Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Anesthesiol ; 23(1): 238, 2023 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-37452279

RESUMEN

BACKGROUND: Conflicting data exist regarding the effects of deep neuromuscular blockade (NMB) on abdominal dimensions during laparoscopic procedures. We performed a clinical study to establish the influence of moderate and deep neuromuscular blockade (NMB) on the abdominal working space, measured by Magnetic Resonance Imaging (MRI), during laparoscopic donor nephrectomy with standard pressure (12 mmHg) pneumoperitoneum under sevoflurane anaesthesia. METHODS: Ten patients were intraoperatively scanned three times in the lateral decubitus position, with pneumoperitoneum maintained by a mobile insufflator. The first scan without NMB (T1) was followed by scans with moderate (T2) and deep NMB (T3). The skin-sacral promontory (S-SP) distance was measured, and 3D pneumoperitoneum volumes were reconstructed. RESULTS: The mean difference in the S-SP distance was -0.32 cm between T2 and T3 (95% CI -1.06 - 0.42 cm; p = 0.344) and + 2.1 cm between T1 and T2 (95% CI 0.81 - 3.39 cm; p = 0.006). The mean differences in pneumoperitoneum volume were 166 mL between T2 and T3 (95% CI, 5 - 327 mL; p = 0.044) and 108 mL between T1 and T2 (95% CI, -273 - 488 mL; p = 0.525). The pneumoperitoneum volume showed high inter-individual variability and no increase in three patients with a high volume at T1. CONCLUSIONS: During laparoscopic surgery in the lateral decubitus position with standard pressure under sevoflurane anaesthesia, deep NMB did not increase the S-SP distance compared to moderate NMB. Moderate NMB increased the S-SP distance by a mean of 2.1 cm (15.2%) compared with no NMB. The mean pneumoperitoneum volume increased slightly from moderate to deep NMB, with high inter-individual variability. TRIAL REGISTRATION: Clinicaltrials.gov ID: NCT03287388.


Asunto(s)
Laparoscopía , Bloqueo Neuromuscular , Neumoperitoneo , Humanos , Bloqueo Neuromuscular/métodos , Sevoflurano , Laparoscopía/métodos , Abdomen
2.
PLoS One ; 16(1): e0246196, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33497422

RESUMEN

Orthognathic surgery is a widely performed procedure to correct dentofacial deformities. Virtual treatment planning is an important preparation step. One advantage of the use of virtual treatment planning is the possibility to assess the accuracy of orthognathic surgery. In this study, a tool (OrthoGnathicAnalyser 2.0), which allows for quantification of the accuracy of orthognathic surgery, is presented and validated. In the OrthoGnathicAnalyser 2.0 the accuracy of the osseous chin can now be assessed which was not possible in the earlier version of the OrthoGnathicAnalyser. 30 patients who underwent bimaxillary surgery in combination with a genioplasty were selected from three different centers in the Netherlands. A pre-operative (CB)CT scan, virtual treatment planning and postoperative (CB)CT scan were required for assessing the accuracy of bimaxillary surgery. The preoperative and postoperative (CB)CT scans were aligned using voxel-based matching. Furthermore, voxel-based matching was used to align the pre-operative maxilla, mandible and rami towards their postoperative position whereas surface-based matching was used for aligning the pre-operative chin towards the postoperative position. The alignment resulted in a transformation matrix which contained the achieved translations and rotations. The achieved translations and rotations can be compared to planning values of the virtual treatment plan. To study the reproducibility, two independent observers processed all 30 patients to assess the inter-observer variability. One observer processed the patients twice to assess the intra-observer variability. Both the intra- and inter-observer variability showed high ICC values (> 0.92) and low measurement variations (< 0.673±0.684mm and < 0.654±0.824°). The results of this study show that the OrthoGnathicAnalyser 2.0 has an excellent reproducibility for quantification of skeletal movements between two (CB)CT scans.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Mentoplastia , Imagenología Tridimensional , Cirugía Ortognática , Planificación de Atención al Paciente , Adulto , Femenino , Humanos , Masculino
3.
IEEE Int Conf Robot Autom ; 2017: 6156-6161, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-31489254

RESUMEN

Soft miniaturized untethered grippers can be used to manipulate and transport biological material in unstructured and tortuous environments. Previous studies on control of soft miniaturized grippers employed cameras and optical images as a feedback modality. However, the use of cameras might be unsuitable for localizing miniaturized agents that navigate within the human body. In this paper, we demonstrate the wireless magnetic motion control and planning of soft untethered grippers using feedback extracted from B-mode ultrasound images. Results show that our system employing ultrasound images can be used to control the miniaturized grippers with an average tracking error of 0.4±0.13 mm without payload and 0.36±0.05 mm when the agent performs a transportation task with a payload. The proposed ultrasound feedback magnetic control system demonstrates the ability to control miniaturized grippers in situations where visual feedback cannot be provided via cameras.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA