Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am Heart J ; 274: 65-74, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38701961

RESUMEN

BACKGROUND: There has not been a consensus on the prothesis sizing strategy in type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). Modifications to standard annular sizing strategies might be required due to the distinct anatomical characteristics. We have devised a downsizing strategy for TAVR using a self-expanding valve specifically for patients with type 0 bicuspid AS. The primary aim of this study is to compare the safety and efficacy of downsizing strategy with the Standard Annulus Sizing Strategy in TAVR for patients with type 0 bicuspid AS. TRIAL DESIGN: It is a prospective, multi-center, superiority, single-blinded, randomized controlled trial comparing the Down Sizing and Standard Annulus Sizing Strategy in patients with type 0 bicuspid aortic stenosis undergoing transcatheter aortic valve replacement. Eligible participants will include patients with severe type 0 bicuspid AS, as defined by criteria such as mean gradient across aortic valve ≥40 mmHg, peak aortic jet velocity ≥4.0 m/s, aortic valve area (AVA) ≤1.0 cm², or AVA index ≤0.6 cm2/m2. These patients will be randomly assigned, in a 1:1 ratio, to either the Down Sizing Strategy group or the Standard Sizing Strategy group. In the Down Sizing Strategy group, a valve one size smaller will be implanted if the "waist sign" manifests along with less than mild regurgitation during balloon pre-dilatation. The primary end point of the study is a composite of VARC-3 defined device success, absence of both permanent pacemaker implantation due to high-degree atrioventricular block and new-onset complete left bundle branch block. CONCLUSION: This study will compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy and provide valuable insights into the optimal approach for sizing in TAVR patients with type 0 bicuspid AS. We hypothesize that the Down Sizing Strategy will demonstrate superiority when compared to the Standard Annulus Sizing Strategy. (Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0) (TAILOR-TAVR), NCT05511792).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Estudios Prospectivos , Método Simple Ciego , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Masculino , Femenino
2.
Sensors (Basel) ; 24(12)2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38931641

RESUMEN

Few-layer black phosphorus (FLBP) is a highly promising material for high sensitivity label-free surface plasmon resonance (SPR) sensors due to its exceptional electrical, optical, and mechanical properties. FLBP exhibits inherent anisotropy with different refractive indices along its two main crystal orientations, the zigzag and armchair axes. However, this anisotropic property is often overlooked in FLBP-based sensors. In this study, we conducted a comprehensive investigation of the SPR reflectivity and phase in a BK7-Ag-FLBP structure to understand the influence of the stacking sequence and the number of FLBP layers on the sensing performance. Clear resonant angle shifts caused by different stacking sequences of FLBP could be observed both theoretically and experimentally. In the theoretical study, the highest reflective and phase sensitivities were achieved with a 12-layer black phosphorus (BP) structure. The reflectivity sensitivity reached 287.9°/refractive index units (RIU) with the zz stacking 12-layer BP film exhibiting a sensitivity 76°/RIU higher than the ac stacking structure. Similarly, the phase sensitivity reached 1162°/RIU with the zz stacking 12-layer BP structure showing a sensitivity 276.9°/RIU higher than the ac stacking structure. The electric field distribution of the 12-layer BP structure with four different stacking sequences has also been analyzed. In the experiment study, the well-known Attenuated Total Reflection (ATR) θ-2θ SPR setup is utilized to detect the reflectivity and phase of BK7-Ag-FLBP structures. The FLBP samples with the same thickness but different stacking sequences show significant resonant angle shift (0.275°) and maximum phase difference variation (34.6°). The FLBP sample thickness and crystal orientations have been demonstrated using the angular-resolved polarized Raman spectroscopy (ARPRS). These theoretical and experimental results provide strong evidence that the stacking sequences of FLBP have a significant impact on the sensing performance of SPR sensors. By harnessing the anisotropic properties of materials like FLBP, novel structures of anisotropic-2D material-based SPR sensors could open up exciting possibilities for innovative applications.

3.
J Cardiovasc Electrophysiol ; 34(11): 2406-2409, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37855612

RESUMEN

INTRODUCTION: This study describes a rare case of concealed epicardial accessory pathway (AP) successfully ablated using ethanol infusion (EI) through a variant vessel connecting the right atrium (RA) and the right ventricle (RV) surface. METHODS AND RESULTS: A 58-year-old male referred to our hospital for prior failed AP ablation. Cardiac-enhanced computerized tomography scan showed there was a variant vessel at the tip of right atrial appendage and a pulmonary artery (PA)-RA fistula at the roof of RA. The earliest activation was present at the site of the PA-RA fistula. A selective angiography showed that a small branch of the variant vessel covered the earliest excitation site of the AP. EI into this branch successfully repressed the AP without any recurrences within a follow-up period of 3 months. CONCLUSION: Endocardial ablation is challenging for epicardial APs related to cardiac structural variations. If small vascular branches near the earliest activation site can be found, EI can successfully ablate these types of epicardial APs.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Fístula , Masculino , Humanos , Persona de Mediana Edad , Ablación por Catéter/métodos , Fascículo Atrioventricular Accesorio/diagnóstico por imagen , Fascículo Atrioventricular Accesorio/cirugía , Fascículo Atrioventricular , Atrios Cardíacos , Electrocardiografía
4.
FASEB J ; 35(2): e21183, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33184978

RESUMEN

Calcific aortic valve disease (CAVD) is the most common valvular heart disease in adults. The cellular mechanisms of CAVD are still unknown, but accumulating evidence has revealed that osteogenic differentiation of human valve interstitial cells (hVICs) plays an important role in CAVD. Thus, we aimed to investigate the function of estrogen-related receptor α (ERRα) in the osteogenic differentiation of hVICs. We found that the level of ERRα was significantly increased in CAVD samples compared to normal controls. In addition, ERRα was significantly upregulated during hVIC osteogenic differentiation in vitro. Gain- and loss-of-function experiments were performed to identify the function of ERRα in hVIC calcification in vitro. Inhibition of endogenous ERRα attenuated hVIC calcification, whereas overexpression of ERRα in hVICs promoted this process. RNA sequencing results suggested that heme oxygenase-1 (Hmox1) was a downstream target of ERRα, which was further confirmed by western blotting. Additionally, we also found that downregulation of Hmox1 by shHmox1 efficiently reversed the inhibition of calcification induced by ERRα shRNA in hVICs. ChIP-qPCR and luciferase assays indicated that Hmox1 was negatively regulated by ERRα. We found that overexpression of Hmox1 or its substrates significantly inhibited hVIC calcification in vitro. In conclusion, we found that knockdown of ERRα can inhibit hVIC calcification through upregulating Hmox1 and that ERRα and Hmox1 are potential targets for the treatment of CAVD.


Asunto(s)
Estenosis de la Válvula Aórtica/metabolismo , Válvula Aórtica/patología , Calcinosis/metabolismo , Técnicas de Silenciamiento del Gen , Hemo-Oxigenasa 1/metabolismo , Receptores de Estrógenos/genética , Receptores de Estrógenos/metabolismo , Anciano , Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/patología , Calcinosis/patología , Diferenciación Celular/genética , Femenino , Células HEK293 , Hemo-Oxigenasa 1/genética , Humanos , Masculino , Persona de Mediana Edad , Osteogénesis/genética , Transfección , Regulación hacia Arriba/genética , Calcificación Vascular , Receptor Relacionado con Estrógeno ERRalfa
5.
Neurochem Res ; 47(8): 2198-2210, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35513760

RESUMEN

The antiknock additive methylcyclopentadienyl manganese tricarbonyl (MMT) is an organic manganese(Mn) compound. Mn neurotoxicity caused by occupational Mn exposure (mostly inorganic MnCl2) is associated with motor and cognitive disturbances, referred to as Manganism. However, the impact of environmentally relevant Mn exposure on MMT-induced Manganism is poorly understood. In this investigation, we studied the effects of MMT on motor function and brain structure, and compared its effects with those of inorganic MnCl2. After adaptive feeding for 7 days, male and female Sprague-Dawley (SD) rats in the MMT-treated groups and positive control group were treated for 8 weeks with MMT (1, 2 and 4 mg/kg/i.g.) or MnCl2·4H2O (200 mg/kg/i.g.). Mn content in blood, liver, spleen and distinct brain regions was determined by inductively coupled plasma-mass spectrometer (ICP-MS). We found that MMT and MnCl2 exposure led to slower body-weight-gain in female rats, impaired motor and balance function and spatial learning and memory both in male and female rats. HE staining showed that MMT and MnCl2 led to altered structure of the substantia nigra pars compacta (SNpc), and Nissl staining corroborated MMT's propensity to damage the SNpc both in male and female rat. In addition, Immunostaining of the SNpc showed decreased TH-positive neurons in MMT- and MnCl2-treated rats, concomitant with Iba1 activation in microglia. Moreover, no statistically significant difference was noted between the rats in the H-MMT and MnCl2 groups. In summary, these findings suggest that MMT and MnCl2 exposure cause ultrastructural changes in the SNpc neurons culminating in altered motor behavior and cognition, suggesting that altered SNpc structure and function may underline the motor and cognitive deficits inherent to Manganism, and accounting for MMT and MnCl2's manifestations of atypical parkinsonism.


Asunto(s)
Intoxicación por Manganeso , Manganeso , Animales , Cloruros , Femenino , Masculino , Manganeso/toxicidad , Compuestos de Manganeso , Ratas , Ratas Sprague-Dawley , Sustancia Negra
6.
Catheter Cardiovasc Interv ; 99 Suppl 1: 1482-1489, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35324060

RESUMEN

OBJECTIVES: We aimed to validate a novel staging system for aortic stenosis (AS) in a Chinese patient cohort undergoing transcatheter aortic valve replacement (TAVR), and to compare this classification system to the traditional Society of Thoracic Surgeons (STS) score for TAVR risk stratification. BACKGROUND: A novel staging system for AS based on the extent of cardiac damage upon echocardiography was recently proposed. METHODS: Patients were prospectively enrolled into the Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population and analyzed retrospectively following additional exclusion criteria. On the basis of echocardiographic findings of cardiac damage, patients were classified into five stages (0-4). RESULTS: A total of 427 patients were included in the current analysis. Forty-eight deaths occurred during a median follow-up of 730 days following TAVR. The staging system showed a statistically significant association between cardiac damage and all-cause mortality; advanced stages were associated with higher mortality. In a multivariate-adjusted Cox proportional hazards regression model, stage and STS scores served as risk factors for 2-year mortality. Each increment in the staging class was associated with an increased risk of mortality (hazard ratio, 1.275; 95% confidence interval [CI], 1.052-1.545). Receiver operating characteristic (ROC) curves were plotted for stage (area under the curve, 0.644; 95% CI, 0.562-0.725) and STS score (0.661; 0.573-0.749), and with no statistically significant differences between ROC curves (p = 0.920). CONCLUSIONS: We validated a novel staging system as a key risk factor for 2-year mortality in a Chinese TAVR patient cohort. Efficacy for risk stratification was comparable to the STS score.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , China , Humanos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
BMC Cardiovasc Disord ; 22(1): 164, 2022 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413789

RESUMEN

BACKGROUND: Unlike N-terminal pro-B-type natriuretic peptide (NT-proBNP), which have been extensively studied, little is known about the role of N-terminal pro-C-type natriuretic peptide (NT-proCNP) for predicting survival post transcatheter aortic valve replacement (TAVR). METHODS: A total of 309 patients were included in the analysis. Patients were grouped into quartiles (Q1-4) according to the baseline NT-proCNP value. Blood for NT-proCNP analysis was obtained prior to TAVR procedure. The primary endpoint was mortality after a median follow-up of 32 months. Multivariable Cox proportional hazards regression models analyzed prognostic factors. The predictive capability was compared between NT-proBNP and NT-proCNP using receiver operator curve (ROC) analysis. RESULTS: A total of 309 subjects with the mean age of 76.8 ± 6.3 years, among whom 58.6% were male, were included in the analysis. A total of 58 (18.8%) patients died during follow-up. Cox multivariable analyses indicated society of thoracic surgeons (STS)-score was a strong independent predictor for mortality (hazard ratio (HR) 1.08, 95% confidential interval (CI) 1.05-1.12, P < 0.001). Elevated NT-proCNP was associated with a higher risk of cardiovascular mortality (HR 1.02, 95% CI 1.00-1.03, P = 0.025) and All-cause mortality (HR 1.01, 95% CI 1.00-1.03, P = 0.027), whereas NT-proBNP showed a small effect size on mortality. ROC analysis indicated that NT-proCNP was superior to NT-proBNP for TAVR risk evaluation in patients with left ventricular ejection fraction (LVEF) < 50% [(Area under the curve (AUC)-values of 0.79 (0.69; 0.87) vs. 0.59 (0.48; 0.69), P = 0.0453]. CONCLUSIONS: NT-proCNP and STS-Score were the independent prognostic factors of mortality among TAVR patients. Furthermore, NT-proCNP was superior to NT-proBNP for TAVR risk evaluation in patients with LVEF < 50%. Trial registration NCT02803294, 16/06/2016.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Biomarcadores , Diuréticos , Humanos , Masculino , Péptido Natriurético Encefálico , Péptido Natriurético Tipo-C , Fragmentos de Péptidos , Pronóstico , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Vasodilatadores , Función Ventricular Izquierda
8.
J Mol Cell Cardiol ; 150: 54-64, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33045251

RESUMEN

AIMS: Calcific aortic valve disease (CAVD) is a primary cause of cardiovascular mortality; however, its mechanisms are unknown. Currently, no effective pharmacotherapy is available for CAVD. Aldo-keto reductase family 1 member B (Akr1B1) has been identified as a potential therapeutic target for valve interstitial cell calcification. Herein, we hypothesized that inhibition of Akr1B1 can attenuate aortic valve calcification. METHODS AND RESULTS: Normal and degenerative tricuspid calcific valves from human samples were analyzed by immunoblotting and immunohistochemistry. The results showed significant upregulation of Akr1B1 in CAVD leaflets. Akr1B1 inhibition attenuated calcification of aortic valve interstitial cells in osteogenic medium. In contrast, overexpression of Akr1B1 aggravated calcification in osteogenic medium. Mechanistically, using RNA sequencing (RNAseq), we revealed that Hippo-YAP signaling functions downstream of Akr1B1. Furthermore, we established that the protein level of the Hippo-YAP signaling effector active-YAP had a positive correlation with Akr1B1. Suppression of YAP reversed Akr1B1 overexpression-induced Runx2 upregulation. Moreover, YAP activated the Runx2 promoter through TEAD1 in a manner mediated by ChIP and luciferase reporter systems. Animal experiments showed that the Akr1B1 inhibitor epalrestat attenuated aortic valve calcification induced by a Western diet in LDLR-/- mice. CONCLUSION: This study demonstrates that inhibition of Akr1B1 can attenuate the degree of calcification both in vitro and in vivo. The Akr1B1 inhibitor epalrestat may be a potential treatment option for CAVD.


Asunto(s)
Aldehído Reductasa/metabolismo , Aldo-Ceto Reductasas/metabolismo , Estenosis de la Válvula Aórtica/enzimología , Estenosis de la Válvula Aórtica/patología , Válvula Aórtica/enzimología , Válvula Aórtica/patología , Calcinosis/enzimología , Calcinosis/patología , Proteínas Serina-Treonina Quinasas/metabolismo , Transducción de Señal , Proteínas Adaptadoras Transductoras de Señales/metabolismo , Aldehído Reductasa/antagonistas & inhibidores , Animales , Válvula Aórtica/efectos de los fármacos , Subunidad alfa 1 del Factor de Unión al Sitio Principal/metabolismo , Inhibidores Enzimáticos/farmacología , Técnicas de Silenciamiento del Gen , Humanos , Lentivirus/metabolismo , Ratones , Osteogénesis/efectos de los fármacos , Transducción de Señal/efectos de los fármacos , Factores de Transcripción/metabolismo , Proteínas Señalizadoras YAP
9.
Int J Clin Pract ; 75(12): e14905, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34547167

RESUMEN

OBJECTIVE: To explore the relationship between mild cognitive impairment (MCI) and sense organs functional deficit in community elderly people. METHODS: A total of 3095 community elderly people above 60 years in Hebei Province were selected by cross-sectional random cluster sampling method, who were evaluated face-to-face for general demographic data, the condition of sense organs functional deficit (vision, hearing, gustation, olfactory sensation, taste) and cognitive function by Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA). RESULTS: A total of 3075 valid questionnaires were obtained. (a) 1368 old people (44.49%) were defined with sense organs functional deficit (defined as one or more of glaucoma, fundus disease, hearing impairment, olfactory disorder and taste disorder) in 3095 elderly people. According to questionnaires, MCI was diagnosed in 689 of 3075 participants (22.41%). The hearing disorder and glaucoma of MCI group were higher than that of the normal control group (X2 were 5.998 and 7.430, respectively, P were .014 and .006, respectively). (b) The MMSE score of the hearing disorder were significantly lower than those of non-hearing disorder group (t = 2.046, P = .041). (c) Multinomial logistics regression analysis was applied by MCI as the dependent variable and the various sensory organs defects as independent variables. The hearing impairment (Wald = 8.582, P = .003, OR = 1.485, 95% CI: 1.140-1.934) and glaucoma (Wald = 8.020, P = .005, OR = 1.847, 95% CI: 1.208-2.824) were associated with MCI. CONCLUSION: The sensory organs functional defects is associated with the mild cognitive impartment in Chinese elderly, especially in vision and hearing disorder.


Asunto(s)
Cognición , Órganos de los Sentidos , Anciano , China/epidemiología , Estudios Transversales , Humanos , Pruebas Neuropsicológicas , Factores de Riesgo
10.
Cardiology ; 145(1): 27-34, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31722361

RESUMEN

AIMS: Permanent pacemaker (PPM) implantation is one of the most common complications after transcatheter aortic valve replacement (TAVR). We studied the incidence of PPM implantation and identified the predictors in patients who underwent TAVR in a Chinese population. METHODS AND RESULTS: A total of 256 patients who underwent TAVR with self-expandable valves were included. The incidence of PPM implantation in our study population was 14.8%. In patients who received PPM implantation, the proportion of bicuspid aortic valve (BAV) patients was much lower compared to tricuspid aortic valve (TAV) patients (18.4 vs. 81.6%, p < 0.05). Patients with BAV were associated with a significantly lower PPM implantation rate and shallower implantation depth compared to patients with TAV (6.4 vs. 21.7% and 4.2 ± 4.4 vs. 6.2 ± 5.0 mm, respectively, p < 0.05 for both). In the multivariable logistic regression analysis, prior right bundle branch block (RBBB; OR 8.3, 95% CI 2.2-32.1, p < 0.05), implantation depth (OR 1.3, 95% CI 1.1-1.5, p = 0.01), and TAV (OR 4.7, 95% CI 1.5-14.4, p < 0.05) were independent predictors of PPM implantation after TAVR. There was no difference in 30-day and 1-year all-cause mortality between the 2 groups. CONCLUSIONS: The incidence of PPM implantation in patients with self-expandable valves after TAVR was 14.8% in our cohort study. Independent predictors of PPM implantation included prior RBBB, TAV, and implantation depth at the noncoronary sinus side. TAVR in BAV with a supra-annular structure-based sizing strategy might decrease the risk of PPM implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial/mortalidad , China/epidemiología , Electrocardiografía , Femenino , Prótesis Valvulares Cardíacas , Humanos , Incidencia , Modelos Logísticos , Masculino , Análisis Multivariante , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
11.
Herz ; 45(8): 726-738, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31555891

RESUMEN

BACKGROUND: Obstructive sleep apnea syndrome (OSAS) is associated with cardiovascular mortality and morbidity. Several studies have reported that it affects the left ventricle; however, large randomized controlled trials are lacking. The current study aimed to summarize the association between OSAS and left ventricular (LV) structure and function. METHODS: Electronic databases (PubMed, Embase, and Cochrane) and references were searched for articles published until March 2018. A systematic review and meta-analysis were performed to assess LV structure and function in OSAS patients based on echocardiography. RESULTS: In total, 17 studies with 747 OSAS patients and 426 control participants were included. Patients with OSAS showed an increase in LV diastolic diameter (weighted mean difference [WMD], 95% CI: 1.24 [0.68, 1.80]; p < 0.001), LV systolic diameter (WMD, 95% CI: 1.14 [0.47, 1.81]; p = 0.001), and LV mass (WMD, 95% CI: 35.34 [20.67, 50.00]; p < 0.001). In addition, left ventricular ejection fraction (LVEF) significantly decreased in the OSAS group compared with the controls (WMD, 95% CIs: -1.82 [-2.76, -0.87]; p < 0.001), and the reduction in LVEF was consistent with the severity of OSAS. The OSAS group also showed an increase in left atrial diameter (WMD, 95% CI: 2.13 [1.48, 2.77]; p < 0.001) and left atrial diameter volume index (WMD, 95% CIs: 3.96 [3.32, 4.61]; p < 0.001). CONCLUSION: Obstructive sleep apnea syndrome leads to atrial dilatation, left ventricular hypertrophy, enlargement, mass increase and reduction of systolic function. Treatments for OSAS might be beneficial for the preservation of left cardiac structure and function.


Asunto(s)
Apnea Obstructiva del Sueño , Disfunción Ventricular Izquierda , Ecocardiografía , Humanos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Remodelación Ventricular
12.
Rapid Commun Mass Spectrom ; 33(9): 883-893, 2019 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-30771236

RESUMEN

RATIONALE: Discriminating between aglycone-substituted and saccharide-substituted saikosaponins by liquid chromatography/tandem mass spectrometry (LC/MSn ) is a long-standing issue that is still to be resolved. It is necessary to characterize the two types of substituted saikosaponins taking into consideration the potential significant difference in their bioactivity. METHODS: Taking the substituents malonyl and acetyl as examples, we developed a MS strategy to discriminate between the aglycone-substituted and saccharide-substituted saikosaponins through comparing their Y0 - nH2 O (n = 1-2) ions from the protonated molecules in the full-scan mass spectra and their B ions in the MS2 spectra of sodium-adduct molecules in the positive mode. RESULTS: The deprotonated molecules of the aglycone-substituted saikosaponins presented similar fragmentation patterns to those of saccharide-substituted ones in the negative mode, which could not discriminate whether the substitutes were located on the aglycone or the saccharide. In contrast, the Y0 - nH2 O (n = 1-2) ions containing or no substituent were observed respectively in the mass fragmentation of the protonated molecules of aglycone-substituted or saccharide-substituted saikosaponins in the positive mode. In addition, the B ions containing or no substituent were observed respectively in the mass fragmentation of the sodium-adduct molecules of the saccharide-substituted or aglycone-substituted saikosaponins in the positive mode. Two aglycone-malonylated saikosaponins were reported for the first time. CONCLUSIONS: Whether the substituents were located on the aglycone or the saccharide could be determined according to the Y0 - nH2 O (n = 1-2) ions from the protonated molecules in the full-scan mass spectra and the B ions in the MS2 spectra of sodium-adduct molecules in the positive mode. Our results have updated the mass fragmentation patterns of substituted saikosaponins, which is helpful for the quality control of pharmaceutical preparations containing saikosaponins. More importantly, this MS strategy should be able to be extended to characterize other substituted saponins of bioactive significance in future studies.

13.
Sensors (Basel) ; 20(1)2019 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-31877831

RESUMEN

Flexible electronic devices are developing rapidly, especially in medical applications. This paper reports an arrayed flexible piezoelectric micromachined ultrasonic transducer (FPMUT) with a sandwich structure for adjuvant treatment of bone injury. To make the device conformable and stretchable for attaching to the skin surface, the flexible substrate of polydimethylsiloxane (PDMS) was combined with the flexible metal line interconnection between the bulk lead zirconate titanate (PZT) arrays. Simulations and experiments were carried out to verify the resonant frequency and tensile property of the reported FPMUT device. The device had a resonant frequency of 321.15 KHz and a maximum sound pressure level (SPL) of 180.19 dB at the distance of 5 cm in water. In addition, detailed experiments were carried out to test its acoustic performance with different pork tissues, and the results indicated good ultrasound penetration. These findings confirm that the FPMUT shows unique advantages for adjuvant treatment of bone injury.


Asunto(s)
Plomo/química , Titanio/química , Transductores , Ultrasonografía/métodos , Circonio/química , Animales , Enfermedades Óseas/terapia , Dimetilpolisiloxanos/química , Humanos , Terapia por Radiofrecuencia/instrumentación , Terapia por Radiofrecuencia/métodos , Fenómenos Fisiológicos de la Piel , Porcinos , Resistencia a la Tracción , Ultrasonografía/instrumentación , Agua/química
14.
Catheter Cardiovasc Interv ; 91(5): 986-994, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-29399947

RESUMEN

OBJECTIVES: To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). BACKGROUND: Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. METHODS: Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. RESULTS: Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. CONCLUSIONS: A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Toma de Decisiones Clínicas , Ecocardiografía , Estudios de Factibilidad , Femenino , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Cardiology ; 141(3): 132-140, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30517917

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a recent and an effective treatment option for high- or extreme-surgical-risk patients with symptomatic severe aortic stenosis. However, pure severe native aortic valve regurgitation (NAVR) without aortic stenosis remains a contraindication to TAVR. The aim of our systemic review analysis was to evaluate TAVR in patients with pure NAVR. METHODS: We searched the published articles in the PubMed and Web of Science databases (2002-2017) using the Boolean operators for studies of NAVR patients undergoing TAVR. Reference lists of all returned articles were searched recursively for other relevant citations. Pooled estimates were calculated using a random-effects meta-analysis. RESULTS: Finally, a total of 10 studies were included in this analysis. The CoreValve was more frequently used with a lower rate of device success and a higher rate of residual aortic regurgitation. The new-generation transcatheter heart valves (THVs) performed a significantly higher rate with less residual aortic regurgitation and a success rate close to 100%. The 30-day all-cause mortality rates ranged from 0 to 30% with an estimate summary rate of 9% (95% CI: 5-15%; I2 = 33%). Cerebrovascular events, major or life-threatening bleeding, major vascular complications, acute kidney disease, and new permanent pacemaker implantation occurred similarly in both the new- and old-generation THV devices. CONCLUSIONS: Aortic regurgitation remains a challenging pathology for TAVR. TAVR is a feasible and reasonable option for carefully selected patients with pure aortic regurgitation.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Humanos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
16.
Cardiology ; 139(3): 151-158, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29353286

RESUMEN

OBJECTIVES: The importance of thrombocytopenia (TP) has been discussed previously. However, data are still limited, especially on predictors of TP. We sought to investigate predictors of TP after transcatheter aortic valve replacement (TAVR), in particular, clinically significant TP. METHODS: We reviewed a total of 123 consecutive patients undergoing TAVR in our medical center. They were stratified into 3 groups according to the nadir platelet count post-TAVR: no/mild TP, moderate TP, and severe TP. Clinically significant TP, also known as major TP, was defined as moderate-to-severe TP (a nadir platelet count <100 × 109/L and a >50% decrease in platelet count). RESULTS: Baseline platelet, baseline hemoglobin, general anesthesia (GA), valve malpositioning and post-TAVR left ventricular ejection fraction were found to be predictors of post-TAVR nadir platelet count. Major TP was associated with a higher risk of major bleeding (OR 3.524, 95% CI 1.546-8.031) and 1-month mortality (OR 11.226, 95% CI 1.208-104.328). Age (OR 1.110, 95% CI 1.014-1.215) and GA (OR 6.494, 95% CI 2.058-20.408) were predictors of major TP. CONCLUSION: Post-TAVR nadir platelet count can be predicted based on baseline and procedural data. Old age and GA contribute to clinically significant TP.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Trombocitopenia/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , China , Femenino , Mortalidad Hospitalaria , Humanos , Modelos Logísticos , Masculino , Análisis Multivariante , Recuento de Plaquetas , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Función Ventricular Izquierda
19.
Chem Pharm Bull (Tokyo) ; 63(5): 388-92, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25765061

RESUMEN

Four new triterpenoid saponins, Catunaroside I [3-O-ß-D-glucopyranosyl-(1→3)-ß-D-glucopyranosyl-arjunic acid 28-O-ß-D-glucopyranoside] (1), Catunaroside J [3-O-ß-D-glucopyranosyl-(1→2)-[ß-D-glucopyranosyl-(1→3)]-ß-D-glucopyranosyl-arjunic acid 28-O-ß-D-glucopyranoside] (2), Catunaroside K [3-O-ß-D-glucopyranosyl-(1→2)-[ß-D-glucopyranosyl-(1→3)]-ß-D-glucopyranosyl-tormentic acid] (3), and Catunaroside L [3-O-ß-D-glucopyranosyl-(1→2)-[ß-D-glucopyranosyl-(1→3)]-ß-D-glucopyranosyl-pomolic acid] (4), and two known triterpenoid saponin Arjunetoside (5) and Randiasaponin VII (6), were isolated from the stem bark of Catunaregam spinosa. Their structures were elucidated on the basis of their spectral data and chemical evidence.


Asunto(s)
Corteza de la Planta/química , Rubiaceae/química , Saponinas/química , Triterpenos/química , Estructura Molecular
20.
Yao Xue Xue Bao ; 50(2): 191-8, 2015 Feb.
Artículo en Zh | MEDLINE | ID: mdl-25975027

RESUMEN

A series of [1,3]dioxolo[4,5-f]isoindolone derivatives were designed, synthesized and evaluated as inhibitors of acetylcholinesterases (AChE). Furthermore, their effects on memory impairment of mice induced by scopolamine were investigated with step-through test. The results suggested that most of the target compounds exhibited potential inhibition on AChE with IC50 values at micromolar range. Compounds I1 (IC50 value of 0.086 µmol · L(-1)) and I2 (IC50 value of 0.080 µmol · L(-1)) showed the strongest AChE inhibitory activity, which are equipotent to donepezil (IC50 value of 0.094 µmol · L(-1)). Moreover, compounds I1-I4 could improve the memory impairment induced by scopolamine in mice.


Asunto(s)
Inhibidores de la Colinesterasa/química , Dioxoles/síntesis química , Diseño de Fármacos , Isoindoles/química , Isoindoles/síntesis química , Animales , Inhibidores de la Colinesterasa/síntesis química , Dioxoles/química , Donepezilo , Indanos , Concentración 50 Inhibidora , Trastornos de la Memoria/tratamiento farmacológico , Ratones , Piperidinas , Escopolamina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA