Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 464
Filtrar
Más filtros

Intervalo de año de publicación
1.
Am J Epidemiol ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38775290

RESUMEN

Electronic medical records (EMR) are important for rapidly compiling information to determine disease characteristics (e.g., symptoms) and risk factors (e.g., underlying comorbidities, medications) for disease-related outcomes. To assess EMR data accuracy, agreement between EMR abstractions and patient interviews was evaluated. Symptoms, medical history, and medication usage among COVID-19 patients collected from EMR and patient interviews were compared using overall agreement (same answer in EMR and interview), reported agreement (yes answer in both EMR and interview among those who reported yes in either), and Kappa statistics. Overall, patients reported more symptoms in interviews than in EMR abstractions. Overall agreement was high (≥50% for 20/23 symptoms), but only subjective fever and dyspnea had reported agreement of ≥50%. Kappa statistics for symptoms were generally low. Reported medical conditions had greater agreement with all condition categories (10/10) having ≥50% overall agreement and half (5/10) having ≥50% reported agreement. More non-prescription medications were reported in interviews than in EMR abstractions leading to low reported agreement (28%). Discordance was observed for symptoms, medical history, and medication usage between EMR abstractions and patient interviews. Investigations utilizing EMR to describe clinical characteristics and identify risk factors should consider the potential for incomplete data, particularly for symptoms and medications.

2.
BMC Cancer ; 24(1): 329, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38468209

RESUMEN

BACKGROUND: Population-based cancer quality registries are of great importance for the improvement of cancer care. However, little is known about the quality of recurrence data in cancer quality registries. The aim of this study was to evaluate data quality in the regional Breast Cancer Quality Registry of Central Sweden, with emphasis on the validity of recorded information on recurrence. METHODS: Validation by re-abstraction was performed on a random sample of 800 women with primary invasive breast cancer stage I-III diagnosed between 1993 and 2010, of which 400 had at least one registered recurrence and 400 had no registered recurrence. Registry data were compared with data from medical records. Exact agreement, correlation and kappa values, sensitivity and specificity were calculated. RESULTS: Seven hundred forty-seven women (93%) were available for analysis. Exact agreement was high for diagnostics, tumor characteristics, surgery, and adjuvant oncological treatment (90% or more for most variables). The registry's sensitivity was low for regional recurrence (47%), but higher for local and distant recurrence (80% and 75%), whereas specificity was overall high (≥ 95%). Combining all recurrence categories irrespective of localization improved sensitivity to 90% with a specificity of 91%. In 87% of women, the date of first recurrence according to medical records fell within ± 90 days of the date recorded in the registry. CONCLUSIONS: While the quality of data in the regional Breast Cancer Quality Registry was generally high, data accuracy on recurrences was lower. The overall precision of identifying any recurrence, irrespective of localization, was high. However, the accuracy of classification of recurrences (local, regional or distant) was lower, with evidence of underreporting for each of the recurrence categories. Given the importance of recurrence-related outcomes in the assessment of quality of care, efforts should be made to improve the reporting of recurrences.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/terapia , Exactitud de los Datos , Suecia/epidemiología , Sensibilidad y Especificidad , Sistema de Registros , Recurrencia Local de Neoplasia/epidemiología , Recurrencia Local de Neoplasia/patología
3.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1633-1639, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38214734

RESUMEN

PURPOSE: To compare the results of retinal venous pressure (RVP) measurement performed with contact lens dynamometry (CLD) and with the new IOPstim. METHODS: In this cross-sectional study, we included 36 patients with primary open angle glaucoma with a median age (Q25; Q75) of 74 (64; 77) years (m/f = 18/18), baseline intraocular pressure (IOP): 13.9 (12.2; 15.1) mmHg. Median mean defect: - 5.8 (- 11.9; - 2.6) db. Principle of the IOPstim: an empty balloon with a diameter of 8 mm is positioned on the eye, laterally of the limbus. Under observation of the central retinal vein (CRV), the examiner inflates the balloon. As soon as the CRV starts pulsation, the inflation is stopped and the IOP is measured, equaling the RVP at this moment. In the CLD, the pulsation of the CRV is observed with a contact lens. The RVP is calculated from the attachment force applied when pulsation appears. COURSE OF EXAMINATIONS: Three single measurements of RVP in quick succession with both methods. The sequence of the two methods was randomized. The means of the three RVP measurements were compared. RESULTS: Pressures in mmHg. RVP: IOPstim: 19.4 ± 5.4 (mean ± SD), CLD: 20.3 ± 5.9. Range of three single measurements: IOPstim: 2.9 ± 1.5, CLD: 2.2 ± 1.1. The differences were RVPIOPstim - RVPCLD = - 0.94 ± 1.15, and approximately normally distributed. Bland-Altman analysis: only one data point was 0.5 mmHg higher than the upper line of agreement. The confidence interval of this line was 0.65 mmHg. Concordance correlation coefficient according to Lin (CCC): 0.96. Intraclass correlation coefficient: both methods, 0.94. CONCLUSION: In both methods, the range of the single measurements may be taken as a sign of good reliability, the CCC of 0.96 as a sign of a very good agreement. At the mean, the IOPstim RVP values were 1 mmHg lower than those obtained with the CLD. This difference may be due to the different directions of the prevailing force vectors induced by the instruments. The IOPstim seems applicable in glaucoma diagnostics.


Asunto(s)
Glaucoma de Ángulo Abierto , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Estudios Transversales , Reproducibilidad de los Resultados , Presión Venosa , Presión Intraocular , Tonometría Ocular
4.
J Public Health (Oxf) ; 46(1): 87-96, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38141038

RESUMEN

BACKGROUND: During the pandemic, countries utilized various forms of statistical estimations of coronavirus disease-2019 (COVID-19) impact. Differences between databases make direct comparisons and interpretations of data in different countries a challenge. We evaluated country-specific approaches to COVID-19 data and recommended changes that would improve future international collaborations. METHODS: We compared the COVID-19 reports presented on official UK (National Health System), Israeli (Department of Health), Latvian (Center for Disease Prevention and Control) and USA (Centers for Disease Control and Prevention) health authorities' websites. RESULTS: Our analysis demonstrated critical differences in the ways COVID-19 statistics were made available to the general and scientific communities. Specifically, the differences in approaches were found in the presentation of the number of infected cases and tests, and percentage of positive cases, the number of severe cases, the number of vaccinated, and the number and percent of deaths. CONCLUSION: Findability, Accessibility, Interoperability and Reusability principles could guide the development of essential global standards that provide a basis for communication within and outside of the scientific community.


Asunto(s)
COVID-19 , Humanos , COVID-19/epidemiología , Comunicación , Atención a la Salud
5.
Scand J Public Health ; : 14034948231219825, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38179995

RESUMEN

AIMS: To determine the quality of prospectively collected data from the highly specialized Danish Cerebral Palsy Follow-up Program (CPOP), and to establish the validity of a reported cerebral palsy (CP) diagnosis in the Danish National Patient Registry (NPR), regularly used as a proxy for neurodevelopmental disorders in epidemiological research. METHODS: We compared data from the two registries on children with registered CP, born in Denmark between 2008 and 2009, with information from medical records verified by two experienced physicians specializing in pediatric neurology. Data accuracy was estimated by completeness, correctness, and reliability. Completeness was calculated as the number of cases with correctly registered CP diagnoses divided by the total number of true CP diagnoses (similar to sensitivity). Correctness was calculated as the number of cases with correct registrations divided by the total number of cases (similar to positive predictive value). Reliability was estimated using kappa statistics. RESULTS: Registered CP diagnoses in the CPOP had high accuracy, with 94% correctness and 91% completeness. Furthermore, most key variables in the CPOP showed excellent reliability, especially variables defining the severity of the condition. In the Danish NPR, only 225 of 348 children with a noted CP diagnosis fulfilled the diagnostic criteria for CP, resulting in 65% correctness. CONCLUSIONS: Danish CPOP data are a valid source for epidemiological research. Conversely, a noted CP diagnosis in the Danish NPR was, at best, correct in only two out of three patients.

6.
BMC Public Health ; 24(1): 2188, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39135026

RESUMEN

BACKGROUND: Population surveys are crucial for public policy planning and provide valuable representative data. In the health sector studies to identify and assess the prevalence of Arterial Hypertension (AH), a chronic non-communicable disease (NCD), along with its associated risk factors have been conducted. OBJECTIVES: This study aims to assess the effectiveness of a population health survey in estimating the prevalence of arterial hypertension (AH) in the Sorocaba municipality between August 2021 and June 2023. METHODS: The analyzed performance indicator is the precision (design effect - deff) of AH prevalence in adults (≥ 18 years) and their exposure to primary risk factors. The total sample included 1,080 individuals from the urban area, deemed sufficient to estimate a deff of 1.5. This cluster-based study utilized census sectors as clusters, with data collected through household interviews, standardized questionnaires, and measurements of blood pressure and biometric parameters. The deff calculation formula used was weighted variance / raw variance. The Research Ethics Committee approved this study, with registration CAAE 30538520-1-0000-5373. RESULTS: The deff values ranged from 0.44 for chronic obstructive pulmonary disease to 1.63 for asthma, with a deff of 1.00 for AH prevalence. CONCLUSION: The study demonstrated good precision in its results, with high receptivity and cooperation from participants. The cost-effectiveness of the research deemed appropriate. The technique of selecting households within clusters (census sectors) based on detailed mapping and demographic data from the Instituto Brasileiro de Geografia e Estatística (IBGE) proved to be practical and efficient, suitable for replication in other municipalities and for studying other NCDs.


