RESUMEN
BACKGROUND: The comparative efficacy of various anticoagulation strategies has not been clearly established in patients with acute myocardial infarction who are undergoing percutaneous coronary intervention (PCI) according to current practice, which includes the use of radial-artery access for PCI and administration of potent P2Y12 inhibitors without the planned use of glycoprotein IIb/IIIa inhibitors. METHODS: In this multicenter, randomized, registry-based, open-label clinical trial, we enrolled patients with either ST-segment elevation myocardial infarction (STEMI) or non-STEMI (NSTEMI) who were undergoing PCI and receiving treatment with a potent P2Y12 inhibitor (ticagrelor, prasugrel, or cangrelor) without the planned use of glycoprotein IIb/IIIa inhibitors. The patients were randomly assigned to receive bivalirudin or heparin during PCI, which was performed predominantly with the use of radial-artery access. The primary end point was a composite of death from any cause, myocardial infarction, or major bleeding during 180 days of follow-up. RESULTS: A total of 6006 patients (3005 with STEMI and 3001 with NSTEMI) were enrolled in the trial. At 180 days, a primary end-point event had occurred in 12.3% of the patients (369 of 3004) in the bivalirudin group and in 12.8% (383 of 3002) in the heparin group (hazard ratio, 0.96; 95% confidence interval [CI], 0.83 to 1.10; P=0.54). The results were consistent between patients with STEMI and those with NSTEMI and across other major subgroups. Myocardial infarction occurred in 2.0% of the patients in the bivalirudin group and in 2.4% in the heparin group (hazard ratio, 0.84; 95% CI, 0.60 to 1.19; P=0.33), major bleeding in 8.6% and 8.6%, respectively (hazard ratio, 1.00; 95% CI, 0.84 to 1.19; P=0.98), definite stent thrombosis in 0.4% and 0.7%, respectively (hazard ratio, 0.54; 95% CI, 0.27 to 1.10; P=0.09), and death in 2.9% and 2.8%, respectively (hazard ratio, 1.05; 95% CI, 0.78 to 1.41; P=0.76). CONCLUSIONS: Among patients undergoing PCI for myocardial infarction, the rate of the composite of death from any cause, myocardial infarction, or major bleeding was not lower among those who received bivalirudin than among those who received heparin monotherapy. (Funded by the Swedish Heart-Lung Foundation and others; VALIDATE-SWEDEHEART ClinicalTrialsRegister.eu number, 2012-005260-10 ; ClinicalTrials.gov number, NCT02311231 .).
Asunto(s)
Anticoagulantes/uso terapéutico , Heparina/uso terapéutico , Infarto del Miocardio/tratamiento farmacológico , Fragmentos de Péptidos/uso terapéutico , Intervención Coronaria Percutánea , Anciano , Anticoagulantes/efectos adversos , Terapia Combinada , Femenino , Hemorragia/inducido químicamente , Heparina/administración & dosificación , Hirudinas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/terapia , Fragmentos de Péptidos/efectos adversos , Antagonistas del Receptor Purinérgico P2Y/uso terapéutico , Proteínas Recombinantes/efectos adversos , Proteínas Recombinantes/uso terapéuticoRESUMEN
BACKGROUND: The registry-based randomized VALIDATE-SWEDEHEART trial (NCT02311231) compared bivalirudin vs. heparin in patients undergoing percutaneous coronary intervention (PCI) for myocardial infarction (MI). It showed no difference in the composite primary endpoint of death, MI, or major bleeding at 180 days. Here, we report outcomes at two years. METHODS: Analysis of primary and secondary endpoints at two years of follow-up was prespecified in the study protocol. We report the study results for the extended follow-up time here. RESULTS: In total, 6006 patients were enrolled, 3005 with ST-segment elevation MI (STEMI) and 3001 with Non-STEMI (NSTEMI), representing 70 % of all eligible patients with these diagnoses during the study. The primary endpoint occurred in 14.0 % (421 of 3004) in the bivalirudin group compared with 14.3 % (429 of 3002) in the heparin group (hazard ratio [HR] 0.97; 95 % confidence interval [CI], 0.85-1.11; P = 0.70) at one year and in 16.7 % (503 of 3004) compared with 17.1 % (514 of 3002), (HR 0.97; 95 % CI, 0.96-1.10; P = 0.66) at two years. The results were consistent in patients with STEMI and NSTEMI and across major subgroups. CONCLUSIONS: Until the two-year follow-up, there were no differences in endpoints between patients with MI undergoing PCI and allocated to bivalirudin compared with those allocated to heparin. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02311231.
Asunto(s)
Anticoagulantes , Antitrombinas , Hemorragia , Heparina , Hirudinas , Infarto del Miocardio sin Elevación del ST , Fragmentos de Péptidos , Intervención Coronaria Percutánea , Proteínas Recombinantes , Sistema de Registros , Infarto del Miocardio con Elevación del ST , Humanos , Hirudinas/efectos adversos , Hirudinas/administración & dosificación , Heparina/efectos adversos , Heparina/uso terapéutico , Heparina/administración & dosificación , Fragmentos de Péptidos/uso terapéutico , Fragmentos de Péptidos/efectos adversos , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/diagnóstico , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Proteínas Recombinantes/uso terapéutico , Proteínas Recombinantes/efectos adversos , Proteínas Recombinantes/administración & dosificación , Masculino , Resultado del Tratamiento , Femenino , Factores de Tiempo , Anciano , Persona de Mediana Edad , Antitrombinas/efectos adversos , Antitrombinas/uso terapéutico , Antitrombinas/administración & dosificación , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Hemorragia/inducido químicamente , Infarto del Miocardio sin Elevación del ST/terapia , Infarto del Miocardio sin Elevación del ST/mortalidad , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Factores de Riesgo , SueciaRESUMEN
AIMS: Our aim was to evaluate the two-year clinical results of a new sirolimus-eluting stent (MiStent SES) with a bioabsorbable coating designed for rapid polymer dissolution but sustained drug delivery. METHODS AND RESULTS: Major adverse cardiac events (MACE), target lesion failure (TLF), target vessel failure (TVF), and stent thrombosis (ST) at two-year follow-up are reported for the DESSOLVE I and II trials. In DESSOLVE I, the MiStent SES (n=29) demonstrated a 3.4% two-year MACE rate without TLF or TVF. In DESSOLVE II, the MiStent group had a 6.7% (8/120) two-year MACE rate compared to 13.3% (8/60) for Endeavor (p=0.167). TLF was 5.0% in the MiStent and Endeavor groups (p=1.00). TVF was 5.0% for MiStent versus 11.7% for Endeavor (p=0.129). No probable or definite ST was reported with the MiStent up to two years. The median duration of dual antiplatelet therapy (DAPT) in DESSOLVE I and II was 364 and 366 days, respectively. CONCLUSIONS: The MiStent SES demonstrated good long-term safety and effectiveness with low two-year MACE, TLF, and TVF rates.
Asunto(s)
Implantes Absorbibles , Stents Liberadores de Fármacos , Sirolimus/uso terapéutico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Polímeros/administración & dosificación , Polímeros/uso terapéutico , Sirolimus/administración & dosificación , Solubilidad , Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Injury incurred while saphenous veins are being obtained results in poor graft patency and impairs the results of coronary artery bypass grafting. A novel method of obtaining veins, the no-touch technique, has shown improved long-term saphenous vein graft patency. METHODS: This randomized trial included 108 patients undergoing coronary artery bypass grafting and compared the patency of no-touch saphenous vein with that of radial artery grafts. Each patient was assigned to receive one no-touch saphenous vein and one radial artery graft to either the left or the right coronary territory to complement the left internal thoracic artery. RESULTS: Angiography was performed in 99 patients (92%) at a mean of 36 months postoperatively. Graft and grafted coronary artery patency was evaluated. The patency of grafts for no-touch saphenous vein and radial artery was 94% versus 82% (p = 0.01), respectively. The patency of coronary arteries grafted with no-touch saphenous vein and radial artery grafts was 95% versus 84% (p = 0.005), respectively. Eighty-nine of 96 (93%) left internal thoracic artery grafts were patent. CONCLUSIONS: No-touch saphenous vein grafts showed a significantly higher patency rate than the radial artery grafts and the patency was comparable to the patency for left internal thoracic artery grafts. This highlights the improvement in saphenous vein graft quality with the no-touch technique and increases the number of situations in which saphenous veins may be preferable to radial artery grafts as conduits in coronary artery bypass grafting.
Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Arteria Radial/trasplante , Vena Safena/trasplante , Grado de Desobstrucción Vascular , Adulto , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Arterias Mamarias/fisiopatología , Arterias Mamarias/trasplante , Persona de Mediana Edad , Arteria Radial/fisiopatología , Estudios Retrospectivos , Vena Safena/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía DopplerRESUMEN
A 73-year-old woman with severe aortic stenosis was accepted for transcatheter aortic valve implantation. There was minimal paravalvular leakage after the implantation, and the patient was stable. Twelve minutes after the implantation, the arterial pressure suddenly dropped. Transesophageal echocardiography showed severe left ventricular dysfunction. Cardiopulmonary resuscitation was started, and initially was successful with a systolic blood pressure of 90 mm Hg. However, despite initiation of extracorporeal circulation support, the patient deteriorated, pulmonary edema developed, and she died. Autopsy revealed an inverted aortic valve. The reasons why the patient had cardiac arrest and an inverted transfemoral aortic valve remain unclear.