Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(3): 440-450, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38282445

RESUMEN

INTRODUCTION: During atrial fibrillation ablation (AFA), achievement of first pass isolation (FPI) reflects effective lesion formation and predicts long-term freedom from arrhythmia recurrence. We aim to determine the clinical and procedural predictors of pulmonary vein FPI. METHODS: We reviewed AFA procedures in a multicenter prospective registry of AFA (REAL-AF). A multivariate ordinal logistic regression, weighted by inverse proceduralist volume, was used to determine predictors of FPI. RESULTS: A total of 2671 patients were included with 1806 achieving FPI in both vein sides, 702 achieving FPI in one, and 163 having no FPI. Individually, age, left atrial (LA) scar, higher power usage (50 W), greater posterior contact force, ablation index >350 posteriorly, Vizigo™ sheath utilization, nonstandard ventilation, and high operator volume (>6 monthly cases) were all related to improved odds of FPI. Conversely sleep apnea, elevated body mass index (BMI), diabetes mellitus, LA enlargement, antiarrhythmic drug use, and center's higher fluoroscopy use were related to reduced odds of FPI. Multivariate analysis showed that BMI > 30 (OR 0.78 [0.64-0.96]) and LA volume (OR per mL increase = 1.00 [0.99-1.00]) predicted lower odds of achieving FPI, whereas significant left atrial scarring (>20%) was related to higher rates of FPI. Procedurally, the use of high power (50 W) (OR 1.32 [1.05-1.65]), increasing force posteriorly (OR 2.03 [1.19-3.46]), and nonstandard ventilation (OR 1.26 [1.00-1.59]) predicted higher FPI rates. At a site level, high procedural volume (OR 1.89 [1.48-2.41]) and low fluoroscopy centers (OR 0.72 [0.61-0.84]) had higher rates of FPI. CONCLUSION: FPI rates are affected by operator experience, patient comorbidities, and procedural strategies. These factors may be postulated to impact acute lesion formation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Estudios Prospectivos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Cicatriz , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Estudios Multicéntricos como Asunto
2.
Artículo en Inglés | MEDLINE | ID: mdl-38924224

RESUMEN

INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.

3.
JAMA ; 331(7): 601-610, 2024 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-38497695

RESUMEN

Importance: Paroxysmal supraventricular tachycardia (PSVT), defined as tachyarrhythmias that originate from or conduct through the atria or atrioventricular node with abrupt onset, affects 168 to 332 per 100 000 individuals. Untreated PSVT is associated with adverse outcomes including high symptom burden and tachycardia-mediated cardiomyopathy. Observations: Approximately 50% of patients with PSVT are aged 45 to 64 years and 67.5% are female. Most common symptoms include palpitations (86%), chest discomfort (47%), and dyspnea (38%). Patients may rarely develop tachycardia-mediated cardiomyopathy (1%) due to PSVT. Diagnosis is made on electrocardiogram during an arrhythmic event or using ambulatory monitoring. First-line acute therapy for hemodynamically stable patients includes vagal maneuvers such as the modified Valsalva maneuver (43% effective) and intravenous adenosine (91% effective). Emergent cardioversion is recommended for patients who are hemodynamically unstable. Catheter ablation is safe, highly effective, and recommended as first-line therapy to prevent recurrence of PSVT. Meta-analysis of observational studies shows single catheter ablation procedure success rates of 94.3% to 98.5%. Evidence is limited for the effectiveness of long-term pharmacotherapy to prevent PSVT. Nonetheless, guidelines recommend therapies including calcium channel blockers, ß-blockers, and antiarrhythmic agents as management options. Conclusion and Relevance: Paroxysmal SVT affects both adult and pediatric populations and is generally a benign condition. Catheter ablation is the most effective therapy to prevent recurrent PSVT. Pharmacotherapy is an important component of acute and long-term management of PSVT.


Asunto(s)
Taquicardia Ventricular , Adulto , Niño , Femenino , Humanos , Masculino , Adenosina/administración & dosificación , Adenosina/uso terapéutico , Administración Intravenosa , Antiarrítmicos/administración & dosificación , Antiarrítmicos/uso terapéutico , Cardiomiopatías/etiología , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Ablación por Catéter , Electrocardiografía , Maniobra de Valsalva , Cardioversión Eléctrica
4.
Am Heart J ; 261: 95-103, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37019195

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice and is associated with significant morbidity, mortality, and financial burden. Obstructive sleep apnea (OSA) is more common in individuals with AF and may impair the efficacy of rhythm control strategies including catheter ablation. However, the prevalence of undiagnosed OSA in all-comers with AF is unknown. DESIGN: This pragmatic, phase IV prospective cohort study will test 250-300 consecutive ambulatory AF patients with all patterns of atrial fibrillation (paroxysmal, persistent, and long-term persistent) and no prior sleep testing for OSA using the WatchPAT system, a disposable home sleep test (HST). The primary outcome of the study is the prevalence of undiagnosed OSA in all-comers with atrial fibrillation. RESULTS: Preliminary results from the initial pilot enrollment of approximately 15% (N = 38) of the planned sample size demonstrate a 79.0% prevalence of at least mild (AHI≥5) OSA or greater in consecutively enrolled patient with all patterns of AF. CONCLUSIONS: We report the design, methodology, and preliminary results of our study to define the prevalence of OSA in AF patients. This study will help inform approaches to OSA screening in patients with AF for which there is currently little practical guidance. CLINICAL TRIAL REGISTRATION: NCT05155813.


Asunto(s)
Fibrilación Atrial , Apnea Obstructiva del Sueño , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Factores de Riesgo , Sueño , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/epidemiología , Apnea Obstructiva del Sueño/complicaciones
5.
Pacing Clin Electrophysiol ; 46(1): 3-10, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36301182

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) technology has been increasingly accepted as an integral part of atrial fibrillation (AF) ablation procedures. It is still unknown whether ICE can routinely replace transesophageal echocardiography (TEE) for routine thrombus screening in non-selective AF patients. OBJECTIVE: To assess whether ICE can routinely replace TEE in screening for left atrial (LA)/left atrial appendage (LAA) thrombus in general patients undergoing catheter ablation for AF. METHODS: A total of 2003 consecutive patients undergoing AF ablation were included. 1155 patients (ICE group) received intra-procedural ICE examination for LA/LAA thrombus screening, while 848 patients (TEE group) received pre-procedure TEE examination. The incidence of thrombus, peri-procedure complications, and hospital efficiency were assessed. RESULTS: The LA and LAA were adequately visualized in all patients. Five patients in the ICE group and 15 patients in the TEE group were found to have LAA thrombus. The incidence of major periprocedural thrombo-embolic events was comparable between two groups (0.2% vs. 0.1%, p = .76), none were due to undetected LA/LAA thrombus. Other major periprocedural complications occurred at similar rates in both groups, while post-procedure fever was less common in the ICE group (12.7% vs. 17.4%, p < .001). Procedure times and hospital length of stay were both shorter in the ICE group (142 min [87-197 min] vs. 150 min [95-205 min], and 3[2-4] day vs. 4[3-5] day, respectively, both p < .001). CONCLUSIONS: ICE can replace TEE for atrial thrombus screening in AF patients undergoing ablation without increased complications. An "ICE replacing TEE" workflow can also reduce the incidence of postoperative fever and improve hospital efficiency.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Cardiopatías , Trombosis , Humanos , Ecocardiografía Transesofágica/métodos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cardiopatías/complicaciones , Trombosis/complicaciones
6.
Pacing Clin Electrophysiol ; 46(9): 1035-1048, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37573146

RESUMEN

Transcatheter radiofrequency ablation has been widely introduced for the treatment of tachyarrhythmias. The demand for catheter ablation continues to grow rapidly as the level of recommendation for catheter ablation. Traditional catheter ablation is performed under the guidance of X-rays. X-rays can help display the heart contour and catheter position, but the radiobiological effects caused by ionizing radiation and the occupational injuries worn caused by medical staff wearing heavy protective equipment cannot be ignored. Three-dimensional mapping system and intracardiac echocardiography can provide detailed anatomical and electrical information during cardiac electrophysiological study and ablation procedure, and can also greatly reduce or avoid the use of X-rays. In recent years, fluoroless catheter ablation technique has been well demonstrated for most arrhythmic diseases. Several centers have reported performing procedures in a purposefully designed fluoroless electrophysiology catheterization laboratory (EP Lab) without fixed digital subtraction angiography equipment. In view of the lack of relevant standardized configurations and operating procedures, this expert task force has written this consensus statement in combination with relevant research and experience from China and abroad, with the aim of providing guidance for hospitals (institutions) and physicians intending to build a fluoroless cardiac EP Lab, implement relevant technologies, promote the standardized construction of the fluoroless cardiac EP Lab.


Asunto(s)
Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Cirugía Asistida por Computador , Humanos , Electrofisiología Cardíaca , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 45(10): 1216-1224, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35998211

RESUMEN

Recurrence of atrial fibrillation (AF) after catheter ablation is common, with pulmonary vein (PV) reconnection considered the most likely cause. However, technologies such as contact force-sensing, irrigated catheters, and ablation index (AI)-guided ablation strategies have resulted in more durable PV isolation. As a result, it is difficult to predict which patients will develop AF recurrence despite durable PV isolation, with evolving non-PV atrial substrates thought to be a key contributor to late recurrences. Deciphering the complex mechanisms of AF recurrence beyond the cornerstone of PV isolation therefore remains challenging. Recently, there have been several important advances that may lead to better understanding and treatment of this challenging clinical entity: percutaneous epicardial access and mapping, late gadolinium enhancement magnetic resonance imaging (LGE-MRI), improvements in high-resolution electroanatomic mapping, and new ablation energy sources, specifically pulsed-field ablation. This review aims to synthesize the current literature in an effort to better understand arrhythmia mechanisms and treatment targets in patients with AF/Atrial tachycardia (AT) recurrence post-ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Gadolinio , Medios de Contraste , Recurrencia , Resultado del Tratamiento , Ablación por Catéter/métodos , Pericardio/cirugía
8.
Pacing Clin Electrophysiol ; 45(9): 1124-1131, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35621224

RESUMEN

AIMS: To compare the cost of cardiac stereotactic body radioablation therapy (SBRT) versus catheter ablation for treating ventricular tachycardia (VT). BACKGROUND: Cardiac SBRT is a novel way of treating refractory VT that may be less costly than catheter ablation, owing to its noninvasive, outpatient nature. However, the true costs of either procedure are not well described, which could help inform a more appropriate reimbursement for cardiac SBRT than simply cross-indexing existing procedural rates. METHODS: Process maps were derived for the full patient care cycle of both procedures using time-driven activity-based costing. Step-by-step timestamps were collected prospectively from a 10-patient SBRT cohort and retrospectively from a 59-patient catheter ablation cohort. Individual costs were estimated by multiplying timestamps with capacity cost rates (CCRs) for personnel, space, equipment, consumable, and indirect resources. These were summed into total cost, which for cardiac SBRT was compared with current catheter ablation and single-fraction lung SBRT reimbursements, both potential reference rates for cardiac SBRT. RESULTS: The direct and total procedural costs of cardiac SBRT ($7549 and $10,621) were 49% and 54% less than those of VT ablation ($14,707 and $23,225). These costs were significantly different from current reimbursement for catheter ablation ($22,692) and lung SBRT ($6329). After including hospitalization expenses (≥$15,000), VT ablation costs at least $27,604 more to furnish than cardiac SBRT. CONCLUSIONS: Time-driven activity-based costing (TDABC) can be a helpful tool for assessing healthcare costs, including novel treatment approaches. In addition to its clinical benefits, cardiac SBRT may provide significant cost reduction opportunities for treatment of VT.


Asunto(s)
Ablación por Catéter , Radiocirugia , Taquicardia Ventricular , Antiarrítmicos/uso terapéutico , Ablación por Catéter/métodos , Humanos , Radiocirugia/métodos , Estudios Retrospectivos , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 32(7): 1814-1821, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33825242

RESUMEN

INTRODUCTION: Contact force (CF) guided ablation of paroxysmal atrial fibrillation (PAF) with stable catheter-tissue contact optimizes clinical success and may increase an operator's ability to achieve pulmonary vein isolation (PVI) in a single encirclement. First pass PVI reduces procedure time but the relationship with long term clinical success is not well understood. This study evaluated patient characteristics and procedural details as predictors of 1-year clinical success after PAF ablation, including first pass isolation. METHODS: Consecutive de novo PAF ablations were performed with a porous tip CF catheter in 2017 and 2018. All ablations used wide-area circumferential ablation, with first pass isolation captured separately for the left and right pulmonary veins (PVs). CF was held between 10 and 20 g and the catheter was moved every 10-20 s. Radiofrequency energy was set at 40-45 W throughout the atrium. Patient characteristics and procedural details were tested for association with clinical success, defined as freedom from recurrent atrial tachyarrhythmia through 1 year. RESULTS: A total of 404 patients were included in the study. Clinical success at 1 year was 86.6%. Achieving first pass isolation on at least one ipsilateral PV pair was the most significant predictor of clinical success (p = .0126). After controlling for first pass isolation, only recurrence within the 90-day blanking period was independently predictive (p = .0015). First pass isolation was not associated with early recurrence (p = .2454). CONCLUSION: In a real-world setting, first pass isolation was highly predictive of 12-month clinical success after CF-guided ablation in a PAF population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 32(11): 2901-2914, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34587335

RESUMEN

INTRODUCTION: Despite advances in drug and catheter ablation therapy, long-term recurrence rates for ventricular tachycardia remain suboptimal. Cardiac stereotactic body radiotherapy (SBRT) is a novel treatment that has demonstrated reduction of arrhythmia episodes and favorable short-term safety profile in treatment-refractory patients. Nevertheless, the current clinical experience is early and limited. Recent studies have highlighted variable duration of treatment effect and substantial recurrence rates several months postradiation. Contributing to these differential outcomes are disparate approaches groups have taken in planning and delivering radiation, owing to both technical and knowledge gaps limiting optimization and standardization of cardiac SBRT. METHODS AND FINDINGS: In this report, we review the historical basis for cardiac SBRT and existing clinical data. We then elucidate the current technical gaps in cardiac radioablation, incorporating the current clinical experience, and summarize the ongoing and needed efforts to resolve them. CONCLUSION: Cardiac SBRT is an emerging therapy that holds promise for the treatment of ventricular tachycardia. Technical gaps remain, to be addressed by ongoing research and growing clincial experience.


Asunto(s)
Ablación por Catéter , Radiocirugia , Taquicardia Ventricular , Arritmias Cardíacas , Ablación por Catéter/efectos adversos , Corazón , Humanos , Radiocirugia/efectos adversos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
13.
Pacing Clin Electrophysiol ; 43(7): 646-654, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32391576

RESUMEN

Catheter ablation has emerged as an effective treatment for atrial fibrillation (AF). Atrial esophageal fistula (AEF) is a rare, but feared complication. With increasing utilization of ablation therapy for AF, the understanding of the relationship between AEF and ablation has been improved in recent years. Efforts to reduce the risk of AEF have focused on decreasing the risk of severe esophageal injury (EI) and the presumed subsequent progression from EI to AEF, including esophageal temperature monitoring, esophageal cooling systems, esophageal deviation devices, and decreasing and/or curtailing ablation energy delivery. Periprocedural assessment may help identify higher risk patients and detect early esophageal lesions. This review systematically summarizes and evaluates the current strategies and techniques utilized to reduce the risk of AEF in the clinical workflow for AF ablation. We expect that this review will help clinicians to better understand the principles, advantages, and disadvantages of these methods, and to find suitable strategies using current available tools.


Asunto(s)
Quemaduras/prevención & control , Ablación por Catéter , Fístula Esofágica/prevención & control , Esófago/lesiones , Atrios Cardíacos/cirugía , Complicaciones Posoperatorias/prevención & control , Fibrilación Atrial/cirugía , Quemaduras/etiología , Fístula Esofágica/etiología , Humanos , Complicaciones Posoperatorias/etiología
14.
Pacing Clin Electrophysiol ; 43(1): 12-18, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31736095

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) ablation requires access to the left atrium (LA) via transseptal puncture (TP). TP is traditionally performed with fluoroscopic guidance. Use of intracardiac echocardiography (ICE) and three-dimensional mapping allows for zero fluoroscopy TP. OBJECTIVE: To demonstrate safety and efficacy of zero fluoroscopy TP using multiple procedural approaches. METHODS: Patients undergoing AF ablation between January 2015 and November 2017 at five institutions were included. ICE and three-dimensional mapping were used for sheath positioning and TP. Variable technical approaches were used across centers including placement of J wire in the superior vena cava with ICE guidance followed by dragging down the transseptal sheath into the interatrial septum, or guiding the transseptal sheath directly to the interatrial septum by localizing the ablation catheter with three-dimensional mapping and replacing it with the transseptal needle once in position. In patients with pacemaker/implantable cardiac defibrillator leads, pre-/poststudy device interrogation was performed. RESULTS: A total of 747 TPs were performed (646 patients, age 63.1 ± 13.1, 67.5% male, LA volume index 34.5 ± 15.8 mL/m2 , ejection fraction 57.7 ± 10.9%) with 100% success. No punctures required fluoroscopy. Two pericardial effusions, two pericardial tamponades requiring pericardiocentesis, and one transient ischemic attack were observed during the overall ablation procedure, with a total complication rate of 0.7%. There were no other periprocedural complications related to TP, including intrathoracic bleeding, stroke, or death both immediately following TP and within 30 days of the procedure. In patients with intracardiac devices, no device-related complications were observed. CONCLUSION: TP can be safely and effectively performed without the need for fluoroscopy.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ecocardiografía/métodos , Atrios Cardíacos/cirugía , Ultrasonografía Intervencional/métodos , Mapeo Epicárdico , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Punciones
15.
J Cardiovasc Electrophysiol ; 29(6): 854-860, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29570900

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) ablation is increasingly common, but is associated with potential major complications. Technology, experience, and protocols have evolved significantly in recent times, and may have impacted procedural safety. We sought to compare AF ablation safety profiles, including complication rates and fluoroscopy times in a "modern" versus "historical" cohort. METHODS AND RESULTS: We evaluated consecutive patients undergoing AF ablation from a modern cohort (MC) from 2014 to 2015 and a historic cohort (HC) from 2009 to 2011 for complications. Major complications were categorized according to Heart Rhythm Society guidelines. We included 1,425 patients, 726 in the HC and 699 in the MC. The MC was older, had more OSA and less valvular AF. Fifty-two (3.5%) procedures suffered major complications across the cohorts, with significantly fewer in the MC (5.0% vs. 2.3%, P  =  0.007). The largest reductions were seen in vascular, hemorrhagic, ischemic stroke, and perforation/tamponade related complications. Periprocedural antiplatelets drugs (aHR 2.1 [95 CI 1.1-3.9], P  =  0.02) and force-sensing catheters (aHR 0.4 [95 CI 0.2-0.9], P  =  0.03) were independently related to major complication rates. Direct oral anticoagulants and uninterrupted anticoagulation were not associated with complications. There was a decrease in both fluoroscopy (-17.4 minutes [95 CI 19.2-15.6], P < 0.0001) and radiofrequency ablation times (-561 seconds [95CI -750 to -371], P < 0.0001). CONCLUSIONS: The safety profile of AF ablation has improved significantly in less than a decade.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/tendencias , Complicaciones Posoperatorias/prevención & control , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Radiografía Intervencional/tendencias , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 29(5): 687-695, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29377478

RESUMEN

OBJECTIVE: To investigate mechanisms by which atrial fibrillation (AF) may terminate during ablation near the pulmonary veins before the veins are isolated (PVI). INTRODUCTION: It remains unstudied how AF may terminate during ablation before PVs are isolated, or how patients with PV reconnection can be arrhythmia-free. We studied patients in whom PV antral ablation terminated AF before PVI, using two independent mapping methods. METHODS: We studied patients with AF referred for ablation, in whom biatrial contact basket electrograms were studied by both an activation/phase mapping method and by a second validated mapping method reported not to create false rotational activity. RESULTS: In 22 patients (age 60.1 ± 10.4, 36% persistent AF), ablation at sites near the PVs terminated AF (77% to sinus rhythm) prior to PVI. AF propagation revealed rotational (n  =  20) and focal (n  =  2) patterns at sites of termination by mapping method 1 and method 2. Both methods showed organized sites that were spatially concordant (P < 0.001) with similar stability (P < 0.001). Vagal slowing was not observed at sites of AF termination. DISCUSSION: PV antral regions where ablation terminated AF before PVI exhibited rotational and focal activation by two independent mapping methods. These data provide an alternative mechanism for the success of PVI, and may explain AF termination before PVI or lack of arrhythmias despite PV reconnection. Mapping such sites may enable targeted PV lesion sets and improved freedom from AF.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
18.
Curr Cardiol Rep ; 19(9): 79, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28752279

RESUMEN

PURPOSE OF REVIEW: Stereotactic radioablation is a commonly utilized technology to noninvasively treat solid tumors with precision and efficacy. Using a robotic arm mounted delivery system, multiple low-dose ionizing radiation beams are delivered from multiple angles, concentrating ablative energy at the target tissue. Recently, this technology has been evaluated for treatment of cardiac arrhythmias. This review will present the basic underlying principles, proof-of-principle studies, and clinical experience with stereotactic arrhythmia radioablation. RECENT FINDINGS: Most recently, stereotactic radioablation has been used to safely and effectively treat a limited number of patients with malignant arrhythmias, including ventricular tachycardia (VT) and atrial fibrillation (AF). Treatment protocols, outcomes, ongoing studies, and future directions will be discussed. Stereotactic radioablation is a well-established technology that has been shown to be a safe and effective therapy for patients with drug-refractory cardiac arrhythmias, including VT and AF. Further clinical evaluation to define safety and efficacy in larger populations of patients is needed.


Asunto(s)
Arritmias Cardíacas/radioterapia , Radiocirugia , Fibrilación Atrial/radioterapia , Ablación por Catéter , Protocolos Clínicos , Humanos , Taquicardia Ventricular/radioterapia
19.
N Engl J Med ; 378(17): 1650, 2018 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-29697916
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA