Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 369(7): 640-8, 2013 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-23944301

RESUMEN

BACKGROUND: Recent advances have enabled delivery of high-intensity focused ultrasound through the intact human cranium with magnetic resonance imaging (MRI) guidance. This preliminary study investigates the use of transcranial MRI-guided focused ultrasound thalamotomy for the treatment of essential tremor. METHODS: From February 2011 through December 2011, in an open-label, uncontrolled study, we used transcranial MRI-guided focused ultrasound to target the unilateral ventral intermediate nucleus of the thalamus in 15 patients with severe, medication-refractory essential tremor. We recorded all safety data and measured the effectiveness of tremor suppression using the Clinical Rating Scale for Tremor to calculate the total score (ranging from 0 to 160), hand subscore (primary outcome, ranging from 0 to 32), and disability subscore (ranging from 0 to 32), with higher scores indicating worse tremor. We assessed the patients' perceptions of treatment efficacy with the Quality of Life in Essential Tremor Questionnaire (ranging from 0 to 100%, with higher scores indicating greater perceived disability). RESULTS: Thermal ablation of the thalamic target occurred in all patients. Adverse effects of the procedure included transient sensory, cerebellar, motor, and speech abnormalities, with persistent paresthesias in four patients. Scores for hand tremor improved from 20.4 at baseline to 5.2 at 12 months (P=0.001). Total tremor scores improved from 54.9 to 24.3 (P=0.001). Disability scores improved from 18.2 to 2.8 (P=0.001). Quality-of-life scores improved from 37% to 11% (P=0.001). CONCLUSIONS: In this pilot study, essential tremor improved in 15 patients treated with MRI-guided focused ultrasound thalamotomy. Large, randomized, controlled trials will be required to assess the procedure's efficacy and safety. (Funded by the Focused Ultrasound Surgery Foundation; ClinicalTrials.gov number, NCT01304758.).


Asunto(s)
Temblor Esencial/terapia , Técnicas Estereotáxicas , Terapia por Ultrasonido , Núcleos Talámicos Ventrales , Anciano , Mapeo Encefálico , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Proyectos Piloto , Terapia por Ultrasonido/efectos adversos , Terapia por Ultrasonido/métodos , Núcleos Talámicos Ventrales/patología
2.
J Neurol Neurosurg Psychiatry ; 86(3): 257-64, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24876191

RESUMEN

BACKGROUND: Several options exist for surgical management of essential tremor (ET), including radiofrequency lesioning, deep brain stimulation and γ knife radiosurgery of the ventralis intermedius nucleus of the thalamus. Recently, magnetic resonance-guided focused ultrasound (MRgFUS) has been developed as a less-invasive surgical tool aimed to precisely generate focal thermal lesions in the brain. METHODS: Patients underwent tremor evaluation and neuroimaging study at baseline and up to 6 months after MRgFUS. Tremor severity and functional impairment were assessed at baseline and then at 1 week, 1 month, 3 months and 6 months after treatment. Adverse effects were also sought and ascertained by directed questions, neuroimaging results and neurological examination. RESULTS: The current feasibility study attempted MRgFUS thalamotomy in 11 patients with medication-resistant ET. Among them, eight patients completed treatment with MRgFUS, whereas three patients could not complete the treatment because of insufficient temperature. All patients who completed treatment with MRgFUS showed immediate and sustained improvements in tremors lasting for the 6-month follow-up period. Skull volume and maximum temperature rise were linearly correlated (linear regression, p=0.003). Other than one patient who had mild and delayed postoperative balance, no patient developed significant postsurgical complications; about half of the patients had bouts of dizziness during the MRgFUS. CONCLUSIONS: Our results demonstrate that MRgFUS thalamotomy is a safe, effective and less-invasive surgical method for treating medication-refractory ET. However, several issues must be resolved before clinical application of MRgFUS, including optimal patient selection and management of patients during treatment.


Asunto(s)
Temblor Esencial/diagnóstico , Temblor Esencial/cirugía , Imagen por Resonancia Magnética Intervencional/métodos , Terapia por Ultrasonido/métodos , Núcleos Talámicos Ventrales/cirugía , Adulto , Anciano , Mapeo Encefálico , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Examen Neurológico , Adulto Joven
3.
Neurosurg Focus ; 32(1): E2, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22208895

RESUMEN

The object of this study was to describe a method of measuring targeting accuracy in functional neurosurgery using MR imaging and the Stereotactic Atlas of the Human Thalamus and Basal Ganglia. This method should be useful for any functional procedure using these tools or similar ones, and is described here in the specific context of focused ultrasound surgery. The authors describe the atlas coordinate system used, the different relevant targeting and accuracy definitions, the tools used, the intraoperative target determination, the postoperative target reconstructions, and the calculation of the therapeutic lesion volume. The proposed method has been applied to the specific situation of measuring targeting accuracy in focused ultrasound functional neurosurgery. The authors found mean absolute global targeting accuracies between 0.54 and 0.72 mm (SDs between 0.34 and 0.42 mm), with 85% of measured coordinates within 1 mm. The proposed method may be particularly useful in the context of functional neurosurgical procedures implying therapeutic ablations, be they through radiofrequency, focused ultrasound, or any other technique. This method allows an ongoing control of the targeting precision, a basic requirement in any functional neurosurgical procedure.


Asunto(s)
Encefalopatías/cirugía , Cirugía Asistida por Computador , Procedimientos Quirúrgicos Ultrasónicos/métodos , Humanos , Imagen por Resonancia Magnética , Procedimientos Neuroquirúrgicos/métodos , Sensibilidad y Especificidad , Técnicas Estereotáxicas
4.
Neurosurg Focus ; 32(1): E1, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22208894

RESUMEN

OBJECT: Recent technological developments open the field of therapeutic application of focused ultrasound to the brain through the intact cranium. The goal of this study was to apply the new transcranial magnetic resonance imaging-guided focused ultrasound (tcMRgFUS) technology to perform noninvasive central lateral thalamotomies (CLTs) as a treatment for chronic neuropathic pain. METHODS: In 12 patients suffering from chronic therapy-resistant neuropathic pain, tcMRgFUS CLT was proposed. In 11 patients, precisely localized thermal ablations of 3-4 mm in diameter were produced in the posterior part of the central lateral thalamic nucleus at peak temperatures between 51 ° C and 64 ° C with the aid of real-time patient monitoring and MR imaging and MR thermometry guidance. The treated neuropathic pain syndromes had peripheral (5 patients) or central (6 patients) origins and covered all body parts (face, arm, leg, trunk, and hemibody). RESULTS: Patients experienced mean pain relief of 49% at the 3-month follow-up (9 patients) and 57% at the 1-year follow-up (8 patients). Mean improvement according to the visual analog scale amounted to 42% at 3 months and 41% at 1 year. Six patients experienced immediate and persisting somatosensory improvements. Somatosensory and vestibular clinical manifestations were always observed during sonication time because of ultrasound-based neuronal activation and/or initial therapeutic effects. Quantitative electroencephalography (EEG) showed a significant reduction in EEG spectral overactivities. Thermal ablation sites showed sharply delineated ellipsoidal thermolesions surrounded by short-lived vasogenic edema. Lesion reconstructions (18 lesions in 9 patients) demonstrated targeting precision within a millimeter for all 3 coordinates. There was 1 complication, a bleed in the target with ischemia in the motor thalamus, which led to the introduction of 2 safety measures, that is, the detection of a potential cavitation by a cavitation detector and the maintenance of sonication temperatures below 60 ° C. CONCLUSIONS: The authors assert that tcMRgFUS represents a noninvasive, precise, and radiation-free neurosurgical technique for the treatment of neuropathic pain. The procedure avoids mechanical brain tissue shift and eliminates the risk of infection. The possibility of applying sonication thermal spots free from trajectory restrictions should allow one to optimize target coverage. The real-time continuous MR imaging and MR thermometry monitoring of targeting accuracy and thermal effects are major factors in optimizing precision, safety, and efficacy in an outpatient context.


Asunto(s)
Dolor Crónico/cirugía , Imagen por Resonancia Magnética , Neuralgia/cirugía , Cirugía Asistida por Computador , Tálamo/cirugía , Procedimientos Quirúrgicos Ultrasónicos/métodos , Estudios de Seguimiento , Humanos , Procedimientos Neuroquirúrgicos/métodos , Dimensión del Dolor
5.
Commun Biol ; 5(1): 964, 2022 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-36109574

RESUMEN

Ultrasound in combination with the introduction of microbubbles into the vasculature effectively opens the blood brain barrier (BBB) to allow the passage of therapeutic agents. Increased permeability of the BBB is typically demonstrated with small-molecule agents (e.g., 1-nm gadolinium salts). Permeability to small-molecule agents, however, cannot reliably predict the transfer of remarkably larger molecules (e.g., monoclonal antibodies) required by numerous therapies. To overcome this issue, we developed a magnetic resonance imaging analysis based on the ΔR2* physical parameter that can be measured intraoperatively for efficient real-time treatment management. We demonstrate successful correlations between ΔR2* values and parenchymal concentrations of 3 differently sized (18 nm-44 nm) populations of liposomes in a rat model. Reaching an appropriate ΔR2* value during treatment can reflect the effective delivery of large therapeutic agents. This prediction power enables the achievement of desirable parenchymal drug concentrations, which is paramount to obtaining effective therapeutic outcomes.


Asunto(s)
Encéfalo , Gadolinio , Imagen por Resonancia Magnética , Nanopartículas , Animales , Anticuerpos Monoclonales , Encéfalo/diagnóstico por imagen , Sistemas de Liberación de Medicamentos/métodos , Liposomas , Imagen por Resonancia Magnética/métodos , Ratas , Sales (Química)
6.
J Neurosurg ; 135(6): 1780-1788, 2021 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-34020416

RESUMEN

OBJECTIVE: Magnetic resonance imaging-guided focused ultrasound (MRgFUS) provides real-time monitoring of patients to assess tremor control and document any adverse effects. MRgFUS of the ventral intermediate nucleus (VIM) of the thalamus has become an effective treatment option for medically intractable essential tremor (ET). The aim of this study was to analyze the correlations of clinical and technical parameters with 12-month outcomes after unilateral MRgFUS thalamotomy for ET to help guide future clinical treatments. METHODS: From October 2013 to January 2019, data on unilateral MRgFUS thalamotomy from the original pivotal study and continued-access studies from three different geographic regions were collected. Authors of the present study retrospectively reviewed those data and evaluated the efficacy of the procedure on the basis of improvement in the Clinical Rating Scale for Tremor (CRST) subscore at 1 year posttreatment. Safety was based on the rates of moderate and severe thalamotomy-related adverse events. Treatment outcomes in relation to various patient- and sonication-related parameters were analyzed in a large cohort of patients with ET. RESULTS: In total, 250 patients were included in the present analysis. Improvement was sustained throughout the 12-month follow-up period, and 184 (73.6%) of 250 patients had minimal or no disability due to tremor (CRST subscore < 10) at the 12-month follow-up. Younger age and higher focal temperature (Tmax) correlated with tremor improvement in the multivariate analysis (OR 0.948, p = 0.013; OR 1.188, p = 0.025; respectively). However, no single statistically significant factor correlated with Tmax in the multivariate analysis. The cutoff value of Tmax in predicting a CRST subscore < 10 was 55.8°C. Skull density ratio (SDR) was positively correlated with heating efficiency (ß = 0.005, p < 0.001), but no significant relationship with tremor improvement was observed. In the low-temperature group, 1-3 repetitions to the right target with 52°C ≤ Tmax ≤ 54°C was sufficient to generate sustained tremor suppression within the investigated follow-up period. The high-temperature group had a higher rate of balance disturbances than the low-temperature group (p = 0.04). CONCLUSIONS: The authors analyzed the data of 250 patients with the aim of improving practices for patient screening and determining treatment endpoints. These results may improve the safety, efficacy, and efficiency of MRgFUS thalamotomy for ET.

7.
Ann Neurol ; 66(6): 858-61, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20033983

RESUMEN

Transcranial magnetic resonance (MR)-guided high-intensity focused ultrasound (tcMRgHIFU) implies a novel, noninvasive treatment strategy for various brain diseases. Nine patients with chronic neuropathic pain were treated with selective medial thalamotomies. Precisely located thermal ablations of 4mm in diameter were produced at peak temperatures of 51 degrees C to 60 degrees C under continuous visual MR guidance and MR thermometry. The resulting lesions are clearly visible on follow-up MR imaging. All treatments were well tolerated, without side effects or neurological deficits. This is the first report on successful clinical application of tcMRgHIFU in functional brain disorders, portraying it as safe and reliable for noninvasive neurosurgical interventions.


Asunto(s)
Procedimientos Neuroquirúrgicos/métodos , Manejo del Dolor , Dolor/patología , Terapia por Ultrasonido/métodos , Ultrasonido , Anciano , Encefalopatías/complicaciones , Mapeo Encefálico , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Dolor/etiología , Dimensión del Dolor , Tálamo/cirugía , Resultado del Tratamiento
8.
Front Neurosci ; 14: 592763, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33510610

RESUMEN

OBJECTIVE: Magnetic resonance-guided focused ultrasound surgery (MRgFUS) lesioning is a new treatment for brain disorders. However, the skull is a major barrier of ultrasound sonication in MRgFUS because it has an irregular surface and varies its size and shape among individuals. We recently developed the concept of skull density ratio (SDR) to select candidates for MRgFUS from among patients with essential tremor (ET). However, SDR is not the only factor contributing to successful MRgFUS lesioning treatment-refining the target through exact measurement of the ultrasonic echo in the transducer also improves treatment efficacy. In the present study, we carried out MRgFUS lesioning using an autofocusing echo imaging technique. We aimed to evaluate the safety and efficacy of this new approach, especially in patients with low SDR in whom previous focusing methods have failed. METHODS: From December 2019 to March 2020, we recruited 10 patients with ET or Parkinson's disease (PD) who had a low SDR. Two patients dropped out of the trial due to the screening failure of other medical diseases. In total, eight patients were included: six with ET who underwent MRgFUS thalamotomy and two with PD who underwent MRgFUS pallidotomy. The autofocusing echo imaging technique was used in all cases. RESULTS: The mean SDR of the patients with ET was 0.34 (range: 0.29-0.39), while that of the patients with PD was 0.41 (range: 0.38-0.44). The mean skull volume of patients with ET was 280.57 cm3 (range: 227-319 cm3), while that of the patients with PD was 287.13 cm3 (range: 271-303 cm3). During MRgFUS, a mean of 15 sonications were performed, among which a mean of 5.63 used the autofocusing technique. The mean maximal temperature (Tmax) achieved was 55.88°C (range: 52-59°C), while the mean energy delivered was 34.75 kJ (range: 20-42 kJ) among all patients. No serious adverse events occurred during or after treatment. Tmax or sonication factors (skull volume, SDR, sonication number, autofocusing score, similarity score, energy range, and power) were not correlated with autofocusing technique (p > 0.05, autofocusing score showed a p-value of 0.071). CONCLUSION: Using autofocusing echo imaging lesioning, a safe and efficient MRgFUS treatment, is available even for patients with a low SDR. Therefore, the indications for MRgFUS lesioning could be expanded to include patients with ET who have an SDR < 0.4 and those with PD who have an SDR < 0.45. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov, identifier: NCT03935581.

9.
Front Oncol ; 10: 1663, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33014832

RESUMEN

Introduction: To overcome the blood-brain barrier (BBB) which interferes with the effect of chemotherapeutic agents, we performed multiple disruptions of BBB (BBBD) with magnetic resonance-guided focused ultrasound on patients with glioblastoma (GBM) during standard adjuvant temozolomide (TMZ) chemotherapy [clinical trial registration no.NCT03712293 (clinicaltrials.gov)]. We report a 1-year follow-up result of BBBD with TMZ for GBM. Methods: From September 2018 to January 2019, six patients were enrolled (four men and two women, median age: 53 years, range: 50-67 years). Of the six patients, five underwent a total of six cycles of BBBD during standard TMZ adjuvant therapy. One patient underwent three cycles of BBBD but continued with TMZ chemotherapy. The 1-year follow-up results of these six patients were reviewed. Results: The mean follow-up duration was 15.17 ± 1.72 months. Two patients showed a recurrence of tumor at 11 and 16 months, respectively. One underwent surgery, and the other patient was restarted with TMZ chemotherapy due to the tumor location with a highly possibility of surgical complications. The survival rate up to 1 year was 100%, and the other four patients are on observation without recurrence. None of the six patients had immediate or delayed BBBD-related complications. Conclusion: Multiple BBBDs can be regarded as a safe procedure without long-term complications, and it seems to have some survival benefits. However, since TMZ partially crosses the BBB, a further extended study with large numbers would be needed to evaluate the benefits of BBBD resulting in an increase of TMZ concentration. This study opened a new therapeutic strategy for GBM by combining BBBD with a larger molecular agent.

10.
J Neurosurg ; 134(2): 475-483, 2020 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-31899873

RESUMEN

OBJECTIVE: Glioblastoma (GBM) remains fatal due to the blood-brain barrier (BBB), which interferes with the delivery of chemotherapeutic agents. The purpose of this study was to evaluate the safety and feasibility of repeated disruption of the BBB (BBBD) with MR-guided focused ultrasound (MRgFUS) in patients with GBM during standard adjuvant temozolomide (TMZ) chemotherapy. METHODS: This study was a prospective, single-center, single-arm study. BBBD with MRgFUS was performed adjacent to the tumor resection margin on the 1st or 2nd day of the adjuvant TMZ chemotherapy at the same targets for 6 cycles. T2*-weighted/gradient echo (GRE) MRI was performed immediately after every sonication trial, and comprehensive MRI was performed at the completion of all sonication sessions. Radiological, laboratory, and clinical evaluations were performed 2 days before each planned BBBD. RESULTS: From September 2018, 6 patients underwent 145 BBBD trials at various locations in the brain. The authors observed gadolinium-enhancing spots at the site of BBBD on T1-weighted MRI in 131 trials (90.3%) and 93 trials (64.1%) showed similar spots on T2*-weighted/GRE MRI. When the 2 sequences were combined, BBBD was observed in 134 targets (92.4%). The spots disappeared on follow-up MRI. There were no imaging changes related to BBBD and no clinical adverse effects during the 6 cycles. CONCLUSIONS: This study is the first in which repetitive MRgFUS was performed at the same targets with a standard chemotherapy protocol for malignant brain tumor. BBBD with MRgFUS was performed accurately, repeatedly, and safely. Although a longer follow-up period is needed, this study allows for the possibility of other therapeutic agents that previously could not be used due to the BBB.Clinical trial registration no.: NCT03712293 (clinicaltrials.gov).

11.
J Korean Neurosurg Soc ; 62(6): 712-722, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31142101

RESUMEN

OBJECTIVE: Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics that contribute to optimal ultrasonic energy transmission for MRgFUS procedures. METHODS: For ex vivo skull experiments, various acoustic fields were measured under different conditions, using five non-embalmed cadaver skulls. For clinical skull analyses, brain computed tomography data of 46 patients who underwent MRgFUS ablations (18 unilateral thalamotomy, nine unilateral pallidotomy, and 19 bilateral capsulotomy) were retrospectively reviewed. Patients' skull factors and sonication parameters were comparatively analyzed with respect to the cadaveric skulls. RESULTS: Skull experiments identified three important factors related skull penetration of ultrasound, including skull density ratio (SDR), skull volume, and incidence angle of the acoustic rays against the skull surface. In clinical results, SDR and skull volume correlated with maximal temperature (Tmax) and energy requirement to achieve Tmax (p<0.05). In addition, considering the incidence angle determined by brain target location, less energy was required to reach Tmax in the central, rather than lateral targets particularly when compared between thalamotomy and capsulotomy (p<0.05). CONCLUSION: This study reconfirmed previously identified skull factors, including SDR and skull volume, for successful MRgFUS; it identified an additional factor, incidence angle of acoustic rays against the skull surface. To guarantee successful transcranial MRgFUS treatment without suffering these various skull issues, further technical improvements are required.

13.
Eur J Radiol ; 59(2): 149-56, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16716552

RESUMEN

MRI-guided and monitored focused ultrasound thermal surgery of brain through intact skull was tested in three rhesus monkeys. The aim of this study was to determine the amount of skull heating in an animal model with a head shape similar to that of a human. The ultrasound beam was generated by a 512 channel phased array system (Exablate 3000, InSightec, Haifa, Israel) that was integrated within a 1.5-T MR-scanner. The skin was pre-cooled by degassed temperature controlled water circulating between the array surface and the skin. Skull surface temperature was measured with invasive thermocouple probes. The results showed that by applying surface cooling the skin and skull surface can be protected, and that the brain surface temperature becomes the limiting factor. The MRI thermometry was shown to be useful in detecting the tissue temperature distribution next to the bone, and it should be used to monitor the brain surface temperature. The acoustic intensity values during the 20 s sonications were adequate for thermal ablation in the human brain provided that surface cooling is used.


Asunto(s)
Encéfalo/cirugía , Imagen por Resonancia Magnética , Terapia por Ultrasonido/métodos , Animales , Temperatura Corporal , Calor , Macaca mulatta , Modelos Animales , Termómetros , Terapia por Ultrasonido/instrumentación
14.
J Neurosurg ; 124(2): 411-6, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26361280

RESUMEN

OBJECTIVE: Magnetic resonance-guided focused ultrasound surgery (MRgFUS) was recently introduced as treatment for movement disorders such as essential tremor and advanced Parkinson's disease (PD). Although deep brain target lesions are successfully generated in most patients, the target area temperature fails to increase in some cases. The skull is one of the greatest barriers to ultrasonic energy transmission. The authors analyzed the skull-related factors that may have prevented an increase in target area temperatures in patients who underwent MRgFUS. METHODS: The authors retrospectively reviewed data from clinical trials that involved MRgFUS for essential tremor, idiopathic PD, and obsessive-compulsive disorder. Data from 25 patients were included. The relationships between the maximal temperature during treatment and other factors, including sex, age, skull area of the sonication field, number of elements used, skull volume of the sonication field, and skull density ratio (SDR), were determined. RESULTS: Among the various factors, skull volume and SDR exhibited relationships with the maximum temperature. Skull volume was negatively correlated with maximal temperature (p = 0.023, r(2) = 0.206, y = 64.156 - 0.028x, whereas SDR was positively correlated with maximal temperature (p = 0.009, r(2) = 0.263, y = 49.643 + 11.832x). The other factors correlate with the maximal temperature, although some factors showed a tendency to correlate. CONCLUSIONS: Some skull-related factors correlated with the maximal target area temperature. Although the number of patients in the present study was relatively small, the results offer information that could guide the selection of MRgFUS candidates.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Procedimientos Neuroquirúrgicos/métodos , Cráneo/diagnóstico por imagen , Cráneo/cirugía , Cirugía Asistida por Computador/métodos , Procedimientos Quirúrgicos Ultrasónicos/métodos , Adulto , Factores de Edad , Anciano , Temblor Esencial/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Trastorno Obsesivo Compulsivo/cirugía , Enfermedad de Parkinson/cirugía , Estudios Retrospectivos , Factores Sexuales , Técnicas Estereotáxicas , Temperatura , Núcleos Talámicos/anatomía & histología , Núcleos Talámicos/cirugía , Resultado del Tratamiento , Ultrasonografía , Adulto Joven
15.
J Ther Ultrasound ; 4: 4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26848391

RESUMEN

BACKGROUND: The study aims to investigate different ground plane segmentation designs of an ultrasound transducer to reduce gradient field induced eddy currents and the associated geometric distortion and temperature map errors in echo-planar imaging (EPI)-based MR thermometry in transcranial magnetic resonance (MR)-guided focused ultrasound (tcMRgFUS). METHODS: Six different ground plane segmentations were considered and the efficacy of each in suppressing eddy currents was investigated in silico and in operando. For the latter case, the segmented ground planes were implemented in a transducer mockup model for validation. Robust spoiled gradient (SPGR) echo sequences and multi-shot EPI sequences were acquired. For each sequence and pattern, geometric distortions were quantified in the magnitude images and expressed in millimeters. Phase images were used for extracting the temperature maps on the basis of the temperature-dependent proton resonance frequency shift phenomenon. The means, standard deviations, and signal-to-noise ratios (SNRs) were extracted and contrasted with the geometric distortions of all patterns. RESULTS: The geometric distortion analysis and temperature map evaluations showed that more than one pattern could be considered the best-performing transducer. In the sagittal plane, the star (d) (3.46 ± 2.33 mm) and star-ring patterns (f) (2.72 ± 2.8 mm) showed smaller geometric distortions than the currently available seven-segment sheet (c) (5.54 ± 4.21 mm) and were both comparable to the reference scenario (a) (2.77 ± 2.24 mm). Contrasting these results with the temperature maps revealed that (d) performs as well as (a) in SPGR and EPI. CONCLUSIONS: We demonstrated that segmenting the transducer ground plane into a star pattern reduces eddy currents to a level wherein multi-plane EPI for accurate MR thermometry in tcMRgFUS is feasible.

16.
Behav Brain Res ; 159(1): 27-36, 2005 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-15794994

RESUMEN

The behavior of Tristram's jird (a species of gerbil) in an illuminated open field resembled that of other rodents, comprising round trips to a home base and alternating between periods of progression (locomoting) and of stopping. In this study, we compared the characteristics of exploration in a dark arena with exploration by the same individuals in a lit arena. In the dark arena, stopping episodes were brief and fewer, suggesting almost continuous locomotion by the rodents. The clear distinction between progression and stopping that had characterized locomotion in an illuminated arena, thus diminished in the dark. There was also no apparent home base in the dark and traveling consisted in moving in a circular path, closing a loop to a recently traveled place that varied from one loop to the next. Locomotion in the dark may thus be regarded as a set of loops (round trips) to a continuously shifting home base, whereas with lights on the round trips converge to a home base using visible environmental landmarks. We suggest that a similar looping mechanism may be applicable to the behavior of hippocampal rats displaying hyperactivity and diversified locomotion, reminiscent of that seen in jirds in a dark arena.


Asunto(s)
Oscuridad , Conducta Exploratoria/fisiología , Fenómenos de Retorno al Lugar Habitual/fisiología , Orientación/fisiología , Conducta Espacial/fisiología , Animales , Conducta Exploratoria/efectos de la radiación , Gerbillinae , Fenómenos de Retorno al Lugar Habitual/efectos de la radiación , Luz , Locomoción/fisiología , Locomoción/efectos de la radiación , Masculino , Estadísticas no Paramétricas
17.
J Neurosurg ; 122(1): 162-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25343176

RESUMEN

OBJECT: The authors report different MRI patterns in patients with essential tremor (ET) or obsessive-compulsive disorder (OCD) after transcranial MR-guided focused ultrasound (MRgFUS) and discuss possible causes of occasional MRgFUS failure. METHODS: Between March 2012 and August 2013, MRgFUS was used to perform unilateral thalamotomy in 11 ET patients and bilateral anterior limb capsulotomy in 6 OCD patients; in all patients symptoms were refractory to drug therapy. Sequential MR images were obtained in patients across a 6-month follow-up period. RESULTS: For OCD patients, lesion size slowly increased and peaked 1 week after treatment, after which lesion size gradually decreased. For ET patients, lesions were visible immediately after treatment and markedly reduced in size as time passed. In 3 ET patients and 1 OCD patient, there was no or little temperature rise (i.e., < 52°C) during MRgFUS. Successful and failed patient groups showed differences in their ratio of cortical-to-bone marrow thickness (i.e., skull density). CONCLUSIONS: The authors found different MRI pattern evolution after MRgFUS for white matter and gray matter. Their results suggest that skull characteristics, such as low skull density, should be evaluated prior to MRgFUS to successfully achieve thermal rise.


Asunto(s)
Temblor Esencial/cirugía , Cápsula Interna/cirugía , Procedimientos Neuroquirúrgicos/métodos , Trastorno Obsesivo Compulsivo/cirugía , Cirugía Asistida por Computador/métodos , Núcleos Talámicos/cirugía , Procedimientos Quirúrgicos Ultrasónicos/métodos , Temblor Esencial/patología , Humanos , Cápsula Interna/patología , Imagen por Resonancia Magnética , Trastorno Obsesivo Compulsivo/patología , Cráneo/cirugía , Núcleos Talámicos/patología , Insuficiencia del Tratamiento
18.
J Ther Ultrasound ; 1: 17, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-25512336

RESUMEN

[This corrects the article on p. 3 in vol. 1, PMID: 24761224.].

19.
J Ther Ultrasound ; 1: 3, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24761224

RESUMEN

BACKGROUND: The purpose of this study was to describe targeting accuracy in functional neurosurgery using incisionless transcranial magnetic resonance (MR)-guided focused ultrasound technology. METHODS: MR examinations were performed before and 2 days after the ultrasound functional neurosurgical treatment to visualize the targets on T2-weighted images and determine their coordinates. Thirty consecutive targets were reconstructed: 18 were in the central lateral nucleus of the medial thalamus (central lateral thalamotomies against neurogenic pain), 1 in the centrum medianum thalamic nucleus (centrum medianum thalamotomy against essential tremor), 10 on the pallido-thalamic tract (pallido-thalamic tractotomies against Parkinson's disease), and 1 on the cerebello-thalamic tract (cerebello-thalamic tractotomy against essential tremor). We describe a method for reconstruction of the lesion coordinates on post-treatment MR images, which were compared with the desired atlas target coordinates. We also calculated the accuracy of the intra-operative target placement, thus allowing to determine the global, planning, and device accuracies. We also estimated the target lesion volume. RESULTS: We found mean absolute global targeting accuracies of 0.44 mm for the medio-lateral dimension (standard deviation 0.35 mm), 0.38 mm for the antero-posterior dimension (standard deviation 0.33 mm), and 0.66 mm for the dorso-ventral dimension (standard deviation 0.37 mm). Out of the 90 measured coordinates, 83 (92.2%) were inside the millimeter domain. The mean three-dimensional (3D) global accuracy was 0.99 mm (standard deviation 0.39 mm). The mean target volumes, reconstructed from surface measurements on 3D T1 series, were 68.5 mm(3) (standard deviation 39.7 mm(3)), and 68.9 mm(3) (standard deviation 40 mm(3)) using an ellipsoidal approximation. CONCLUSION: This study demonstrates a high accuracy of the MR-guided focused ultrasound technique. This high accuracy is due not only to the device qualities but also to the possibility for the operator to perform on-going real-time monitoring of the lesioning process. A precise method for determination of targeting accuracy is an essential component and basic requirement of the functional neurosurgical activity, allowing an on-going control of the performed therapeutic work indispensable for any target efficiency analysis and the maintenance of a low risk profile.

20.
J Ther Ultrasound ; 1: 18, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-25512862

RESUMEN

The goal was to test the effects of various combinations of pulse widths (PW) and duty cycles (DC) on high-intensity focused ultrasound (HIFU)-induced sonothrombolysis efficacy using an in vitro flow model. An ExAblate™ 4000 HIFU headsystem (InSightec, Inc., Israel) was used. Artificial blood clots were placed into test tubes inside a human calvarium and exposed to pulsatile flow. Four different duty cycles were tested against four different pulse widths. For all study groups, an increase in thrombolysis efficacy could be seen in association with increasing DC and/or PW (p < 0.0001). Using transcranial HIFU, significant thrombolysis can be achieved within seconds and without the use of lytic drugs in vitro. Longer duty cycles in combination with longer pulse widths seem to have the highest potential to optimize clot lysis efficacy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA