Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Am Heart Assoc ; 9(11): e013227, 2020 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-32431188

RESUMEN

Background Atrial fibrillation (AF) is a major, often undetected, cardiac cause of stroke. Markers of atrial cardiopathy, including left atrial enlargement (LAE) or excessive atrial ectopy (EAE) increase the risk of AF and have shown associations with stroke. We sought to determine whether these markers improve stroke risk prediction beyond traditional vascular risk factors (eg CHA2DS2-VASc score). Methods and Results Retrospective longitudinal cohort of 32 454 consecutive community-dwelling adults aged ≥65 years referred for outpatient echocardiogram or Holter in Ontario, Canada (2010-2017). Moderate-severe LAE was defined as men >47 mm and women >43 mm, and EAE was defined as >30 APBs per hour. Cause-specific competing risks Cox proportional hazards used to estimate risk of ischemic stroke (primary), incident AF, and death (secondary). C-statistics, incremental discrimination improvement and net reclassification were used to compare CHA2DS2-VASc with LAE and EAE to CHA2DS2-VASc alone. Each 10 mm increase in left atrial diameter increased 2- and 5-year adjusted cause-specific stroke hazard almost 2-fold (LAE: 2-year hazard ratio (HR), 1.72; P=0.007; 5-year HR, 1.87; P<0.0001), while EAE showed no significant associations with stroke (2-year HR, 1.00; P=0.99; 5-year HR, 1.08, P=0.70), adjusting for incident AF. Stroke risk estimation improved significantly at 2 (C-statistics=0.68-0.75, P=0.008) and 5 years (C-statistics=0.70-0.76, P=0.003) with LAE and EAE. Conclusions LAE was independently associated with an increased risk of ischemic stroke in the absence of AF and both LAE and EAE improved stroke risk prediction. These findings have implications for stroke risk stratification, AF screening, and stroke prevention before the onset of AF.


Asunto(s)
Fibrilación Atrial/epidemiología , Accidente Cerebrovascular Isquémico/epidemiología , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo , Remodelación Atrial , Ecocardiografía , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Incidencia , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/mortalidad , Estudios Longitudinales , Masculino , Ontario/epidemiología , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
2.
J Nucl Med ; 58(1): 103-109, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27539843

RESUMEN

Three-dimensional (3D) mode imaging is the current standard for PET/CT systems. Dynamic imaging for quantification of myocardial blood flow with short-lived tracers, such as 82Rb-chloride, requires accuracy to be maintained over a wide range of isotope activities and scanner counting rates. We proposed new performance standard measurements to characterize the dynamic range of PET systems for accurate quantitative imaging. METHODS: 82Rb or 13N-ammonia (1,100-3,000 MBq) was injected into the heart wall insert of an anthropomorphic torso phantom. A decaying isotope scan was obtained over 5 half-lives on 9 different 3D PET/CT systems and 1 3D/2-dimensional PET-only system. Dynamic images (28 × 15 s) were reconstructed using iterative algorithms with all corrections enabled. Dynamic range was defined as the maximum activity in the myocardial wall with less than 10% bias, from which corresponding dead-time, counting rates, and/or injected activity limits were established for each scanner. Scatter correction residual bias was estimated as the maximum cavity blood-to-myocardium activity ratio. Image quality was assessed via the coefficient of variation measuring nonuniformity of the left ventricular myocardium activity distribution. RESULTS: Maximum recommended injected activity/body weight, peak dead-time correction factor, counting rates, and residual scatter bias for accurate cardiac myocardial blood flow imaging were 3-14 MBq/kg, 1.5-4.0, 22-64 Mcps singles and 4-14 Mcps prompt coincidence counting rates, and 2%-10% on the investigated scanners. Nonuniformity of the myocardial activity distribution varied from 3% to 16%. CONCLUSION: Accurate dynamic imaging is possible on the 10 3D PET systems if the maximum injected MBq/kg values are respected to limit peak dead-time losses during the bolus first-pass transit.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/fisiología , Imagenología Tridimensional/métodos , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
J Med Imaging Radiat Sci ; 47(2): 139-146, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31047177

RESUMEN

INTRODUCTION: Quality and safety in radiation treatment have garnered increasing attention in recent years. With the introduction of the CanMEDS 2015 Physician Competency Framework, incorporation of patient safety and quality improvement will be required across all seven established physician roles for radiation oncology residents. An appreciation for the competency areas relevant to radiation oncologists (ROs) in the quality and safety domain is thus needed to inform training in this area. METHODS: Semistructured interprofessional focus groups were held with ROs, medical physicists, and radiation therapists to ascertain the scope of quality principles required of newly certified ROs, to identify current teaching best practices, and to define required competencies in this area. Audio recordings were transcribed verbatim and data analyzed iteratively and coded using a constant comparison method. RESULTS: Three focus groups were held with 20 participants overall, and an average duration of 68 minutes (range 47-81 minutes). Participants found it difficult to define quality but noted that for residents it might encompass competencies in peer review, incident and change management, and quality culture. Although addressed in various ways in current residency programs, it was thought that explicit acknowledgment of relevant "nonmedical expert" quality competencies would ensure adequate attention in residency. CONCLUSIONS: Quality and safety are important concepts in radiation oncology, warranting attention in residency training to develop the knowledge, skills, and behaviour necessary in practice.

4.
J Nucl Med ; 55(1): 58-64, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24249797

RESUMEN

UNLABELLED: Rubidium-ARMI ((82)Rb as an Alternative Radiopharmaceutical for Myocardial Imaging) is a multicenter trial to evaluate the accuracy, outcomes, and cost-effectiveness of low-dose (82)Rb perfusion imaging using 3-dimensional (3D) PET/CT technology. Standardized imaging protocols are essential to ensure consistent interpretation. METHODS: Cardiac phantom qualifying scans were obtained at 7 recruiting centers. Low-dose (10 MBq/kg) rest and pharmacologic stress (82)Rb PET scans were obtained in 25 patients at each site. Summed stress scores, summed rest scores, and summed difference scores (SSS, SRS, and SDS [respectively] = SSS-SRS) were evaluated using 17-segment visual interpretation with a discretized color map. All scans were coread at the core lab (University of Ottawa Heart Institute) to assess agreement of scoring, clinical diagnosis, and image quality. Scoring differences greater than 3 underwent a third review to improve consensus. Scoring agreement was evaluated with intraclass correlation coefficient (ICC-r), concordance of clinical interpretation, and image quality using κ coefficient and percentage agreement. Patient (99m)Tc and (201)Tl SPECT scans (n = 25) from 2 centers were analyzed similarly for comparison to (82)Rb. RESULTS: Qualifying scores of SSS = 2, SDS = 2, were achieved uniformly at all imaging sites on 9 different 3D PET/CT scanners. Patient scores showed good agreement between core and recruiting sites: ICC-r = 0.92, 0.77 for SSS, SDS. Eighty-five and eighty-seven percent of SSS and SDS scores, respectively, had site-core differences of 3 or less. After consensus review, scoring agreement improved to ICC-r = 0.97, 0.96 for SSS, SDS (P < 0.05). The agreement of normal versus abnormal (SSS ≥ 4) and nonischemic versus ischemic (SDS ≥ 2) studies was excellent: ICC-r = 0.90 and 0.88. Overall interpretation showed excellent agreement, with a κ = 0.94. Image quality was perceived differently by the site versus core reviewers (90% vs. 76% good or better; P < 0.05). By comparison, scoring agreement of the SPECT scans was ICC-r = 0.82, 0.72 for SSS, SDS. Seventy-six and eighty-eight percent of SSS and SDS scores, respectively, had site-core differences of 3 or less. Consensus review again improved scoring agreement to ICC-r = 0.97, 0.90 for SSS, SDS (P < 0.05). CONCLUSION: (82)Rb myocardial perfusion imaging protocols were implemented with highly repeatable interpretation in centers using 3D PET/CT technology, through an effective standardization and quality assurance program. Site scoring of (82)Rb PET myocardial perfusion imaging scans was found to be in good agreement with core lab standards, suggesting that the data from these centers may be combined for analysis of the rubidium-ARMI endpoints.


Asunto(s)
Imagen Multimodal/métodos , Imagen Multimodal/normas , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Radioisótopos de Rubidio , Tomografía Computarizada por Rayos X/métodos , Anciano , Canadá , Análisis Costo-Beneficio , Femenino , Corazón/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados , Tomografía Computarizada de Emisión de Fotón Único/métodos , Investigación Biomédica Traslacional , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA