Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
BMC Anesthesiol ; 20(1): 94, 2020 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-32334537

RESUMEN

BACKGROUND: INTELLiVENT-ASV® (I-ASV) is a closed-loop ventilation mode that automatically controls the ventilation settings. Although a number of studies have reported the usefulness of I-ASV, the clinical situations in which it may be useful have not yet been clarified. We aimed to report our initial 3 years of experience using I-ASV, particularly the clinical conditions and the technical and organizational factors associated with its use. Furthermore, we evaluated the usefulness of I-ASV and determined the predictive factors for successful management with I-ASV. METHODS: This single-center, retrospective observational study included patients who were ventilated using the Hamilton G5® ventilator (Hamilton Medical AG, Rhäzüns, Switzerland) from January 2016 to December 2018. The patients were categorized into the "I-ASV success" group and "I-ASV failure" group (those receiving mechanical ventilation with I-ASV along with any other mode). Multivariate analysis was performed to identify factors associated with successful I-ASV management. RESULTS: Of the 189 patients, 135 (71.4%) were categorized into the I-ASV success group. In the I-ASV success group, the reasons for ICU admission included post-elective surgery (94.1%), post-emergent surgery (81.5%), and other medical reasons (55.6%). I-ASV failure was associated with a low P/F ratio (278 vs. 167, P = 0.0003) and high Acute Physiology and Chronic Health Evaluation (APACHE) II score (21 vs. 26, P < 0.0001). The main reasons for not using I-ASV included strong inspiratory effort and asynchrony. The APACHE II score was an independent predictive factor for successful management with I-ASV, with an odds ratio of 0.92 (95% confidential interval 0.87-0.96, P = 0.0006). The area under the receiver operating curve for the APACHE II score was 0.722 (cut-off: 24). CONCLUSIONS: In this study, we found that 71.4% of the fully mechanically ventilated patients could be managed successfully with I-ASV. The APACHE II score was an independent factor that could help predict the successful management of I-ASV. To improve I-ASV management, it is necessary to focus on patient-ventilator interactions.


Asunto(s)
Unidades de Cuidados Intensivos , Pulmón/metabolismo , Respiración Artificial/métodos , APACHE , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
2.
Artículo en Ruso | MEDLINE | ID: mdl-29076469

RESUMEN

PURPOSE: the study purpose was to evaluate the efficacy of the IntelliVent-ASV mode in maintaining the target range of PaCO2 in patients with severe TBI. MATERIAL AND METHODS: The study included 12 severe TBI patients with the wakefulness level scored 4-9 (GCS). This was a crossover design study. Two ventilation modes were consecutively used: IntelliVent-ASV and P-CMV, for 12 h each. When using the P-CMV mode, the ventilation parameters were set to maintain PaCO2 in a range of 35-38 mm Hg. The IntelliVent-ASV mode involved the Brain Injury ventilation algorithm. The target range of EtCO2 was set in accordance with the delta PaCO2-EtCO2 to maintain PaCO2 in a range of 35-38. At the beginning of each ventilation period and every 3 hours, the arterial blood gas composition was analyzed. When PaCO2 occurred out of the 35-38 range, appropriate adjustments were made to the ventilation parameters. In the P-CMV mode, the Pinsp and RR parameters were adjusted to achieve the target PaCO2 range. In IntelliVent mode, a shift of the target EtCO2 range was adjusted in accordance with a changed PaCO2-EtCO2 difference. In all patients, ICP, blood pressure, and EtCO2 were monitored; the arterial blood gas composition was analyzed every 3 h; the frequency of manual settings of ventilation parameters was recorded. RESULTS: The EtCO2 and PaCO2 parameters were found not to be significantly different in the P-CMV and IntelliVent modes, but the spread in these parameters was significantly lower in the IntelliVent ventilation mode. The PaCO2 parameter occurred out of the target range significantly less often in the IntelliVent mode than in the P-CMV mode. The mean frequency of manual respirator settings needed to maintain the target EtCO2 range was significantly lower in the IntelliVent-ASV mode than in the P-CMV mode. CONCLUSION: The IntelliVent-ASV mode provides more efficient maintenance of PaCO2 in the target range compared to traditional artificial ventilation using fewer manual settings of the ventilation parameters.


Asunto(s)
Algoritmos , Lesiones Traumáticas del Encéfalo/sangre , Lesiones Traumáticas del Encéfalo/terapia , Dióxido de Carbono/sangre , Respiración Artificial/métodos , Adulto , Análisis de los Gases de la Sangre/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración Artificial/instrumentación
3.
Trials ; 25(1): 449, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38961468

RESUMEN

BACKGROUND: One single-center randomized clinical trial showed that INTELLiVENT-adaptive support ventilation (ASV) is superior to conventional ventilation with respect to the quality of ventilation in post-cardiac surgery patients. Other studies showed that this automated ventilation mode reduces the number of manual interventions at the ventilator in various types of critically ill patients. In this multicenter study in patients post-cardiac surgery, we test the hypothesis that INTELLiVENT-ASV is superior to conventional ventilation with respect to the quality of ventilation. METHODS: "POStoperative INTELLiVENT-adaptive support VEntilation in cardiac surgery patients II (POSITiVE II)" is an international, multicenter, two-group randomized clinical superiority trial. In total, 328 cardiac surgery patients will be randomized. Investigators screen patients aged > 18 years of age, scheduled for elective cardiac surgery, and expected to receive postoperative ventilation in the ICU for longer than 2 h. Patients either receive automated ventilation by means of INTELLiVENT-ASV or ventilation that is not automated by means of a conventional ventilation mode. The primary endpoint is quality of ventilation, defined as the proportion of postoperative ventilation time characterized by exposure to predefined optimal, acceptable, and critical (injurious) ventilatory parameters in the first two postoperative hours. One major secondary endpoint is ICU team staff workload, captured by the ventilator software collecting manual settings on alarms. Patient-centered endpoints include duration of postoperative ventilation and length of stay in ICU. DISCUSSION: POSITiVE II is the first international, multicenter, randomized clinical trial designed to confirm that POStoperative INTELLiVENT-ASV is superior to non-automated conventional ventilation and secondary to determine if this closed-loop ventilation mode reduces ICU team staff workload. The results of POSITiVE II will support intensive care teams in their choices regarding the use of automated ventilation in postoperative care of uncomplicated cardiac surgery patients. TRIAL REGISTRATION: Clinicaltrials.gov NCT06178510 . Registered on December 4, 2023.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Estudios Multicéntricos como Asunto , Humanos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Estudios de Equivalencia como Asunto , Unidades de Cuidados Intensivos , Cuidados Posoperatorios/métodos , Respiración Artificial/métodos , Factores de Tiempo , Resultado del Tratamiento
4.
Trials ; 23(1): 348, 2022 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-35461264

RESUMEN

BACKGROUND: INTELLiVENT-Adaptive Support Ventilation (ASV) is a fully automated closed-loop mode of ventilation for use in critically ill patients. Evidence for benefit of INTELLiVENT-ASV in comparison to ventilation that is not fully automated with regard to duration of ventilation and quality of breathing is largely lacking. We test the hypothesis that INTELLiVENT-ASV shortens time spent on a ventilator and improves the quality of breathing. METHODS: The "Effects of Automated Closed-loop VenTilation versus Conventional Ventilation on Duration and Quality of Ventilation" (ACTiVE) study is an international, multicenter, two-group randomized clinical superiority trial. In total, 1200 intensive care unit (ICU) patients with an anticipated duration of ventilation of > 24 h will be randomly assigned to one of the two ventilation strategies. Investigators screen patients aged 18 years or older at start of invasive ventilation in the ICU. Patients either receive automated ventilation by means of INTELLiVENT-ASV, or ventilation that is not automated by means of a conventional ventilation mode. The primary endpoint is the number of days free from ventilation and alive at day 28; secondary endpoints are quality of breathing using granular breath-by-breath analysis of ventilation parameters and variables in a time frame of 24 h early after the start of invasive ventilation, duration of ventilation in survivors, ICU and hospital length of stay (LOS), and mortality rates in the ICU and hospital, and at 28 and 90 days. DISCUSSION: ACTiVE is one of the first randomized clinical trials that is adequately powered to compare the effects of automated closed-loop ventilation versus conventional ventilation on duration of ventilation and quality of breathing in invasively ventilated critically ill patients. The results of ACTiVE will support intensivist in their choices regarding the use of automated ventilation. TRIAL REGISTRATION: ACTiVE is registered in clinicaltrials.gov (study identifier: NCT04593810 ) on 20 October 2020.


Asunto(s)
Enfermedad Crítica , Respiración Artificial , Humanos , Unidades de Cuidados Intensivos , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Respiración , Respiración Artificial/métodos , Ventiladores Mecánicos
5.
J Clin Med ; 10(22)2021 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-34830691

RESUMEN

Driving pressure (ΔP) and mechanical power (MP) are associated with outcomes in critically ill patients, irrespective of the presence of Acute Respiratory Distress Syndrome (ARDS). INTELLiVENT-ASV, a fully automated ventilatory mode, controls the settings that affect ΔP and MP. This study compared the intensity of ventilation (ΔP and MP) with INTELLiVENT-ASV versus conventional ventilation in a cohort of COVID-19 ARDS patients in two intensive care units in the Netherlands. The coprimary endpoints were ΔP and MP before and after converting from conventional ventilation to INTELLiVENT-ASV. Compared to conventional ventilation, INTELLiVENT-ASV delivered ventilation with a lower ΔP and less MP. With conventional ventilation, ΔP was 13 cmH2O, and MP was 21.5 and 24.8 J/min, whereas with INTELLiVENT-ASV, ΔP was 11 and 10 cmH2O (mean difference -2 cm H2O (95 %CI -2.5 to -1.2 cm H2O), p < 0.001) and MP was 18.8 and 17.5 J/min (mean difference -7.3 J/Min (95% CI -8.8 to -5.8 J/min), p < 0.001). Conversion from conventional ventilation to INTELLiVENT-ASV resulted in a lower intensity of ventilation. These findings may favor the use of INTELLiVENT-ASV in COVID-19 ARDS patients, but future studies remain needed to see if the reduction in the intensity of ventilation translates into clinical benefits.

6.
Expert Rev Respir Med ; 15(11): 1403-1413, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34047244

RESUMEN

Introduction: INTELLiVENT-Adaptive Support Ventilation (INTELLiVENT-ASV), an advanced closed-loop ventilation mode for use in intensive care unit (ICU) patients, is equipped with algorithms that automatically adjust settings on the basis of physiologic signals and patient's activity. Here we describe its effectiveness, safety, and efficacy in various types of ICU patients.Areas covered: A systematic search conducted in MEDLINE, EMBASE, the Cochrane Central register of Controlled Trials (CENTRAL), and in Google Scholar identified 10 randomized clinical trials.Expert opinion: Studies suggest INTELLiVENT-ASV to be an effective automated mode with regard to the titrations of tidal volume, airway pressure, and oxygen. INTELLiVENT-ASV is as safe as conventional modes. However, thus far studies have not shown INTELLiVENT-ASV to be superior to conventional modes with regard to duration of ventilation and other patient-centered outcomes. Future studies are needed to test its efficacy.


Asunto(s)
Unidades de Cuidados Intensivos , Respiración Artificial , Cuidados Críticos , Humanos , Pulmón , Volumen de Ventilación Pulmonar
7.
Front Med (Lausanne) ; 4: 31, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28377920

RESUMEN

BACKGROUND: The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. MATERIALS AND METHODS: Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning (n = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning (n = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. RESULTS AND DISCUSSION: Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group (p < 0.01). The average time until tracheal extubation did not differ in the automated weaning and the protocolized weaning groups: 193 (115-309) and 197 (158-253) min, respectively, but increased to 290 (210-411) min in the standard weaning group. CONCLUSION: The automated weaning system after off-pump coronary surgery might provide postoperative ventilation in a more protective way, reduces the workload on medical staff, and does not prolong the duration of weaning from ventilator. The use of automated or protocolized weaning can reduce the duration of postoperative mechanical ventilation in comparison with non-protocolized weaning based on the physician's decision.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA