Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Vascular ; 31(6): 1051-1060, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35578179

RESUMEN

BACKGROUND: A considerable number of patients with abdominal aortic aneurysms (AAA) is not eligible for standard endovascular repair. These complex cases require alternative surgical approaches including the readily available chimney graft endovascular aneurysm repair (Ch-EVAR) or sealing (Ch-EVAS). The optimal configuration for Ch-EVAR or Ch-EVAS is important for success but not yet known. OBJECTIVE: The aim of the present study was to analyze current data of the outcomes of in-vitro chimney graft treatment in complex AAA. METHODS: A systematic review following PRISMA guidelines was conducted including studies reporting on gutter size, main graft compression, and chimney graft compression in in-vitro configurations. RESULTS: The search resulted in 285 articles. 11 studies considering 219 individual tests could be included. Gutter size was comparable between Ch-EVAR and Ch-EVAS configurations. In Ch-EVAR set-ups, the deployed BECG were Advanta V12, VIABAHN®, and BeGraft. One type of SECG was used: VIABAHN®. The four types of main grafts (MG) deployed were: Endurant™ I/II; EXCLUDER Conformable AAA Endoprosthesis and AAA Endoprosthesis, and AFX™ Endovascular AAA Delivery System. In the EVAS-configurations, the Nellix® EVAS system was deployed. In general, SECG presented smaller gutters with higher chimney graft compression. 30% main grafts oversizing seems to give the smallest gutters without high risk of infolding of MG. Oversizing, EndoAnchors, and secondary endobag filling (in Ch-EVAS) reduced gutter sizes. CG ballooning during the entire polymer injection in Ch-EVAS prevented CG compression. CONCLUSION: In-vitro investigations provide insight in optimal Ch-EVAR and Ch-EVAS configurations for simulated complex AAA repair. The findings above might aid physicians in their planning to potential CG set-ups and can be used in future research to refine the most optimal configuration for chimney graft technique in complex AAA.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Procedimientos Endovasculares/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Aprendizaje
2.
J Vasc Surg ; 76(5): 1261-1269, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35709862

RESUMEN

OBJECTIVE: Proximal endograft failure (type Ia endoleak or migration) after endovascular aneurysm repair (EVAR) is associated with hostile aneurysm neck morphology. Neck scoring systems were developed to predict proximal endograft failure but were studied in retrospective studies, which, due to selection bias, may have led to an overestimation of bad outcomes after EVAR. To predict patients who benefit from open repair, preoperative neck morphology and occurrence of long-term proximal endograft failure were investigated in patients enrolled in the endovascular arm of the Dutch Randomized Endovascular Aneurysm Management (DREAM) trial who were suitable for open repair by definition and have long-term follow-up. METHODS: A post-hoc on-treatment analysis of patients after EVAR was performed in 171 patients. Aneurysm neck morphology was quantified using the aneurysm severity grading (ASG) neck score calculated on preoperative computed tomography angiography images. The ASG neck score was used to predict proximal endograft failure. Receiver operating characteristic analysis was performed to calculate a threshold to divide favorable and unfavorable aneurysm necks (low and high risk); positive and negative likelihood-ratios were calculated accordingly. Freedom from proximal endograft failure was compared between groups using Kaplan-Meier analysis. RESULTS: During a median follow-up of 7.6 years, 20 patients suffered proximal endograft failure. Receiver operating characteristic analysis showed an area under the curve of 0.77 (95% confidence interval [CI], 0.65-0.90; P < .001), indicating acceptable prediction. The threshold was determined at ASG neck score ≥5; 30 patients had unfavorable neck morphology, of whom 11 developed proximal endograft failure. The positive likelihood-ratio was 4.4 (95% CI, 2.5-7.8), and the negative likelihood-ratio was 0.51 (95% CI, 0.3-0.8). Twelve years postoperatively, freedom from proximal endograft failure was 91.7% in the favorable group and 53.2% in the unfavorable group, a difference of 38.5% (95% CI, 13.9-63.1; P < .001). CONCLUSIONS: In this study, the ASG neck score predicted proximal endograft failure during the entire follow-up. This exhibits the persistent risk for proximal endograft failure long after EVAR and calls for ongoing surveillance especially in patients with unfavorable aneurysm necks.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Migración de Cuerpo Extraño , Humanos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/etiología , Implantación de Prótesis Vascular/efectos adversos , Prótesis Vascular , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Migración de Cuerpo Extraño/etiología , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo
3.
J Vasc Surg ; 74(3): 1024-1032, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33940072

RESUMEN

OBJECTIVE: The long-term success of endovascular aneurysm repair (EVAR) is limited by complications, most importantly endoleaks. In case of (persistent) type I endoleak (T1EL), secondary intervention is indicated to prevent secondary aneurysm rupture. Different treatment options are suggested for T1ELs, such as endo anchors, (fenestrated) cuffs, embolization, or open conversion. Currently, the treatment of T1EL with liquid embolic agents is available; however, results are not yet addressed. This review presents the safety and efficacy of embolization with liquid embolic agents for treatment of T1ELs after EVAR. METHODS: A systematic literature search was performed for all studies reporting the use of liquid embolic agents as monotherapy for treatment of T1ELs after EVAR. Patient numbers, technical success (successful delivery of liquid embolics in the T1EL) and clinical success (absence of aneurysm related death, endoleak recurrence or additional interventions during follow-up) were examined. RESULTS: Of 1604 articles, 10 studies met the selection criteria, including 194 patients treated with liquid embolics; 73.2% of the patients were male with a median age of 71 years. The overall technical success was 97.9%. Clinical success was 87.6%. Because the median follow-up was only 13.0 months (range, 1-89 months), data on long-term success are almost absent. Four cases (2.1%) of secondary aneurysm rupture after embolization owing to endoleak recurrence were reported. All ruptures occurred in aneurysms exceeding initial treatment diameter of 70 mm. CONCLUSIONS: Initial technical success after liquid embolization for T1EL is high, although long-term clinical success rates are lacking. Within this review, the risk of secondary rupture is comparable with untreated T1EL at 2% with a median follow-up of 13 months, regardless of the initial success of embolization. In general, no decrease in secondary aneurysm rupture after embolization of T1EL after EVAR is demonstrated, although the results of late embolization are debated.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Embolización Terapéutica , Endofuga/terapia , Procedimientos Endovasculares/efectos adversos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/mortalidad , Dimetilsulfóxido/administración & dosificación , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Enbucrilato/administración & dosificación , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/mortalidad , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Polivinilos/administración & dosificación , Medición de Riesgo , Factores de Riesgo , Trombina/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
4.
J Endovasc Ther ; 28(1): 78-92, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32964768

RESUMEN

PURPOSE: To determine if image fusion will reduce contrast volume, radiation dose, and fluoroscopy and procedure times in standard and complex (fenestrated/branched) endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: A search of the PubMed, Embase, and Cochrane databases was performed in December 2019 to identify articles describing results of standard and complex EVAR procedures using image fusion compared with a control group. Study selection, data extraction, and assessment of the methodological quality of the included publications were performed by 2 reviewers working independently. Primary outcomes of the pooled analysis were contrast volume, fluoroscopy time, radiation dose, and procedure time. Eleven articles were identified comprising 1547 patients. Data on 140 patients satisfying the study inclusion criteria were added from the authors' center. Mean differences (MDs) are presented with the 95% confidence interval (CI). RESULTS: For standard EVAR, contrast volume and procedure time showed a significant reduction with an MD of -29 mL (95% CI -40.5 to -18.5, p<0.001) and -11 minutes (95% CI -21.0 to -1.8, p<0.01), respectively. For complex EVAR, significant reductions in favor of image fusion were found for contrast volume (MD -79 mL, 95% CI -105.7 to -52.4, p<0.001), fluoroscopy time (MD -14 minutes, 95% CI -24.2 to -3.5, p<0.001), and procedure time (MD -52 minutes, 95% CI -75.7 to -27.9, p<0.001). CONCLUSION: The results of this meta-analysis confirm that image fusion significantly reduces contrast volume, fluoroscopy time, and procedure time in complex EVAR but only contrast volume and procedure time for standard EVAR. Though a reduction was suggested, the radiation dose was not significantly affected by the use of fusion imaging in either standard or complex EVAR.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Dosis de Radiación , Radiografía Intervencional/efectos adversos , Estándares de Referencia , Estudios Retrospectivos , Resultado del Tratamiento
5.
J Endovasc Ther ; 27(3): 452-461, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32314658

RESUMEN

Purpose: To assess in silicone juxtarenal aneurysm models the gutter characteristics and compression of different types of chimney graft (CG) configurations. Materials and Methods: Fifty-seven combinations of Excluder C3 or Conformable Excluder stent-grafts (23, 26, and 28.5 mm) were deployed in 2 silicone juxtarenal aneurysm models with 3 types of CGs: Viabahn self-expanding (VSE; 6 and 13 mm) or Viabahn balloon-expandable (VBX; 6, 10, and 12 mm) stent-grafts and Advanta V12 balloon-expandable stent-grafts (ABX; 6 and 12 mm). Setups were divided into 4 groups on the basis of increasing CG and main graft (MG) diameters. Two independent observers assessed gutter size and type as well as CG compression on computed tomography scans using postprocessing software. Results: In the smaller diameter combinations (6-mm CG and 23-, 26-, and 28.5-mm MGs), both VSE (p=0.006 to 0.050) and ABX (p=0.045 to 0.050) showed lower gutter areas and volumes compared with VBX. In turn, the VBX showed a nonsignificant tendency to decreased compression, especially compared to ABX. Use of the Excluder C3 showed a 6-fold increase in type A1 gutters (related to type Ia endoleak) as compared to the Conformable Excluder (p=0.018). Balloon-expandable stent-grafts (both ABX and VBX) showed a 3-fold increase in type A1 gutters in comparison with self-expanding stent-grafts (p=0.008). Conclusion: The current study suggests that use of the Conformable Excluder in combination with VSE chimney grafts is superior to the other tested CG/MG combinations in terms of gutter size, gutter type, and CG compression.


Asunto(s)
Angioplastia de Balón/instrumentación , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Stents , Angioplastia de Balón/efectos adversos , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Humanos , Ensayo de Materiales , Modelos Anatómicos , Diseño de Prótesis , Interpretación de Imagen Radiográfica Asistida por Computador
6.
J Endovasc Ther ; 26(1): 62-71, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30572773

RESUMEN

PURPOSE: To investigate in an in vitro model if secondary endobag filling can reduce gutter size during chimney endovascular aneurysm sealing (chEVAS). MATERIALS AND METHODS: Nellix EVAS systems were deployed in 2 silicone juxtarenal aneurysm models with suprarenal aortic diameters of 19 and 24 mm. Four configurations were tested: EVAS with 6-mm balloon-expandable (BE) or self-expanding (SE) chimney grafts (CGs) in the renal branches of both models. Balloons were inflated simultaneously in the CGs and main endografts during primary and secondary endobag filling and polymer curing. Computed tomography (CT) was performed immediately after the primary and secondary fills. Cross-sectional lumen areas were measured on the CT images to calculate gutter volumes and percent change. CG compression was calculated as the reduction in lumen surface area measured perpendicular to the central lumen line. The largest gutter volume and highest compression were presented per CG configuration per model. RESULTS: Secondary endobag filling reduced the largest gutter volumes from 99.4 to 73.1 mm3 (13.2% change) and 84.2 to 72.0 mm3 (27.6% change) in the BECG configurations and from 67.2 to 44.0 mm3 (34.5% change) and 92.7 to 82.3 mm3 (11.2% change) in the SECG configurations in the 19- and 24-mm models, respectively. Secondary endobag filling increased CG compression in 6 of 8 configurations. BECG compression changed by -0.2% and 5.4% and by -1.0% and 0.4% in the 19- and 24-mm models, respectively. SECG compression changed by 10.2% and 16.0% and by 7.2% and 7.3% in the 19- and 24-mm models, respectively. CONCLUSION: Secondary endobag filling reduced paragraft gutters; however, this technique did not obliterate them. Increased CG compression and prolonged renal ischemia time should be considered if secondary endobag filling is used.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis
7.
Eur J Vasc Endovasc Surg ; 57(2): 229-237, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30318394

RESUMEN

OBJECTIVES: Diagnosing colonic ischaemia (CI) after ruptured abdominal aortic aneurysm (RAAA) repair is challenging. This study determined the diagnostic value of sigmoidoscopy in patients suspected of CI after RAAA repair. METHODS: This was a retrospective multicentre cohort study. Patients who underwent RAAA repair in three hospitals in Amsterdam, the Netherlands, between 2004 and 2011 (AJAX cohort) were included. Sigmoidoscopies were carried out based on clinical judgment. Endoscopy results were classified as "no ischaemia," "mild CI," or "moderate to severe CI." The surgical diagnosis was classified as "transmural" or "no transmural" CI. The value of sigmoidoscopy was assessed with calculation of positive and negative predictive values (PPV, NPV) with 95% CI for transmural CI. Logistic regression analysis was used to express the association of risk factors with CI as adjusted OR. RESULTS: Transmural CI was diagnosed in 23 of 351 patients (6.6%). Thirteen of sixteen patients (81%) who underwent direct laparotomy for high suspicion of CI indeed had transmural CI. Forty-six patients (13%) underwent sigmoidoscopy. The prevalence of transmural CI was 22% (10/46; 95% CI 12-36%) in these patients. The PPV for transmural CI of "moderate to severe CI" on sigmoidoscopy was 73% (8/11; 95% CI 43-90%). The PPV of "mild CI" on sigmoidoscopy was 11% (2/19; 95% CI 2.9-31%). The NPV of "no ischaemia" on sigmoidoscopy was 100% (95% CI 78-100%). Cardiac comorbidity (OR 3.1, 95% CI 1.19-7.97), low first haemoglobin (OR 0.6, 95% CI 0.47-0.87), and high vasopressor administration (OR 9.4, 95% CI 1.99-44.46) were independently associated with CI. CONCLUSIONS: Sigmoidoscopy increases the likelihood of correctly identifying the presence or absence of transmural CI, especially in patients with a moderate clinical suspicion for CI after RAAA repair.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Colitis Isquémica/diagnóstico , Sigmoidoscopía , Procedimientos Quirúrgicos Vasculares/efectos adversos , Anciano , Anciano de 80 o más Años , Colitis Isquémica/etiología , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico , Estudios Retrospectivos , Factores de Riesgo
8.
Eur J Vasc Endovasc Surg ; 58(6): 891-901, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31791617

RESUMEN

OBJECTIVES: Juxtarenal aortic surgery induces renal ischaemia reperfusion, which contributes to systemic inflammatory tissue injury and remote organ damage. Renal cooling during suprarenal cross clamping has been shown to reduce renal damage. It is hypothesised that renal cooling during suprarenal cross clamping also has systemic effects and could decrease damage to other organs, like the sigmoid colon. METHODS: Open juxtarenal aortic aneurysm repair was simulated in 28 male Wistar rats with suprarenal cross clamping for 45 min, followed by 20 min of infrarenal aortic clamping. Four groups were created: sham, no, warm (37 °C saline), and cold (4 °C saline) renal perfusion during suprarenal cross clamping. Primary outcomes were renal damage and sigmoid damage. To assess renal damage, procedure completion serum creatinine rises were measured. Peri-operative microcirculatory flow ratios were determined in the sigmoid using laser Doppler flux. Semi-quantitative immunofluorescence microscopy was used to measure alterations in systemic inflammation parameters, including reactive oxygen species (ROS) production in circulating leukocytes and leukocyte infiltration in the sigmoid. Sigmoid damage was assessed using digestive enzyme (intestinal fatty acid binding protein - I-FABP) leakage, a marker of intestinal integrity. RESULTS: Suprarenal cross clamping caused deterioration of all systemic parameters. Only cold renal perfusion protected against serum creatinine rise: 0.45 mg/dL without renal perfusion, 0.33 mg/dL, and 0.14 mg/dL (p = .009) with warm and cold perfusion, respectively. Microcirculation in the sigmoid was attenuated with warm (p = .002) and cold renal perfusion (p = .002). A smaller increase of ROS production (p = .034) was seen only after cold perfusion, while leukocyte infiltration in the sigmoid colon decreased after warm (p = .006) and cold perfusion (p = .018). Finally, digestive enzyme leakage increased more without (1.5AU) than with warm (1.3AU; p = .007) and cold renal perfusion (1.2AU; p = .002). CONCLUSIONS: Renal ischaemia/reperfusion injury after suprarenal cross clamping decreased microcirculatory flow, increased systemic ROS production, leukocyte infiltration, and I-FABP leakage in the sigmoid colon. Cold renal perfusion was superior to warm perfusion and reduced renal damage and had beneficial systemic effects, reducing sigmoid damage in this experimental study.


Asunto(s)
Lesión Renal Aguda/prevención & control , Aneurisma de la Aorta Abdominal/cirugía , Colon Sigmoide/irrigación sanguínea , Perfusión/métodos , Daño por Reperfusión/prevención & control , Lesión Renal Aguda/etiología , Lesión Renal Aguda/patología , Animales , Aorta Abdominal/cirugía , Frío , Colon Sigmoide/patología , Constricción , Modelos Animales de Enfermedad , Calor/efectos adversos , Humanos , Riñón/irrigación sanguínea , Riñón/patología , Masculino , Estrés Oxidativo , Ratas , Daño por Reperfusión/etiología , Daño por Reperfusión/patología , Resultado del Tratamiento
9.
Eur J Vasc Endovasc Surg ; 56(5): 663-671, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30115505

RESUMEN

OBJECTIVES: Perivascular adipose tissue (PVAT) is currently seen as a paracrine organ that produces vasoactive substances, including inflammatory agents, which may have an impact on the vasculature. In this study PVAT density was quantified in patients with an aortic aneurysm and compared with those with a non-dilated aorta. Since chronic inflammation, as the pathway to medial thinning, is a hallmark of abdominal aortic aneurysms (AAAs), it was hypothesised that PVAT density is higher in AAA patients. METHODS: In this multicentre retrospective case control study, three groups of patients were included: non-treated asymptomatic AAA (n = 140), aortoiliac occlusive disease (AIOD) (n = 104), and individuals without aortic pathology (n = 97). A Hounsfield units based analysis was performed by computed tomography (CT). As a proxy for PVAT, the density of adipose tissue 10 mm circumferential to the infrarenal aorta was analysed in each consecutive CT slice. Intra-individual PVAT differences were reported as the difference in PVAT density between the region of the maximum AAA diameter (or the mid-aortic region in patients with AIOD or controls) and the two uppermost slices of infrarenal non-dilated aorta just below the renal arteries. Furthermore, subcutaneous (SAT) and visceral (VAT) adipose tissue measurements were performed. Linear models were fitted to assess the association between the study groups, different adipose tissue compartments, and between adipose tissue compartments and aortic dimensions. RESULTS: AAA patients presented higher intra-individual PVAT differences, with higher PVAT density around the aneurysm sac than the healthy neck. This association persisted after adjustment for cardiovascular risk factors and diseases and other fat compartments (ß = 13.175, SE 4.732, p = .006). Furthermore, intra-individual PVAT differences presented the highest correlation with aortic volume that persisted after adjustment for other fat compartments, body mass index, sex, and age (ß = 0.566, 0.200, p = .005). CONCLUSION: The results suggest a relation between the deposition of PVAT and AAA pathophysiology. Further research should explore the exact underlying processes.


Asunto(s)
Tejido Adiposo/cirugía , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta/cirugía , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Vasc Surg ; 66(5): 1379-1389, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29061270

RESUMEN

OBJECTIVE: Randomized trials have shown an initial survival benefit of endovascular over conventional open abdominal aortic aneurysm repair but no long-term difference up to 6 years after repair. Longer follow-up may be required to demonstrate the cumulative negative impact on survival of higher reintervention rates associated with endovascular repair. METHODS: We updated the results of the Dutch Randomized Endovascular Aneurysm Management (DREAM) trial, a multicenter, randomized controlled trial comparing open with endovascular aneurysm repair, up to 15 years of follow-up. Survival and reinterventions were analyzed on an intention-to-treat basis. Causes of death and secondary interventions were compared by use of an events per person-year analysis. RESULTS: There were 178 patients randomized to open and 173 to endovascular repair. Twelve years after randomization, the cumulative overall survival rates were 42.2% for open and 38.5% for endovascular repair, for a difference of 3.7 percentage points (95% confidence interval, -6.7 to 14.1; P = .48). The cumulative rates of freedom from reintervention were 78.9% for open repair and 62.2% for endovascular repair, for a difference of 16.7 percentage points (95% confidence interval, 5.8-27.6; P = .01). No differences were observed in causes of death. Cardiovascular and malignant disease account for the majority of deaths after prolonged follow-up. CONCLUSIONS: During 12 years of follow-up, there was no survival difference between patients who underwent open or endovascular abdominal aortic aneurysm repair, despite a continuously increasing number of reinterventions in the endovascular repair group. Endograft durability and the need for continued endograft surveillance remain key issues.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Complicaciones Posoperatorias/terapia , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Bélgica , Implantación de Prótesis Vascular/mortalidad , Causas de Muerte , Supervivencia sin Enfermedad , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Países Bajos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/mortalidad , Retratamiento , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
J Am Heart Assoc ; 9(20): e016695, 2020 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-33012240

RESUMEN

Background Endovascular repair has become a viable alternative for aortic pathological features, including those located within the aortic arch. We investigated the anatomic suitability for branched thoracic endovascular repair in patients previously treated with conventional open surgery for aortic arch pathological features. Methods and Results Patients who underwent open surgery for aortic arch pathological features at our institution between 2000 and 2018 were included. Anatomic suitability was determined by strict compliance with the anatomic criteria within manufacturers' instructions for use for each of the following branched thoracic stent grafts: Relay Plus Double-Branched (Terumo-Aortic), TAG Thoracic Branch Endoprosthesis (W.L. Gore & Associates), Zenith Arch Branched Device (Cook-Medical), and Nexus Stent Graft System (Endospan Ltd/Jotec GmbH). Computed tomography angiography images were analyzed with outer luminal line measurements. A total of 377 patients (mean age, 64±14 years; 64% men) were identified, 153 of whom had suitable computed tomography angiography images for measurements. In total, 59 patients (15.6% of the total cohort and 38.6% of the measured cohort) were eligible for endovascular repair using at least one of the devices. Device suitability was 30.9% for thoracic aneurysms, 4.6% for type A dissections, 62.5% for type B dissections, and 28.6% for other pathological features. Conclusions The anatomic suitability for endovascular repair of all aortic arch pathological features was modest. The highest suitability rates were observed for thoracic aneurysms and for type B dissections, of which repair included part of the aortic arch. We suggest endovascular repair of arch pathological features should be reserved for high-volume centers with experience in endovascular arch repair.


Asunto(s)
Aorta Torácica , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Procedimientos Endovasculares , Complicaciones Posoperatorias , Stents , Injerto Vascular , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/epidemiología , Disección Aórtica/patología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/patología , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/epidemiología , Aneurisma de la Aorta Torácica/patología , Prótesis Vascular/tendencias , Angiografía por Tomografía Computarizada/métodos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Evaluación de Procesos y Resultados en Atención de Salud , Selección de Paciente , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Stents/efectos adversos , Stents/clasificación , Stents/tendencias , Injerto Vascular/efectos adversos , Injerto Vascular/instrumentación , Injerto Vascular/métodos
12.
EJVES Short Rep ; 42: 15-17, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30734004

RESUMEN

INTRODUCTION: Ruptured abdominal aortic aneurysms (AAAs) are known to be associated with high fatal outcomes. Giant AAAs are often defined as having a maximum diameter over 13 cm. Large AAAs over 8 cm have demonstrated a yearly rupture rate of 30-50%, which explains the rarity of giant AAAs. Endovascular repair of ruptured AAAs (rAAAs) is increasingly advocated because of the shorter hospital stay and fewer post-operative complications. Nonetheless, outcomes regarding mortality and cost-effectiveness show a large variability and long-term outcomes are lacking. Few data have been published on treatment of giant AAAs and rAAAs; however, open surgery is generally the preferred option. REPORT: An 83 year old presented to the Emergency Department with a history of ruptured abdominal aortic aneurysm treated with an aorto-uni-iliac endograft and a femorofemoral crossover bypass. During follow up, this was complicated by a symptomatic type III endoleak, which was treated by endovascular repair. During the current admission, he presented with a re-rupture of his former aneurysm, which now was 18 cm diameter because of a type IA endoleak. Open surgical repair was performed and the post-operative course was without complications. DISCUSSION: The current case underlines the value of vascular surgeons being able to perform both open and endovascular surgery in rAAA.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA