Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 484
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Biomed Eng Online ; 23(1): 36, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38504231

RESUMEN

BACKGROUND: The reduced treatment time of dental implants with immediate loading protocol is an appealing solution for dentists and patients. However, there remains a significant risk of early peri-implant bone response following the placement of immediately loaded implants, and limited information is available regarding loading directions and the associated in vivo characteristics of peri-implant bone during the early stages. This study aimed to investigate the effects of immediate loading directionality on the expression of mechanical sensing protein PIEZO1 and the healing process of peri-implant bone in the early stage. METHODS: Thirty-two implants were inserted into the goat iliac crest models with 10 N static lateral immediate loading applied, followed by histological, histomorphological, immunohistochemical, X-ray microscopy and energy dispersive X-ray spectroscopy evaluations conducted after 10 days. RESULTS: From evaluations at the cellular, tissue, and organ levels, it was observed that the expression of mechanical sensing protein PIEZO1 in peri-implant bone was significantly higher in the compressive side compared to the tensile side. This finding coincided with trends observed in interfacial bone extracellular matrix (ECM) contact percentage, bone mass, and new bone formation. CONCLUSIONS: This study provides a novel insight into the immediate loading directionality as a potential influence factor for dental implant treatments by demonstrating differential effects on the mechanical sensing protein PIEZO1 expression and related early-stage healing processes of peri-implant bone. Immediate loading directions serve as potential therapeutic influence factors for peri-implant bone during its early healing stage.


Asunto(s)
Implantes Dentales , Cicatrización de Heridas , Humanos , Prótesis e Implantes , Canales Iónicos
2.
Clin Oral Implants Res ; 35(2): 201-219, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38050349

RESUMEN

OBJECTIVE: Evaluate the long-term outcomes of full-arch rehabilitation using immediate dental implant placement and continuous functional loading with full-fixed dental prostheses (FFDPs). MATERIALS AND METHODS: Fifty-six patients received temporary implants (n = 327) at maxillary augmentation with calvarial bone. A provisional acrylic FFDP was immediately loaded onto these implants. After 6 months, the temporary implants were replaced with definitive implants (n = 326) and immediately loaded with a second provisional FFDP (N = 55). Subsequently, a baseline radiograph was taken following a 6-month healing period. The second bridge was then substituted with a definitive FFDP. Primary outcomes included peri-implant marginal bone level (MBL) and definitive implant survival. Secondary outcomes evaluated provisional implant and prostheses survival, complications, and patient satisfaction. RESULTS: The provisional implants had a survival rate of 97.9%. One patient was excluded from further analysis due to loss of temporary implants and first FFDP. The definitive implant survival rate after 10 years was 92.2%, with a moderate but significant decrease in MBL between baseline radiography and 10 years later (-0.08 ± 0.18 vs. -0.24 ± 0.44). However, large individual variations were observed, with 65.8% of implants showing no bone loss and 9.2% showing loss ≥0.5 mm. Sinusitis was experienced by 14.3% of patients upon surgery. Patient satisfaction was high or reported no issues after protocol completion (80%). One patient lost all six definitive implants and definitive FFDP 8.2 years after implant placement. CONCLUSIONS: The described protocol can be regarded as a long-term, highly successful method for full-arch rehabilitation of atrophied maxillae while enabling continuous masticatory and speaking functionality.


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Implantación Dental Endoósea/métodos , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Estudios Retrospectivos , Prótesis Dental de Soporte Implantado , Resultado del Tratamiento , Fracaso de la Restauración Dental , Estudios de Seguimiento
3.
Clin Oral Investig ; 28(8): 460, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39083185

RESUMEN

OBJECTIVES: Evaluate the 5-year safety and efficacy of a narrow-diameter (3.0 mm) implant that was immediately provisionalized with a single crown in the maxillary lateral incisor or mandibular central or lateral incisor area. MATERIALS AND METHODS: An open, prospective, single-cohort, multicenter study was conducted, in which narrow-diameter implants were placed in fresh, healed extraction, or congenitally missing sites. All patients were required to meet strict criteria for immediate loading. The primary endpoints were marginal bone levels (MBL) and MBL changes (MBLC) from implant placement to 5-year follow-up. Secondary endpoints included cumulative 5-year survival and success rates, soft tissue health, and esthetic parameters. RESULTS: A total of 91 implants were placed in 77 patients. The mean MBL remained stable from the 1-year (- 0.79 ± 0.73 mm, n = 75) to 5-year (- 0.74 ± 0.87 mm, n = 65) follow-up. A marginal bone gain of 0.11 ± 0.83 mm was observed from the 1-year to 5-year follow-up. The cumulative 5-year survival rate was 96.5%, and the cumulative 5-year success rate was 93%. The clinical parameters, including the modified plaque index, modified sulcus bleeding index, Jemt's papilla index, and pink esthetic score improved throughout the 5-year study. CONCLUSIONS: The study demonstrated that narrow-diameter implants represent a safe and predictable treatment option for subjects suitable for immediate loading and with limited bone volume or limited inter-dental space. CLINICAL RELEVANCE: Narrow-diameter implants with immediate provisionalization can be considered for use to restore missing or damaged teeth with predictable functional and esthetic outcomes. This trial was registered with ClinicalTrials.gov (NCT02184845).


Asunto(s)
Coronas , Diseño de Prótesis Dental , Estética Dental , Carga Inmediata del Implante Dental , Humanos , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Resultado del Tratamiento , Implantes Dentales de Diente Único , Incisivo , Anciano
4.
J Esthet Restor Dent ; 36(1): 197-206, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37975525

RESUMEN

OBJECTIVE: Despite the wide clinical use of translucent zirconia for full-arch implant prostheses, reduced flexural strength and fracture toughness compared with high-strength opaque zirconia needs to be addressed. A novel proof of concept for FP1 full-arch prosthesis featured by translucent monolithic zirconia and titanium framework was presented. CLINICAL CONSIDERATIONS: Computer-guided implant planning and surgery were executed and digitally designed FP1 temporary prosthesis prefabricated. Implant and prosthetic placement were achieved with a set of three-dimensional (3D)-printed templates. Implants were immediately loaded. After 4 months intraoral optical scan was taken to record implant coordinates, soft tissue anatomy, and temporary FP1 prosthesis. A novel digital workflow was used to design and mill overlaying translucent zirconia and anatomically shaped titanium framework with a scalloped soft-tissue interface. Final FP1 prosthesis was assembled cementing zirconia jacket on titanium counterpart. CONCLUSIONS: Translucent zirconia supported by titanium framework can address esthetic and mechanical requirements of FP1 full-arch prosthesis, minimizing risk of fracture and providing a rigid and passive joint with supporting implants. The smooth and highly polished titanium surface with an anatomic design, tightly matching scalloped soft tissue interface, can limit food impaction, air and saliva leakage and contribute to overall biologic integration of FP1 full-arch prosthesis. CLINICAL SIGNIFICANCE: Translucent monolithic zirconia featured with anatomically shaped titanium framework with scalloped transmucosal part, combining a pleasant esthetic outcome with increased flexural strength and fracture toughness, may be indicated to increase the clinical performance of FP1 full-arch prosthesis.


Asunto(s)
Productos Biológicos , Implantes Dentales , Titanio , Diseño Asistido por Computadora , Prótesis Dental de Soporte Implantado , Estética Dental , Circonio
5.
J Esthet Restor Dent ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38591169

RESUMEN

OBJECTIVES: To evaluate clinical, clinician- and patient-reported outcomes (PROs) of two adjacent single posterior implants immediately loaded with definitive single crowns up to 1 year. Ten patients in need of two adjacent posterior single implants were included. All implants were placed applying a fully digital workflow. Definitive screw-retained single zirconia crowns were delivered within 72 h after implant placement. Clinical parameters, patient- and clinician-reported outcomes were assessed up to 1 year of follow-up. CLINICAL CONSIDERATIONS: Clinical outcomes remained stable, with no implant failures or technical and biological complications throughout the observation period. Patient satisfaction was very high at baseline (crown delivery) and remained consistently high at 6 and 12 months of follow-up. Crown insertion 3 days after implant placement was rated as an easy procedure by clinicians. CONCLUSIONS: Two adjacent single implants with immediate definitive restorations (<72 h) in the posterior region appear to be a viable and easy treatment option to shorten the overall treatment time and potentially enhancing patient satisfaction. However, randomized controlled trials are needed to confirm the advantages of this treatment protocol over a delayed loading approach. CLINICAL SIGNIFICANCE: In selected cases, immediate implant loading with definitive restorations in the posterior region appears a valuable and straightforward option to shorten the overall treatment time.

6.
J Prosthodont ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985142

RESUMEN

PURPOSE: This prospective case series aimed to investigate the effect of vertical alveoloplasty on the changes in keratinized mucosa width (KMW) following full-arch immediate implant placement and rehabilitation. MATERIALS AND METHODS: A total of 17 potential edentulous patients were enrolled and received implant placement and full-arch implant-supported immediate rehabilitations. The main outcome was to analyze the effect of vertical alveoloplasty on the changes in KMW. The amount of vertical alveoloplasty during implant surgery as well as the changes in KMW at buccal aspects from the day of surgery to 6 months post-surgery were recorded on the implant-level using a periodontal probe. The secondary outcome was to analyze the other possible factors that affected the changes in KMW. The included factors were the initial KMW, the distribution of implants in the maxilla and mandible, the distribution of implants in the anterior and posterior regions, the distribution of implants in extraction sockets and healed ridges, and gender. Mann-Whitney non-parametric tests and multiple linear regression adjusted by generalized estimating equations (GEE) were used to statistically analyze the data. RESULTS: A total of 121 implant positions were analyzed. The KMW was 4.1± 2.0 mm on the day of the surgery and 4.1± 1.7 mm 6 months post-surgery. The mean changes in KMW following 6 months were -0.1± 1.6 mm (p = 0.824). From the results of GEE, the vertical amount of alveoloplasty had no significant effect on changes in KMW. Both initial KMW and the distribution of implants in the anterior and posterior regions had significant impacts on the changes in KMW (p < 0.0001). CONCLUSION: The amount of vertical alveoloplasty during implant surgery has no significant impact on the KMW. The KMW remained stable from baseline to 6 months after alveoloplasty, implant placement, and immediate rehabilitations in potential edentulous arches. The initial KMW and the distribution of implants in the anterior and posterior regions were the possible factors affecting changes in KMW.

7.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38792903

RESUMEN

(1) Background: Recent digital workflows are being developed for full-arch rehabilitations supported by implants with immediate function. The purpose of this case series is to describe a new digital workflow for the All-on-4 concept. (2) Methods: The patients were rehabilitated using the All-on-4 concept with a digital workflow including computerized tomography scanning, intra-oral scanning, and CAD-CAM production of the temporary prosthesis, with the 3D printing of stackable guides (base guide, implant guide, and prosthetic guide). The passive fit of the prostheses and the time to perform the rehabilitations were evaluated. (3) Results: The digital workflow allowed for predictable bone reduction, the insertion of implants with immediate function, and the connection of an implant-supported prosthesis with immediate loading. The time registered to perform the full-arch rehabilitations (implant insertion, abutment connection, prosthesis connection) was below 2 hours and 30 min. No passive fit issues were noted. (4) Conclusions: within the limitation of this case series, the digital workflow applied to the All-on-4 concept using stackable base-, implant-, and prosthetic guides constitutes a potential alternative with decreased time for the procedure without prejudice of the outcome.


Asunto(s)
Flujo de Trabajo , Humanos , Femenino , Masculino , Persona de Mediana Edad , Diseño Asistido por Computadora , Anciano , Prótesis Dental de Soporte Implantado/métodos , Impresión Tridimensional , Tomografía Computarizada por Rayos X/métodos , Boca Edéntula/rehabilitación
8.
J Contemp Dent Pract ; 25(3): 213-220, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38690692

RESUMEN

AIM: The objective of this study was to assess marginal bone level around single implants inserted in fresh extraction sockets in the anterior maxillary region and instantly restored with computer-aided design/computer-aided manufacturing customized temporary crowns cemented on the final abutment. MATERIALS AND METHODS: A total of 20 patients (15 females and 5 males, with a mean age of 30 years), where 20 were placed in fresh extraction sockets. After raising a full-thickness flap, atraumatic extraction was performed the implant site was prepared and fixtures were stabilized on the palatal bone wall. The implant location was immediately transmitted to the prepared master model using the pick-up impression coping seated in the surgical guide template. Prefabricated abutments were used as the final abutment on the master model, scanned and the crown was planned using computer-aided manufacturing customized software. Later on 8th weeks, abutments were torqued as per the manufacturer's recommendation, and the final crowns were cemented. Using personalized intraoral radiographs marginal bone level was evaluated mesially and distally to the implant shoulder as a reference at implant placement, 8 weeks, 1, 3, 5, and 10 years after loading. RESULTS: Wholly implants were osteo-integrated positively after 10 years of practical loading, but only 18 were available for clinical and radiological follow-up, and 2 patients with two implants were excluded from the study due to relocation abroad without any implant failure. The average marginal bone loss (MBL) in the current report was 0.16 ± 0.167 mm at crown cementation, 0.275 ± 0.171 mm after 1 year, 0.265 ± 0.171 mm after 3 years, 0.213 ± 0.185 mm after 5 years, and 0.217 ± 0.194 mm at 10 years. CONCLUSION: The strategy of inserting and not removing the final abutment at the time of implant placement facilitates the establishment of adequate attachment of both soft and hard tissues to the abutment surface, ensuring uninterrupted organization of tissue architecture and offers advantages in helping maintain soft tissue maturation and preventing marginal bone level. CLINICAL SIGNIFICANCE: Immediately loaded implants in freshly extracted sockets lead to a significant reduction in marginal ridge resorption. The use of a temporary crown on a prefabricated abutment, exclusive of successive abutment manipulation, proved effective in preserving the primarily founding blood clot and served as a prototype for shaping the soft tissue around the previously wounded gum. How to cite this article: Berberi A, El Zoghbi A, Aad G, et al. Immediate Loading Using the Digitalized Customized Restoration of Single-tooth Implants Placed in Fresh Extraction Sockets in the Aesthetic Anterior Maxilla: A 10-Year Prospective Study of Marginal Bone Level. J Contemp Dent Pract 2024;25(3):213-220.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Implantes Dentales de Diente Único , Carga Inmediata del Implante Dental , Maxilar , Alveolo Dental , Humanos , Masculino , Femenino , Estudios Prospectivos , Maxilar/cirugía , Adulto , Carga Inmediata del Implante Dental/métodos , Alveolo Dental/cirugía , Pérdida de Hueso Alveolar , Pilares Dentales , Estética Dental , Extracción Dental , Prótesis Dental de Soporte Implantado , Diseño de Prótesis Dental , Diseño de Implante Dental-Pilar , Adulto Joven
9.
J Clin Periodontol ; 50(2): 158-169, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36217696

RESUMEN

AIM: The aim was to systematically evaluate the effect of low insertion torque values on the survival rate of immediately loaded dental implants. MATERIALS AND METHODS: The protocol was registered with PROSPERO (ID CRD42020189499). An electronic search was performed in PubMed, Embase, Web of Science, and Cochrane Central Register of Controlled Trials until June 2022 in English and Spanish. Studies analysing the failure or survival rate of immediately loaded dental implants according to different insertion torque values were included. RESULTS: Five-hundred seventy-three articles were assessed for eligibility, of which seven articles, four randomized clinical trials (RCTs), one controlled clinical trial, and two prospective case series studies were included in the qualitative analysis. The RCTs were classified as having low risk of bias and the non-RCTs as having moderate and serious risk of bias. The mean survival rate for implants with low insertion toque (≤35 Ncm) was 96% (p > .001, 95% confidence interval [CI]: 0.91-0.98) and that for implants with medium or high insertion torque (>35 Ncm) was 92% (p > .001, 95% CI: 0.86-0.96) (incidence rate ratio [IRR] = 1.05, 95% CI: 0.79-1.39, p = .175, I2  = 0.0%). Splinted implants with insertion torque >20 Ncm and single implants with insertion torque >35 Ncm had a higher survival rate than implants with lower insertion torque values (IRR = 1.05, 95% CI: 0.78-1.43, p = .956, I2  = 0.0%, and RR = 0.92, 95% CI: 0.48-1.75, p = .799, I2  = 0.0%, respectively). Different insertion torque values achieved equivalent outcomes. The mean follow-up was 24 months. CONCLUSIONS: Low insertion torque values have no significant effect on survival rates of immediate loading implants at a mean follow-up of 24 months.


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Implantación Dental Endoósea/métodos , Carga Inmediata del Implante Dental/métodos , Tasa de Supervivencia , Torque , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental
10.
Clin Oral Implants Res ; 34(4): 351-366, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36760035

RESUMEN

PURPOSE: To retrospectively assess clinical and radiographic outcomes of immediately loaded full-arch fixed prostheses supported by axial and tilted implants up to 15 years of function. MATERIALS AND METHODS: Patients with one completely edentulous arch received an immediate full-arch fixed prosthesis supported by two anterior axial and two posterior tilted implants. Definitive prosthesis consisting of a CAD-CAM titanium framework and acrylic teeth was delivered 6 months later. Patients were regularly followed to assess clinical parameters and marginal bone level (MBL) change. Multilevel regression analysis was performed to investigate factors affecting implant failure and MBL. RESULTS: Six hundred ninety-two implants were placed in 72 maxillae and 101 mandibles. Seven maxillary implants (5 axial and 2 tilted) in 6 patients and 12 mandibular implants (6 axial and 6 tilted) in 5 patients failed. 15-year cumulative implant survival was 97.51% and 96.91% in maxilla and mandible, respectively (p = .64). After 10 years, the difference in MBL between axial and tilted implants was not significant in the maxilla (p = .47, 65 patients), while it was in the mandible (p < .001, 80 patients). Significant higher bone loss was reported in the mandible at both 5- and 10-year follow-up (p < .001 and p = .004, respectively). Mixed-effect multilevel linear regression evidenced a correlation between arch and bone loss at 5- and 10-year follow-up, while no correlation was found with age, gender, smoking, diabetes, and history of periodontal disease. CONCLUSION: This long-term study suggests that the present technique can be considered a viable treatment modality for the immediate rehabilitation of both maxilla and mandible.


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Arcada Edéntula , Humanos , Estudios Retrospectivos , Estudios de Seguimiento , Diseño de Prótesis Dental , Arcada Edéntula/cirugía , Arcada Edéntula/rehabilitación , Prótesis Dental de Soporte Implantado , Carga Inmediata del Implante Dental/métodos , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Resultado del Tratamiento
11.
Clin Oral Investig ; 27(10): 5935-5946, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37612525

RESUMEN

OBJECTIVES: There is a scarcity of randomized clinical trials (RCT) that report medium- and long-term results and a lack of consensus in the literature on the predictability of immediately loaded unsplinted narrow diameter implants supporting mandibular overdentures. This RCT compared the performance of conventional (CL) and immediate loading (IL) of mandibular overdentures retained by two narrow-diameter implants for 3 years. MATERIALS AND METHODS: Patients from an RCT treated with CL or IL were invited to attend to 2- and 3-year follow-ups. Clinical, radiographic, functional, and oral health-related quality of life parameters were evaluated. Prosthetic maintenance events, biological complications, and success and survival rates were also recorded. The data were tested by multilevel mixed-effects linear regression analysis and chi-squared tests. RESULTS: The 1-year survival rates of 90% in the CL group and 85% in the IL group were maintained as no implants were lost between 1 and 3 years. The marginal bone loss (MBL) in the IL group was significantly lower after year 3 (-0.04; p < 0.01). Significant changes were found only for the intra-group comparisons in the third year of function: (i) CL and IL presented similar progression of implant stability, MBL, and posterior bone area resorption; (ii) while CL started deteriorating of masticatory function, IL still exhibited functional evolution and (iii) oral comfort domain in the CL and pain domain in the IL were improved. CONCLUSION: Although IL experienced the lowest MBL after 3 years, the outcomes showed that both loading protocols result in predictable medium-term rehabilitation when monitored annually. CLINICAL RELEVANCE: It can be expected that in the third year of function, patients with immediate loading may present more complaints related to general performance even with acceptable masticatory function and self-reported improvements in oral comfort.

12.
J Esthet Restor Dent ; 35(8): 1194-1204, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37449557

RESUMEN

OBJECTIVE: To report a novel digital workflow to replace an anterior maxillary tooth lost due to trauma with an implant multilayer restoration by using the patient's extracted tooth as a final crown restoration using computer-aided design/computer-aided manufacturing (CAD/CAM) technology. CLINICAL CONSIDERATIONS: Instead of using the patient's natural tooth as an immediate provisional restoration to achieve predictable results in terms of esthetics and soft tissue structure, a novel digital strategy was performed to obtain a natural final crown restoration by using the patient's tooth associated with a lithium disilicate customized implant abutment. CONCLUSIONS: The perspective of using this strategic approach for implant restorative dental treatments in patients with traumatic root fractures in the anterior region has great potential as it helps to maintain the emergence profile of the natural dentition and esthetics. CLINICAL SIGNIFICANCE: Optimal esthetic outcomes are challenging in implant dentistry regarding soft tissue structure and morphology factors. Using natural teeth from surgery to deliver the final restoration might be beneficial when an anterior tooth is lost due to trauma.


Asunto(s)
Estética Dental , Boca Edéntula , Humanos , Flujo de Trabajo , Diseño Asistido por Computadora , Coronas , Extracción Dental
13.
BMC Oral Health ; 23(1): 686, 2023 09 22.
Artículo en Inglés | MEDLINE | ID: mdl-37740190

RESUMEN

BACKGROUND: Dental implants emerge as a dependable and efficacious alternative for patients experiencing partial or complete tooth loss. The stability of these implants is influenced by surface topography and macro-level design. In cases where the height of the maxillary posterior region is diminished, employing short implants can prove advantageous. With the aim of examining the distribution of von Mises stress, strain, and micromovement in D4 bone quality surrounding platform-switched short implants, measuring 6 mm in length and featuring diameters ranging from 4 to 6 mm, as well as different thread designs, an in-depth finite element analysis was conducted under immediate loading conditions. METHODOLOGY: A 3D finite element model was constructed to simulate maxillary molar crowns, incorporating an implant with a length of 6 mm and varying diameters and thread designs. The diameters utilized were 4/3.6 mm, 5/4 mm, and 6/4.8 mm, while the thread designs included buttress, square, and triangle patterns. Each model underwent analysis with a 100 N force applied in two directions: vertical and oblique, relative to the long axis of the implant. Stress, strain, and micromovement in the peri-implant region were recorded, employing the Ansys Workbench R v.18.1 software for modelling and analysis. RESULTS: When comparing all three diameters, the wide diameter (6 mm threads) exhibited the lowest values of peri-implant von Mises stresses (3.3 MPa and 35.1 MPa), strains (194 Ɛ and 484 Ɛ), and micromovements (0.7 µm and 1.3 Ɛ) subjected to axial and non-axial loading of a 100 N force. Notably, square microthreads yielded the most favorable stress parameters among the different thread shapes, manifesting the minimum values of stress, strains, and micromovements in their vicinity. CONCLUSION: For the treatment of atrophic ridges or in scenarios necessitating extensive surgical preparation of the implant site, a combination of short implants, wide diameters, and platform switching can be employed. In situations with reduced bone height and the requirement for an implant-supported prosthesis to replace a missing permanent maxillary molar, the utilization of wide-diameter platform-switched short implants measuring 6 mm in length, featuring a square thread design, should be taken into consideration.


Asunto(s)
Implantes Dentales , Humanos , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Atrofia , Diente Molar
14.
Gen Dent ; 71(3): 40-45, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37083612

RESUMEN

The aim of this study was to evaluate changes in periodontal bacterial species during the transition from hopeless teeth to denture-supporting immediate implants. Biofilm and saliva samples were collected from 13 women and 7 men before the extraction of hopeless teeth with severe periodontitis (baseline) and 90 days after the placement of immediate implants that supported immediately loaded complete dentures (day 90). The levels of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, and Streptococcus oralis were analyzed by real-time polymerase chain reaction. Differences in the levels of bacterial species in the subgingival biofilm and saliva and between baseline and day 90 were evaluated by a 2-way analysis of variance followed by the Tukey test. There was a significant reduction in the levels of T forsythia from baseline to day 90 in saliva and subgingival biofilms (P < 0.05) and a tendency toward a reduction of the other bacterial species. The total bacterial load was higher in saliva than in subgingival biofilm at baseline and day 90 (P < 0.05), while the individual levels of all species were higher in the biofilm than in saliva at both times (P < 0.05). The results showed an overall reduction in the levels of pathogenic bacterial species, particularly T forsythia, during the transition from hopeless dentition to implant-supported dentures. The subgingival biofilm harbored considerable levels of pathogenic species, suggesting that implant placement immediately after extraction of teeth with severe periodontitis may induce changes that favor colonization by pathogenic microorganisms.


Asunto(s)
Dentición , Periodontitis , Masculino , Humanos , Femenino , Porphyromonas gingivalis , Carga Bacteriana
15.
Med J Armed Forces India ; 79(Suppl 1): S365-S375, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38144623

RESUMEN

With the increasing life expectancy and improved quality of life, the conventional prosthodontic removable treatment modalities are being replaced with implant retained fixed prostheses. A full-arch conventional rehabilitation of edentulous ridges requires six to ten dental implants. However, some patients demand fixed implant-supported prostheses inspite of medical conditions and economic concerns. Also in completely edentulous cases, the insufficient bone morphology directs the treatment plan towards alternatives such as cantilever prostheses, short implants or ridge augmentation procedures. These clinical conditions have brought in a quantum shift in treatment planning towards the 'all on 4 protocol' providing immediately loaded fixed prosthesis supported by 4 implants thereby providing optimum and immediate restoration of function and esthetics.

16.
Niger J Clin Pract ; 26(9): 1215-1225, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37794532

RESUMEN

Dental implants are considered an ideal treatment for a missing single tooth. Immediate loading of implants can hasten the procedure, providing comfort to the patients. Recently, immediate loading of implants has gained much importance as it helps hasten the procedure and provides more comfort to patients. A previous systematic review published 5 years ago compared the success rates between immediate and conventional loading. There are several factors that influence the success rate of implants that were not discussed in detail in the previous review. Hence, the present systematic review is done to report differences in the outcomes from single implant restorations of missing teeth in the posterior region in patients who were subjected to immediate loading and conventional loading. A follow up for 1 year was done. Electronic databases of Medline, Scopus, and Web of Science were searched for publications in the English Language during May 2021. The search results yielded 306 articles, out of which 225 were excluded based on title and abstract screening. Screening of the remaining 81 full text articles yielded 14 original research articles that satisfied the predefined inclusion criteria. Meta analysis was not possible due to the heterogeneity of the data. The overall success rate of the immediate loading of a single implant is 94.31%. Implants in the maxillary region had a higher survival rate than those in the mandibular region. The age range between 18 and 80 years showed good prognosis and outcomes in older individuals. Good oral hygiene was emphasized for all patients to prevent any secondary conditions or delays in healing.


Asunto(s)
Anodoncia , Implantes Dentales , Carga Inmediata del Implante Dental , Pérdida de Diente , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Adulto Joven , Prótesis Dental de Soporte Implantado , Carga Inmediata del Implante Dental/métodos , Pérdida de Diente/cirugía
17.
J Evid Based Dent Pract ; 23(3): 101891, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37689447

RESUMEN

OBJECTIVES: Aim was to assess whether immediate loading (IL) is more effective than delayed loading (DL) for 2-implant bar-retained mandibular overdentures in terms of oral health-related quality of life (OHRQoL) improvement over a period of 24-month. METHODS: In this randomized controlled trial, 32 edentulous patients (mean age: 65.7 ± 10.6 years, 50.0% female) were included. Potential participants had to be unsatisfied with the retention of their current mandibular complete denture and demanded implant treatment for inclusion in the study. OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP) at baseline before treatment and 1, 3, 6, 12, and 24 months after implant loading and insertion of implant-retained bars for overdenture support. A mixed-effects model with patients as random effect and an unstructured covariance matrix was developed to address repeated outcome measurement. RESULTS: Patients' OHRQoL impairment at baseline was substantial indicated by mean OHIP summary score of 45.1 points. OHIP summary scores decreased substantially from baseline to 1-month follow-up to a mean of 33.5 points (P = .020). OHRQoL further improved during study period indicated by OHIP summary score of 25.7 points at 24-month follow-up. Raw treatment effects (IL vs. DL) ranged from -1.2 OHIP points for 12-month follow-up to 5.8 OHIP points for 24-month follow-up. Assuming constant treatment and time effects, treatment effect was small and not statistically significant (-0.7 OHIP points; P= .918). CONCLUSION: A 2-implant bar-retained mandibular overdentures substantially improves OHRQoL over a period of at least 24 months. There seems to be no significant effect of implant loading protocol.


Asunto(s)
Prótesis de Recubrimiento , Calidad de Vida , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Mandíbula , Ensayos Clínicos Controlados Aleatorios como Asunto
18.
Stomatologiia (Mosk) ; 102(6): 22-27, 2023.
Artículo en Ruso | MEDLINE | ID: mdl-37997309

RESUMEN

OBJECTIVE: To study the effectiveness of implant-supported full-arch metal-ceramic prosthesis with gold-platinum alloy framework in elderly patients. MATERIALS AND METHODS: The study included patients with complete and/or partial loss of teeth and terminal dentition. In 2007-2008, 354 implants were inserted in 27 patients. The age of the patients was 61.31±5.08 years. Mombelli index criteria (mBI [modified Sulcus Bleeding Index]) were used. The plaque index was determined using a modified Löe & Silness method. The state of the peri-implant bone (ΔMBL) was determined by a series of OPG. The Geriatric Oral Health Index (GOHAI) was used to assess oral health in the elderly. RESULTS: Metal-ceramic full-arch implant prostheses with a gold-platinum alloy framework, based on a sufficient and optimal number of implants (6-8), showed high survival rate (100%) after 15 years. Marginal bone loss (ΔMBL) after 15 years was -1.44±1.27 mm. The survival rate of implants was 99.4%. Scores on the GOHAI scale were higher in patients after orthopedic rehabilitation (from 52.7±7.1 to 54.1±8.4, p<0.001). CONCLUSION: After 15 years, all prostheses had mechanical defects, which at the same time allowed them to be used without restrictions. Screw fixation of full-arch implant prostheses, although it was associated with mechanical complications, nevertheless made it possible to perform surgical interventions in a timely manner and stop the development of inflammatory complications. Thus, we do not see any grounds for removing metal-ceramic prostheses and replacing them with new implant prostheses even after a 15-year period of operation. At the same time, it is necessary to take into account the reduction in the possibility of individual oral hygiene in elderly patients, as well as possible restrictions on self-visiting a dentist or dental hygienist.


Asunto(s)
Implantes Dentales , Platino (Metal) , Humanos , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Estudios de Cohortes , Estudios Prospectivos , Cerámica , Mandíbula/cirugía , Aleaciones , Oro , Prótesis Dental de Soporte Implantado , Estudios de Seguimiento , Fracaso de la Restauración Dental
19.
Clin Oral Implants Res ; 33(5): 501-510, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35213758

RESUMEN

OBJECTIVES: Immediate implant placement and loading is a practice that continues to gain traction in implant dentistry because it reduces treatment time and improves satisfaction. Novel implant designs that facilitate increased primary stability, while not compromising osseointegration and long-term survival are important to offer immediate solutions for missing teeth. Here, we hypothesize that fully tapered implants can obtain successful osseointegration with high survival rates after immediate loading in fresh extraction sockets and healed sites. MATERIALS AND METHODS: A total of 13 swine with 73 implants were evaluated. Fully tapered or apically tapered implants were placed in extraction sockets and healed sites. Insertion torque and resonance frequency analysis were determined at placement and euthanasia. Animals were evaluated at: placement, and 1-week and 12-weeks after placement. Bone to Implant Contact (BIC), Bone Area/Total Area (BA/TA), and first BIC (fBIC) analyses were conducted. RESULTS: The fully tapered implant achieved similar primary stability with lower insertion torque at placement. Apically and fully tapered implants had comparable BIC (50.1% vs 59.4%) and ISQ (82.5 vs 80.3) values by 12 weeks in healed sites. In extraction sockets, BIC and ISQ for the apically tapered implant was 35.8% and 73.2 and 37.8% and 79.2 for the fully tapered implants, respectively. CONCLUSIONS: In this short-term study, immediately loaded fully tapered implants obtained high survival with similar osseointegration ability as apically tapered implants when placed in healed sites and fresh extraction sockets. Fully tapered implants show promise for use in immediate loading and immediate placement.


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Proceso Alveolar/cirugía , Animales , Implantación Dental Endoósea , Oseointegración , Porcinos , Extracción Dental , Alveolo Dental/cirugía , Torque
20.
Clin Oral Implants Res ; 33(1): 120-129, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34676916

RESUMEN

OBJECTIVES: To test the null hypothesis that vertical peri-implant bone level alterations (ΔIBL) are equivalent in immediately (IL) and 3-month post-placement (DL) loaded implants in mandibular implant overdentures (IODs) on two implants. MATERIALS AND METHODS: Thirty-two patients receiving two interforaminal implants, one with a platform-switched and one with a platform-matching abutment were randomly assigned to the IL or DL group (allocation ratio 1:1). All implants were primarily splinted with chairside-customized bars, converting the existing removable complete dentures to IODs. Standardized radiographs were recorded. The influence of the loading protocol (IL vs. DL), implant platform (platform switched vs. platform matching), implant site (43 vs. 33), participant age (≤65 vs. >65 years), and definition of baseline (implant placement vs. implant loading) were analyzed, applying linear regression analyses (α = 0.05). The equivalence range was [-0.4; 0.4]. RESULTS: Three participants of the IL group were lost during follow-up. The overall mean ΔIBL was -0.96 ± 0.89 mm. The ΔIBL was equivalent in terms of the implant platform and implant site but not in terms of participant age (in favor of more elderly participants) and the loading protocol. A significantly smaller ΔIBL was observed in the IL when the baseline was considered to be implant placement (p = .017), but not when it was considered to be implant loading (p = .084). CONCLUSION: Immediate loading of primary-splinted implants in two-implant bar-retained overdentures, seems beneficial relative to loading 3 months post-placement, with respect to ΔIBL. The ΔIBL were equivalent in terms of platform switching.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Carga Inmediata del Implante Dental , Anciano , Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Estudios de Seguimiento , Humanos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA