Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Anal Chem ; 96(36): 14471-14479, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39185581

RESUMEN

The spatial constraints imposed by the DNA structure have significant implications for the walking efficiency of three-dimensional DNA walkers. However, accurately quantifying and manipulating steric hindrance remains a challenging task. This study presents a steric hindrance-controlled DNA walker utilizing an enzymatic strand displacement amplification (ESDA) strategy for detecting microRNA-21 (miR-21) with tunable dynamic range and sensitivity. The steric hindrance of the DNA walker was precisely manipulated by varying the length of empty bases from 6.5 Što 27.4 Šat the end of the track strand and adjusting the volumetric dimensions of the hairpin structure from 9.13 nm3 to 26.2 nm3 at the terminus of the single-foot DNA walking strand. This method demonstrated a tunable limit of detection for miR-21 ranging from 3.6 aM to 35.6 nM, along with a dynamic range from ∼100-fold to ∼166 000-fold. Impressively, it exhibited successful identification of cancer cells and clinical serum samples with high miR-21 expression. The proposed novel strategy not only enables tunable detection of miRNA through the regulation of steric hindrance but also achieves accurate and quantitative analysis of the steric hindrance effect, promising broader applications in personalized medicine, early disease detection, and drug development.


Asunto(s)
ADN , MicroARNs , Técnicas de Amplificación de Ácido Nucleico , MicroARNs/análisis , MicroARNs/sangre , Humanos , ADN/química , Límite de Detección , Técnicas Biosensibles
2.
Anal Chem ; 95(45): 16744-16753, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37929302

RESUMEN

Tunable detection of microRNA is crucial to meet the desired demand for sample species with varying concentrations in clinical settings. Herein, we present a DNA walker-based molecular circuit for the detection of miRNA-21 (miR-21) with tunable dynamic ranges and sensitivity levels ranging from fM to pM. The phosphate-activated fluorescence of UiO-66-NH2 metal-organic framework nanoparticles was used as label-free fluorescence tags due to their competitive coordination effect with the Zr atom, which significantly inhibited the ligand-to-metal charge transfer. To achieve a tunable detection performance for miR-21, the ultraviolet sensitive o-nitrobenzyl was induced as a photocleavable linker, which was inserted at various sites between the loop and the stem of the hairpin probe to regulate the DNA strand displacement reaction. The dynamic range can be precisely regulated from 700- to 67,000-fold with tunable limits of detection ranging from 2.5 fM to 36.7 pM. Impressively, a Boolean logic tree and complex molecular circuit were constructed for logic computation and cancer diagnosis in clinical blood samples. This intelligent biosensing method presents a powerful solution for converting complex biosensing systems into actionable healthcare decisions and will facilitate early disease diagnosis.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Estructuras Metalorgánicas , MicroARNs , Nanopartículas , ADN , MicroARNs/genética , Técnicas Biosensibles/métodos , Límite de Detección
3.
Anal Chim Acta ; 1319: 342980, 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39122289

RESUMEN

The traditional preparation method of ratiometric probes faces challenges such as cumbersome preparation and low sensitivity. Thus, there is an urgent need to provide a simple method of preparing a highly sensitive ratiometric probe. Here, Eu3+-doped zinc-based organic framework (Eu/Zn-MOF) was prepared through hydrothermal method for the detection of tetracycline analogs (TCs). Under the same excitation conditions, the probe can simultaneously display valuable fluorescence and second-order scattering signals. The developed probe enabled specific identification and fast detection (1 min) of TCs, including tetracycline, oxytetracycline, doxycycline, and chlortetracycline. The linear detection ranges of tetracycline, oxytetracycline, doxycycline and chlortetracycline were respectively 100 nM - 200 µM, 100 nM - 200 µM, 98 nM - 195 µM, and 97 nM - 291 µM, and the corresponding detection limits were respectively 15.79 nM, 20.83 nM, 15.31 nM, and 28.30 nM. The developed sensor was successfully applied to detect TCs in real samples, and the recovery rate was from 92.54 % to 109.69 % and the relative standard deviation was from 0.04 % to 2.97 %. Moreover, the heterometallic Eu/Zn-MOF was designed as a ratiometric neuron for Boolean logic computing and information encryption based on the specific identification of TCs. As a proof of concept, molecular steganography was successfully employed to encode, store, and conceal information by transforming the specific identification patterns of Eu/Zn-MOF into binary strings. This study is anticipated to advance the application of metal-organic frameworks in logic detection and information security, and bridging the gap between molecular sensors and the realm of information.


Asunto(s)
Europio , Estructuras Metalorgánicas , Espectrometría de Fluorescencia , Zinc , Estructuras Metalorgánicas/química , Europio/química , Zinc/química , Zinc/análisis , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Tetraciclinas/análisis , Límite de Detección , Antibacterianos/análisis , Tetraciclina/análisis , Fluorescencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA