Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Sensors (Basel) ; 22(1)2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-35009930

RESUMEN

Nitric oxide (NO) is a toxic gas, which is dangerous for human health and causes many respiratory infections, poisoning, and lung damage. In this work, we have successfully grown ZnO nanorod film on annealed ZnO seed layer in different ambient temperatures, and the morphology of the nanorods sensing layer that affects the gas sensing response to nitric oxide (NO) gas were investigated. To acknowledge the effect of annealing treatment, the devices were fabricated with annealed seed layers in air and argon ambient at 300 °C and 500 °C for 1 h. To simulate a vertical device structure, a silver nanowire electrode covered in ZnO nanorod film was placed onto the hydrothermal grown ZnO nanorod film. We found that annealing treatment changes the seed layer's grain size and defect concentration and is responsible for this phenomenon. The I-V and gas sensing characteristics were dependent on the oxygen defects concentration and porosity of nanorods to react with the target gas. The resulting as-deposited ZnO seed layer shows better sensing response than that annealed in an air and argon environment due to the nanorod morphology and variation in oxygen defect concentration. At room temperature, the devices show good sensing response to NO concentration of 10 ppb and up to 100 ppb. Shortly, these results can be beneficial in the NO breath detection for patients with chronic inflammatory airway disease, such as asthma.


Asunto(s)
Nanotubos , Óxido de Zinc , Electrodos , Humanos , Óxido Nítrico , Plata
2.
Sensors (Basel) ; 21(17)2021 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-34502673

RESUMEN

In this research work, the gas sensing properties of halogenated chloroaluminum phthalocyanine (ClAlPc) thin films were studied at room temperature. We fabricated an air-stable ClAlPc gas sensor based on a vertical organic diode (VOD) with a porous top electrode by the solution process method. The surface morphology of the solution-processed ClAlPc thin film was examined by field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM). The proposed ClAlPc-based VOD sensor can detect ammonia (NH3) gas at the ppb level (100~1000 ppb) at room temperature. Additionally, the ClAlPc sensor was highly selective towards NH3 gas compared to other interfering gases (NO2, ACE, NO, H2S, and CO). In addition, the device lifetime was tested by storing the device at ambient conditions. The effect of relative humidity (RH) on the ClAlPc NH3 gas sensor was also explored. The aim of this study is to extend these findings on halogenated phthalocyanine-based materials to practical electronic nose applications in the future.

3.
Nanotechnology ; 30(9): 095501, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30537687

RESUMEN

We successfully demonstrated a simple and low-cost nitric oxide (NO) gas sensor to deliver parts-per-billion (ppb) regime detection at room temperature operation. A vertical-channel ZnO nanorods resistor is fabricated by putting silver nanowire electrode onto the hydrothermal ZnO nanorods film. With suitable process condition, the nanorods film exhibits a uniform morphology to enable the formation of gas-permeable nanowire top electrode while also the nanorods provide good surface-to-volume ratio to deliver strong reaction with NO gas. A detection limit to 10 ppb NO is observed while the sensing dynamic range from 10 ppb to 100 ppb is obtained. The sensor is reversible and the real-time sensing response is within 30 s. The results benefit the NO breath detection for patients with chronic inflammatory airway disease, such as asthma.

4.
Opt Express ; 24(2): A414-23, 2016 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-26832593

RESUMEN

In this work, we investigate blade-coated organic interlayers at the rear surface of hybrid organic-silicon photovoltaics based on two small molecules: Tris(8-hydroxyquinolinato) aluminium (Alq(3)) and 1,3-bis(2-(4-tert-butylphenyl)-1,3,4-oxadiazol-5-yl) benzene (OXD-7). In particular, soluble Alq(3) resulting in a uniform thin film with a root-mean-square roughness < 0.2nm is demonstrated for the first time. Both devices with the Alq(3) and OXD-7 interlayers show notable enhancement in the open-circuit voltage and fill-factor, leading to a net efficiency increase by over 2% from the reference, up to 11.8% and 12.5% respectively. The capacitance-voltage characteristics confirm the role of the small-molecule interlayers resembling a thin interfacial oxide layer for the Al-Si Schottky barrier to enhance the built-in potential and facilitate charge transport. Moreover, the Alq(3) interlayer in optimized devices exhibits isolated phases with a large surface roughness, in contrast to the OXD-7 which forms a continuous uniform thin film. The distinct morphological differences between the two interlayers further suggest different enhancement mechanisms and hence offer versatile functionalities to the advent of hybrid organic-silicon photovoltaics.

5.
Sensors (Basel) ; 14(9): 16287-95, 2014 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-25184492

RESUMEN

In this study, we investigate the keys to obtain a sensitive ammonia sensor with high air stability by using a low-cost polythiophene diode with a vertical channel and a porous top electrode. Poly(3-hexylthiophene) (P3HT) and air-stable poly(5,5'-bis(3-dodecyl-2-thienyl)-2,2'-bithiophene) (PQT-12) are both evaluated as the active sensing layer. Two-dimensional current simulation reveals that the proposed device exhibits numerous connected vertical nanometer junctions (VNJ). Due to the de-doping reaction between ammonia molecules and the bulk current flowing through the vertical channel, both PQT-12 and P3HT VNJ-diodes exhibit detection limits of 50-ppb ammonia. The P3HT VNJ-diode, however, becomes unstable after being stored in air for two days. On the contrary, the PQT-12 VNJ-diode keeps an almost unchanged response to 50-ppb ammonia after being stored in air for 25 days. The improved storage lifetime of an organic-semiconductor-based gas sensor in air is successfully demonstrated.


Asunto(s)
Amoníaco/análisis , Conductometría/instrumentación , Gases/análisis , Compuestos de Organoselenio/química , Semiconductores , Tiofenos/química , Diseño de Equipo , Análisis de Falla de Equipo , Transductores
6.
ACS Sens ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38754006

RESUMEN

Although semiconductor metal oxide-based sensors are promising for gas sensing, low-power and room temperature operation (24 ± 1 °C) remains desirable for practical applications particularly considering the request of energy saving or net zero emission. In this study, we demonstrate a Au/SnO2-based ultrasensitive H2S gas sensor with a limit of detection (LOD) of 2 ppb, operating at very low voltages (0.05 to 0.5 V) at room temperature. The Au/SnO2-based sensor showed approximately 7 times higher response (the ratio of change in the current to initial current) of ∼270% and 4 times faster recovery (126 s) compared to the pure SnO2-based sensor when exposed to 500 ppb H2S gas concentration at 0.5 V operating voltage at relative humidity (RH) 17.5 ± 2.5%. The enhancement can be attributed to the catalytic characteristics of AuNPs, increasing the number of adsorbed oxygen species on sensing material surfaces. Additionally, AuNPs aid in forming flower-petal-like Au/SnO2 nanostructures, offering a larger surface area and more active sites for H2S sensing. Moreover, at low voltage (<1 V), the localized dipoles at the Au/SnO2 interface may further enhance the absorption of polar oxygen molecules and hence promote the reaction between H2S and oxygen species. This low-power, ultrasensitive H2S sensor outperforms high-powered alternatives, making it ideal for environmental, food safety, and healthcare applications.

7.
Discov Nano ; 19(1): 102, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38869646

RESUMEN

In this study, a 3 × 3 blue micro-LED array with a pixel size of 10 × 10 µm2 and a pitch of 15 µm was fabricated on an epilayer grown on a sapphire substrate using metalorganic chemical vapor deposition technology. The fabrication process involved photolithography, wet and dry etching, E-beam evaporation, and ion implantation technology. Arsenic multi-energy implantation was utilized to replace the mesa etching for electrical isolation, where the implantation depth increased with the average energy. Different ion depth profiles had varying effects on electrical properties, such as forward current and leakage currents, potentially causing damage to the n-GaN layer and increasing the series resistance of the LEDs. As the implantation depth increased, the light output power and peak external quantum efficiency of the LEDs also increased, improving from 5.33 to 9.82%. However, the efficiency droop also increased from 46.3 to 48.6%.

8.
Anal Chem ; 85(6): 3110-7, 2013 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-23394145

RESUMEN

We successfully demonstrate the first solid-state sensor to have reliable responses to breath ammonia of rat. For thioacetamide (TAA)-induced hepatopathy rats, we observe that the proposed sensor can detect liver that undergoes acute-moderate hepatopathy with a p-value less than 0.05. The proposed sensor is an organic diode with vertical nanojunctions produced by using low-cost colloidal lithography. Its simple structure and low production cost facilitates the development of point-of-care technology. We also anticipate that the study is a starting point for investigating sophisticated breath-ammonia-related disease models.


Asunto(s)
Amoníaco/química , Enfermedad Hepática Inducida por Sustancias y Drogas/diagnóstico , Nanoestructuras , Animales , Pruebas Respiratorias/métodos , Enfermedad Hepática Inducida por Sustancias y Drogas/metabolismo , Femenino , Ratas , Ratas Sprague-Dawley , Tioacetamida/toxicidad
9.
Biosensors (Basel) ; 13(1)2023 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-36671916

RESUMEN

Developing ultraflexible sensors using metal oxides is challenging due to the high-temperature annealing step in the fabrication process. Here, we demonstrate the ultraflexible relative humidity (RH) sensor on food plastic wrap by using 808 nm near-infrared (NIR) laser annealing for 1 min at a low temperature (26.2-40.8 °C). The wettability of plastic wraps coated with sol-gel solution is modulated to obtain uniform films. The surface morphology, local temperature, and electrical properties of the SnO2 resistor under NIR laser irradiation with a power of 16, 33, and 84 W/cm2 are investigated. The optimal device can detect wide-range RH from 15% to 70% with small incremental changes (0.1-2.2%). X-ray photoelectron spectroscopy reveals the relation between the surface binding condition and sensing response. Finally, the proposed sensor is attached onto the face mask to analyze the real-time human breath pattern in slow, normal, and fast modes, showing potential in wearable electronics or respiration monitoring.


Asunto(s)
Electrónica , Óxidos , Humanos , Humedad , Monitoreo Fisiológico , Plásticos
10.
Nanoscale Res Lett ; 17(1): 113, 2022 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-36437416

RESUMEN

In this study, the effect of ITO contact ratio for blue light micro-light-emitting diode (µLED) with dimensions 40 µm × 40 µm was assessed. The contact ratio from 0.2 to 0.8 was designed for the ratio of electrode area to light-emitting area. As the contact ratio increased from 0.2 to 0.8, the turn-on voltage of µLED decreased. It could be due to the short lateral diffusion length in multiple quantum wells (MQW) and lower parallel resistance for the µLED with a large contact ratio. The leakage currents of single µLED were below 5.1 × 10-9 A, no matter the contact ratio. It means that the contact ratio does not affect the leakage current as measured on single chip. Moreover, µLED array with a 0.8 contact ratio presented the highest output power than other samples (5.25 mW as the current density of 1875 A/cm2). It could attribute to the MQWs usage, the metal contact reflective behavior and less current crowding, which generated more carriers and extracted more lighting from the µLED. The simulation data using SpeCLED software agreed well with these experiments, and µLED with a 0.8 contact ratio showed the best optoelectronic properties.

11.
Polymers (Basel) ; 14(22)2022 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-36433157

RESUMEN

Bio-inspired materials have received significant interest in the development of flexible electronics due to their natural grid structures, especially natural leaf vein networks. In this work, a bio-inspired leaf vein-based flexible humidity sensor is demonstrated. The proposed sensor is composed of a leaf/Al/glycerin/Ag paste. The Al-deposited leaf vein networks are used as a bottom electrode with a resistance of around 100 Ω. The humidity sensor responds well to relative humidity (RH) levels ranging from 15% to 70% at room temperature. The fabricated humidity sensor exhibits an ultra-sensitive response to different humidity conditions due to the biodegradable insulating hygroscopic polymer (glycerin), specifically the ionic conductivity reaction. To further verify the presence of ionic conduction, the device performance is tested by doping NaCl salt into the hygroscopic polymer sensing layer. In addition, both the repeatability and flexibility of the sensor are tested under different bending angles (0°, 90°, 180°, and 360°). The bioinspired ultrasensitive humidity sensor with a biocompatible and biodegradable sensing layer holds great potential, especially for health care applications (e.g., respiratory monitoring) without causing any body harm.

12.
Anal Chim Acta ; 1206: 339729, 2022 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-35473878

RESUMEN

In this work, we proposed a rapid and easy check of the drinking water pollution level due to bacteria growth by semiconductor gas sensor. Highly sensitive vertical channel organic ammonia gas sensor was used to detect the gases emitted from the polluted water, and then determined effective ammonia concentration according to its response. Residues from meat of fish, shrimp, and fruits were mashed and added to the clean water. The water samples were stored at 35 °C for natural decay. Initially the bacteria concentration was below 100 colony forming unit per ml (cfu/ml), then it increased to103 cfu/ml in 2 h and 105 cfu/ml in 4 h, which was beyond the drinking safety standard, 500 cfu/ml. At this gas level no bad odor can be sensed by human yet, however, the effective ammonia concentration of those samples rises to 300-500 ppb in 2 h. The amine gas sensor can therefore be used as a rapid check if the bacteria level inside the water is far over the safety standard.


Asunto(s)
Agua Potable , Amoníaco , Bacterias , Agua Potable/microbiología , Gases , Semiconductores , Microbiología del Agua
13.
Nanoscale Res Lett ; 16(1): 45, 2021 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-33704602

RESUMEN

We report response of photoluminescence (PL) from GaN nanowires without protection in solutions. The distinct response is not only toward pH but toward ionic concentration under same pH. The nanowires appear to be highly stable under aqueous solution with high ionic concentration and low pH value down to 1. We show that the PL has a reversible interaction with various types of acidic and salt solutions. The quantum states of nanowires are exposed to the external environment and have a direct physical interaction which depends on the anions of the acids. As the ionic concentration increases, the PL intensity goes up or down depending on the chemical species. The response results from a competition of change in surface band bending and charge transfer to redox level in solution. That of GaN films is reported for comparison as the effect of surface band bending can be neglected so that there are only slight variations in PL intensity for GaN films. Additionally, such physical interaction does not impact on the PL peaks in acids and salts, whereas there is a red shift on PL when the nanowires are in basic solution, say NH4OH, due to chemical etching occurred on the nanowires.

14.
ACS Appl Mater Interfaces ; 13(41): 49279-49287, 2021 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-34613692

RESUMEN

Near-infrared (NIR) laser annealing is used to write conductive patterns on the surface of polypropylene/multi-walled carbon nanotube nanocomposite (PP/MWCNT) plates. Before irradiation, the surface of the nanocomposite is not conductive due to the partial alignment of the MWCNT, which occurs during injection molding. We observe a significant decrease in the surface sheet resistance using NIR laser irradiation, which we explain by a randomization of the orientation of MWCNTs in the PP matrix melt by NIR laser irradiation. After only 5 s of irradiation, the sheet resistance of PP/MWCNTs, annealed with a laser at a power density of 7 W/cm2, decreases by more than 4 decades from ∼100 MΩ/sq to ∼1 kΩ/sq. Polarized Raman, TEM, and SEM are used to investigate the changes in the sheet resistance and confirm the physico-chemical processes involved. This allows direct writing of conductive patterns using a NIR laser on the surface of nanocomposite polymer substrates, with the advantages of a fast, easy, and low-energy consumption process.

15.
Biomedicines ; 8(11)2020 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-33142890

RESUMEN

Chronic kidney disease (CKD) is a public health problem and its prevalence has increased worldwide; patients are commonly unaware of the condition. The present study aimed to investigate whether exhaled breath ammonia via vertical-channel organic semiconductor (V-OSC) sensor measurement could be used for rapid CKD screening. We enrolled 121 CKD stage 1-5 patients, including 19 stage 1 patients, 26 stage 2 patients, 38 stage 3 patients, 21 stage 4 patients, and 17 stage 5 patients, from July 2019 to January 2020. Demographic and laboratory data were recorded. The exhaled ammonia was collected and rapidly measured by the V-OSC sensor to correlate with kidney function. Results showed no significant difference in age, sex, body weight, hemoglobin, albumin level, and comorbidities in different CKD stage patients. Correlation analysis demonstrated a good correlation between breath ammonia and blood urea nitrogen levels, serum creatinine levels, and estimated glomerular filtration rate (eGFR). Breath ammonia concentration was significantly elevated with increased CKD stage compared with the previous stage (CKD stage 1/2/3/4/5: 636 ± 94; 1020 ± 120; 1943 ± 326; 4421 ± 1042; 12781 ± 1807 ppb, p < 0.05). The receiver operating characteristic curve analysis showed an area under the curve (AUC) of 0.835 (p < 0.0001) for distinguishing CKD stage 1 from other CKD stages at 974 ppb (sensitivity, 69%; specificity, 95%). The AUC was 0.831 (p < 0.0001) for distinguishing between patients with/without eGFR < 60 mL/min/1.73 m2 (cutoff 1187 ppb: sensitivity, 71%; specificity, 78%). At 886 ppb, the sensitivity increased to 80% but the specificity decreased to 69%. This value is suitable for kidney function screening. Breath ammonia detection with V-OSC is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy.

16.
RSC Adv ; 10(48): 28766-28777, 2020 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35520068

RESUMEN

Improving the stability of large-area organic light-emitting diodes is very important for practical applications. The interfacial layer plays a crucial role to improve the electron injection characteristic. In this work, devices prepared by various solution-processed interfacial materials and thermal-evaporated CsF were compared. In the devices with active area of 2.25 mm × 2.25 mm, we found that the performance and lifetime of the device with solution-processed Liq interfacial layer was comparable with the device with thermal-evaporated CsF. However, for the devices with active area of 2.4 cm × 3.7 cm, the device based on thermal-evaporated CsF was the champion in both performance and lifetime. The influence of the thickness of CsF on the stability was investigated. The most stable blue fluorescent devices can be achieved when the thickness of CsF is about 0.1 nm, while the most stable green phosphorescent devices can be obtained by depositing 0.2 nm CsF. The best current efficiency for the blue fluorescent device is 4 cd A-1, while the best one for the green phosphorescent device is 22 cd A-1. Furthermore, burning points causing the failure of the devices were investigated by scanning electron microscopy, atomic force microscopy, thermography and secondary ion mass spectrometry. We demonstrated that burning points are defects, which can be observed after long-time operation, showing higher local temperature and fragmentary electrode.

17.
J Breath Res ; 14(3): 036002, 2020 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-32015218

RESUMEN

Previous studies have shown that breath ammonia (breath-NH3) concentration is associated with blood urea nitrogen (BUN) levels. However, interindividual variations in breath-NH3 concentrations were observed. Thus, the present study aimed to assess the effect of oral cavity conditions on breath-NH3 concentration and to validate whether the measurement of breath-NH3 concentration is feasible in clinical settings. A total of 125 individuals, including patients with stage 3 to 5 chronic kidney disease (CKD3-5), those on dialysis, and healthy participants, were recruited. A nanostructured sensor was used to detect breath-NH3 concentrations. Pre- and post-gargling as well as pre- and post-hemodialysis (HD) breath-NH3, salivary pH, and salivary urea levels were measured. Breath-NH3, salivary urea, salivary pH, and BUN levels were positively correlated to each other. Breath-NH3 concentrations were associated with BUN levels (r = 0.43, p < 0.001) and were significantly higher in CKD3-5 (p < 0.005) and dialysis patients (p < 0.001) than in healthy participants. Higher correlation coefficients were noted between breath-NH3 concentrations and BUN levels during follow-up (r = 0.59-0.94, p < 0.05). When the cutoff value of breath-NH3 was set at 523.65 ppb, its sensitivity and specificity in predicting CKD (BUN level >24 mg dl-1) were 87.6% and 80.9%, respectively. Breath-NH3 concentrations decreased after HD (p < 0.001) and immediately after gargling (p < 0.01). Breath-NH3 concentration, which was affected by gargling, was correlated to BUN level. The measurement of breath-NH3 concentration using the nanostructured device may be used as a tool for CKD detection and personalized point-of-care for CKD and dialysis patients. The current study had a small sample size. Thus, further studies with a larger cohort must be conducted to validate the effect of oral factors on breath-NH3 concentration and to validate the benefit of breath-NH3 measurement.


Asunto(s)
Amoníaco/análisis , Nitrógeno de la Urea Sanguínea , Pruebas Respiratorias/métodos , Diálisis Renal , Insuficiencia Renal Crónica/sangre , Adulto , Pruebas Respiratorias/instrumentación , Femenino , Humanos , Concentración de Iones de Hidrógeno , Masculino , Persona de Mediana Edad , Curva ROC , Insuficiencia Renal Crónica/diagnóstico , Saliva/química , Urea/análisis
18.
ACS Omega ; 5(36): 23021-23027, 2020 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-32954152

RESUMEN

A fine cylindrical chemical sensor tip is developed with optical fiber in the core, surrounded by a transparent cylinder of photopolymer Norland Optical Adhesive 61 (NOA 61), and covered by a polymer hydrogel mixed with sensing molecules. The overall diameter is as small as 1.5 mm. pH response is demonstrated using two approaches of sensing materials: (i) absorbing probe Phenol Red mixed with Rhodamine 6G fluorescent dye and (ii) 8-hydroxypyrene-1,3,6-trisulfonic acid fluorescent probe. Both the optical excitation and fluorescence signal collection are through the optical fibers. A time resolution of 10 s is achieved for pH variations. Good linearity is observed in the physiological range from pH 7.0 to pH 8.6 with reversible and reproducible outcomes. For in vitro urea measurement, the sensor tip can distinguish 1, 3, and 5 mM urea solution, which is a crucial range in saliva urea concentration. The miniaturized tip with such simple cylindrical symmetry is designed to detect vital signs during minimally invasive surgeries and can be potentially accompanied with endoscopes to enter human bodies.

19.
ACS Appl Mater Interfaces ; 12(22): 24984-24991, 2020 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-32367710

RESUMEN

A metal-oxide material (indium zinc oxide [IZO]) device with near-infrared (NIR) laser annealing was demonstrated on both glass and bendable plastic substrates (polycarbonate, polyethylene, and polyethylene terephthalate). After only 60 s, the sheet resistance of IZO films annealed with a laser was comparable to that of thermal-annealed devices at temperatures in the range of 200-300 °C (1 h). XPS, ATR, and AFM were used to investigate the changes in the sheet resistance and correlate them to the composition and morphology of the thin film. Finally, the NIR-laser-annealed IZO films were demonstrated to be capable of detecting changes in humidity and serving as a highly sensitive gas sensor of hydrogen sulfide (in ppb concentration), with room-temperature operation on a bendable substrate.

20.
Biosens Bioelectron ; 162: 112230, 2020 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-32392152

RESUMEN

Solid-state zinc ion sensor is developed with high enough resolution and reproducibility for the potential application in brain injury monitoring. An optical diffuser is incorporated into the zinc ion sensor based on optical fiber and hydrogel doped with the fluorescent zinc ion probe molecule meso-2,6-Dichlorophenyltripyrrinone (TPN-Cl2). The diffuser transforms the high-peak-intensity excitation light near the fiber end into a broad light with moderate local intensity to reduce the degradation of the probe molecule. Reversible detection can be reached for 1, 2, and 5 µM (10-6 Molar), with slopes 0.3, 0.6, and 0.8 respectively. This is the pathophysiological concentration range after brain injury. The sensor is applied to neuron-glial cultures and macrophage under the stimulation of lipopolysaccharide (LPS), KCl and oxygen/glucose deprivation (OGD) that reflect inflammation, depolarization and ischemia respectively, mimicking events after brain injury. The zinc ion level is raised to 4-5 µM after LPS treatment, and then reduced to <3 µM after the co-treatment with the herbal drug silymarin. The results suggest the conditions of the neural cells under stress can be monitored.


Asunto(s)
Técnicas Biosensibles/métodos , Colorantes Fluorescentes/química , Hidrogeles/química , Neuronas/citología , Zinc/análisis , Animales , Células Cultivadas , Neuroglía/química , Neuroglía/citología , Neuronas/química , Fibras Ópticas , Ratas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA