0], p = .03) in patients with GH. CONCLUSION: The height of the LA roof may be a predictor of GH after CBA of the LA roof line. Additionally, GH-related symptoms may still appear 1 week after ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Venas Pulmonares/cirugía , Estómago/fisiopatología , Anciano , Fibrilación Atrial/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos
11.
Int Heart J ; 63(6): 1085-1091, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36450547

RESUMEN

Pulmonary vein isolation (PVI) with a balloon-based visually guided laser ablation (VGLA) is regarded as a useful therapeutic tool for treating atrial fibrillation (AF). The clinical efficacy of a VGLA has never been fully investigated in patients with left common pulmonary vein (LCPV). We investigated the procedural safety as well as clinical usefulness of VGLA in patients with LCPV.This study consisted of 130 consecutive patients who underwent VGLA of de novo nonvalvular paroxysmal AF.Eleven patients (8.5%) had an LCPV (ostium maximal average diameter: 27.5 ± 4.9 mm, ostium minimal average diameter: 17.7 ± 3.5 mm). Nine out of 11 (81.8%) LCPVs were successfully occluded and isolated at the ostium with a VGLA-guided PVI. The ablation procedure time was significantly shorter in the patients with than without an LCPV (61.5 ± 15.4 versus 86.9 ± 32.9 minutes, P = 0.01). There was no difference regarding the atrial tachyarrhythmia recurrence between those with and without an LCPV (P = 0.18). A total of 15 patients underwent a redo procedure, but reconnections were not observed in any of the LCPV patients.The VGLA-guided PVI was a useful therapeutic tool even in patients with an LCPV. The presence of an LCPV might not be associated with an increased risk of any atrial tachyarrhythmia recurrence.


Asunto(s)
Fibrilación Atrial , Terapia por Láser , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Atrios Cardíacos , Fibrilación Atrial/cirugía , Rayos Láser
12.
J Cardiovasc Electrophysiol ; 32(7): 1803-1811, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33969567

RESUMEN

BACKGROUND: Contrast computed tomography (CT) is a useful tool for the detection of intracardiac thrombi. We aimed to assess the accuracy of the late-phase prone-position contrast CT (late-pCT) for thrombus detection in patients with persistent or long-standing persistent atrial fibrillation (AF). METHODS: Early and late-phase pCT were performed in 300 patients with persistent or long-standing AF. If late-pCT did not show an intracardiac contrast defect (CD), catheter ablation (CA) was performed. Immediately before CA, intracardiac echocardiography (ICE) from the left atrium was performed to confirm thrombus absence and the estimation of the blood velocity of the left atrial appendage (LAA). For patients with CDs on late-pCT, CA performance was delayed, and late-pCT was performed again after several months following oral anticoagulant alterations or dosage increases. RESULTS: Of the 40 patients who exhibited CDs in the early phase of pCT, six showed persistent CDs on late-pCT. In the remaining 294 patients without CDs on late-pCT, the absence of a thrombus was confirmed by ICE during CA. In all six patients with CD-positivity on late-pCT, the CDs vanished under the same CT conditions after subsequent anticoagulation therapy, and CA was successfully performed. Furthermore, the presence of residual contrast medium in the LAA on late-pCT suggested a decreased blood velocity in the LAA ( ≤ 15 cm/s) (sensitivity = 0.900 and specificity = 0.621). CONCLUSIONS: Late-pCT is a valuable tool for the assessment of intracardiac thrombi and LAA dysfunction in patients with persistent or long-standing persistent AF before CA.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ecocardiografía Transesofágica , Humanos , Posición Prona , Trombosis/diagnóstico por imagen , Trombosis/etiología , Tomografía Computarizada por Rayos X
13.
Circ J ; 85(3): 275-282, 2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33536386

RESUMEN

BACKGROUND: Pulmonary vein (PV) isolation (PVI) with balloon-based visually guided laser ablation (VGLA) is useful for treating atrial fibrillation (AF), but phrenic nerve injury (PNI) is an important complication. We investigated the predictors of developing PNI during VGLA.Methods and Results:We included 130 consecutive patients who underwent an initial VGLA of non-valvular paroxysmal AF. Twenty patients developed PNI during the PVI. The patients with PNI had a significantly larger right superior PV ostial area (RSPVOA) than the other patients (mean [±SD] 284.7±47.0 vs. 233.1±46.4 mm2, respectively; P<0.01). Receiver operating characteristic analyses revealed that the area under the RSPVOA curve was 0.79 (95% confidence interval [CI] 0.69-0.90) with an optimal cut-off point of 238.0 mm2(sensitivity, 0.58; specificity, 0.95). In multivariate analyses, a large RSPVOA (HR 1.02, 95% CI 1.01-1.03, P<0.01) and small balloon size (HR 0.70, 95% CI 0.50-0.99, P=0.04) were independent risk factors for PNI during VGLA. PNI remained in 13 patients after the procedure, but 12 of these patients recovered from the PNI during the follow-up period. CONCLUSIONS: The incidence of PNI during VGLA was relatively high, but PNI improved in most cases. A large RSPVOA and small balloon size were predictors of PNI during VGLA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Terapia por Láser , Traumatismos de los Nervios Periféricos , Nervio Frénico/lesiones , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Traumatismos de los Nervios Periféricos/etiología , Venas Pulmonares/cirugía , Resultado del Tratamiento
14.
Heart Vessels ; 36(5): 731-737, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33389066

RESUMEN

In patients with out-of-hospital cardiac arrest (OHCA), the probability of resuscitation is strongly influenced by the duration of cardiac arrest, which activates the blood coagulation-fibrinolysis system. Because plasma D-dimer levels reflect activity of blood coagulation and fibrinolysis, they should increase with the duration of cardiac arrest. We evaluated 222 consecutive non-traumatic witnessed OHCA patients who underwent measurement of plasma D-dimer levels on arrival in the emergency room. Return of spontaneous circulation was achieved in 138 patients (62%), but only 42 (19%) were alive 30 days post-OHCA. D-dimer levels were elevated in 217 patients (97.7%). There was a positive correlation between plasma D-dimer levels and duration of cardiac arrest in the 222 patients (r = 0.623, p < 0.001). When the cause of OHCA was limited to cardiovascular disease, the positive correlation between level of D-dimer and the duration of cardiac arrest (r = 0.776, p < 0.001) increased.D-dimer levels were significantly lower in survivors than in non-survivors [9.5 (1.4-17.5) vs 54.2 (34.2-74.3) µg/mL, p = 0.024]. Receiver operating characteristic curve analysis showed that a cutoff value of D-dimer ≤ 10 µg/L led to sensitivity (69.0%) and specificity (72.8%) for 30 day survival (area under curve 0.75). Multivariate logistic regression analysis showed that D-dimer ≤ 10 µg/ml was an independent predictor for 30 day survival (odds ratio 4.39, 95% confidence interval 1.41-13.70; p = 0.01). D-dimer level correlates with duration of cardiac arrest, especially in OHCA patients due to cardiovascular causes, and may help physicians assess the probability of survival in OHCA patients.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Servicios Médicos de Urgencia/estadística & datos numéricos , Productos de Degradación de Fibrina-Fibrinógeno/metabolismo , Paro Cardíaco Extrahospitalario/sangre , Sistema de Registros , Anciano , Biomarcadores/sangre , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Paro Cardíaco Extrahospitalario/terapia , Curva ROC , Estudios Retrospectivos , Factores de Tiempo
15.
Int Heart J ; 62(2): 298-304, 2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33731524

RESUMEN

Radiofrequency and cryoballoon applications around the pulmonary veins (PVs) could provoke a vagal reflex (VR) by modulating the intrinsic cardiac autonomic nervous system (ICANS).This study aimed to investigate the incidence, timing, and clinical impact of a VR provoked by a laser balloon application for a PV isolation (PVI).A total of 92 consecutive paroxysmal atrial fibrillation (PAF) patients underwent a laser balloon PVI of PAF. Acute changes in the heart rate and blood pressure were recorded. The heart rate variability (HRV) was tested by Holter ECGs before and at three months following the ablation. Three hundred forty-five out of 363 PVs were successfully isolated (97%) with laser balloon applications. A VR such as sinus bradycardia (26.1%), transient sinus arrest (9.8%), transient atrioventricular block (1.1%), or a blood pressure reduction (8.7%) was observed during the laser balloon applications for the PVI. The follow-up ended at 12 months. The HRV attenuation was comparable before and at three months after the ablation procedure between that with and without a VR (P = 0.14). The PAF recurrence rate was also comparable between the two groups (P = 0.882).The laser balloon PVI often provoked a VR, however, the modulation of the ICANS was temporary and for up to three months as measured by the HRV changes after the ablation, and the freedom from any atrial fibrillation recurrence was comparable regardless of the occurrence of a VR.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Frecuencia Cardíaca/fisiología , Terapia por Láser/métodos , Taquicardia Paroxística/cirugía , Nervio Vago/fisiopatología , Anciano , Fibrilación Atrial/fisiopatología , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Taquicardia Paroxística/fisiopatología , Factores de Tiempo
16.
Int Heart J ; 62(4): 771-778, 2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34276012

RESUMEN

Radiofrequency catheter ablation (RFCA) for pulmonary artery ventricular arrhythmia (PAVA) can be difficult because of the occasional existence of PAVA with preferential conduction.This study described the characteristics of PAVA that demonstrate preferential conduction.We analyzed electrocardiographic and electrophysiological data from 8 patients found to have PAVAs with preferential conduction out of 183 patients (4.4%) with right ventricular outflow tract (RVOT) arrhythmias who underwent RFCA at our hospitals. The PAVA with preferential conduction were classified into two types. In type 1 PAVA, successful ablation sites (success-sites) exhibited discrete prepotentials with an isoelectric line, in which the activation time (AT) was ≥ 50 milliseconds. In type 2 PAVA, excellent pace mapping was achieved at two sites separated by ≥ 20 mm: one in the RVOT free wall and the other at the success-site in the pulmonary artery. Type 1 and 2 PAVA features were considered signs of a short and long preferential conduction pathway, respectively.There were four patients each with type 1 and 2 PAVA. Type 1 PAVA was distinguished by the isoelectric line at success-sites with the mean AT of 78 ± 25.1 milliseconds. In type 2 PAVAs, although the AT at RVOT sites was very short (18.5 ± 10.1 milliseconds), the AT at success-sites was longer than that at the RVOT by 42.3 ± 36.2 milliseconds. Type 2 PAVAs displayed distinct electrocardiogram (ECG) features (R wave in lead I, RR' in inferior leads, and transitional zone in V4) not found in typical PAVA ECGs.PAVA with preferential conduction can manifest in distinct ways on the ECG and intracardiac mapping. Knowledge of these features may facilitate successful RFCA of such PAVA cases.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Ablación por Catéter , Electrocardiografía , Arteria Pulmonar/fisiopatología , Adolescente , Adulto , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad
17.
Int Heart J ; 62(2): 320-328, 2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33731538

RESUMEN

Second-generation cryoballoon (CB) ablation is effective in achieving pulmonary vein (PV) isolation (PVI) in atrial fibrillation (AF) patients. The "crosstalk" (CST) phenomenon has been reported to reduce unnecessary applications during CB ablation. Nevertheless, it is unclear under what conditions the CST phenomenon occurs.To seek the predictors of the CST phenomenon during CB-guided PVI, CST phenomenon in achieving ipsilateral superior PVI during inferior PV ablation was analyzed in AF patients who underwent de novo ablation using CB. CB occlusion status and nadir balloon temperature (NT) were compared in these patients, and all ablated superior PVs were categorized into three groups according to the necessity of the touch up ablation and effectiveness of the phenomenon.Of 1082 superior PVs, 16, 40, and 1026 were classified into the CST success, CST failure, and control groups (unnecessary CST), respectively. The proportion of superior PVs ablated with complete occlusion using the CB was significantly higher in the CST success group than in the other two groups. The proportion of superior PVs ablated with NT ≤ -46°C was higher in the CST success group than in the CST failure group. The CST phenomenon was always observed if CB ablation of the superior PVs was performed with both complete occlusion and NT ≤ -46°C and was almost always ineffective if it did not meet these two criteria (sensitivity, 100%; specificity, 93%).Successful CST ablation was highly predicted if complete PV occlusion and NT ≤ -46°C during CB ablation of the superior PVs were achieved.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
18.
J Cardiovasc Electrophysiol ; 31(4): 875-884, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32017303

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) and linear ablation with a roof line and bottom line on the left atrial (LA) posterior wall (LAPW) can be achieved with a cryoballoon (CB). This study sought to investigate the long-term durability of these linear lesions. METHODS AND RESULTS: Among 290 persistent patients with atrial fibrillation (AF) who had undergone linear ablation with a CB on the roof and bottom line of the LAPW in addition to the PVI, we analyzed those patients who underwent a re-do AF ablation. Arrhythmia recurrence was confirmed in 70 (24%) out of 290 patients, and 47 (16%) patients underwent re-do sessions. At the beginning of the re-do ablation, we examined the reconnection sites of the linear lesions on the LAPW and PVI. Maintenance of the conduction block on the LAPW roof and bottom lines was observed in 35 out of 47 patients (74.5%), and 16 out of 35 patients (45.7%), respectively. The length of the roof line was significantly shorter in patients with preservation of the conduction block on the LAPW roof than in those without (36.2 ± 6.5 mm vs 41.6 ± 4.7 mm, P = .02). CONCLUSION: Durable lesions could be obtained after linear ablation with the CB for the LAPW roof line, especially in those with a relatively short LAPW roof line. However, patients requiring touch-up ablation with radiofrequency were included, and that was associated with a potential financial implication.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter , Criocirugía/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Pacing Clin Electrophysiol ; 43(1): 47-53, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31707738

RESUMEN

PURPOSE: The aim of this study was to test regional pharmacological effects of an antiarrhythmic agents to predict ablative effects. BACKGROUND: The vein of Marshall (VOM) providing vascular access to myocardial tissue has been used for ablative purposes using ethanol. METHODS: A total of 35 patients (male 21, 63.2 ± 7.8 years old) were included. A balloon-tipped infusion catheter was inserted into the VOM. Endocardial ultrahigh-resolution mapping was performed along the VOM region to record the change in atrial electrograms (AEs) after VOM injection of cibenzoline of 3.5 mg during sustained atrial fibrillation (AF). Subsequently, ethanol was infused into the VOM and ablative region was mapped. RESULTS: In 17 patients (49 %), cibenzoline reduced AEs amplitude by >50%, all of which had also complete elimination of AEs following ethanol (Group A). In 18 patients (Group B), cibenzoline failed to eliminate AEs; yet, in 13 of 18 AEs were eliminated by ethanol. In the remaining five patients, ethanol did not eliminate AE. CONCLUSIONS: Cibenzoline into the VOM could reliably predicts the results of subsequent ethanol infusion into the VOM using ultrahigh-resolution mapping system, which leads to avoid unnecessary permanent lesion creation by ethanol infusion.


Asunto(s)
Antiarrítmicos/farmacología , Fibrilación Atrial/terapia , Vasos Coronarios , Etanol/farmacología , Imidazoles/farmacología , Anciano , Ablación por Catéter/métodos , Medios de Contraste , Angiografía Coronaria , Electrocardiografía , Femenino , Fluoroscopía , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Flebografía
20.
Int Heart J ; 61(2): 249-253, 2020 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-32173706

RESUMEN

Cryoballoon ablation is an established catheter-based approach to treat atrial fibrillation (AF). However, thromboembolic events cannot be avoided during cryoablation. There is little data regarding the blood coagulation status during freezing.The thrombin antithrombin complex (TAT) and prothrombin fragment 1+2 (F 1+2) of patient blood were measured during cryoballoon application when the cryoballoon temperature reached the nadir in 63 AF patients. TAT was also measured from porcine blood during cryoballoon freezing in 5 pigs.The TAT and F 1+2 increased from 6.60 ± 5.65 to 9.16 ± 7.28 ng/mL (P = 0.004) and from 279.6 ± 146.4 to 323.6 ± 169.1 pmol/L (P = 0.003) between the control and during freezing, respectively. The TAT increased from 0.46 to 0.87 ng/mL during freezing compared to that of pre-freezing (P < 0.05), and it returned to 0.39 ng/mL in 30 minutes after an intravenous edoxaban administration (N.S.).Dabigatran failed to exert sufficient anticoagulant effects during cryofreezing. In contrast, intravenous edoxaban seemed to provoke anticoagulation effects under extreme low temperature circumstances.


Asunto(s)
Antitrombinas/uso terapéutico , Criocirugía/efectos adversos , Dabigatrán/uso terapéutico , Piridinas/uso terapéutico , Tiazoles/uso terapéutico , Tromboembolia/etiología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tromboembolia/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA