Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Arch Otorhinolaryngol ; 280(12): 5433-5444, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37584753

RESUMEN

PURPOSE: This study examined and compared the diagnostic accuracy and correlation levels of the acoustic parameters of the audio recordings obtained from smartphones on two operating systems and from dynamic and condenser types of external microphones. METHOD: The study included 87 adults: 57 with voice disorder and 30 with a healthy voice. Each participant was asked to perform a sustained vowel phonation (/a/). The recordings were taken simultaneously using five microphones AKG-P220, Shure-SM58, Samson Go Mic, Apple iPhone 6, and Samsung Galaxy J7 Pro microphones in an acoustically insulated cabinet. Acoustic examinations were performed using Praat version 6.2.09. The data were examined using Pearson correlation and receiver-operating characteristic (ROC) analyses. RESULTS: The parameters with the highest area under curve (AUC) values among all microphone recordings in the time-domain analyses were the frequency perturbation parameters. Additionally, considering the correlation coefficients obtained by synchronizing the microphones with each other and the AUC values together, the parameter with the highest correlation coefficient and diagnostic accuracy values was the jitter-local parameter. CONCLUSION: Period-to-period perturbation parameters obtained from audio recordings made with smartphones show similar levels of diagnostic accuracy to external microphones used in clinical conditions.


Asunto(s)
Teléfono Inteligente , Acústica del Lenguaje , Adulto , Humanos , Calidad de la Voz , Reproducibilidad de los Resultados , Acústica , Medición de la Producción del Habla
2.
J Voice ; 2023 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-37482518

RESUMEN

OBJECTIVE: As in many health care fields, it is essential to establish clinical standards for voice assessments; however, some individual characteristics of clinicians, such as their personalities, may affect assessment reliability. Therefore, this study aims to examine the relationship between the personality traits and cognitive emotion regulation strategies of speech-language therapists (SLTs) and their GRBAS (Grade, Roughness, Breathiness, Asthenia, Strain) scoring. METHOD: The study group comprised 33 SLTs and 9 women with dysphonia. The Five-Factor Personality Inventory (FFPI) and Cognitive Emotion Regulation Questionnaire (CERQ) were used to assess SLTs' psychological traits. The SLTs evaluated the acoustic recordings of sustained vowel phonation /a/ obtained from individuals with dysphonia, using the GRBAS scale. Cronbach's alpha was used to assess inter-rater reliability, and Spearman's correlation analysis was used to analyze the relationships among the variables. RESULTS: The findings revealed that the FFPI dimensions were weakly and significantly related to Grade (G) and Strain (S). In the maladaptive dimensions, with an increase in the scores of the neuroticism dimension of FPPI and the catastrophizing dimension of CERQ, the SLTs gave significantly higher scores to Grade (G). In addition, with an increase in the score of rumination or focus on thought, the SLTs perceived Strain (S) more negatively. Consistent with these findings, in the adaptive dimensions, the SLTs gave higher scores to Grade (G) as the positive refocusing and positive reappraisal scores decreased. CONCLUSION: The findings of this study showed that, as some maladaptive aspects of personality and cognitive emotion regulation increased and adaptive aspects decreased, the SLTs' perceptions of Grade (G) and Strain (S) became more negative. Additionally, these results suggested the possibility of advanced confounding variables beyond primary factors, such as training and experience in the perceptual voice assessment of the SLTs, and the importance of standardizing professional practices, such as the observation and supervision of experts.

3.
J Commun Disord ; 106: 106380, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37738707

RESUMEN

OBJECTIVE: This study examines the Turkish validity, reliability and diagnostic performance of the Voice Handicap Index-Partner (VHI-P-TR), which is used to obtain the perceptions of communication partners of individuals with dysphonia about the functional, physical and emotional handicap resulting from the patient experiencing dysphonia. METHOD: The study included 160 individuals with dysphonia and their communication partners. First, translation, back translation, expert validity and pilot study were performed in the scale adaptation process. Then, a confirmatory factor analysis (CFA) was conducted to assess the construct validity of the VHI-P-TR. Correlations between the VHI-P-TR and Voice Handicap Index (VHI-TR) scores of dysphonic individuals were examined to evaluate the concurrent validity of the VHI-P-TR. To assess the reliability of the VHI-P-TR, a test-retest analysis was performed, and internal consistency coefficients (α) were calculated. A receiver operating characteristic (ROC) analysis was conducted to determine the cut-off point for the VHI-P scores. RESULTS: A high positive correlation was found between the participants' VHI-P-TR and VHI-TR total and subscales mean scores (r's > 0.782; p < 0.01). The VHI-P-TR had high internal consistency regarding for its subscales and total score (α's > 0.94; p < 0.01). Factor loadings of all VHI-P-TR items were higher than 0.30 and their error variances were lower than 0.90. In addition, factor loadings were statistically significant for all the items (p < 0.05). The data fit the model well according to all CFA indices except for GFI (scale = 0.69). An adequate sensitivity and specificity were achieved for the VHI-P-TR, and the cut-off point was found as 11.50 for the total score and ranged from 2.50 to 5.50 for the subscales. CONCLUSION: The VHI-P-TR is a valid and reliable measurement tool with high diagnostic performance in all subscales and total score, and has high levels of agreement with the VHI-TR.


Asunto(s)
Disfonía , Trastornos de la Voz , Humanos , Disfonía/diagnóstico , Reproducibilidad de los Resultados , Proyectos Piloto , Calidad de Vida , Evaluación de la Discapacidad , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios , Trastornos de la Voz/diagnóstico
4.
Logoped Phoniatr Vocol ; 47(4): 284-291, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34519593

RESUMEN

OBJECTIVE: To examine the power of the parameters obtained from different sustained vowels used in acoustic and electroglottographic (EGG) voice evaluation protocols to discriminate between dysphonic and non-dysphonic voice quality. METHODS: Sixty non-dysphonic participants and 30 dysphonic participants were included in the study. In addition to the time domain amplitude and frequency perturbation parameters obtained from the sustained phonation of /ʌ/-/ɛ/-/i/-/u/ vowels, several frequency-domain spectral/cepstral parameters and EGG parameters were evaluated. The classification performance of the acoustic and electroglottographic measures was quantified using analysis and receiver operating characteristic (ROC) curve analysis. RESULTS: As a result of ROC analysis, the discriminative diagnostic performance (area under the curve, AUC) of the test for low-vowel (/ʌ/-/ɛ/) phonation was higher than values obtained from high-vowel (/i/-/u/) phonation. For /ʌ/ and /ɛ/ sustained vowels, the parameters exhibiting the highest discrimination were fundamental frequency standard deviation (fo/STD), cepstral peak prominence (CPP), relative average perturbation (RAP), pitch perturbation quotient (PPQ), and jitter percent (JITT). In the EGG parameters, on the other hand, average jitter and periodicity parameters obtained from front vowels (/ɛ/-/i/) were found to have higher AUC values compared to back vowels (/ʌ/-/u/). CONCLUSIONS: In acoustic analyses, /ʌ/ and /ɛ/ sustained vowels give the highest diagnostic performance. In the electroglottographic evaluation, on the other hand, /ɛ/ and /i/ vowels, when the position of the tongue is forward, have better classification performance compared to /ʌ/ and /u/ vowels, when the position of the tongue is back.


Asunto(s)
Acústica del Lenguaje , Calidad de la Voz , Humanos , Curva ROC , Fonación , Acústica
5.
J Voice ; 2022 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-36567236

RESUMEN

OBJECTIVE: This study analyzes the effects of the vocal exercises called semi-occluded nasal tract exercises (SONTEs), which were carried out with a new appliance that extends the nasal cavity as a part of the vocal tract. The acoustic, aerodynamic and electroglottographic (EGG) measurements were compared with those of the traditional semi-occluded vocal tract exercises (SOVTEs) of phonation in water. METHODS: In this study, 34 women were randomly asked to perform phonation in water for 5 min through the nasal and oral routes with the sounds /m/ and /ɔ/, respectively, using a tube with a submersion depth of 5 cm. The acoustic, aerodynamic and EGG measurements before and after the exercises were analyzed using the appropriate statistical methods. RESULTS: No significant difference was found in the time and frequency domain parameters before and after the exercises, except for the amplitude perturbation quotient (APQ) values, which decreased after both exercises. In addition, there was no significant difference in any aerodynamic parameters before and after the exercises, but the mean SPL values significantly increased after both exercises. The oral and nasal peak inspiratory flow rates increased after both exercises, but the increase peaked after the SONTEs implementation. As expected, the EGG-jitter and EGG-periodicity values had a reciprocal interaction with each other, while differences were observed between the values of the vocal fold movements measured in both exercises. CONCLUSIONS: SONTEs may be as effective as the conventional SOVTEs because it made tube phonation into water possible through artificial extension of the nasal cavity and increased the resonant effect by using the positive effects based on the principles of SOVTEs.

6.
J Voice ; 2022 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-35973876

RESUMEN

OBJECTIVE: This study investigated the immediate effects and their persistence (at 15 minutes) of various durations of semi-occluded vocal tract exercise (SOVTE) (standard tube into water and modified mask+tube into water exercises) as measured by electroglottographic (EGG) and nasometric parameters. METHODS: The study included 30 women aged 19 through 28 years with healthy voices, and it comprised five randomly implemented procedures (Ps): P1-tube phonation into water for 5 minutes; P2-tube phonation into water for 10 minutes; P3-tube+ventilation mask phonation into water for 5 minutes; P4-tube+ventilation mask phonation into water for 10 minutes; P5-phonation with ventilation mask for 5 minutes. Fifteen-minute voice rest breaks were provided between each procedure. Nasometric and electroglottographic measurements were taken before, during, immediately after and at 5, 10, and 15 minutes after the exercises, and the recorded measurements were analyzed. RESULTS: The immediate effects of P3 and P4 on voice quality showed better performance than the other procedures. Among all the procedures, P1 had the smallest effect on voice quality in terms of nasometric and EGG parameters and the least degree of effect permanence. In all the fluctuating SOVTE procedures except P1, the nasalance scores decreased (P1, P2, P3, and P4: fluctuating SOVTE; P5: steady SOVTE). CONCLUSION: The tube phonation exercises modified by the addition of a ventilation mask were highly advantageous in terms of EGG parameters. In addition to this, regardless of the mode of application of the retention time, it was observed that the positive effect (ie, lower vertical laryngeal position) of the exercises applied for 10 minutes was higher than the exercises applied for 5 minutes.

7.
J Voice ; 2022 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-35623981

RESUMEN

OBJECTIVE: Within the scope of semi-occluded vocal tract exercises (SOVTEs), we aimed to examine the effects of four exercise combinations, which involved various fluid densities and tube submersion depths, on acoustic and electroglottographic (EGG) parameters. METHODS: Four procedures (P) were applied consecutively to 30 female participants with normal voices using different tube submersion depths and fluid densities, including P1 (2 cm, water), P2 (2 cm, nectar), P3 (10 cm, water), and P4 (10 cm, nectar). Nasometric (Nasometer II model 6450) and EGG (Electroglottograph model 6103) measurements were taken before the procedures were initiated (pre-test) and at the end of each procedure. In addition, EGG measurements were taken for each procedure during the application. RESULTS: For all three velar positions (oral passage, oro-nasal passage, nasal passage), the only procedure that caused a significant change compared to the pre-test stage in regard to nasalance score was P2 (2 cm nectar) in common. All other procedures except P1 (2 cm water) significantly increased velar closure compared to pre-test levels. However, when the differences between the exercises were examined, the least velar closure, compared to the other procedures, was obtained after P4 (10 cm nectar). While there was no significant difference between the procedures in the EGG measurements during the exercise, a significantly higher tendency to contact was observed after the procedures with a denser consistency, and an increase in the fundamental frequency (fo) values occurred in the pairwise comparisons of the procedures in the measurements after the exercises. CONCLUSION: In SOVTEs in which water phonation is performed with a tube, the use of a fluid with a consistency denser than water can be considered a particularly promising approach. In addition, exercises performed with increasing consistencies in 2 cm depth can provide more vocal cord and velopharyngeal port closure by increasing EGG-CQ and nasalance score values. However, more care should be taken while increasing the consistency at a submersion depth of 10 cm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA