Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
J Appl Biomech ; 34(6): 496-502, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29809082

RESUMEN

Musculoskeletal modeling and simulations have become popular tools for analyzing human movements. However, end users are often not aware of underlying modeling and computational assumptions. This study investigates how these assumptions affect biomechanical gait analysis outcomes performed with Human Body Model and the OpenSim gait2392 model. The authors compared joint kinematics, kinetics, and muscle forces resulting from processing data from 7 healthy adults with both models. Although outcome variables had similar patterns, there were statistically significant differences in joint kinematics (maximal difference: 9.8° [1.5°] in sagittal plane hip rotation), kinetics (maximal difference: 0.36 [0.10] N·m/kg in sagittal plane hip moment), and muscle forces (maximal difference: 8.51 [1.80] N/kg for psoas). These differences might be explained by differences in hip and knee joint center locations up to 2.4 (0.5) and 1.9 (0.2) cm in the posteroanterior and inferosuperior directions, respectively, and by the offset in pelvic reference frames of about 10° around the mediolateral axis. The choice of model may not influence the conclusions in clinical settings, where the focus is on interpreting deviations from the reference data, but it will affect the conclusions of mechanical analyses in which the goal is to obtain accurate estimates of kinematics and loading.

2.
J Biomech ; 75: 96-101, 2018 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-29789150

RESUMEN

Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled surface movements, or in conditions where the foundation is moving or not sufficiently rigid. Here we present a linear model to predict the inertial and gravitational artifacts using accelerometer signals. The model is first calibrated with data collected from random movements of the unloaded system and then used to compensate for the errors in another trial. The method was tested experimentally on an instrumented force treadmill capable of dynamic mediolateral translation and sagittal pitch. The compensation was evaluated in five experimental conditions, including platform motions induced by actuators, by motor vibration, and by human ground reaction forces. In the test that included all sources of platform motion, the root-mean-square (RMS) errors were 39.0 N and 15.3 N m in force and moment, before compensation, and 1.6 N and 1.1 N m, after compensation. A sensitivity analysis was performed to determine the effect on estimating joint moments during human gait. Joint moment errors in hip, knee, and ankle were initially 53.80 N m, 32.69 N m, and 19.10 N m, and reduced to 1.67 N m, 1.37 N m, and 1.13 N m with our method. It was concluded that the compensation method can reduce the inertial and gravitational artifacts to an acceptable level for human gait analysis.


Asunto(s)
Articulación del Tobillo/fisiología , Marcha/fisiología , Gravitación , Articulación de la Cadera/fisiología , Articulación de la Rodilla/fisiología , Modelos Lineales , Acelerometría , Artefactos , Fenómenos Biomecánicos , Prueba de Esfuerzo , Humanos , Fenómenos Mecánicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA