RESUMEN
PURPOSE: Robust implementation of spiral imaging requires efficient deblurring. A deblurring method was previously proposed to separate and deblur water and fat simultaneously, based on image-space kernel operations. The goal of this work is to improve the performance of the previous deblurring method using kernels with better properties. METHODS: Four types of kernels were formed using different models for the region outside the collected k-space as well as low-pass preconditioning (LP). The performances of the kernels were tested and compared with both phantom and volunteer data. Data were also synthesized to evaluate the SNR. RESULTS: The proposed "square" kernels are much more compact than the previously used circular kernels. Square kernels have better properties in terms of normalized RMS error, structural similarity index measure, and SNR. The square kernels created by LP demonstrated the best performance of artifact mitigation on phantom data. CONCLUSIONS: The sizes of the blurring kernels and thus the computational cost can be reduced by the proposed square kernels instead of the previous circular ones. Using LP may further enhance the performance.
Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Fantasmas de ImagenRESUMEN
PURPOSE: The aim of this work is to develop an ω-3 fatty acid fraction mapping method at 3 T based on a chemical shift encoding model, to assess its performance in a phantom and in vitro study, and to further demonstrate its feasibility in vivo. METHODS: A signal model was heuristically derived based on spectral appearance and theoretical considerations of the corresponding molecular structures to differentiate between ω-3 and non-ω-3 fatty acid substituents in triacylglycerols in addition to the number of double bonds (ndb), the number of methylene-interrupted double bonds (nmidb), and the mean fatty acid chain length (CL). First, the signal model was validated using single-voxel spectroscopy and a time-interleaved multi-echo gradient-echo (TIMGRE) sequence in gas chromatography-mass spectrometry (GC-MS)-calibrated oil phantoms. Second, the TIMGRE-based method was validated in vitro in 21 adipose tissue samples with corresponding GC-MS measurements. Third, an in vivo feasibility study was performed for the TIMGRE-based method in the gluteal region of two healthy volunteers. Phantom and in vitro data was analyzed using a Bland-Altman analysis. RESULTS: Compared with GC-MS, MRS showed in the phantom study significant correlations in estimating the ω-3 fraction (p < 0.001), ndb (p < 0.001), nmidb (p < 0.001), and CL (p = 0.001); MRI showed in the phantom study significant correlations (all p < 0.001) for the ω-3 fraction, ndb, and nmidb, but no correlation for CL. Also in the in vitro study, significant correlations (all p < 0.001) between MRI and GC-MS were observed for the ω-3 fraction, ndb, and nmidb, but not for CL. An exemplary ROI measurement in vivo in the gluteal subcutaneous adipose tissue yielded (mean ± standard deviation) 0.8% ± 1.9% ω-3 fraction. CONCLUSION: The present study demonstrated strong correlations between gradient-echo imaging-based ω-3 fatty acid fraction mapping and GC-MS in the phantom and in vitro study. Furthermore, feasibility was demonstrated for characterizing adipose tissue in vivo.
Asunto(s)
Ácidos Grasos Omega-3 , Estudios de Factibilidad , Imagen por Resonancia Magnética , Fantasmas de Imagen , Ácidos Grasos Omega-3/química , Humanos , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Masculino , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/química , Cromatografía de Gases y Espectrometría de MasasRESUMEN
PURPOSE: The goal of this work is to present the implementation of 3D spiral high-resolution MPRAGE and to demonstrate that SNR and scan efficiency increase with the increment of readout time. THEORY: Simplified signal equations for MPRAGE indicate that the T1 contrast can be kept approximately the same by a simple relationship between the flip angle and the TR. Furthermore, if T1 contrast remains the same, image SNR depends on the square root of the product of the total scan time and the readout time. METHODS: MPRAGE spiral sequences were implemented with distributed spirals and spiral staircase on 3 Tesla scanners. Brain images of three volunteers were acquired with different readout times. Spiral images were processed with a joint water-fat separation and deblurring algorithm and compared to Cartesian images. Pure noise data sets were also acquired for SNR evaluation. RESULTS: Consistent T1 weighting can be achieved with various spiral readout lengths, and between spiral MPRAGE imaging and the traditional Cartesian MPRAGE imaging. Noise performance analysis demonstrates higher SNR efficiency of spiral MPRAGE imaging with matched T1 contrast compared to the Cartesian reference imaging. CONCLUSION: Fast, high SNR MPRAGE imaging is feasible with long readout spiral trajectories.
Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Encéfalo/diagnóstico por imagen , Agua , AlgoritmosRESUMEN
PURPOSE: This work proposes a 2D/3D hybrid inflow MRA technique for fast scanning and high SNR and contrast-to-noise (CNR) efficiencies. METHODS: Localized quadratic (LQ) encoding was combined with a sliding-slice spiral acquisition. Inflow MRAs around the circle of Willis and the carotid bifurcations were collected on four healthy volunteers. Spiral images were deblurred without or with water-fat separation for sliding-slice LQ (ssLQ) out-of-phase (OP) and Dixon inflow MRAs, respectively. Results were compared to multiple overlapping thin slab acquisitions (MOTSA) and 2D OP inflow MRAs. Noise data were also acquired with RF and gradients turned off to compute maps of SNR and SNR efficiency. Quantitative assessment of relative contrast, CNR, and CNR efficiency for flow were performed in regions of interest. RESULTS: The sliding-slice spiral technique alone reduces scan time by 10% to 40% compared with a standard spiral acquisition scheme. The proposed spiral ssLQ OP achieves 50% higher scan speed than the spiral MOTSA with comparable SNR and CNR efficiencies, which are â¼100% higher than the Cartesian MOTSA for intracranial inflow MRAs. Spiral ssLQ Dixon inflow MRA provides better visibility for vessels around the fat compared to spiral ssLQ OP inflow MRA, with a trade-off of scan speed. Spiral ssLQ MRA with thinner slice thickness is two to five times faster than the 2D Cartesian inflow neck MRA around the carotid bifurcations, while also achieving higher SNR efficiency. CONCLUSION: The proposed spiral ssLQ is a fast and flexible MRA method with improved SNR and CNR efficiencies over traditional Cartesian inflow MRAs.
Asunto(s)
Arterias Carótidas , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Arterias Carótidas/diagnóstico por imagen , Voluntarios Sanos , Agua , Imagenología Tridimensional/métodosRESUMEN
PURPOSE: This work aims to develop an approach for simultaneous water-fat separation and myocardial T1 and T2 quantification based on the cardiac MR fingerprinting (cMRF) framework with rosette trajectories at 3T and 1.5T. METHODS: Two 15-heartbeat cMRF sequences with different rosette trajectories designed for water-fat separation at 3T and 1.5T were implemented. Water T1 and T2 maps, water image, and fat image were generated with B0 inhomogeneity correction using a B0 map derived from the cMRF data themselves. The proposed water-fat separation rosette cMRF approach was validated in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and water/oil phantoms. It was also applied for myocardial tissue mapping of healthy subjects at both 3T and 1.5T. RESULTS: Water T1 and T2 values measured using rosette cMRF in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom agreed well with the reference values. In the water/oil phantom, oil was well suppressed in the water images and vice versa. Rosette cMRF yielded comparable T1 but 2~3 ms higher T2 values in the myocardium of healthy subjects than the original spiral cMRF method. Epicardial fat deposition was also clearly shown in the fat images. CONCLUSION: Rosette cMRF provides fat images along with myocardial T1 and T2 maps with significant fat suppression. This technique may improve visualization of the anatomical structure of the heart by separating water and fat and could provide value in diagnosing cardiac diseases associated with fibrofatty infiltration or epicardial fat accumulation. It also paves the way toward comprehensive myocardial tissue characterization in a single scan.
Asunto(s)
Corazón , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Agua , Corazón/diagnóstico por imagen , Humanos , Miocardio , Fantasmas de Imagen , Reproducibilidad de los ResultadosRESUMEN
PURPOSE: There is an absence of reproducibility studies on MRI-based body composition analysis in current literature. Therefore, the aim of this study was to investigate the between-scanner reproducibility and the repeatability of a method for MRI-based body composition analysis. METHODS: Eighteen healthy volunteers of varying body mass index and adiposity were each scanned twice on five different 1.5T and 3T scanners from three different vendors. Two-point Dixon neck-to knee images and two additional liver scans were acquired with similar protocols. Visceral adipose tissue (VAT) volume, abdominal subcutaneous adipose tissue (ASAT) volume, thigh muscle volume, and muscle fat infiltration (MFI) in the thigh muscle were measured. Liver proton density fat fraction (PDFF) was assessed using two different methods, the scanner vendor's 6-point method and an in-house 2-point method. Within-scanner test-retest repeatability and between-scanner reproducibility were calculated using analysis of variance. RESULTS: Repeatability coefficients were 13 centiliters (cl) (VAT), 24 cl (ASAT), 17 cl (total thigh muscle volume), 0.53% (MFI), and 1.27-1.37% for liver PDFF. Reproducibility coefficients were 24 cl (VAT), 42 cl (ASAT), 31 cl (total thigh muscle volume), 1.44% (MFI), and 2.37-2.40% for liver PDFF. CONCLUSION: For all measures except MFI, the within-scanner repeatability explained much of the overall reproducibility. The two methods for measuring liver fat had similar reproducibility. This study showed that the investigated method eliminates effects due to scanner differences. The results can be used for power calculations in clinical studies or to better understand the scanner-induced variability in clinical applications.
Asunto(s)
Composición Corporal , Imagen por Resonancia Magnética , Tejido Adiposo/diagnóstico por imagen , Humanos , Hígado , Reproducibilidad de los ResultadosRESUMEN
OBJECTIVES: To investigate the feasibility of employing a 3D time-interleaved multi-echo gradient-echo (TIMGRE) sequence to measure the proton density fat fraction (PDFF) in the vertebral bone marrow (VBM) of children and to examine cross-sectional changes with age and intra-individual variations from the lumbar to the cervical region in the first two decades of life. MATERIALS AND METHODS: Quantitative water-fat imaging of the spine was performed in 93 patients (49 girls; 44 boys; age median 4.5 years; range 0.1-17.6 years). For data acquisition, a six-echo 3D TIMGRE sequence was used with phase correction and complex-based water-fat separation. Additionally, single-voxel MR spectroscopy (MRS) was performed in the L4 vertebrae of 37 patients. VBM was manually segmented in the midsagittal slice of each vertebra. Univariable and multivariable linear regression models were calculated between averaged lumbar, thoracic and cervical bone marrow PDFF and age with adjustments for sex, height, weight, and body mass index percentile. RESULTS: Measured VBM PDFF correlated strongly between imaging and MRS (R 2 = 0.92, slope = 0.94, intercept = -0.72%). Lumbar, thoracic and cervical VBM PDFF correlated significantly (all p < 0.001) with the natural logarithm of age. Differences between female and male patients were not significant (p > 0.05). CONCLUSION: VBM development in children showed a sex-independent cross-sectional increase of PDFF correlating with the natural logarithm of age and an intra-individual decrease of PDFF from the lumbar to the cervical region in all age groups. The present results demonstrate the feasibility of using a 3D TIMGRE sequence for PDFF assessment in VBM of children.
Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/metabolismo , Médula Ósea/diagnóstico por imagen , Médula Ósea/metabolismo , Imagen por Resonancia Magnética/métodos , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/metabolismo , Adolescente , Factores de Edad , Niño , Preescolar , Estudios Transversales , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional , Lactante , Metabolismo de los Lípidos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Valores de Referencia , Agua/metabolismoRESUMEN
Quantifying muscle water T2 (T2 -water) independently of intramuscular fat content is essential in establishing T2 -water as an outcome measure for imminent new therapy trials in neuromuscular diseases. IDEAL-CPMG combines chemical shift fat-water separation with T2 relaxometry to obtain such a measure. Here we evaluate the reproducibility and B1 sensitivity of IDEAL-CPMG T2 -water and fat fraction (f.f.) values in healthy subjects, and demonstrate the potential of the method to quantify T2 -water variation in diseased muscle displaying varying degrees of fatty infiltration. The calf muscles of 11 healthy individuals (40.5 ± 10.2 years) were scanned twice at 3 T with an inter-scan interval of 4 weeks using IDEAL-CPMG, and 12 patients with hypokalemic periodic paralysis (HypoPP) (42.3 ± 11.5 years) were also imaged. An exponential was fitted to the signal decay of the separated water and fat components to determine T2 -water and the fat signal amplitude muscle regions manually segmented. Overall mean calf-level muscle T2 -water in healthy subjects was 31.2 ± 2.0 ms, without significant inter-muscle differences (p = 0.37). Inter-subject and inter-scan coefficients of variation were 5.7% and 3.2% respectively for T2 -water and 41.1% and 15.4% for f.f. Bland-Altman mean bias and ±95% coefficients of repeatability were for T2 -water (0.15, -2.65, 2.95) ms and f.f. (-0.02, -1.99, 2.03)%. There was no relationship between T2 -water (ρ = 0.16, p = 0.07) or f.f. (ρ = 0.03, p = 0.7761) and B1 error or any correlation between T2 -water and f.f. in the healthy subjects (ρ = 0.07, p = 0.40). In HypoPP there was a measurable relationship between T2 -water and f.f. (ρ = 0.59, p < 0.001). IDEAL-CPMG provides a feasible way to quantify T2 -water in muscle that is reproducible and sensitive to meaningful physiological changes without post hoc modeling of the fat contribution. In patients, IDEAL-CPMG measured elevations in T2 -water and f.f. while showing a weak relationship between these parameters, thus showing promise as a practical means of quantifying muscle water in patient populations.
Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Agua Corporal/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Debilidad Muscular/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Adulto , Algoritmos , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por ComputadorRESUMEN
PURPOSE: To investigate the precision, accuracy, and repeatability of water/fat imaging-based fat quantification in muscle tissue using a large flip angle (FA) and a fat reference for the calculation of the proton density fat fraction (FF). Comparison is made to a small FA water reference approach. MATERIALS AND METHODS: An Intralipid phantom and both forearms of six patients suffering from lymphedema and 10 healthy volunteers were investigated at 1.5T. Two multigradient-echo sequences with eight echo times and FAs of 10° and 85° were acquired. For healthy volunteers, the acquisition of the right arm was performed twice with repositioning. From each set, water reference FF and fat reference FF images were reconstructed and the average FF and the standard deviation were calculated within the subfascial compartment. The small FA water reference was considered the reference standard. RESULTS: A high agreement was found between the small FA water reference and large FA fat reference methods (FF bias = 0.31%). In this study, the large FA fat reference approach also resulted in higher precision (38% smaller FF standard deviation in homogenous muscle tissue), but no significant difference in repeatability between the various methods was detected (coefficient of repeatability of small FA water reference approach 0.41%). CONCLUSION: The precision of fat quantification in muscle tissue can be increased with maintained accuracy using a larger flip angle, if a fat reference instead of a water reference is used.
Asunto(s)
Tejido Adiposo/anatomía & histología , Tejido Adiposo/fisiología , Adiposidad/fisiología , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/anatomía & histología , Músculo Esquelético/fisiología , Algoritmos , Agua Corporal/metabolismo , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
PURPOSE: The Dixon techniques provide uniform water-fat separation but require multiple image sets, which extend the overall acquisition time. Here, an alternative rapid single acquisition method, lipid elimination with an echo-shifting N/2-ghost acquisition (LEENA), was introduced. METHODS: The LEENA method utilized a fast imaging with steady-state free precession sequence to obtain a single k-space dataset in which successive k-space lines are acquired to allow the fat magnetization to precess 180°. The LEENA data were then unghosted using either image-domain (LEENA-S) or k-space domain (LEENA-G) parallel imaging techniques to reconstruct water-only and fat-only images. An off-resonance correction technique was incorporated to improve the uniformity of the water-fat separation. RESULTS: Uniform water-fat separation was achieved for both the LEENA-S and LEENA-G methods for phantom and human body and leg imaging applications at 1.5T and 3T. The resultant water and fat images were qualitatively similar to conventional 2-point Dixon and fat-suppressed images. CONCLUSION: The LEENA-S and LEENA-G methods provide uniform water and fat images from a single MRI acquisition. These straightforward methods can be adapted to 1.5T and 3T clinical MRI scanners and provide comparable fat/water separation with conventional 2-point Dixon and fat-suppression techniques.
Asunto(s)
Tejido Adiposo/anatomía & histología , Artefactos , Aumento de la Imagen/métodos , Lípidos/análisis , Imagen por Resonancia Magnética/métodos , Técnica de Sustracción , Algoritmos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
PURPOSE: The purpose of this work was to improve the robustness of existing chemical shift encoded water-fat separation methods by incorporating object-based information of the B0 field inhomogeneity. THEORY: The primary challenge in water-fat separation is the estimation of phase shifts that arise from B0 field inhomogeneity, which is composed of the background field and susceptibility-induced field. The susceptibility-induced field can be estimated if the susceptibility distribution is known or can be approximated. In this work, the susceptibility distribution is approximated from the source images using the known susceptibility values of water, fat, and air. The field estimate is then demodulated from the source images before water-fat separation. METHODS: Chemical shift encoded source images were acquired in anatomical regions that are prone to water-fat swaps. The images were processed using algorithms from the ISMRM Fat-Water Toolbox, with and without the object-based field map information. The estimates were compared to examine the benefit of using the object-based field map information. RESULTS: Multiple cases are shown in which water-fat swaps were avoided by using the object-based information of the B0 field map. CONCLUSION: Object-based information of the B0 field may improve the robustness of existing chemical shift encoded water-fat separation methods.
Asunto(s)
Tejido Adiposo/anatomía & histología , Tobillo/anatomía & histología , Agua Corporal/citología , Plexo Braquial/anatomía & histología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
UNLABELLED: In aging, the bone marrow fills with fat and this may lead to higher fracture risk. We show that a bone marrow fat measurement by magnetic resonance spectroscopy (MRS), a newer technique not previously studied in chronic kidney disease (CKD), is useful and reproducible. CKD patients have significantly higher bone marrow fat than healthy adults. INTRODUCTION: Renal osteodystrophy leads to increased morbidity and mortality in patients with CKD. Traditional bone biopsy histomorphometry is used to study abnormalities in CKD, but the bone marrow, the source of osteoblasts, has not been well characterized in patients with CKD. METHODS: To determine the repeatability of bone marrow fat fraction assessment by MRS and water-fat imaging (WFI) at four sites in patients with CKD, testing was performed to determine the coefficients of reproducibility and intraclass coefficients (ICCs). We further determined if this noninvasive technique could be used to determine if there are differences in the percent bone marrow fat in patients with CKD compared to matched controls using paired t tests. RESULTS: The mean age of subjects with CKD was 59.8 ± 7.2 years, and the mean eGFR was 24 ± 8 ml/min. MRS showed good reproducibility at all sites in subjects with CKD and controls, with a coefficient of reproducibilities ranging from 2.4 to 13 %. MRS and WFI assessment of bone marrow fat showed moderate to strong agreement (ICC 0.6-0.7) at the lumbar spine, with poorer agreement at the iliac crest and no agreement at the tibia. The mean percent bone marrow fat at L2-L4 was 13.8 % (95 % CI 8.3-19.7) higher in CKD versus controls (p < 0.05). CONCLUSIONS: MRS is a useful and reproducible technique to study bone marrow fat in CKD. Patients with CKD have significantly higher bone marrow fat than healthy adults; the relationship with bone changes requires further analyses.
Asunto(s)
Tejido Adiposo/patología , Médula Ósea/patología , Insuficiencia Renal Crónica/patología , Anciano , Estudios de Casos y Controles , Nefropatías Diabéticas/patología , Nefropatías Diabéticas/fisiopatología , Femenino , Tasa de Filtración Glomerular , Humanos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Insuficiencia Renal Crónica/fisiopatología , Reproducibilidad de los ResultadosRESUMEN
PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneities METHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons. RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pintâ¡≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6). CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.
Asunto(s)
Tejido Adiposo/anatomía & histología , Artefactos , Agua Corporal/metabolismo , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/anatomía & histología , Músculo Esquelético/metabolismo , Adulto , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Técnica de SustracciónRESUMEN
BACKGROUND: The assessment of bone marrow composition has recently gained significant attention due to its association with bone loss pathophysiology and cancer therapy-induced bone marrow damage. The purpose of our study was to investigate the anatomical variation of the vertebral bone marrow fat using chemical shift-encoding based water-fat MRI and to assess the repeatability of these measurements. METHODS: Chemical shift-encoding based water-fat MRI of the whole spine was performed in 28 young, healthy subjects (17 males, 11 females, 26 ± 4 years). Six subjects were scanned three times with repositioning to assess the repeatability of these measurements. Proton density fat fraction (PDFF) maps were computed and manually segmented to obtain PDFF of C3-L5. RESULTS: Mean PDFF of all subjects significantly increased from C3 to L5 (P < 0.05) with r = 0.88 (P < 0.05). PDFF averaged over C3-7, T1-6, T7-12, and L1-5 of males and females amounted to 31.7 ± 7.9% and 23.0 ± 7.8% (P = 0.002), 33.8 ± 6.8% and 24.6 ± 8.8% (P = 0.005), 33.8 ± 6.4% and 26.1 ± 6.4% (P = 0.023), and 38.8 ± 7.6% and 31.5 ± 12.4% (P = 0.063), respectively. The repeatability for PDFF measurements expressed as absolute precision error was 1.7% averaged over C3-L5. CONCLUSION: Whole spine vertebral bone marrow fat could be reproducibly assessed by using chemical shift-encoding based water-fat MRI and showed anatomical variations.
Asunto(s)
Tejido Adiposo/anatomía & histología , Médula Ósea/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Columna Vertebral/anatomía & histología , Tejido Adiposo/fisiología , Adiposidad/fisiología , Adulto , Algoritmos , Médula Ósea/fisiología , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Columna Vertebral/fisiología , Agua/análisis , Imagen de Cuerpo Entero , Adulto JovenRESUMEN
PURPOSE: To investigate various sources of bias in MRI-based quantification of fat fraction (FF) and fatty acid composition (FAC) using chemical shift-encoded techniques. METHODS: Signals from various FFs and FACs and individual relaxation rates of all signal components were simulated. From these signals, FF and FAC parameters were estimated with and without correction for differences in individual relaxation rates. In addition, phantom experiments were conducted with various flip angles and number of echoes to validate the simulations. RESULTS: As expected, T(1) weighting resulted in an overestimation of the FF, but had much smaller impact on the FAC parameters. Differences in T(2) values of the signal components resulted in overestimation of the FAC parameters in fat/water mixtures, whereas the estimation in pure oil was largely unaffected. This bias was corrected using a simplified signal model with different T(2) values of water and fat, where the accuracy of the modeled T(2) of water was critical. The results of the phantom experiment were in agreement with simulations. CONCLUSION: T(1) weighting has only a minor effect on FAC quantification in both fat/water mixtures and pure oils. T(2) weighting is mainly a concern in fat/water mixtures but may be corrected using a simplified model.
Asunto(s)
Tejido Adiposo/química , Ácidos Grasos/química , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Simulación por Computador , Fantasmas de ImagenRESUMEN
PURPOSE: Breath-holding is an established strategy for reducing motion artifacts in abdominal imaging. However, the breath-holding capabilities of patients are often overstrained by scans with large coverage and high resolution. In this work, a new strategy for coping with resulting incomplete breath-holds in abdominal imaging is suggested. METHODS: A sampling pattern is designed to support image reconstruction from undersampled data acquired up to any point in time using compressed sensing and parallel imaging. In combination with a navigator-based detection of the onset of respiration, it allows scan termination and thus reconstruction only from consistent data, which suppresses motion artifacts. The spatial resolution is restricted by a lower bound of the sampling density and is increased over the scan, to strike a compromise with the signal-to-noise ratio and undersampling artifacts for any breath-hold duration. RESULTS: The sampling pattern is optimized in phantom experiments and is successfully applied in abdominal gradient-echo imaging including water-fat separation on volunteers. CONCLUSIONS: The new strategy provides images in which motion artifacts are minimized independent of the breath-holding capabilities of patients, and which enhance in terms of spatial resolution, signal-to-noise ratio, and undersampling artifacts with the a priori unknown breath-hold duration actually achieved in a particular scan.
Asunto(s)
Abdomen/anatomía & histología , Algoritmos , Artefactos , Contencion de la Respiración , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Mecánica Respiratoria , Adulto , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
Radial trajectories facilitate high-resolution balanced steady state free precession (bSSFP) because the efficient gradients provide more time to extend the trajectory in k-space. A number of radial bSSFP methods that support fat-water separation have been developed; however, most of these methods require an environment with limited B0 inhomogeneity. In this work, high-resolution bSSFP with fat-water separation is achieved in more challenging B0 environments by combining a 3D radial trajectory with the IDEAL chemical species separation method. A method to maintain very high resolution within the timing constraints of bSSFP and IDEAL is described using a dual-pass pulse sequence. The sampling of a unique set of radial lines at each echo time is investigated as a means to circumvent the longer scan time that IDEAL incurs as a multiecho acquisition. The manifestation of undersampling artifacts in this trajectory and their effect on chemical species separation are investigated in comparison to the case in which each echo samples the same set of radial lines. This new bSSFP method achieves 0.63 mm isotropic resolution in a 5-min scan and is demonstrated in difficult in vivo imaging environments, including the breast and a knee with ACL reconstruction hardware at 1.5 T.
Asunto(s)
Algoritmos , Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/patología , Mama/anatomía & histología , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Ligamento Cruzado Anterior/cirugía , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
OBJECTIVES: To compare thigh muscle intramuscular fat (intraMF) fractions and area between people with and without knee radiographic osteoarthritis (ROA); and to evaluate the relationships of quadriceps adiposity and area with strength, function and knee magnetic resonance imaging (MRI) lesions. METHODS: Ninety six subjects (ROA: Kellgren-Lawrence (KL) > 1; n = 30, control: KL = 0, 1; n = 66) underwent 3-T MRI of the thigh muscles using chemical shift-based water/fat MRI (fat fractions) and the knee (clinical grading). Subjects were assessed for isometric/isokinetic quadriceps/hamstrings strength, function Knee injury and Osteoarthritis Outcome Score (KOOS), stair climbing test (SCT), and 6-minute walk test (6MWT). Thigh muscle intraMF fractions, muscle area and strength, and function were compared between controls and ROA subjects, adjusting for age. Relationships between measures of muscle fat/area with strength, function, KL and lesion scores were assessed using regression and correlational analyses. RESULTS: The ROA group had worse KOOS scores but SCT and 6MWT were not different. The ROA group had greater quadriceps intraMF fraction but not for other muscles. Quadriceps strength was lower in ROA group but the area was not different. Quadriceps intraMF fraction but not area predicted self-reported disability. Aging, worse KL, and cartilage and meniscus lesions were associated with higher quadriceps intraMF fraction. CONCLUSION: Quadriceps intraMF is higher in people with knee OA and is related to symptomatic and structural severity of knee OA, whereas the quadriceps area is not. Quadriceps fat fraction from chemical shift-based water/fat MR imaging may have utility as a marker of structural and symptomatic severity of knee OA disease process.
Asunto(s)
Tejido Adiposo/patología , Osteoartritis de la Rodilla/patología , Músculo Cuádriceps/patología , Adiposidad/fisiología , Adulto , Anciano , Envejecimiento/patología , Envejecimiento/fisiología , Cartílago Articular/fisiopatología , Estudios de Casos y Controles , Prueba de Esfuerzo/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Fuerza Muscular/fisiología , Osteoartritis de la Rodilla/fisiopatología , Músculo Cuádriceps/fisiopatología , Índice de Severidad de la Enfermedad , Tendones/fisiopatología , Muslo/patologíaRESUMEN
PURPOSE: To compare the total breast fat content computed from two separate studies, performed on different scanners and with different protocols, with the goal of defining a relationship to allow pooling the data. MATERIALS AND METHODS: Twelve healthy volunteer women were scanned with two different protocols on the same day. The protocols differed in four important aspects: vendors (GE vs. Philips), scanner main magnetic field strengths (1.5T vs. 3T), pulse sequences (2D fast spin-echo vs. 3D spoiled gradient-echo), and water/fat separation techniques. The resulting water and fat maps were processed with in-house software to extract breast tissue slice-wise. Percent fat content was calculated for each breast, per subject. RESULTS: Total percent fat contents (averaged across both breasts) resulting from both protocols were plotted against each other, on a subject-by-subject basis, revealing a strong correlation (R(2) > 0.99), with an overestimation of the fat content from Protocol 1 relative to Protocol 2. The proposed T2 TE-correction for Protocol 1 improves the correlation while decreasing the discrepancy between protocols. CONCLUSION: Total breast fat content of healthy women resulting from the two protocols can be pooled using a linear relationship. The proposed T2 TE-corrected Protocol 1 is expected to yield accurate fat content.
Asunto(s)
Tejido Adiposo/anatomía & histología , Tejido Adiposo/fisiología , Adiposidad/fisiología , Mama/anatomía & histología , Mama/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto JovenRESUMEN
PURPOSE: To evaluate a chemical shift-based fat quantification technique in the rotator cuff muscles in comparison with the semiquantitative Goutallier fat infiltration classification (GC) and to assess their relationship with clinical parameters. MATERIALS AND METHODS: The shoulders of 57 patients were imaged using a 3T MR scanner. The rotator cuff muscles were assessed for fat infiltration using GC by two radiologists and an orthopedic surgeon. Sequences included oblique-sagittal T1-, T2-, and proton density-weighted fast spin echo, and six-echo gradient echo. The iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) was used to measure fat fraction. Pain and range of motion of the shoulder were recorded. RESULTS: Fat fraction values were significantly correlated with GC grades (P < 0.0001, κ >0.9) showing consistent increase with GC grades (grade = 0, 0%-5.59%; grade = 1, 1.1%-9.70%; grade = 2, 6.44%-14.86%; grade = 3, 15.25%-17.77%; grade = 4, 19.85%-29.63%). A significant correlation between fat infiltration of the subscapularis muscle quantified with IDEAL versus 1) deficit in internal rotation (Spearman Rank Correlation Coefficient [SRC] = 0.39, 95% confidence interval [CI] 0.13-0.60, P < 0.01) and 2) pain (SRC coefficient = 0.313, 95% CI 0.049-0.536, P = 0.02) was found but was not seen between the clinical parameters and GC grades. Additionally, only quantitative fat infiltration measures of the supraspinatus muscle were significantly correlated with a deficit in abduction (SRC coefficient = 0.45, 95% CI 0.20-0.60, P < 0.01). CONCLUSION: An accurate and highly reproducible fat quantification in the rotator cuff muscles using water-fat magnetic resonance imaging (MRI) techniques is possible and significantly correlates with shoulder pain and range of motion.