Asunto(s)
Encuestas Epidemiológicas , Hipertensión , Humanos , Hipertensión/epidemiología , Hipertensión/diagnóstico , Prevalencia , Adulto , Masculino , Persona de Mediana Edad , Femenino , Anciano , Adolescente , Adulto Joven , Factores de Riesgo , Brasil/epidemiología
7.
BMC Public Health ; 24(1): 361, 2024 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-38310211

RESUMEN

BACKGROUND: The quality of the statistics on causes of death (CoD) does not present consolidated indicators in literature further than the coding group of ill-defined conditions of the International Classification of Diseases. Our objective was to assess the territorial quality of CoD by reliability of the official mortality statistics in Spain over the years 1980-2019. METHODS: A descriptive epidemiological design of four decades (1980-, 1990-, 2000-, and 2010-2019) by region (18) and sex was implemented. The CoD cases, age-adjusted rates and ratios (to all-cause) were assigned by reliability to unspecific and ill-defined quality categories. The regional mortality rates were contrasted to the Spanish median by decade and sex by the Comparative Mortality Ratio (CMR) in a Bayesian perspective. Statistical significance was considered when the CMR did not contain the value 1 in the 95% credible intervals. RESULTS: Unspecific, ill-defined, and all-cause rates by region and sex decreased over 1980-2019, although they scored higher in men than in women. The ratio of ill-defined CoD decreased in both sexes over these decades, but was still prominent in 4 regions. CMR of ill-defined CoD in both sexes exceeded the Spanish median in 3 regions in all decades. In the last decade, women's CMR significantly exceeded in 5 regions for ill-defined and in 6 regions for unspecific CoD, while men's CMR exceeded in 4 and 2 of the 18 regions, respectively on quality categories. CONCLUSIONS: The quality of mortality statistics of causes of death has increased over the 40 years in Spain in both sexes. Quality gaps still remain mostly in Southern regions. Authorities involved might consider to take action and upgrading regional and national death statistics, and developing a systematic medical post-grade training on death certification.


Asunto(s)
Causas de Muerte , Masculino , Humanos , Femenino , España/epidemiología , Reproducibilidad de los Resultados , Teorema de Bayes , Causalidad
8.
Acta Neurochir (Wien) ; 166(1): 189, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38653826

RESUMEN

PURPOSE: Lumbar spinal stenosis (LSS) is a prevalent disorder, and surgery for LSS is a common procedure. Postoperative complications occur after any surgery and impose costs for society and costs and additional morbidity for patients. Since complications are relatively rare, medical registries of large populations may provide valuable knowledge. However, recording of complications in registries can be incomplete. To better estimate the true prevalence of complications after LSS surgery, we reviewed two different sources of data and recorded complications for a sample of Norwegian LSS patients. METHODS: 474 patients treated surgically for LSS during 2015 and 2016 at four hospitals reported to a national spine registry (NORspine). Postoperative complications were recorded by patients in NORspine, and we cross-referenced complications documented in NORspine with the patients´ electronic patient records (EPR) to re-test the complication rates. We performed descriptive statistics of complication rates using the two different data sources above, and analyzed the association between postoperative complications and clinical outcome with logistic regression. RESULTS: The mean (95%CI) patient age was 66.3 (65.3-67.2) years, and 254 (53.6%) were females. All patients were treated with decompression, and 51 (10.7%) received an additional fusion during the index surgery. Combining the two data sources, we found a total rate for postoperative complications of 22.4%, the NORspine registry reported a complication rate of 15.6%, and the EPR review resulted in a complication rate of 16.0%. However, the types of complications were inconsistent across the two data sources. According to NORspine, the frequency of reoperation within 90 days was 0.9% and according to EPR 3.4%. The rates of wound infection were for NORspine 3.1% and EPR review 2.1%. There was no association between postoperative complication and patient reported outcome. CONCLUSION: Postoperative complications occurred in 22% of LSS patients. The frequency of different postoperative complications differed between the two data sources.


Asunto(s)
Descompresión Quirúrgica , Vértebras Lumbares , Complicaciones Posoperatorias , Sistema de Registros , Fusión Vertebral , Estenosis Espinal , Humanos , Estenosis Espinal/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Femenino , Masculino , Anciano , Vértebras Lumbares/cirugía , Descompresión Quirúrgica/efectos adversos , Descompresión Quirúrgica/métodos , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos , Noruega/epidemiología , Persona de Mediana Edad , Fuentes de Información
9.
Sensors (Basel) ; 24(1)2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38203147

RESUMEN

In the fields of industrial production or safety monitoring, wireless sensor networks are often content with unreliable and time-varying channels that are susceptible to interference. Consequently, ensuring both transmission reliability and data accuracy has garnered substantial attention in recent years. Although multipath routing-based schemes can provide transmission reliability for wireless sensor networks, achieving high data accuracy simultaneously remains challenging. To address this issue, an Energy-efficient Multipath Routing algorithm balancing data Accuracy and transmission Reliability (EMRAR) is proposed to balance the reliability and accuracy of data transmission. The multipath routing problem is formulated into a multi-objective programming problem aimed at optimizing both reliability and power consumption while adhering to data accuracy constraints. To obtain the solution of the multi-objective programming, an adaptive artificial immune algorithm is employed, in which the antibody initialization method, antibody incentive calculation method, and immune operation are improved, especially for the multipath routing scheme. Simulation results show that the EMRAR algorithm effectively balances data accuracy and transmission reliability while also saving energy when compared to existing algorithms.

10.
Arch Orthop Trauma Surg ; 144(3): 1149-1159, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38231206

RESUMEN

INTRODUCTION: Despite being the most used exam today, few studies have evaluated the accuracy of findings on non-contrast magnetic resonance imaging (MRI). The primary objective of the study was to evaluate the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of non-contrast MRI findings in frozen shoulder, isolated and in combination. The secondary objectives were to define the interobserver and intraobserver agreement of the assessments and the odds ratio for frozen shoulder because of the various findings of MRI. METHODS: A retrospective diagnostic accuracy study comparing non-contrast MRI findings between the frozen shoulder group and the control group. Sensitivity, specificity, positive and negative predictive value, accuracy, odds ratio, interobserver and intraobserver agreement were calculated for each finding and their possible associations. RESULTS: The hyperintensity on capsule in the axillary recess presented 84% sensitivity, 94% specificity, and 89% accuracy. The obliteration of the subcoracoid fat triangle in the rotator interval had sensitivity 34%, specificity 82% and accuracy 58%. For coracohumeral ligament thickness ≥ 2 mm had specificity 66%, 48% specificity and 57% accuracy. Capsule thickness in the axillary recess ≥ 4 mm resulted in 54% sensitivity, 82% specificity, and 68% accuracy. Regarding interobserver agreement, only the posteroinferior and posterosuperior quadrants showed moderate results, and all the others showed strong reliability. The odds ratio for hyperintensity in the axillary recess was 82.3 for frozen shoulder. The association of these findings increased specificity (95%). CONCLUSION: The accuracy of non-contrast magnetic resonance imaging is high for diagnosing frozen shoulder, especially when evaluating the hyperintensity of the axillary recess. The exam has high reliability and reproducibility. The presence of an association of signs increases the specificity of the test. LEVEL OF EVIDENCE: Level III, study of diagnostic test.


Asunto(s)
Bursitis , Articulación del Hombro , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Articulación del Hombro/patología , Imagen por Resonancia Magnética/métodos , Bursitis/diagnóstico por imagen , Sensibilidad y Especificidad
11.
HNO ; 2024 Apr 09.
Artículo en Alemán | MEDLINE | ID: mdl-38592481

RESUMEN

BACKGROUND: Results of neurotological function diagnostics in the context of interdisciplinary vertigo assessment are usually formulated as free-text reports (FTR). These are often subject to high variability, which may lead to loss of information. The aim of the present study was to evaluate the completeness of structured reports (SR) and referrer satisfaction in the neurotological assessment of vertigo. MATERIALS AND METHODS: Neurotological function diagnostics performed as referrals (n = 88) were evaluated retrospectively. On the basis of the available raw data, SRs corresponding to FTRs from clinical routine were created by means of a specific SR template for neurotological function diagnostics. FTRs and SRs were evaluated for completeness and referring physician satisfaction (n = 8) using a visual analog scale (VAS) questionnaire. RESULTS: Compared to FTRs, SRs showed significantly increased overall completeness (73.7% vs. 51.7%, p < 0.001), especially in terms of patient history (92.5% vs. 66.7%, p < 0.001), description of previous findings (87.5% vs. 38%, p < 0.001), and neurotological (33.5% vs. 26.7%, p < 0.001) and audiometric function diagnostics (58% vs. 32.3%, p < 0.001). In addition, SR showed significantly increased referring physician satisfaction (VAS 8.8 vs. 4.9, p < 0.001). CONCLUSION: Neurotological SRs enable a significantly increased report completeness with higher referrer satisfaction in the context of interdisciplinary assessment of vertigo. Furthermore, SRs are particularly suitable for scientific data analysis, especially in the context of big data analyses.

12.
BMC Oral Health ; 24(1): 736, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38926728

RESUMEN

AIM: The study was performed to compare the mandibular resection guide with a directional guidance slot with the conventional guide regarding three-dimensional positional accuracy. MATERIALS AND METHODS: Twenty-six patients with lateral segmental mandibular defects were selected, and randomly allocated into two groups. All defects were managed with preoperative virtual surgical planning. Resection in the test group was conducted using a resection guide with a directional guidance slot, while a conventional resection guide design was utilized in the control group. The linear and angular deviation of the osteotomy planes was analyzed for both groups, along with the accuracy of the insertion of the reconstruction bone block in the resected defect. Data were documented, absolute deviation was calculated, statistical analysis was performed and significance was set at the 5% level. RESULTS: The cases conducted with a directional guidance templet reported a statistically significant difference when compared to the conventional edge-cutting guide regarding the linear and angular spatial osteotomy plane position (P < 0.001). The defect span analysis reported excellent levels of agreement in both groups (ICC = 1.00, ICC = 0.995), however, the difference between the groups was statistically significant (P < 0.001). CONCLUSION: The study demonstrated the enhanced positional accuracy of the resection plane and reconstruction block placement when a directional slot is incorporated in the computer-generated resection guide.


Asunto(s)
Mandíbula , Cirugía Asistida por Computador , Humanos , Femenino , Masculino , Cirugía Asistida por Computador/métodos , Mandíbula/cirugía , Adulto , Imagenología Tridimensional/métodos , Osteotomía/métodos , Osteotomía/instrumentación , Persona de Mediana Edad
13.
J Prosthodont ; 33(6): 550-557, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38507280

RESUMEN

PURPOSE: The aims of the present study were (a) to compare the scanning time and image count to complete optical scans of a typodont between augmented-reality-assisted intraoral scanning (ARIOS) and intraoral scanning (IOS); (b) to compare the accuracy of the digital casts derived from ARIOS and IOS; (c) to compare participant-related outcomes between ARIOS and IOS. MATERIALS AND METHODS: A multi-session within-subject experiment was conducted to compare ARIOS and IOS. Thirty-one dental students participated in the study. Following a trial session, each participant obtained optical scans under ARIOS and IOS conditions. The time required to complete the scan, and the number of images taken were recorded. Participant feedback was collected using entry, exit, and NASA-Task Load Index (TLX) surveys. The accuracy of the digital casts derived from the optical scans was measured in root mean square error (RMSE). RESULTS: The present study found a 6.8% increase in preference for ARIOS from entry to exit survey. Slightly more participants favored the ARIOS setup compared to IOS; 54.8% of participants favored ARIOS, 9.7% were indifferent, and 35.5% favored IOS. NASA-TLX subscale ratings were higher for IOS in general apart from mental demand. The accuracy of the digital casts between ARIOS and IOS was comparable in RMSE. CONCLUSION: ARIOS was advantageous compared to IOS in ergonomics, improved scanner tracking, and ease of scanner orientation. However additional trials, increased field of view, and better superimposition of scanning status to the target site were improvements desired by the study participants.


Asunto(s)
Realidad Aumentada , Prueba de Estudio Conceptual , Humanos , Femenino , Modelos Dentales , Masculino , Diseño Asistido por Computadora , Imagenología Tridimensional/métodos , Adulto Joven , Estudiantes de Odontología , Adulto
14.
Eur Radiol ; 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37855854

RESUMEN

OBJECTIVES: This study aimed to evaluate the diagnostic accuracy, inter-reader agreement, and associated pathologies on MR images of patients with confirmed TC. METHODS AND MATERIALS: In this retrospective study, 168 ankle MRI exams were included, consisting of 56 patients with clinically or surgically confirmed TC and 112 controls without TC, matched for age and sex. Images were analyzed independently by three radiologists blinded to clinical information. The evaluation criteria included the presence, type, and location of TC, as well as associated pathologies. After calculating diagnostic accuracy and the odds ratio of demographic data and anatomic coalition type for associated pathologies, inter-reader agreement was assessed using kappa statistics. RESULTS: The majority of TCs were non-osseous (91.1%) and located at the calcaneonavicular (33.9%) or talocalcaneal joint (66.1%). Associated pathologies included adjacent and distant bone marrow edema (57.1% and 25.0%), osteochondral defect of the talar dome (OCD, 19.6%), and joint effusion (10.7%) and accessory anterolateral talar facet (17.9%). Talar OCD was associated with increased patient age (p = 0.03). MRI exhibited a cumulative sensitivity and specificity of 95.8% and 94.3% with almost perfect inter-reader agreement (κ = 0.895). CONCLUSION: MRI is a reliable method for detecting tarsal coalition and identifying commonly associated pathologies. Therefore, we recommend the routine use of MRI in the diagnostic workup of patients with foot pain and suspected tarsal coalition. CLINICAL RELEVANCE STATEMENT: MRI is an accurate and reliable modality for diagnosing tarsal coalitions and detecting associated pathologies, while improving patient safety compared to computed tomography by avoiding radiation exposure. KEY POINTS: • Despite the technological progress in magnetic resonance imaging (MRI), computed tomography (CT) is still regarded as the gold standard for diagnosing tarsal coalition (TC). • MRI had a cumulative sensitivity of 95.8% and specificity of 94.3% for detecting tarsal coalition with an almost perfect inter-reader agreement. • MRI demonstrates high accuracy and reliability in diagnosing tarsal coalitions and is useful for identifying associated pathologies, while also improving patient safety by avoiding radiation exposure.

15.
Eur Radiol ; 33(12): 8605-8616, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37439933

RESUMEN

OBJECTIVES: This systematic review and meta-analysis evaluated the diagnostic accuracy of CT and MRI for differentiating atypical lipomatous tumors and malignant liposarcomas from benign lipomatous lesions. METHODS: MEDLINE, EMBASE, Scopus, the Cochrane Library, and the gray literature from inception to January 2022 were systematically evaluated. Original studies with > 5 patients evaluating the accuracy of CT and/or MRI for detecting liposarcomas with a histopathological reference standard were included. Meta-analysis was performed using a bivariate mixed-effects regression model. Risk of bias was evaluated using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). This study is registered on PROSPERO, number CRD42022306479. RESULTS: Twenty-six studies with a total of 2613 patients were included. Mean/median reported patient ages ranged between 50 and 63 years. The summary sensitivity and specificity of radiologist gestalt for detecting liposarcomas was 85% (79-90% 95% CI) and 63% (52-72%), respectively. Deep depth to fascia, thickened septations, enhancing components, and lesion size (≥ 10 cm) all demonstrated sensitivities ≥ 85%. Other imaging characteristics including heterogenous/amorphous signal intensity, irregular tumor margin, and nodules present demonstrated lower sensitivities ranging from 43 to 65%. Inter-reader reliability for radiologist gestalt within studies ranged from fair to substantial (k = 0.23-0.7). Risk of bias was predominantly mixed for patient selection, low for index test and reference standard, and unclear for flow and timing. CONCLUSION: Higher sensitivities for detecting liposarcomas were achieved with radiologist gestalt, deep depth to fascia, thickened septations, enhancing components, and large size. Combined clinical and imaging scoring and/or radiomics both show promise for optimal performance, though require further analysis with prospective study designs. CLINICAL RELEVANCE: This pooled analysis evaluates the accuracy of CT and MRI for detecting atypical lipomatous tumors and malignant liposarcomas. Radiologist gestalt, deep depth to fascia, thickened septations, enhancing components, and large size demonstrate the highest overall sensitivities. KEY POINTS: • The summary sensitivity and specificity of radiologist gestalt for detecting liposarcomas was 85% (79-90% 95% CI) and 63% (52-72%), respectively. • Radiologist gestalt, deep depth to fascia, thickened septations, enhancing components, and large tumor size (≥ 10 cm) showed the highest sensitivities for detecting atypical lipomatous tumors/well-differentiated liposarcomas and malignant liposarcomas. • A combined clinical and imaging scoring system and/or radiomics is likely to provide the best overall diagnostic accuracy, although currently proposed scoring systems and radiomic feature analysis require further study with prospective study designs.


Asunto(s)
Lipoma , Liposarcoma , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Prospectivos , Imagen por Resonancia Magnética , Liposarcoma/diagnóstico por imagen , Liposarcoma/patología , Lipoma/diagnóstico por imagen , Lipoma/patología , Tomografía Computarizada por Rayos X , Sensibilidad y Especificidad
16.
BMC Med Res Methodol ; 23(1): 271, 2023 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-37974111

RESUMEN

Real world evidence is now accepted by authorities charged with assessing the benefits and harms of new therapies. Clinical trials based on real world evidence are much less expensive than randomized clinical trials that do not rely on "real world evidence" such as contained in electronic health records (EHR). Consequently, we can expect an increase in the number of reports of these types of trials, which we identify here as 'EHR-sourced trials.' 'In this selected literature review, we discuss the various designs and the ethical issues they raise. EHR-sourced trials have the potential to improve/increase common data elements and other aspects of the EHR and related systems. Caution is advised, however, in drawing causal inferences about the relationships among EHR variables. Nevertheless, we anticipate that EHR-CTs will play a central role in answering research and regulatory questions.


Asunto(s)
Ensayos Clínicos como Asunto , Registros Electrónicos de Salud , Humanos
17.
Scand J Public Health ; 51(2): 173-178, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34903105

RESUMEN

AIMS: To evaluate the validity of recorded chronic disease diagnoses in Icelandic healthcare registries. METHODS: Eight different chronic diseases from multiple sub-specialties of medicine were validated with respect to accuracy, but not to timeliness. For each disease, 30 patients with a recorded diagnosis and 30 patients without the same diagnosis were randomly selected from >80,000 participants in the iStopMM trial, which includes 54% of the Icelandic population born before 1976. Each case was validated by chart review by physicians using predefined criteria. RESULTS: The overall accuracy of the chronic disease diagnoses was 96% (95% CI 94-97%), ranging from 92 to 98% for individual diseases. After weighting for disease prevalence, the accuracy was estimated to be 98.5%. The overall positive predictive value (PPV) of chronic disease diagnosis was 93% (95% CI 89-96%) and the overall negative predictive value (NPV) was 99% (95% CI 96-100%). There were disease-specific differences in validity, most notably multiple sclerosis, where the PPV was 83%. Other disorders had PPVs between 93 and 97%. The NPV of most disorders was 100%, except for hypertension and heart failure, where it was 97 and 93%, respectively. Those who had the registered chronic disease had objective findings of disease in 96% of cases. CONCLUSIONS: When determining the presence of chronic disease, diagnosis data from the Icelandic healthcare registries has a high PPV, NPV and accuracy. Furthermore, most diagnoses can be confirmed by objective findings such as imaging or blood testing. These findings can inform the interpretation of studies using diagnostic data from the Icelandic healthcare registries.


Asunto(s)
Instituciones de Salud , Clasificación Internacional de Enfermedades , Humanos , Islandia , Valor Predictivo de las Pruebas , Sistema de Registros
18.
J Adv Nurs ; 79(9): 3440-3455, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37106563

RESUMEN

AIM: To understand how nurses talk about documentation audit in relation to their professional role. BACKGROUND: Nursing documentation in health services is often audited as an indicator of nursing care and patient outcomes. There are few studies exploring the nurses' perspectives on this common process. DESIGN: Secondary qualitative thematic analysis. METHODS: Qualitative focus groups (n = 94 nurses) were conducted in nine diverse clinical areas of an Australian metropolitan health service for a service evaluation focussed on comprehensive care planning in 2020. Secondary qualitative analysis of the large data set using reflexive thematic analysis focussed specifically on the nurse experience of audit, as there was the significant emphasis by participants and was outside the scope of the primary study. RESULTS: Nurses': (1) value quality improvement but need to feel involved in the cycle of change, (2) highlight that 'failed audit' does not equal failed care, (3) describe the tension between audited documentation being just bureaucratic and building constructive nursing workflows, (4) value building rapport (with nurses, patients) but this often contrasted with requirements (organizational, legal and audit) and additionally, (5) describe that the focus on completion of documentation for audit creates unintended and undesirable consequences. CONCLUSION: Documentation audit, while well-intended and historically useful, has unintended negative consequences on patients, nurses and workflows. IMPACT: Accreditation systems rely on care being auditable, but when individual legal, organizational and professional standards are implemented via documentation forms and systems, the nursing burden is impacted at the point of care for patients, and risks both incomplete cares for patients and incomplete documentation. NO PATIENT OR PUBLIC CONTRIBUTION: Patients participated in the primary study on comprehensive care assessment by nurses but did not make any comments about documentation audit.


Asunto(s)
Atención de Enfermería , Humanos , Australia , Documentación , Grupos Focales
19.
Rev Panam Salud Publica ; 47: e47, 2023.
Artículo en Portugués | MEDLINE | ID: mdl-37008677

RESUMEN

Objective: To synthesize the evidence about the effects of telehealth interventions provided through smart-phone apps and text messages on the behavior of adults regarding healthy food consumption. Method: A rapid systematic review of the literature was performed through searches in nine electronic databases to identify systematic reviews published in English, Portuguese, and Spanish that evaluated telehealth strategies compared to face-to-face interventions to improve dietary intake in the adult population (18 to 59 years old). Searches were performed in November 2020 and updated in April 2022. The included systematic reviews were assessed for methodological quality using the AMSTAR 2 tool. Results: Five systematic reviews were included. Methodological quality was moderate in one review and critically low in four. There was a dearth of studies comparing the use of telehealth strategies with face-to-face interventions for the promotion of healthy eating in adults. The most consistent results refer to an increase in the consumption of fruits and vegetables with the use of an app or text messages, in addition to improvement in the dietary habits of people with diabetes or glucose intolerance with the use of text messages. Conclusion: Positive effects were observed on healthy eating outcomes for most interventions using mobile apps or text messages; however, the findings refer to a few clinical trials with small samples that were analyzed in the systematic reviews covered in the present rapid review, most of which had low methodological quality. Thus, the current knowledge gap warrants the performance of further methodologically robust studies.


Objetivo: Sintetizar la evidencia sobre los efectos de las intervenciones de telesalud ofrecidas por medio de aplicaciones de telefonía móvil y mensajes de texto en el comportamiento de la población adulta relacionado con una alimentación saludable. Métodos: Se realizó un examen rápido mediante búsquedas en nueve bases bibliográficas electrónicas para localizar revisiones sistemáticas publicadas en español, inglés y portugués en las que se evaluaran estrategias de telesalud en comparación con atención presencial para mejorar la alimentación de la población adulta (de 18 a 59 años). Las búsquedas se realizaron en noviembre del 2020 y se actualizaron en abril del 2022. La calidad metodológica de las revisiones sistemáticas incluidas se evaluó con la herramienta AMSTAR 2. Resultados: Se incluyeron cinco revisiones sistemáticas, una con un grado de confianza moderado y las otras con un grado de confianza sumamente bajo. Se comprobó una falta de estudios en los que se compararan el uso de estrategias de telesalud con la atención presencial para promover la alimentación saludable de la población adulta. Los resultados más coherentes se refieren al aumento del consumo de frutas y verduras con el uso de aplicaciones móviles o de mensajes de texto, así como a la mejora del patrón alimentario de las personas con diabetes o con intolerancia a la glucosa con el uso de mensajes de texto. Conclusión: La mayoría de los análisis de las intervenciones en las que se emplearon aplicaciones de telefonía móvil o mensajes de texto mostraron efectos positivos en los resultados relativos a una alimentación saludable. Sin embargo, estos hallazgos se refieren a unos pocos ensayos clínicos con pequeñas muestras de participantes incluidos en las revisiones sistemáticas del presente examen rápido, en su mayoría de baja calidad metodológica. En conclusión, existe una laguna en los conocimientos y es importante realizar estudios con una metodología más sólida.

20.
J Clin Nurs ; 32(17-18): 6403-6414, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36823714

RESUMEN

AIM: To determine the reporting accuracy of pressure injury categorisation by bedside clinicians, compared with nurse experts. BACKGROUND: Pressure injuries are an enduring complication of hospitalisation. The categorisation of pressure injury affects treatment and management decision-making and use of resources, and severe hospital-acquired pressure injury incidence is used to benchmark quality of care. However, it is unclear how accurately pressure injuries are categorised by clinicians in practice. DESIGN: Secondary analysis of hospital pressure injury incident and validation data. METHODS: All pressure injuries reported in adults between 2016 and 2019 that were subsequently validated by nurse experts were analysed. Absolute agreement is reported using percentages, with inter-rater agreement reported using Kappa measure of agreement. The GRRAS reporting guideline was followed. RESULTS: Of 6186 pressure injuries that were analysed, the category was reported correctly in 67.3% (n = 4163), with an overall moderate level of inter-rater agreement by category (Κ = .567, p < .001). Of those found to be non-pressure injuries when validated (18.3%, n = 1129), most were reported originally as stage II (41.2%, n = 465) or stage I (30.5%, n = 344), and 13.4% (n = 151) were categorised initially as unstageable. The majority reported initially as stage I, stage II, suspected deep tissue injury or mucosal pressure injury were validated, whereas half of those reported initially as stage III or IV were validated and less than a third of those reported initially as unstageable pressure injuries were validated. CONCLUSIONS: This study provides important insight into the accuracy of pressure injury categorisation. Whilst moderate agreement of categorisation was found between reporting clinicians and nurse experts, pressure injury differential diagnosis and categorisation of severe injuries were inadequate. RELEVANCE TO CLINICAL PRACTICE: These results may be used for benchmarking and provide a focal point for future education and practice improvement efforts. PATIENT OR PUBLIC CONTRIBUTION: Neither patients nor the public were directly involved in the project.


Asunto(s)
Úlcera por Presión , Adulto , Humanos , Centros de Atención Terciaria , Hospitalización , Incidencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA