Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 96(15): 5852-5859, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38556977

RESUMEN

A multicolor electrochemiluminescence (ECL) biosensor based on a closed bipolar electrode (BPE) array was proposed for the rapid and intuitive analysis of three prostate cancer staging indicators. First, [Irpic-OMe], [Ir(ppy)2(acac)], and [Ru(bpy)3]2+ were applied as blue, green, and red ECL emitters, respectively, whose mixed ECL emission colors covered the whole visible region by varying the applied voltages. Afterward, we designed a simple Mg2+-dependent DNAzyme (MNAzyme)-driven tripedal DNA walker (TD walker) to release three output DNAs. Immediately after, three output DNAs were added to the cathodic reservoirs of the BPE for incubation. After that, we found that the emission colors from the anode of the BPE changed as a driving voltage of 8.0 V was applied, mainly due to changes in the interfacial potential and faradaic currents at the two poles of the BPE. Via optimization of the experimental parameters, cutoff values of such three indicators at different clinical stages could be identified instantly with the naked eye, and standard precision swatches with multiple indicators could be prepared. Finally, in order to precisely determine the prostate cancer stage, the multicolor ECL device was used for clinical analysis, and the resulting images were then compared with standard swatches, laying the way for accurate prostate cancer therapy.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Próstata , Masculino , Humanos , Mediciones Luminiscentes/métodos , Fotometría , Neoplasias de la Próstata/diagnóstico , Antígeno Prostático Específico , ADN , Técnicas Biosensibles/métodos , Electrodos , Técnicas Electroquímicas/métodos
2.
Appl Environ Microbiol ; 90(2): e0202523, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38259074

RESUMEN

Marine bacteria play important roles in the degradation and cycling of algal polysaccharides. However, the dynamics of epiphytic bacterial communities and their roles in algal polysaccharide degradation during kelp decay are still unclear. Here, we performed metagenomic analyses to investigate the identities and predicted metabolic abilities of epiphytic bacterial communities during the early and late decay stages of the kelp Saccharina japonica. During kelp decay, the dominant epiphytic bacterial communities shifted from Gammaproteobacteria to Verrucomicrobia and Bacteroidetes. In the early decay stage of S. japonica, epiphytic bacteria primarily targeted kelp-derived labile alginate for degradation, among which the gammaproteobacterial Vibrionaceae (particularly Vibrio) and Psychromonadaceae (particularly Psychromonas), abundant in alginate lyases belonging to the polysaccharide lyase (PL) families PL6, PL7, and PL17, were key alginate degraders. More complex fucoidan was preferred to be degraded in the late decay stage of S. japonica by epiphytic bacteria, predominantly from Verrucomicrobia (particularly Lentimonas), Pirellulaceae of Planctomycetes (particularly Rhodopirellula), Pontiellaceae of Kiritimatiellota, and Flavobacteriaceae of Bacteroidetes, which depended on using glycoside hydrolases (GHs) from the GH29, GH95, and GH141 families and sulfatases from the S1_15, S1_16, S1_17, and S1_25 families to depolymerize fucoidan. The pathways for algal polysaccharide degradation in dominant epiphytic bacterial groups were reconstructed based on analyses of metagenome-assembled genomes. This study sheds light on the roles of different epiphytic bacteria in the degradation of brown algal polysaccharides.IMPORTANCEKelps are important primary producers in coastal marine ecosystems. Polysaccharides, as major components of brown algal biomass, constitute a large fraction of organic carbon in the ocean. However, knowledge of the identities and pathways of epiphytic bacteria involved in the degradation process of brown algal polysaccharides during kelp decay is still elusive. Here, based on metagenomic analyses, the succession of epiphytic bacterial communities and their metabolic potential were investigated during the early and late decay stages of Saccharina japonica. Our study revealed a transition in algal polysaccharide-degrading bacteria during kelp decay, shifting from alginate-degrading Gammaproteobacteria to fucoidan-degrading Verrucomicrobia, Planctomycetes, Kiritimatiellota, and Bacteroidetes. A model for the dynamic degradation of algal cell wall polysaccharides, a complex organic carbon, by epiphytic microbiota during kelp decay was proposed. This study deepens our understanding of the role of epiphytic bacteria in marine algal carbon cycling as well as pathogen control in algal culture.


Asunto(s)
Algas Comestibles , Flavobacteriaceae , Kelp , Laminaria , Microbiota , Phaeophyceae , Humanos , Metagenoma , Kelp/metabolismo , Polisacáridos/metabolismo , Alginatos/metabolismo , Flavobacteriaceae/genética , Flavobacteriaceae/metabolismo , Carbono/metabolismo
3.
Pediatr Radiol ; 53(5): 910-919, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36602571

RESUMEN

BACKGROUND: Fetal dedicated echocardiography is the standard to measure the fetal cardiac axis. However, fetal screening ultrasound (US) or fetal dedicated echocardiography may be technically limited. OBJECTIVE: The purpose of this study was to explore the accuracy of fetal cardiac magnetic resonance imaging (MRI) to measure the cardiac axis in fetuses with congenital heart disease as an adjunct to fetal dedicated echocardiography and to assess the predictive value of fetal cardiac MRI measurements in distinguishing healthy fetuses from fetuses with congenital heart disease. MATERIALS AND METHODS: This is a retrospective study of fetuses referred to our hospital for a fetal cardiac MRI from November 2019 to December 2021. Cardiac axes were measured in the 4-chamber view of the fetal heart using fetal cardiac MRI and dedicated echocardiography, or only using fetal cardiac MRI when screening US was technically limited. The fetuses were divided into a congenital heart disease group and a healthy control group. We used Bland-Altman analysis and the intraclass correlation coefficient (ICC) to assess the agreement of cardiac axis measurements in fetuses with congenital heart disease obtained by cardiac MRI and by fetal dedicated echocardiography. Receiver operating characteristic (ROC) curve analysis of the fetal cardiac axes in the congenital heart disease and healthy fetus groups assessed the predictive value of the cardiac axis measurements. RESULTS: This retrospective study included 431 women (162 carrying fetuses with congenital heart disease, 269 carrying healthy fetuses). Cardiac axes were measured in the 162 fetuses with congenital heart disease using fetal cardiac MRI and dedicated echocardiography. Cardiac axes were measured in the 269 healthy control fetuses using fetal cardiac MRI when fetal screening US was technically limited. The interobserver analysis and intraobserver analysis showed that the cardiac axis measured by fetal cardiac MRI and fetal dedicated echocardiography was repeatable (ICC>0.90). In 162 fetuses with congenital heart disease, Bland-Altman analysis showed a strong agreement between cardiac MRI and fetal dedicated echocardiography measurements for the cardiac axis. The ICC for the cardiac axis values between cardiac MRI and fetal dedicated echocardiography measurements was 0.99. In fetuses with congenital heart disease, 64.2% (104/162) had an abnormal cardiac axis. For the fetal cardiac axis in both the 162 fetuses with congenital heart disease and the 269 healthy fetuses, the area under the ROC curve reached 0.85 (95% confidence interval: 0.80-0.89; P<0.0001). CONCLUSION: The cardiac axis can be accurately measured using fetal cardiac MRI when fetal dedicated echocardiography/fetal screening US is technically limited. The cardiac axis measurements by fetal cardiac MRI are consistent with known cardiac axis measurements by fetal dedicated echocardiography. The frequency of abnormal cardiac axis depends on the type of congenital heart disease.


Asunto(s)
Cardiopatías Congénitas , Embarazo , Femenino , Humanos , Estudios Retrospectivos , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Magnética , Diagnóstico Prenatal , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/patología , Ultrasonografía Prenatal/métodos
4.
Psychol Health Med ; 27(9): 2007-2020, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34818948

RESUMEN

The bidirectional associations between parenting styles and conduct problems in Chinese children attending preschools were rarely discussed. A study covering 171 preschools in Longhua District of Shenzhen, China was conducted among children when they first attended preschools. Parents of children reported the self-perceived parenting styles and their children's conduct problems using validated questionnaires. The bidirectional associations between parenting styles and conduct problems in children were assessed using multivariate linear or logistic regressions in both cross-sectional and cohort settings. In cross-sectional settings, the bidirectional associations were present in all dimensions of parenting styles with children's conduct problems. After 1.01 years of follow-up, increases in parenting dimensions of rejection, control attempts, and favoring subject were significantly associated with children's conduct problems at follow-up, while increases in emotional warmth of parents significantly reduced such risk. In addition, parents of children who had conduct problems at baseline but regressed to normal at follow-up showed decreased scores in negative parenting dimensions. In contrast, among children who developed conduct problems during the study period, the scores of rejection and favoring subject in their parents have increased significantly, while the scores of emotional warmth have decreased. Parent-to-child effect was similar between fathers and mothers, while child-to-parent effect was stronger in fathers than that in mothers. In order to stop the negative feedback loop between poor parenting styles and children's conduct problems, our study underscored the importance of intervention not only in parents but also in their children.


Asunto(s)
Madres , Responsabilidad Parental , Preescolar , Estudios de Cohortes , Estudios Transversales , Femenino , Humanos , Madres/psicología , Relaciones Padres-Hijo , Responsabilidad Parental/psicología , Padres , Encuestas y Cuestionarios
5.
Opt Express ; 29(24): 39125-39136, 2021 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-34809282

RESUMEN

A linearly-polarized radiation can be considered as the superposition of two circularly-polarized components with the same propagating direction and opposite spins. We investigated the splitting between the two spin-components in the reflective beam off the antiferromagnetic surface. The gyromagnetism and surface impedance mismatch cause the difference between the spatial shifts of the two spin-components, i.e., the spin-splitting. We analytically achieved the in- and out-plane shift-expressions of either spin-component for two typical linearly-polarized incident beams (i.e., the p- and s-incidences). In the case of no gyromagnetism, we obtained very simple shift-expressions, which indicate a key role played by the gyromagnetism or the surface impedance-mismatch in spin-splitting. Based on a FeF2 crystal, the spin-splitting distance was calculated. The spin-splitting distance is much longer for the p-incidence than the s-incidence, and meanwhile the in-plane splitting distance is much larger than the out-plane one. The gyromagnetism plays a key role for the in-plane spin-splitting and the surface impedance-mismatch is a crucial factor for the out-plane spin-splitting distance. The results are useful for the manipulation of infrared radiations and infrared optical detection.

6.
Echocardiography ; 38(2): 169-174, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33368575

RESUMEN

BACKGROUND: Double-chambered left ventricle (DCLV) is extremely rare. Challenges remain in accurate diagnosis of DCLV by echocardiography, because it is easily confused with left ventricular diverticulum, left ventricular aneurysm, ventricular septal defect, etc. Herein, we reviewed echocardiographic characteristics of DCLV and evaluated the accuracy of echocardiographic diagnosis. METHODS: Clinical and echocardiographical databases of two heart centers were reviewed. Nine children with DCLV of superior-inferior arrangement were studied retrospectively. RESULTS: Normal elliptical geometry of LV cavity is preserved in DCLV. Fibromuscluar bundles separate LV into the main chamber and the accessory chamber. The associated malformations included ventricular septal defects, mitral regurgitation, mitral valve stenosis, pulmonary stenosis, and left ventricular noncompaction in our study. Eight of nine subjects with DCLV of superior-inferior arrangement were diagnosed correctly by initial echocardiographic examination, and one case was mistaken as left ventricular diverticulum. CONCLUSIONS: Double-chambered left ventricle could be diagnosed and followed up by echocardiography. The morphological classification is a simplified way to improve diagnostic accuracy.


Asunto(s)
Cardiopatías Congénitas , Defectos del Tabique Interventricular , Niño , Ecocardiografía , Cardiopatías Congénitas/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Estudios Retrospectivos
7.
Echocardiography ; 38(8): 1218-1227, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34156720

RESUMEN

BACKGROUND: This study aimed to evaluate the feasibility and clinical value of real time three-dimensional echocardiography (RT-3DE) for assessing ventricular systolic dysfunction and dyssynchrony in children with an functional single right ventricle (FSRV) having undergone the Fontan procedure. METHODS: Twenty-five children with an FSRV and 25 healthy children were enrolled in our study. RV volume analysis was performed compared with magnetic resonance imaging (MRI) as the reference standard in FSRV patients. The patients were divided into wide and narrow QRS interval groups. Global and regional functions of the RV in three compartments (inflow, body, and outflow) were compared between FSRV and control subjects, including RV systolic dyssynchrony indices of maximal difference of time to minimal volume (Tmsv-Dif), standard deviation of time to minimal volume (Tmsv-SD), maximal difference of time to minimal volume corrected by R-R interval (Tmsv-Dif%), and standard deviation of time to minimal volume corrected by R-R interval (Tmsv-SD%). RESULTS: RT-3DE measurements were significantly lower than MRI measurements for RV-EDV, RV-ESV, RV-SV, and RVEF (p < 0.01).Compared with controls, patients with an FRSV had significantly higher dyssynchrony indices and significantly lower global EF in both narrow QRS interval and wide QRS interval groups. Tmsv-SD% was shown to be most strongly correlated with MRI-RVEF (r = -.570, p = 0.003). CONCLUSIONS: RT-3DE tended to underestimate RV ventricular volume in children with FSRV. Children with an FSRV and either a wide or narrow QRS interval had reduced ventricular function and higher dyssynchrony than normal subjects. Worsening RV dyssynchrony is associated with overall decline in function after the Fontan operation.


Asunto(s)
Ecocardiografía Tridimensional , Procedimiento de Fontan , Niño , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Volumen Sistólico , Sístole , Función Ventricular , Función Ventricular Derecha
8.
Anal Chem ; 92(17): 11935-11942, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32702970

RESUMEN

The isolation of nanobodies (Nbs) from phage display libraries is an increasingly effective approach for the generation of new biorecognition elements, which can be used to develop immunoassays. In this study, highly specific Nbs against the Alternaria mycotoxin tenuazonic acid (TeA) were isolated from an immune nanobody phage display library using a stringent biopanning strategy. The obtained Nbs were characterized by classical enzyme-linked immunosorbent assay (ELISA), and the best one Nb-3F9 was fused with nanoluciferase to prepare an advanced bifunctional fusion named nanobody-nanoluciferase (Nb-Nluc). In order to improve the sensitivity and reduce the assay time, two different kinds of luminescent strategies including chemiluminescent enzyme immunoassay (CLEIA) and bioluminescent enzyme immunoassay (BLEIA) were established, respectively, on the basis of the single Nb and the fusion protein Nb-Nluc for TeA detection. The two-step CLEIA was developed on the basis of the same nanobody as ELISA, only with simple substrate replacement from 3,3',5,5'-tetramethylbenzidine (TMB) to luminol. In contrast with CLEIA, the novel BLEIA was conducted in one-step new strategy on the basis of Nb-Nluc and bioluminescent substrate coelenterazine-h (CTZ-h). Their half maximal inhibitory concentration (IC50) values were similar to 8.6 ng/mL for CLEIA and 9.3 ng/mL for BLEIA, which was a 6-fold improvement in sensitivity compared with that of ELISA (IC50 of 54.8 ng/mL). Both of the two assays provided satisfactory recoveries ranging from 80.1%-113.5% in real samples, which showed better selectivity for TeA analogues and other common mycotoxins. These results suggested that Nbs and Nb-Nluc could be used as useful reagents for immunodetection and that the developed CLEIA/BLEIA have great potential for TeA analysis.


Asunto(s)
Inmunoensayo/métodos , Técnicas para Inmunoenzimas/métodos , Anticuerpos de Dominio Único/inmunología , Ácido Tenuazónico/metabolismo , Humanos
9.
Opt Express ; 28(17): 25048-25059, 2020 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-32907035

RESUMEN

We investigated Goos-Hänchen (GH) and Imbert-Fedorov (IF) shifts on a uniaxial hyperbolic crystal, where a circularly-polarized beam was incident on the crystal from the free space. The GH- and IF-shifts were analytically obtained and numerically calculated for the hexagonal boron nitride. Our results demonstrate that the GH- and IF-shift spectra are complicated and completely different in and out the hyperbolic frequency-bands (the reststrahlen bands in the infrared region). At the critical or Brewster angle, concisely analytical expressions of GH-shift was found, which explicitly state the optical-loss dependence of GH-shift at these special angles. We found the GH-shifts are very large at the critical and Brewster angles. It is very necessary to know these effects since hyperbolic materials are usually applied in the nano- and micro-optics or technology fields.

10.
Zhongguo Zhong Yao Za Zhi ; 45(10): 2257-2264, 2020 May.
Artículo en Zh | MEDLINE | ID: mdl-32495578

RESUMEN

There is urgent need to discover effective traditional Chinese medicine(TCM) for treating coronavirus disease 2019(COVID-19). The development of a bioinformatic tool is beneficial to predict the efficacy of TCM against COVID-19. Here we deve-loped a prediction platform TCMATCOV to predict the efficacy of the anti-coronavirus pneumonia effect of TCM, based on the interaction network imitating the disease network of COVID-19. This COVID-19 network model was constructed by protein-protein interactions of differentially expressed genes in mouse pneumonia caused by SARS-CoV and cytokines specifically up-regulated by COVID-19. TCMATCOV adopted quantitative evaluation algorithm of disease network disturbance after multi-target drug attack to predict potential drug effects. Based on the TCMATCOV platform, 106 TCM were calculated and predicted. Among them, the TCM with a high disturbance score account for a high proportion of the classic anti-COVID-19 prescriptions used by clinicians, suggesting that TCMATCOV has a good prediction ability to discover the effective TCM. The five flavors of Chinese medicine with a disturbance score greater than 1 are mainly spicy and bitter. The main meridian of these TCM is lung, heart, spleen, liver, and stomach meridian. The TCM related with QI and warm TCM have higher disturbance score. As a prediction tool for anti-COVID-19 TCM prescription, TCMATCOV platform possesses the potential to discovery possible effective TCM against COVID-19.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Pandemias , Neumonía Viral , Animales , COVID-19 , Biología Computacional , Medicamentos Herbarios Chinos , Humanos , Medicina Tradicional China , Ratones , SARS-CoV-2
11.
Echocardiography ; 36(1): 133-141, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30515879

RESUMEN

BACKGROUND: Challenges remain in quantitative evaluation of right ventricular (RV) function by echocardiography. Multiple-view assessment is believed to provide a more comprehensive quantification of RV function than conventional single-view analysis. Peak systolic longitudinal RV strain (RVLS) measured by speckle tracking echocardiography (STE) has clinical and prognostic value. No study has investigated RV systolic function in the repaired tetralogy of Fallot (rTOF) using a standardized four-view iRotate model from one apical view. Herein, we examined the feasibility and accuracy of the four-view analysis from apical window in quantitation of RVLS among children with rTOF. METHODS: Thirty-seven children with rTOF and 37 age- and gender-matched controls were prospectively enrolled. Tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (TDI-S' ) and fractional area change(FAC) were obtained. RVLS of four free-walls were analyzed by dedicated RV speckle tracking software. Echocardiographic parameters were compared with the right ventricular ejection fraction (RVEF) measured by the cardiac magnetic resonance (CMR) in children with rTOF. RESULTS: Multi-view RVLS analysis from apical window was feasible in 35 children with rTOF and all the controls. Compared with age- and gender-matched controls, RVLS of the anterior, lateral, inferior-a, and inferior-b walls were significantly reduced in children with rTOF (P < 0.001). RVLS of the anterior, lateral, inferior-a, and inferior-b walls correlated well with CMR-RVEF in children with rTOF (r = -0.667, -0.743, -0.808, -0.695, P < 0.001). CONCLUSIONS: Multi-view analysis of RVLS from apical window can be applied to evaluate the RV function in children with rTOF. RVLS of the inferior wall-a in the aortic view is a novel and accurate indicator of RV function because of its good reproducibility and strong correlation with CMR-RVEF.


Asunto(s)
Ecocardiografía/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Disfunción Ventricular Derecha/diagnóstico por imagen , Preescolar , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha/fisiología
12.
Anal Chem ; 90(21): 12886-12892, 2018 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-30256086

RESUMEN

A heavy chain variable fragment of heavy chain only antibodies derived from camelids termed VHH shows beneficial characteristics for immunoassay in terms of high sensitivity, outstanding stability and ease in expression. In the present study, we isolated six VHHs from phage display library against parathion, which is a widely used organophosphorus pesticide with high toxicity and persistence. One of six selected VHHs named VHH9, showed highest specificity and superior thermo-stability. A VHH9-alkaline phosphatase (AP) fusion was constructed and used to establish a one-step direct competitive fluorescence enzyme immunoassay (dc-FEIA) with a half maximal inhibitory concentration (IC50) of 1.6 ng/mL and a limit of detection of 0.2 ng/mL which was 4-fold or 3-fold higher sensitivity than direct competitive enzyme-linked immunoassay (dc-ELISA) and indirect competitive enzyme-linked immunoassay (ic-ELISA) for parathion. Furthermore, our assay indicated a 50% reduction on operation time compared with the ic-ELISA method. The presented immunoassay was validated with spiked Chinese cabbage, cucumber, and lettuce samples, and confirmed by UPLC-MS/MS. The results indicated that the VHH-AP-based dc-FEIA is a reproducible detection assay for parathion residues in vegetable samples.


Asunto(s)
Paratión/análisis , Residuos de Plaguicidas/análisis , Proteínas Recombinantes de Fusión/inmunología , Anticuerpos de Dominio Único/inmunología , Fosfatasa Alcalina/genética , Animales , Secuencia de Bases , Benzotiazoles/química , Brassica/química , Camelus , Cucumis sativus/química , Fluorescencia , Colorantes Fluorescentes/química , Técnicas para Inmunoenzimas/métodos , Lactuca/química , Límite de Detección , Masculino , Paratión/inmunología , Residuos de Plaguicidas/inmunología , Proteínas Recombinantes de Fusión/genética , Sensibilidad y Especificidad , Anticuerpos de Dominio Único/genética
13.
J Clin Ultrasound ; 46(5): 328-333, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29430653

RESUMEN

OBJECTIVE: Clinical decision making in children with heart disease relies on detailed measurements of cardiac structures using two-dimensional and M-mode echocardiography. However, no echocardiographic reference values are available for the Chinese children. We aimed to establish z-score regression equations for left heart structures in a population-based cohort of healthy Chinese Han children. METHOD: Echocardiography was performed in 545 children with a normal heart. The dimensions of the aortic valve annulus (AVA), aortic sinuses of Valsalva (ASV), sinotubular junction (STJ), ascending aorta (AAO), left atrium (LA), mitral valve annulus (MVA), interventricular septal end-diastolic thickness (IVSd), interventricular septal end-systolic thickness (IVSs), left ventricular end-diastolic diameter (LVIDd), left ventricular end-systolic diameter (LVIDs), left ventricular posterior wall end-diastolic thickness (LVPWd), left ventricular posterior wall end-systolic thickness (LVPWs) were measured. Regression analyses were conducted to relate the measurements of left heart structures to body surface area (BSA). Left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) were calculated. Several models were used, and the adjusted R2 values were compared for each model. RESULTS: AVA, ASV, STJ, AAO, LA, MVA, IVSd, IVSs, LVIDd, LVIDs, LVPWd, and LVPWs had a cubic relationship with BSA. LVEF and LVFS fell within a narrow range. CONCLUSIONS: Our results provide reference values for z scores and regression equations for left heart structures in Han Chinese children. These data may help make a quick and accurate judgment of the routine clinical measurement of left heart structures in children with heart disease.


Asunto(s)
Ecocardiografía/métodos , Etnicidad , Corazón/anatomía & histología , Adolescente , Aorta/anatomía & histología , Aorta/diagnóstico por imagen , Niño , Preescolar , China , Femenino , Corazón/diagnóstico por imagen , Atrios Cardíacos/anatomía & histología , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/anatomía & histología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Masculino , Valores de Referencia , Seno Aórtico
14.
Langmuir ; 33(21): 5283-5290, 2017 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-28485939

RESUMEN

Clusters are an important class of nanoscale molecules or superatoms that exhibit an amazing diversity in structure, chemical composition, shape, and functionality. Assembling two types of clusters is creating emerging cluster-assembled materials (CAMs). In this paper, we report an effective approach to produce quasi two-dimensional (2D) CAMs of two types of spherelike clusters, polyhedral oligomeric silsesquioxanes (POSS), and polyoxometalates (POM). To avoid macrophase separation between the two clusters, they are covalently linked to form a POM-POSS cocluster with Janus characteristics and a dumbbell shape. This Janus characteristics enables the cocluster to self-assemble into diverse nanoaggregates, as conventional amphiphilic molecules and macromolecules do, in selective solvents. In our study, we obtained micelles, vesicles, nanosheets, and nanoribbons by tuning the n-hexane content in mixed solvents of acetone and n-hexane. Ordered packing of clusters in the nanosheets and nanoribbons were directly visualized using high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) technique. We infer that the increase of packing order results in the vesicle-to-sheet transition and the change in packing mode causes the sheet-to-ribbon transitions. Our findings have verified the effectivity of creating quasi 2D cluster-assembled materials though the cocluster self-assembly as a new approach to produce novel CAMs.

15.
J Ind Microbiol Biotechnol ; 44(2): 317-327, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28013394

RESUMEN

Dextranase can hydrolyze dextran to low-molecular-weight polysaccharides, which have important medical applications. In the study, dextranase-producing strains were screened from various soil sources. The strain H6 was identified as Talaromyces pinophilus by a standard ITS rDNA analysis. Crude dextranase was purified by ammonium sulfate fractionation and Sepharose 6B chromatography, which resulted in a 6.69-fold increase in the specific activity and an 11.27% recovery. The enzyme was 58 kDa, lower than most dextranase, with an optimum temperature of 45 °C and an optimum pH of 6.0, and identified as an endodextranase. It was steady over a pH range from 3.0 to 10.0 and had reasonable thermal stability. The dextranase activity was increased by urea, which enhanced its activity to 115.35% and was conducive to clinical dextran production. Therefore, T. pinophilus H6 dextranase could show its superiority in practical applications.


Asunto(s)
Dextranasa/biosíntesis , Talaromyces/enzimología , Medios de Cultivo , Dextranos/química , Glucanos/química , Concentración de Iones de Hidrógeno , Hidrólisis , Microbiología Industrial , Peso Molecular , Microbiología del Suelo
16.
J Clin Ultrasound ; 45(5): 293-303, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28121016

RESUMEN

OBJECTIVE: Clinical decision making in children with congenital and acquired heart disease relies on measurements of cardiac structures using two-dimensional echocardiography. We aimed to establish z-score regression equations for right heart structures in healthy Chinese Han children. METHODS: Two-dimensional and M-mode echocardiography was performed in 515 patients. We measured the dimensions of the pulmonary valve annulus (PVA), main pulmonary artery (MPA), left pulmonary artery (LPA), right pulmonary artery (RPA), right ventricular outflow tract at end-diastole (RVOTd) and at end-systole (RVOTs), tricuspid valve annulus (TVA), right ventricular inflow tract at end-diastole (RVIDd) and at end-systole (RVIDs), and right atrium (RA). Regression analyses were conducted to relate the measurements of right heart structures to 4body surface area (BSA). Right ventricular outflow-tract fractional shortening (RVOTFS) was also calculated. Several models were used, and the best model was chosen to establish a z-score calculator. RESULTS: PVA, MPA, LPA, RPA, RVOTd, RVOTs, TVA, RVIDd, RVIDs, and RA (R2 = 0.786, 0.705, 0.728, 0.701, 0.706, 0.824, 0.804, 0.663, 0.626, and 0.793, respectively) had a cubic polynomial relationship with BSA; specifically, measurement (M) = ß0 + ß1 × BSA + ß2 × BSA2 + ß3 × BSA.3 RVOTFS (0.28 ± 0.02) fell within a narrow range (0.12-0.51). CONCLUSIONS: Our results provide reference values for z scores and regression equations for right heart structures in Han Chinese children. These data may help interpreting the routine clinical measurement of right heart structures in children with congenital or acquired heart disease. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:293-303, 2017.


Asunto(s)
Ecocardiografía/estadística & datos numéricos , Corazón/diagnóstico por imagen , Adolescente , Pueblo Asiatico , Niño , Preescolar , China , Ecocardiografía/métodos , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Valores de Referencia , Análisis de Regresión
17.
Langmuir ; 32(2): 460-7, 2016 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-26710830

RESUMEN

In this work, we report the preparation of complex nano-objects by means of a stepwise self-assembly of two polymer-polyoxometalate hybrids (PPHs) in solution. The PPHs are designed and synthesized by tethering two linear poly(ε-caprolactone)s (PCL) of different molecular weights (MW) on a complex of a Wells-Dawson-type polyoxometalate (POM) cluster and its countraions. The higher MW PCL-POM self-assembled into nanosheets, while the lower MW PCL-POM assembled into nanotubes just by altering the ratio of water in the DMF-water mixed solvent system. The two nano-objects have a similar membrane structure in which a PCL layer is sandwiched by the two POM-based complex layers. The PCL layer in the nanosheets is semicrystalline, while the PCL layer in the nanotubes is amorphous. We further exploited this MW-dependence to self-assemble the nanotubes on the nanosheet edges to create complex tube-graft-sheet nano-objects. We found that the nanotubes nucleate on the four {110} faces of the PCL crystal and then further grow along the crystallographic b-axis of the PCL crystal. Our findings offer hope for the further development of nano-objects with increasing complexity.

18.
Echocardiography ; 33(4): 606-17, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26606913

RESUMEN

BACKGROUND: The importance of left ventricular (LV) twisting has been recognized in various types of heart disease, but no studies have investigated twisting of functional single ventricle using echocardiography. This study aimed to evaluate LV twisting and dyssynchrony of children with single left ventricle (SLV) after the Fontan operation and explore the relationship between twisting motion and ventricular contractility using three-dimensional speckle tracking imaging (3DSTI). METHODS: Thirty-five children with SLV and 35 healthy children (controls) were enrolled. The patients were divided into wide and narrow QRS groups according to the QRS interval. Atrioventricular valve inflow velocity and tissue Doppler imaging velocity were obtained, and the Tei index was calculated. Apical rotation, basal rotation, twist, torsion, time to peak apical rotation, time to peak basal rotation, time to peak twist, apical-basal rotation delay, and the systolic dyssynchrony index (SDI) were measured by 3DSTI. RESULTS: Patients with SLV had significantly lower apical rotation (2.50 ± 2.25° vs. 4.85 ± 2.68°, P < 0.001), basal rotation (-3.46 ± 3.11° vs. -7.76 ± 2.11°, P < 0.001), twist (5.15 ± 4.75° vs. 12.19 ± 3.65°, P < 0.001), and torsion (1.04 ± 0.99°/cm vs. 2.37 ± 0.77°/cm, P < 0.001) compared to controls. Time to peak basal rotation, apical-basal rotation delay, and time to peak twist were significantly longer in patients. Apical rotation was significantly lower in the wide QRS group but similar in the narrow QRS group as compared to controls. Time to peak twist and apical-basal delay were significantly longer in the wide QRS group in contrast to the similar time in the narrow QRS group compared with controls. Among these twisting parameters, twist and torsion were most significantly correlated with left ventricular ejection fraction (LVEF), the Tei index, and SDI. Twist and age were significantly correlated. CONCLUSION: Twisting is reduced in children with SLV after the Fontan operation. Torsion is a good indicator of LV global function because of good reproducibility and its lack of association with age.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Procedimiento de Fontan/métodos , Ventrículos Cardíacos/anomalías , Ventrículos Cardíacos/cirugía , Anomalía Torsional/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Niño , Preescolar , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Lactante , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Anomalía Torsional/etiología , Anomalía Torsional/prevención & control , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología
19.
Echocardiography ; 32(10): 1554-63, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26099327

RESUMEN

BACKGROUND: Real time three-dimensional echocardiography (RT3DE) provides a reliable analysis of left ventricular (LV) volume. Despite a wide spectrum of tracking algorithms presently available, which software is most suitable for evaluating functional single left ventricle (FLSV) is unknown. Herein, we compared two of the most commonly used 3DE algorithms for quantification of LV volumes in the pediatric population with FLSV. METHODS: Thirty-six children with FLSV were prospectively enrolled. The LV volume analysis was performed on QLAB 8.1 (semiautomated border tracking) and TomTec 4D LV 3.0 (manual dominant border tracking) and compared with MRI as the reference standard. RESULTS: 3DE volume quantification was achieved for 32 children with QLAB and 34 children with TomTec. Analysis time was much shorter for QLAB than TomTec (4.8 ± 1.2 vs. 6.3 ± 1.8 minutes, P < 0.05). Ejection fraction (EF) by either 3DE modality was significantly lower than the published normal values (P < 0.01 for each). End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume, and EF calculated by both 3DE modalities underestimated MRI values. Compared to QLAB, TomTec showed better correlation and smaller intertechnique differences with MRI (the 95% limits of agreement, EDV: -20.84 to 5.18 mL in QLAB, -10.66 to 1.84 mL in TomTec; ESV: -8.94 to 3.07 mL in QLAB, -2.45 to 0.98 mL in TomTec; SV: -13.31 to 3.45 mL in QLAB, -9.34 to 2.0 mL in TomTec; EF: -12.07 to 7.76% in QLAB, -9.64 to 1.52% in TomTec), TomTec was more reproducible with better intraclass correlation coefficients and variation coefficients. CONCLUSIONS: Both 3DE modalities tend to underestimate LV volumes, but the correlation of LV volumes and EF between 3DE and MRI still holds well. Despite a longer operating time, TomTec analysis is more accurate and reproducible.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Ventrículos Cardíacos/anomalías , Disfunción Ventricular Izquierda/diagnóstico por imagen , Algoritmos , Niño , Preescolar , Femenino , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/cirugía , Humanos , Interpretación de Imagen Asistida por Computador , Lactante , Recién Nacido , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/cirugía
20.
Paediatr Anaesth ; 25(2): 167-73, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25039420

RESUMEN

BACKGROUND: We evaluated the use of bioreactance-based noninvasive cardiac output (CO) monitoring technique (NICOM(™), CO(NICOM)) in pediatric patients with or without ventricular septal defect (VSD) during anesthesia induction to determine its agreement with the measurements assessed by echocardiography (echo, CO(ECHO)). METHODS: Twenty-eight pediatric patients with normal heart anatomy (group NHA) and 32 with isolated ventricular septal defects (group VSD) were included in this study. The cardiac output was measured simultaneously in minute-by-minute using NICOM and echo (Simpson's rule) during anesthesia induction and intubation. Linear regression and revised Bland-Altman analyses were performed to evaluate the agreement by comparing the paired CO results. The mean percent error ((CO(ECHO)-CO(NICOM))/CO(ECHO) × 100%) was used to assess the impact of congenital heart disease on the agreement. RESULTS: The measurements of CO by NICOM and echo techniques were highly correlated in group NHA (γ = 0.96, P < 0.005) and VSD (γ = 0.84, P < 0.005). The mean bias (CO(ECHO) - CO(NICOM)) between the two methods was 0.03 and 0.31 l·min(-1) with the limits of agreement (LOA) -0.29 to +0.35 l·min(-1) and -0.44 to +1.05 l·min(-1), which include 96.9% (31/32) and 89.3% (25/28) of all patients' different data in group NHA and VSD, respectively. The median percent errors were significantly lower at all time points in group NHA than those in group VSD (all P < 0.05). CONCLUSION: In children without heart defects, the CO measured by NICOM shows a good agreement with the echo during anesthesia induction. The NICOM technique underestimates echo although a strong correlation exists between two methods in children with ventricular septal defect.


Asunto(s)
Anestesia , Ecocardiografía , Defectos del Tabique Interventricular/fisiopatología , Monitoreo Fisiológico/métodos , Gasto Cardíaco/fisiología , Preescolar , Femenino , Defectos del Tabique Interventricular/cirugía , Humanos , Lactante , Masculino , Reproducibilidad de los Resultados , Termodilución/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA