Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Acta Radiol ; 65(7): 724-734, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38630492

RESUMEN

BACKGROUND: Dynamic myocardial computed tomography perfusion (CTP) is a novel imaging technique that increases the applicability of CT for cardiac imaging; however, the scanning requires a substantial radiation dose. PURPOSE: To investigate the feasibility of dose reduction in dynamic CTP by comparing all-heartbeat acquisitions to periodic skipping of heartbeats. MATERIAL AND METHODS: We retrieved imaging data of 38 dynamic CTP patients and created new datasets with every fourth, third or second beat (Skip1:4, Skip1:3, Skip1:2, respectively) removed. Seven observers evaluated the resulting images and perfusion maps for perfusion deficits. The mean blood flow (MBF) in each of the 16 myocardial segments was compared per skipped-beat level, normalized by the respective MBF for the full dose, and averaged across patients. The number of segments/cases whose MBF was <1.0 mL/g/min were counted. RESULTS: Out of 608 segments in 38 cases, the total additional number of false-negative (FN) segments over those present in the full-dose acquisitions and the number of additional false-positive cases were shown as acquisition (segment [%], case): Skip1:4: 7 (1.2%, 1); Skip1:3: 12 (2%, 3), and Skip1:2: 5 (0.8%, 2). The variability in quantitative MBF analysis in the repeated analysis for the reference condition resulted in 8 (1.3%) additional FN segments. The normalized results show a comparable MBF across all segments and patients, with relative mean MBFs as 1.02 ± 0.16, 1.03 ± 0.25, and 1.06 ± 0.30 for the Skip1:4, Skip1:3, and Skip1:2 protocols, respectively. CONCLUSION: Skipping every second beat acquisition during dynamic myocardial CTP appears feasible and may result in a radiation dose reduction of 50%. Diagnostic performance does not decrease after removing 50% of time points in dynamic sequence.


Asunto(s)
Imagen de Perfusión Miocárdica , Dosis de Radiación , Humanos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Anciano , Estudios de Factibilidad , Tomografía Computarizada por Rayos X/métodos , Adulto , Frecuencia Cardíaca/fisiología , Anciano de 80 o más Años
2.
Int J Cardiol ; 395: 131568, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37913963

RESUMEN

BACKGROUND: The left ventricular strain-volume loop (SVL) combines changes in global longitudinal strain (GLS) and LV volume across a cardiac cycle, providing insight into cardiac dynamics. This study explored the association between left ventricular SVL and presence of fibrosis, assessed with late gadolinium enhancement, in patients with Duchenne muscular dystrophy (DMD). METHODS AND RESULTS: 34 pediatric patients with DMD were included. Feature tracking analysis was used to assess endocardial GLS and volumetric measurements to construct the SVL. Mean age at the time of assessment was 14 ± 3 and 11 ± 2 years old (p < 0.01) in the group with (n = 18) versus without fibrosis (n = 16), respectively. Left ventricular ejection fraction was not significantly different between groups (fibrosis: 56.4 ± 3.8% versus without fibrosis: 54.0 ± 6.3%, p = 0.18). After adjusting for age, the late diastolic slope of the SVL was significantly associated with presence of fibrosis (OR 0.39 [95% CI 0.18-0.85]; area under the receiver operating characteristic curve: 0.83 [95% CI 0.70-0.97]) No significant association was observed for peak strain and fibrosis (OR 1.15 [95% CI 0.86-1.546]). CONCLUSION: A lower late diastolic slope of the left ventricular SVL, related to the interplay between longitudinal deformation and volume changes late in diastole, is associated with presence of myocardial fibrosis in pediatric patients with DMD.


Asunto(s)
Cardiomiopatías , Distrofia Muscular de Duchenne , Disfunción Ventricular Izquierda , Humanos , Niño , Adolescente , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/complicaciones , Medios de Contraste , Distrofia Muscular de Duchenne/complicaciones , Distrofia Muscular de Duchenne/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Gadolinio , Función Ventricular Izquierda , Volumen Sistólico , Fibrosis
3.
BMJ Open Sport Exerc Med ; 10(2): e002070, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38882206

RESUMEN

Exercise can produce transient elevations of cardiac troponin (cTn) concentrations, which may resemble the cTn release profile of myocardial infarction. Consequently, clinical interpretation of postexercise cTn elevations (ie, values above the 99th percentile upper reference limit) remains challenging and may cause clinical confusion. Therefore, insight into the physiological versus pathological nature of postexercise cTn concentrations is warranted. We aim to (1) establish resting and postexercise reference values for recreational athletes engaged in walking, cycling or running exercise; (2) compare the prevalence of (sub)clinical coronary artery disease in athletes with high versus low postexercise cTn concentrations and (3) determine the association between postexercise cTn concentrations and the incidence of major adverse cardiovascular events (MACE) and mortality during long-term follow-up. For this purpose, the prospective TRoponin concentrations following Exercise and the Association with cardiovascular ouTcomes (TREAT) observational cohort study was designed to recruit 1500 recreational athletes aged ≥40 to <70 years who will participate in Dutch walking, cycling and running events. Baseline and postexercise high-sensitivity cTnT and cTnI concentrations will be determined. The prevalence and magnitude of coronary atherosclerosis on computed tomography (eg, coronary artery calcium score, plaque type, stenosis degree and CT-derived fractional flow reserve) will be compared between n=100 athletes with high postexercise cTn concentrations vs n=50 age-matched, sex-matched and sport type-matched athletes with low postexercise cTn concentrations. The incidence of MACE and mortality will be assessed in the entire cohort up to 20 years follow-up. The TREAT study will advance our understanding of the clinical significance of exercise-induced cTn elevations in middle-aged and older recreational athletes. Trial registration number NCT06295081.

4.
Heart Rhythm O2 ; 4(12): 777-783, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38204465

RESUMEN

Background: Invasive measurements of left ventricular (LV) hemodynamic performance can evaluate acute response to cardiac resynchronization therapy (CRT). Objective: The study sought to determine which metric, maximum rate of LV pressure rise (LV dP/dtmax) or LV stroke work (LVSW), is more strongly associated with long-term prognosis. Methods: CRT patients were prospectively included from 3 academic centers. Invasive pressure-volume loop measurements during implantation were performed, and LV dP/dtmax and LVSW were determined at baseline and during biventricular pacing (BVP) as well as their relative increase (%Δ). Hazard ratios (HRs) for the primary outcome of 8-year all-cause mortality were derived using Cox proportional hazards. The secondary endpoint was echocardiographic response, defined as 6-month LV end-systolic volume reduction ≥15%. Results: Paired data from 82 patients were analyzed (67% male; age 66 ± 9 years; QRS duration 158 ± 22 ms, median survival time 72 months). Survival was better when LVSW during BVP was ≥4400 mL∙mm Hg (HR 0.21, 95% CI 0.08-0.58, P < .003) or when ΔLVSW% was ≥10% (HR 0.22, 95% CI 0.08-0.65, P = .006). In multivariate analysis, following direct comparison of continuous measures of acute ΔLV dP/dtmax% and ΔLVSW%, only ΔLVSW% remained associated with the primary endpoint (HR 0.982 per percentage point, P = .028). In contrast to LV dP/dtmax (all P > .05), significant associations with echocardiographic response were found for stroke work during BVP (area under the receiver-operating characteristic curve 0.745, P = .001) and ΔLVSW% (area under the receiver-operating characteristic curve 0.803, P < .001). Conclusion: Stroke work, but not LV dP/dtmax, is consistently associated with long-term prognosis and response after CRT. Our results therefore favor the use of stroke work as the hemodynamic parameter to predict long-term outcome after CRT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA