Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 21(4): 662-669, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30462198

RESUMEN

AIMS: This was a randomized controlled study performed to compare 8 mm-tip catheter cryoablation (CRYO) with radiofrequency ablation (RFA) in treating atrioventricular nodal re-entrant tachycardia (AVNRT). METHODS AND RESULTS: A total of 158 patients (103 women, mean age 48.9 ± 14.1) with symptomatic AVNRT (140 typical; 18 atypical) were randomized to undergo CRYO with an 8 mm-tip catheter (n = 80) or RFA (n = 78). The primary endpoint was a composite of acute procedural failure, inadvertent permanent atrioventricular block (AVB) and recurrence at 12 months. No significant difference was observed between CRYO and RFA groups in primary endpoint (7.5 vs. 11.5%; P = 0.764), 12-month recurrence rate (3.8 vs. 1.3%; P = 0.358), inadvertent permanent AVB (0 vs. 1.3%; P = 0.307), and acute procedural failure (3.7 vs. 9%; P = 0.128). In patients with acute procedure failure, success was achieved in 5 of 7 patients (71.4%) in RFA group and 2 of 3 patients (66.7%) in CRYO group on cross-over. There was no significant difference in procedural duration between CRYO and RFA groups (72.4 ± 41.6 vs. 63.7 ± 29.8 min; P = 0.13), but fluoroscopic duration in CRYO group was significantly shorter (3.4 ± 6.3 vs. 6.7 ± 7.4 min; P = 0.005). Patient pain score (2.7 ± 2.7 vs. 4.6 ± 2.7; P < 0.001) and operator stress score (2.3 ± 1.3 vs. 4.9 ± 2; P < 0.001) were significantly lower in CRYO group. CONCLUSIONS: Cryoablation with an 8 mm-tip catheter is shown to be comparable to RFA in treating AVNRT in terms of efficacy and safety. Additional advantages in CRYO include shorter fluoroscopic time, lower patient pain perception, and operator stress level.


Asunto(s)
Bloqueo Atrioventricular/epidemiología , Ablación por Catéter/métodos , Criocirugía/métodos , Complicaciones Posoperatorias/epidemiología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adulto , Anciano , Actitud del Personal de Salud , Criocirugía/instrumentación , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Dimensión del Dolor , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/fisiopatología , Complicaciones Posoperatorias/metabolismo , Recurrencia , Factores de Tiempo , Insuficiencia del Tratamiento , Resultado del Tratamiento , Troponina I/metabolismo , Adulto Joven
2.
Indian Pacing Electrophysiol J ; 17(6): 186-188, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29110935

RESUMEN

Leadless cardiac pacemakers (LCP) have become available recently. Both its acute and long-term performance in a large population of patients remain to be tested. Subacute rise in pacing threshold has been reported as an uncommon complication. On the other hand, the retrieval technique for LCP with passive fixation mechanism has not been previously described in details. Herein we report a newly recognized complication of an acute rise in pacing threshold very soon after implantation of an LCP without radiographic dislodgement. Percutaneous retrieval of this LCP with passive fixation mechanism was successful using a novel technique with the cryoballoon steerable sheath and a snare.

3.
Europace ; 17(9): 1391-401, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25736564

RESUMEN

AIMS: Atrial fibrillation (AF) cycle length (CL) has been demonstrated to be one of the predictors for termination during ablation for AF. We evaluated the AF CL gradient between right atrium (RA) and left atrium (LA) and their mean AF CL in predicting the extent of substrate ablation. METHODS AND RESULTS: One-hundred and thirty-six patients undergoing first ablation for persistent AF were studied. Stepwise ablation, sequentially in the following order: pulmonary veins (PV), LA, and RA, was performed to achieve AF termination. Stepwise ablation terminated AF in 110 patients (81%). In the AF termination group, AF was terminated by PV isolation (PVI) (Group P), PVI plus LA ablation (Group L), and PVI plus LA plus RA ablation (Group R) in 14 patients (13%), 49 patients (44%), and 47 patients (43%), respectively. Group R had much shorter mean AF CL than Group L (156 ± 18 vs. 174 ± 24 ms, P < 0.001) and mean AF CL in Group L was much shorter than Group P (174 ± 24 vs. 209 ± 36 ms, P = 0.004). The RA to LA AF CL gradient was not significantly different between left-side ablation (Group P + Group L) and additional RA ablation (Group R) (P = 0.177). Mean AF CL >180.50 ms predicted AF termination by PVI (Group P) with 79% sensitivity and 84% specificity while mean AF CL >165.25 ms predicted AF termination by left-side ablation (Group P + Group L) with 67% sensitivity and 75% specificity. After a mean follow-up of 15 ± 7 months, freedom from arrhythmia recurrence was significantly higher in left-side ablation (Group P + Group L) than additional RA ablation (Group R) (P = 0.024). CONCLUSION: Baseline mean AF CL may identify the subset of patients in whom persistent AF can be terminated by different extent of substrate ablation, which may in turn predict the chance of recurrence. However, baseline RA to LA AF CL gradient cannot predict the need for additional RA ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Venas Pulmonares/cirugía , Anciano , Electrocardiografía , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Pronóstico , Recurrencia , Sensibilidad y Especificidad
4.
Heart Lung Circ ; 23(1): 43-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23806197

RESUMEN

BACKGROUND: Long-term right ventricular apical (RVA) pacing causes adverse left ventricular (LV) remodelling and clinical outcomes. METHODS: Forty-one patients (19 men, mean age 70.9±14.2, 23 right ventricular septal and 18 RVA pacing) underwent pacemaker implantation for atrioventricular block. LV volumes and left ventricular ejection fraction (LVEF) were assessed by echocardiography 39.3±17.2 months after implantation. Predictors of left ventricular systolic volume (LVESV), left ventricular diastolic volume (LVEDV) and LVEF were analysed. RESULTS: No difference was found between RVA pacing and right ventricular septal pacing groups in LVESV (40.6±22.6 vs 33±14.4ml; p=0.199), LVEDV (88.2±31.2 vs 73.7±23.9ml; p=0.102) and LVEF (56.1±8.6 vs 56±6.6%; p=0.996). With multivariate stepwise regression, only pQRSd and renal impairment independently predicted LVESV (ß=0.522, 95% CI: 0.242-0.802; p=0.001 and ß=40.3, 95% CI: 17.6-62.9; p=0.001 respectively), LVEDV (ß=0.786, 95% CI: 0.338-1.235; p=0.001 and ß=42.8, 95% CI: 6.6-79; p=0.022 respectively) and LVEF (ß=-0.161, 95% CI: -0.283 to -0.04; p=0.011 and ß=-14.8, 95% CI: -24.6 to -5.0; p=0.004 respectively). CONCLUSIONS: pQRSd and renal impairment, but not pacing site or baseline LVEF, may be predictors for LV volumes and systolic function after long-term RV pacing. pQRSd may be target for pacing site optimisation.


Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Volumen Sistólico , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
5.
Europace ; 13(10): 1406-10, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21561902

RESUMEN

AIMS: Iatrogenic atrial septal defect (IASD) has been reported as a complication of transseptal puncture. This study aims to investigate the incidence, echocardiographic characteristics, and clinical outcome of persistent IASD after pulmonary vein isolation (PVI) by cryoballoon catheter delivered by a large transseptal sheath. METHODS AND RESULTS: Thirteen patients (9 males, mean age 54.9 ± 13.0) with paroxysmal (10) or persistent (3) atrial fibrillation underwent PVI with cryoballoon catheter. Single transseptal puncture was performed with a BRK-1 shaped Brockenbrough needle and an 8 F sheath which was exchanged for a steerable transseptal sheath (15 F outer diameter and 12 F inner diameter) with the support of a stiff guidewire. Pulmonary vein isolation was performed with a 28 mm cryoballoon catheter. The incidence of persistent IASD was evaluated by transoesophageal echocardiography performed at 6 and 9 months after the procedure. At 6 months, five (38%) patients had persistent IASD with left-to-right shunt. The mean size of the IASD was 5.5 ± 2.4 mm. At 9 months, one patient had closure of the IASD and four (31%) patients had persistent IASD with mean size of 4.6 ± 1.4 mm. No patient died or suffered clinically from paradoxical embolism. CONCLUSIONS: Persistent IASD is a common complication after PVI by cryoballoon catheter. Only left-to-right, but not right-to-left, interatrial shunting occurred as a result of the IASD. There was no clinical occurrence of paradoxical embolism. Patients should be screened for this complication after cryoballoon procedures and regular reassessment with echocardiographic or other techniques should be performed for monitoring.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Cateterismo/efectos adversos , Criocirugía/efectos adversos , Defectos del Tabique Interatrial/etiología , Enfermedad Iatrogénica , Venas Pulmonares/cirugía , Adulto , Anciano , Anticoagulantes/uso terapéutico , Aspirina/uso terapéutico , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Cateterismo/instrumentación , Cateterismo/métodos , Criocirugía/instrumentación , Criocirugía/métodos , Ecocardiografía , Embolia Paradójica/prevención & control , Femenino , Estudios de Seguimiento , Defectos del Tabique Interatrial/diagnóstico por imagen , Tabiques Cardíacos/lesiones , Humanos , Enfermedad Iatrogénica/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos , Punciones/instrumentación , Punciones/métodos , Resultado del Tratamiento , Warfarina/uso terapéutico
6.
Pacing Clin Electrophysiol ; 34(1): 2-7, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20727096

RESUMEN

BACKGROUND: Cryoablation (CRYO) is an alternative to radiofrequency (RF) ablation in the treatment of atrioventricular nodal reentrant tachycardia (AVNRT). This study aims to evaluate the differences in patient pain perception and operator stress between CRYO and RF ablation in the treatment of AVNRT. METHODS: Patients with supraventricular tachycardia underwent electrophysiology study. Twenty patients (eight males, age 46.5 ± 12.5 years) diagnosed with AVNRT were randomized to receive CRYO (11) with a 6-mm-tip catheter or RF (nine) with a 4-mm-tip catheter. Patients' pain perception and operator stress were assessed with a visual analogue scale (VAS) from 0 to 10 at the end of procedure. RESULTS: There was no significant difference in acute procedural success (CRYO 100% vs RF 89%, P = 0.257). There was no complication of permanent atrioventricular block in either group. The number of energy applications was significantly higher in the CRYO group (2.8 ± 1.2 vs 1.6 ± 0.9, P = 0.02). The fluoroscopic time was significantly reduced in the CRYO group (6.0 ± 4.9 vs 10.9 ± 5.4 minutes, P = 0.049) with no difference in procedure time (CRYO 49.3 ± 12.5 vs RF 54.5 ± 17.0 minutes, P = 0.462). Patients in the CRYO group experienced significantly less pain than patients in the RF group (VAS 2.3 ± 2.8 vs 5.4 ± 3.4, P = 0.024). The operator also experienced significantly less stress during CRYO than RF (VAS 1.9 ± 0.8 vs 6.2 ± 1.6, P < 0.001). There was no recurrence in both groups at 6-month follow-up. CONCLUSIONS: CRYO, as compared with RF, produces less pain in patients and less stress in operator in the treatment of AVNRT.


Asunto(s)
Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Dolor Postoperatorio/etiología , Médicos/psicología , Estrés Psicológico/etiología , Estrés Psicológico/psicología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor Postoperatorio/prevención & control , Estrés Psicológico/prevención & control , Resultado del Tratamiento
7.
Front Physiol ; 11: 574590, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33071830

RESUMEN

BACKGROUND: The aim of this study is to report on the genetic composition of Brugada syndrome (BrS) patients undergoing genetic testing in Hong Kong. METHODS: Patients with suspected BrS who presented to the Hospital Authority of Hong Kong between 1997 and 2019, and underwent genetic testing, were analyzed retrospectively. RESULTS: A total of 65 subjects were included (n = 65, 88% male, median presenting age 42 [30-54] years old, 58% type 1 pattern). Twenty-two subjects (34%) showed abnormal genetic test results, identifying the following six novel, pathogenic or likely pathogenic mutations in SCN5A: c.674G > A, c.2024-11T > A, c.2042A > C, c.4279G > T, c.5689C > T, c.429del. Twenty subjects (31%) in the cohort suffered from spontaneous ventricular tachycardia/ventricular fibrillation (VT/VF) and 18 (28%) had incident VT/VF over a median follow-up of 83 [Q1-Q3: 52-112] months. Univariate Cox regression demonstrated that syncope (hazard ratio [HR]: 4.27 [0.95-19.30]; P = 0.059), prior VT/VF (HR: 21.34 [5.74-79.31; P < 0.0001) and T-wave axis (HR: 0.970 [0.944-0.998]; P = 0.036) achieved P < 0.10 for predicting incident VT/VF. After multivariate adjustment, only prior VT/VF remained a significant predictor (HR: 12.39 [2.97-51.67], P = 0.001). CONCLUSION: This study identified novel mutations in SCN5A in a Chinese cohort of BrS patients.

8.
J Interv Card Electrophysiol ; 57(3): 425-434, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31016428

RESUMEN

PURPOSE: We aimed to study the long-term outcomes of cryoballoon (CB) pulmonary vein isolation (PVI) in treating Chinese patients with atrial fibrillation (AF). METHODS: A total of 122 patients (48 women, mean age 57.4 ± 11.3) underwent CB PVI (first generation CB 44.3%, second generation CB 55.7%) for AF (paroxysmal 65.6%, persistent 10.7% and long-standing persistent 23.8%). RESULTS: PVI was achieved in 113 (92.6%) patients with CB alone, and it was achieved in all patients with additional touch-up by 8-mm-tip cryocatheter. The mean procedural and fluoroscopic duration were 171.9 ± 41 and 46.6 ± 14.6 min respectively. The recurrence-free survival for paroxysmal and non-paroxysmal AF was 77% and 59% respectively at 1 year and progressively declined over time to reach a plateau of 52% and 30% for paroxysmal and non-paroxysmal AF respectively at 5 years. In patients undergoing PVI with second-generation CB, the recurrence-free survival was 75% for paroxysmal AF and 45% for non-paroxysmal AF at 5 years. With multivariate Cox regression analysis, the types of CB (use of second-generation CB: HR 0.49; 95% CI 0.28-0.85; p = 0.011) and size of left atrium (LA) (larger LA size: HR 1.52; 95% CI 1-2.14; p = 0.017) independently predicted recurrence. Transient phrenic nerve injury (PNI) occurred in four (3.3%) patients and persistent PNI occurred in four (3.3%) patients. Other complications occurred in 10 (8.2%) patients with no procedure-related death. CONCLUSIONS: Long-term success of CB PVI for AF declined over time and reached a plateau at 5 years. CB types and LA size are independent predictors for long-term recurrence.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Venas Pulmonares/cirugía , China , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias
9.
Can J Cardiol ; 35(4): 396-404, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30935630

RESUMEN

BACKGROUND: Persistent iatrogenic atrial septal defect (iASD) is a common but poorly characterized complication after cryoballoon (CB) pulmonary vein isolation (PVI) procedures. We therefore investigate its prevalence, evolution, risk factors, and clinical outcomes in a prospective longitudinal study. METHODS: A total of 108 patients (41 women, mean age 57 ± 11.3) underwent CB PVI for AF. Serial transesophageal echocardiography (TEE) was performed 9 months and then annually until 6 years after the procedure to study the characteristics of persistent iASD. RESULTS: Persistent iASD occurred in 33 (30.6%) patients 9 months after CB PVI. Spontaneous closure of iASD was found in 6 (22.2%) and 3 (15.8%) patients 2 and 3 years after the procedures, respectively. No spontaneous closure was observed on 4, 5, and 6-year TEE follow-up. The projected long-term persistence rate of iASD after CB PVI was therefore 20% (30.6% × 0.778 × 0.842). Using multivariate logistic regression, a higher number of cryoapplications (≥ 2 minutes) was the only independent predictor of persistent iASD 9 months after CB PVI (odds ratio [OR] 1.207; 95% confidence interval [CI], 1.033-1.411, P = 0.018). Two (1.9%) patients with significantly larger iASD size than the others (long diameter 12.6 ± 0.8 vs 3.7 ± 1.5 mm, P < 0.001; short diameter 10.9 ± 0.2 vs 3 ± 1.1 mm, P < 0.001) required percutaneous closure because of exertional dyspnea and right ventricular enlargement. Over 129.7 patient-years follow-up, during which iASD persisted, there was no occurrence of neurologic events. CONCLUSIONS: Approximately one fifth of patients undergoing CB PVI will have permanently persistent iASD. Patients with defect sizes of greater than 10 mm may need percutaneous closure due to significant left-to-right shunting.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Defectos del Tabique Interatrial/etiología , Enfermedad Iatrogénica , Ablación por Catéter/métodos , Ecocardiografía Transesofágica , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/cirugía
10.
Pacing Clin Electrophysiol ; 31(6): 772-5, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18507554

RESUMEN

Electrolyte disturbances are known to cause acquired Long QT syndrome (LQTS) and Brugada syndrome. While a reduction in INa due to SCN5A mutation is implicated as the underlying mechanism in Brugada syndrome, hyponatremia, which can give rise to a reduced INa, has never been reported in literature as a cause or precipitating factor in this syndrome. We detailed a case in which concomitant-acquired LQTS and Brugada syndrome were associated with severe hypokalemia and hyponatremia following indapamide use for treatment of hypertension and highlighted the potential role of hyponatremia in the pathogenesis of the acquired form of Brugada syndrome.


Asunto(s)
Síndrome de Brugada/inducido químicamente , Hipopotasemia/inducido químicamente , Hiponatremia/inducido químicamente , Indapamida/efectos adversos , Síndrome de QT Prolongado/inducido químicamente , Antihipertensivos/efectos adversos , Síndrome de Brugada/diagnóstico , Humanos , Hipopotasemia/diagnóstico , Hiponatremia/diagnóstico , Síndrome de QT Prolongado/diagnóstico , Masculino , Persona de Mediana Edad
12.
J Interv Card Electrophysiol ; 37(2): 169-77, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23508747

RESUMEN

PURPOSE: This study aims to investigate whether the use of a novel inner lumen circular mapping catheter (IMC) can shorten the procedural duration and fluoroscopic exposure of the single transseptal big cryoballoon (CB) pulmonary vein isolation (PVI) procedures in patients with atrial fibrillation (AF). METHODS: This is a prospective non-randomized case-control study. Forty-two patients (28 men, mean age 55.7 ± 12.1) with drug-refractory paroxysmal or persistent AF and underwent CB PVI procedures were divided into Group A (conventional single transseptal big CB approach, n = 21) and Group B (IMC-facilitated approach, n = 21). They were compared in the co-primary endpoints: (1) procedural duration and (2) fluoroscopic exposure and secondary endpoints: (1) 6-month AF-free survival and (2) number of cryo-applications. RESULTS: Both the procedural duration (162 ± 26 vs. 215 ± 25 min; p < 0.001) and fluoroscopic exposure (44.1 ± 10.4 vs. 56.8 ± 11.7 min; p = 0.001) were significantly shorter in Group B than Group A patients. With multivariate stepwise regression, only the use of IMC was an independent predictor for procedural duration (ß = -59; 95 % CI, -84.1 to -33.8; p < 0.001) and fluoroscopic exposure (ß = -16.9; 95 % CI, -28.4 to -5.4; p = 0.006). The number of cryo-applications was significantly fewer in Group B than Group A patients (median 8 vs. 11; p = 0.001). There was no significant difference in the 6-month AF-free survival between the two approaches (57 % vs. 71 %; p = 0.351). CONCLUSIONS: Compared to conventional single transseptal big CB PVI procedures, the use of IMC may reduce procedural duration, fluoroscopic exposure and the number of cryo-applications with comparable mid-term efficacy.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/instrumentación , Catéteres Cardíacos , Criocirugía/instrumentación , Dosis de Radiación , Cirugía Asistida por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Venas Pulmonares/cirugía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
13.
J Interv Card Electrophysiol ; 34(3): 295-301, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22403042

RESUMEN

PURPOSE: Catheter cryoablation (CRYO) may eliminate inadvertent atrioventricular block (AVB) in the treatment of atrioventricular nodal reentrant tachycardia (AVNRT). However, higher recurrence was observed with CRYO delivered by 4 mm or 6 mm-tip catheter. This study was performed to investigate whether a comparably low treatment failure and recurrence rate as in radiofrequency (RF) ablation is achievable by CRYO with an 8-mm-tip catheter. METHODS: This is a retrospective case-control study including 40 patients with AVNRT treated with CRYO (n = 20) using an 8 mm-tip catheter or RF ablation (n = 20) from March 2009 to March 2011. Treatment failure was defined as the composite of acute procedural failure including inadvertent permanent AVB and documented recurrence. RESULTS: Acute procedural success of 90% (18/20) and 95% (19/20) were achieved in CRYO and RF ablation group, respectively (p = 0.998), with no permanent AVB in either group. With Kaplan-Meier analysis, there was no significant difference between the treatment groups in terms of recurrence rate (5.6% [1/18] vs. 0%; log-rank test p = 0.304) and treatment failure (15% [3/20] vs. 5% [1/20]; log-rank test p = 0.301). Shorter fluoroscopy time (15 ± 8.6 vs. 25.2 ± 12.1 min; p = 0.005) and more energy applications (median 4 [2-15] vs. 2 [1-8]; p = 0.005) were observed in the CRYO group compared with RF ablation group. CONCLUSIONS: Compared to RF ablation, CRYO with an 8-mm-tip catheter for treating AVNRT achieves a comparable acute procedural success, comparably low recurrence rate and composite endpoint of treatment failure. Shorter fluoroscopy time and more energy applications were observed in the CRYO group.


Asunto(s)
Criocirugía/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adulto , Estudios de Casos y Controles , Ablación por Catéter/métodos , Distribución de Chi-Cuadrado , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Estadísticas no Paramétricas , Análisis de Supervivencia , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Resultado del Tratamiento
14.
J Interv Card Electrophysiol ; 32(1): 67-71, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21826507

RESUMEN

PURPOSE: This study aimed to evaluate the utility of a novel pacing guidewire in pre-implantation testing of different left ventricular (LV) sites during cardiac resynchronization therapy (CRT) procedures. METHODS: Ten consecutive patients (8 male, mean age 65.8 ± 4.9) undergoing CRT procedures were studied. Pacing threshold and R-wave sensing measured by the guidewire and LV lead at different LV sites were compared. RESULTS: Thirty sites (6 apical, 13 middle, and 11 basal; 15 lateral and 15 anterior) were tested. There was significant correlation between pacing threshold (r = 0.878, p < 0.0001), and R-wave sensing (r = 0.896, p < 0.0001) obtained by guidewire and those obtained by LV lead. Separating into lateral and anterior sites, significant correlation was also found in pacing threshold (lateral r = 0.658, p = 0.008; anterior r = 0.886, p < 0.0001) and R-wave sensing (lateral r = 0.887, p < 0.0001; anterior 0.865, p < 0.0001). For basal and middle sites, significant correlation was found in pacing threshold (basal r = 0.890, p < 0.0001; middle r = 0.878, p < 0.0001), and R-wave sensing (basal r = 0.930, p < 0.0001; middle r = 0.823, p < 0.001). No and borderline correlation was found in pacing threshold (r = 0.548, p = 0.26) and R-wave sensing (r = 0.835, p = 0.039), respectively, for apical sites. Concordance rate for the presence of phrenic nerve stimulation at high pacing output was 87%. CONCLUSION: The accuracy of the novel pacing guidewire in pre-implantation testing in CRT procedures is site-dependent. There was good correlation with LV lead in the measurement of pacing threshold and R-wave sensing at basal and middle sites, but not apical sites. Presence of phrenic nerve stimulation can be predicted by guidewire testing with high accuracy.


Asunto(s)
Terapia de Resincronización Cardíaca , Marcapaso Artificial , Implantación de Prótesis/instrumentación , Anciano , Terapia de Resincronización Cardíaca/métodos , Electrodos Implantados , Femenino , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
15.
Chin Med J (Engl) ; 123(13): 1645-51, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20819622

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) is an effective electrical therapy for patients with moderate to severe heart failure and cardiac dyssynchrony. This study aimed to investigate the degree of acute left ventricular (LV) resynchronization with biventricular pacing (BVP) at different LV sites and to examine the feasibility of performing transthoracic echocardiography (TTE) to quantify acute LV resynchronization during CRT procedure. METHODS: Fourteen patients with NYHA Class III-IV heart failure, LV ejection fraction < or = 35%, QRS duration > or = 120 ms and septal-lateral delay (SLD) > or = 60 ms on tissue Doppler imaging (TDI), underwent CRT implant. TDI was obtained from three apical views during BVP at each accessible LV site and SLD during BVP was derived. Synchronicity gain index (Sg) by SLD was defined as (1 + (SLD at baseline--SLD at BVP)/SLD at baseline). RESULTS: Seventy-two sites were studied. Positive resynchronization (R+, Sg > 1) was found in 42 (58%) sites. R+ was more likely in posterior or lateral than anterior LV sites (66% vs. 36%, P < 0.001). Concordance of empirical LV lead implantation sites and sites with R+ was 50% (7/14). CONCLUSIONS: The degree of acute LV resynchronization by BVP depends on LV lead location and empirical implantation of LV lead results in only 50% concordance with R+. Performing TTE during CRT implantation is feasible to identify LV sites with positive resynchronization.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ecocardiografía/métodos , Insuficiencia Cardíaca/terapia , Disfunción Ventricular Izquierda/terapia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA