Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Monit Comput ; 32(5): 825-832, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29149433

RESUMEN

Animal studies suggest that dynamic predictors remain useful in patients with pneumoperitoneum, but human data is conflicting. Our aim was to determine predictive values of pulse pressure variation (PPV) and stroke volume variation (SVV) in patients with pneumoperitoneum using LiDCORapid™ haemodynamic monitor. Standardised fluid challenges of colloid were administered to patients undergoing laparoscopic procedures, one fluid challenge per patient. Intra-abdominal pressure was automatically held at 12 mmHg. Fluid responsiveness was defined as an increase in nominal stroke index (nSI) ≥ 10%. Linear regression was used to assess the ability of PPV and SVV to track the changes of nSI and logistic regression and area under the receiver operating curve (AUROC) to assess the predictive value of PPV and SVV for fluid responsiveness. Threshold values for PPV and SVV were obtained using the "gray zone" approach. A p < 0.05 was considered as statistically significant. 56 patients were included in analysis. 41 patients (73%) responded to fluids. Both PPV and SVV tracked changes in nSI (Spearman correlation coefficients 0.34 for PPV and 0.53 for SVV). Odds ratio for fluid responsiveness for PPV was 1.163 (95% CI 1.01-1.34) and for SVV 1.341 (95% CI 1.10-1.63). PPV achieved an AUROC of 0.674 (95% CI 0.518-0.830) and SVV 0.80 (95% CI 0.668-0.932). The gray zone of PPV ranged between 6.5 and 20.5% and that of SVV between 7.5 and 13%. During pneumoperitoneum, as measured by LiDCORapid™, PPV and SVV can predict fluid responsiveness, however their sensitivity is lower than the one reported in conditions without pneumoperitoneum. Trial registry number: (with the Australian New Zealand Clinical Trials Registry): ACTRN12612000456853.


Asunto(s)
Fluidoterapia , Monitorización Hemodinámica/métodos , Neumoperitoneo/fisiopatología , Neumoperitoneo/terapia , Adulto , Anciano , Análisis de Varianza , Presión Sanguínea/fisiología , Femenino , Monitorización Hemodinámica/estadística & datos numéricos , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Volumen Sistólico/fisiología , Volumen de Ventilación Pulmonar/fisiología
2.
Ther Hypothermia Temp Manag ; 9(1): 86-89, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30096259

RESUMEN

We describe a patient with severe accidental hypothermia (≤25.4°C) and prolonged refractory ventricular fibrillation, lasting at least 4 hours and 8 minutes, who underwent cardiopulmonary resuscitation with extracorporeal membrane oxygenation and survived without neurologic deficit.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Oxigenación por Membrana Extracorpórea/métodos , Hipotermia/terapia , Fibrilación Ventricular/terapia , Accidentes , Humanos , Hipotermia/complicaciones , Masculino , Persona de Mediana Edad , Recalentamiento , Resultado del Tratamiento , Fibrilación Ventricular/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA