Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiol Med ; 129(4): 631-642, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38355907

RESUMEN

PURPOSE: Systemic chemotherapy (SYS) is the first-line treatment of unresectable intrahepatic cholangiocarcinoma (ICC). However, the survival benefit of SYS is still limited. This study compared the efficacy and safety of patients with unresectable ICC treated with transarterial chemoembolization (TACE) plus SYS to SYS alone. MATERIAL AND METHODS: The multicenter retrospective cohort study included patients aged ≥ 18 years old with pathologically diagnosed ICC. Patients with unmeasurable lesions, not receiving SYS treatment, Child-Pugh grade C, Eastern Cooperative Oncology Group performance status score of 3 or higher, prior liver resection, incomplete medical information, or discontinuation of the first SYS treatment were excluded. Data collection was mainly from the hospital system, and the survival outcome of patients was obtained through follow-up. Overall survival (OS) was estimated using the Kaplan-Meier method and compared using the log-rank test. Propensity score matching at a 1:1 ratio using the nearest neighbor matching algorithm was performed to reduce selection bias between the TACE plus SYS and SYS alone groups. The Cox proportional hazards model was used to identify prognostic factors associated with OS and to estimate their hazard ratios. Modified Response Evaluation Criteria in Solid Tumors criteria were utilized to evaluate the response of tumors to therapy. RESULTS: Between June 2016 and February 2023, 118 unresectable ICC patients from three hospitals were included in this study. Of them, 37 were in the TACE plus SYS group and 81 were in the SYS alone group. The median OS in the combination group was 11.3 months, longer than the 6.4 months in the SYS alone group (P = 0.011). A greater objective response rate (ORR) and disease control rate (DCR) were observed in the combination group than in the SYS alone group (ORR, 48.65 vs. 6.17%, P < 0.001; DCR, 89.19 vs. 62.96%, P = 0.004). There were 16 patients in each group after matching, and the matched results remained consistent regarding OS and tumor response. Adverse events (AEs) were similar in the two groups after matching. CONCLUSION: Compared to SYS alone, the combination treatment of TACE plus SYS was more effective than SYS alone in improving OS, ORR, and DCR without any significant increase in AEs. TACE plus SYS may be a viable treatment option for patients with unresectable ICC.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Quimioembolización Terapéutica , Colangiocarcinoma , Neoplasias Hepáticas , Humanos , Neoplasias de los Conductos Biliares/terapia , Conductos Biliares Intrahepáticos/patología , Carcinoma Hepatocelular/patología , Quimioembolización Terapéutica/métodos , Colangiocarcinoma/terapia , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Resultado del Tratamiento , Adulto
2.
Opt Express ; 30(9): 14645-14650, 2022 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-35473203

RESUMEN

A single-shot imaging system with multiple frames has been developed, which can record sequential multiple frames by delaying multiple optical images with fiber bundles and then capturing the images with a single intensified camera. The observed optical object is imaged through four lenses onto the end faces of four sets of fiber bundles. These fiber bundles with different lengths can provide different delays for delivering optical images, which determine the inter-frame separation times. The optical images exported from the fiber bundles are captured with a single intensified CMOS camera simultaneously. This imaging system has been applied for investigating the dynamic x-ray spot of the rod-pinch diode via a combination of scintillators, which are used to convert x-ray images to optical images. Four sequential x-ray images in a single shot have been obtained, which show the dynamic development of the rod-pinch x-ray spot. The results experimentally reveal the dynamics of the electrons flow bombarding the rod, which roughly agrees with the theoretical modeling of the rod-pinch diode.

3.
Eur Radiol ; 32(4): 2594-2603, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34779872

RESUMEN

OBJECTIVES: To investigate the correlation between the extent of excessive trabeculation assessed by fractal dimension (FD) and myocardial contractility assessed by cardiac MRI feature tracking in patients with left ventricular noncompaction (LVNC) and normal left ventricular ejection fraction (LVEF). METHODS: Forty-one LVNC patients with normal LVEF (≥ 50%) and 41 healthy controls were retrospectively included. All patients fulfilled three available diagnostic criteria on MRI. Cardiac MRI feature tracking was performed on cine images to determine left ventricular (LV) peak strains in three directions: global radial strain (GRS), global circumferential strain (GCS), and global longitudinal strain (GLS). The complexity of excessive trabeculation was quantified by fractal analysis on short-axis cine stacks. RESULTS: Compared with controls, patients with LVNC had impaired GRS, GCS, and GLS (all p < 0.05). The global, maximal, and regional FD values of the LVNC population were all significantly higher than those of the controls (all p < 0.05). Global FD was positively correlated with the end-diastolic volume index, end-systolic volume index, and stroke volume index (r = 0.483, 0.505, and 0.335, respectively, all p < 0.05), but negatively correlated with GRS and GCS (r = - 0.458 and 0.508, respectively, both p < 0.001). Moreover, apical FD was also weakly associated with LVEF and GLS (r = - 0.249 and 0.252, respectively, both p < 0.05). CONCLUSION: In patients with LVNC, LV systolic dysfunction was detected early by cardiac MRI feature tracking despite the presence of normal LVEF and was associated with excessive trabecular complexity assessed by FD. KEY POINTS: • Left ventricular global strain was already impaired in patients with extremely prominent excessive trabeculation but normal left ventricular ejection fraction. • An increased fractal dimension was associated with impaired deformation in left ventricular noncompaction.


Asunto(s)
Fractales , Disfunción Ventricular Izquierda , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Estudios Retrospectivos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
4.
Eur Radiol ; 30(2): 702-711, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31515621

RESUMEN

OBJECTIVES: To evaluate whether early left atrial (LA) dysfunction in hypertension (HTN), with or without left ventricular hypertrophy (LVH), can be detected by cardiovascular magnetic resonance feature tracking (CMR-FT). METHODS: Seventy-three HTN patients and 29 healthy controls were retrospectively recruited. HTN patients were divided into the LVH (n = 29) and non-LVH group (n = 44). LA performance was analysed using CMR-FT in 2- and 4-chamber cine images, including LA reservoir function (total ejection fraction [EF], total strain [εs], peak positive strain rate [SRs]), conduit function (passive EF, passive strain [εe], peak early negative strain rate [SRe]) and booster pump function (booster EF, active strain [εa], late peak negative strain rate [SRa]). One-way analysis of variance with post hoc LSD tests, Spearman analysis, receiver operating characteristic curve and intra-class correlation coefficient analysis were applied for statistical analyses. RESULTS: Compared with healthy controls, LA reservoir (LA total EF, εs, SRs) and conduit function (LA passive EF, εe, SRe) were significantly impaired in HTN patients with or without LVH, and these parameters significantly correlated with mitral E/A < 1 (all p < 0.05). However, LA booster pump function was relatively preserved in non-LVH patients, representing an intermediate stage between the LVH group and controls. Among LA deformation parameters, εe showed the highest diagnostic value for differentiation of HTN patients with healthy controls (AUC, 0.82; sensitivity, 80.82%; specificity, 72.41%). Observer reproducibility was good-excellent (ICC, 0.83-0.97) for all CMR-FT derived parameters. CONCLUSIONS: CMR-FT is a promising tool for quantification of LA function. LA reservoir and conduit dysfunction might be detected early by CMR-FT in HTN patients before the presence of LVH. KEY POINTS: • CMR-FT is a promising tool in quantifying LA function, including deformation and volumetric parameters. • LA reservoir and conduit dysfunction might be detected early by CMR-FT in HTN patients with or without LVH. • The LA booster pump function was relatively preserved in non-LVH patients.


Asunto(s)
Función del Atrio Izquierdo/fisiología , Hipertensión/fisiopatología , Imagen por Resonancia Magnética/métodos , Adulto , Diagnóstico Precoz , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
6.
Opt Express ; 25(25): 32074-32079, 2017 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-29245872

RESUMEN

An all-optical framing camera has been developed which measures the spatial profile of photons flux by utilizing a laser beam to probe the refractive index change in an indium phosphide semiconductor. This framing camera acquires two frames with the time resolution of about 1.5 ns and the inter frame separation time of about 13 ns by angularly multiplexing the probe beam on to the semiconductor. The spatial resolution of this camera has been estimated to be about 140 µm and the spectral response of this camera has also been theoretically investigated in 5 eV-100 KeV range. This camera has been applied in investigating the imploding dynamics of the molybdenum planar wire array Z-pinch on the 1-MA "QiangGuang-1" facility. This framing camera can provide an alternative scheme for high energy density physics experiments.

7.
Medicine (Baltimore) ; 100(7): e24720, 2021 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-33607812

RESUMEN

ABSTRACT: The purpose of this study was to explore the management experience of outpatient with totally implantable central venous access Ports (TIVAPs, Ports) during the epidemic, including whether the extension of the irrigation interval will affect the incidence of catheter occlusion, the reasons for the port removal rate, and the corresponding protective treatment strategies during the COVID-19 epidemic.We retrospectively analyzed the Ports evaluation and flushing procedure data between February 3, 2020 and April 3, 2020; the cases were divided into the normal group and delayed group according to the critical point of the maintenance interval of 28 days (4 weeks). We compared the incidence of catheter obstruction between the 2 groups, analyzed the causes of catheter removal events in the 2 groups, and proposed corresponding protective treatment recommendations.During the period, 329 cases were included in the study. There was no significant difference in the incidence of catheter obstruction between the 2 groups. There were 15 patients with catheter removal, 8 cases of infection, 5 cases of catheter obstruction, and 1 case of an ectopic catheter, as well as 1 case of an overturned port. During the epidemic, no hospital infections related to the Ports flushing procedure occurred.The interval of Ports flushing procedures for patients without clinical symptoms can be appropriately extended during the COVID-19 epidemic. However, once the local infection symptoms or other sources of discomfort appear, Ports assessment needs to be performed as soon as possible. Take enhanced protected and isolation measures did not increase cross-infection during outpatient's flushing procedure at non-COVID-19-designated diagnosis and treatment hospitals.


Asunto(s)
COVID-19/epidemiología , Cateterismo Venoso Central , Pacientes Ambulatorios , Remoción de Dispositivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , SARS-CoV-2
8.
Medicine (Baltimore) ; 98(27): e16224, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31277134

RESUMEN

Pneumothorax is a common complication in computed tomography (CT)-guided percutaneous lung biopsy (CPLB). Whether the lobar location of lesions contributes to the incidence of pneumothorax should be further clarified.A total of 1452 consecutive patients who underwent CPLB between January 2010 and March 2018 were retrospectively analyzed. The incidence of pneumothorax was compared among 5 different lobe biopsies. Minor pneumothorax was defined as pneumothorax without chest tube placement and major pneumothorax was defined as pneumothorax with chest tube placement.The positive diagnosis rate of pathology for this cohort was approximately 84%, with 22.5% (326/1452) of the patients experiencing pneumothorax. The rates of pneumothorax were 19.5%, 24.5%, 33.9%, 21.4%, and 23.9% for the right upper lobe, right lower lobe, right middle lobe, left upper lobe, and left lower lobe, respectively (P = .09). Chest tube placement was necessary in 19.0% (62/326) of the patients with pneumothorax. The rates of major pneumothorax were 5.3%, 2.6%, 10.2%, 4.7%, and 2.6% for the right upper lobe, right lower lobe, right middle lobe, left upper lobe, and left lower lobe biopsies, respectively (P = .02). This result was further confirmed by the propensity score-matching method. Moreover, 8.7% (127/1452) of the patients experienced puncture of fissure, the rates of which were 13.5%, 5%, 10.2%, 9.1%, and 4.3% for the right upper lobe, right lower lobe, right middle lobe, left upper lobe, and left lower lobe, respectively (P < .001). Within the pneumothorax patient group, the rate of lobe fissure puncture (15.2%) was significantly lower in patients with minor pneumothorax than (51.6%) in those with major pneumothorax (P < .001).Upper and middle lobe lesion biopsies show a significantly high rate of major pneumothorax, which may be due to more puncture of fissure. It is crucial to carefully distinguish the fissure around lesions and bypass it to avoid major pneumothorax.


Asunto(s)
Biopsia Guiada por Imagen/efectos adversos , Enfermedades Pulmonares/diagnóstico , Pulmón/patología , Tomografía Computarizada Multidetector/efectos adversos , Neumotórax/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , China/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Neumotórax/diagnóstico , Neumotórax/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
9.
Korean J Radiol ; 20(1): 114-125, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30627027

RESUMEN

Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.


Asunto(s)
Electrocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico/fisiología , Adulto , Arritmias Cardíacas/fisiopatología , Contencion de la Respiración , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA