Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 369
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Skin Res Technol ; 30(6): e13764, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38853456

RESUMEN

Injectable fillers, pivotal in aesthetic medicine, have evolved significantly with recent trends favoring biostimulators like calcium hydroxylapatite (CaHA-CMC; Radiesse, Merz Aesthetics, Raleigh, NC) and poly-l-lactic acid (PLLA; Sculptra Aesthetics, Galderma, Dallas, TX). This study aims to compare the particle morphology of these two injectables and examine its potential clinical implications. Utilizing advanced light and scanning electron microscopy techniques, the physical characteristics of CaHA-CMC and PLLA particles were analyzed, including shape, size, circularity, roundness, aspect ratio, and quantity of phagocytosable particles. The findings reveal several morphological contrasts: CaHA-CMC particles exhibited a smooth, homogenous, spherical morphology with diameters predominantly ranging between 20 and 45 µm, while PLLA particles varied considerably in shape and size, appearing as micro flakes ranging from 2 to 150 µm in major axis length. The circularity and roundness of CaHA-CMC particles were significantly higher compared to PLLA, indicating a more uniform shape. Aspect ratio analysis further underscored these differences, with CaHA-CMC particles showing a closer resemblance to circles, unlike the more oblong PLLA particles. Quantification of the phagocytosable content of both injectables revealed a higher percentage of phagocytosable particles in PLLA. These morphological distinctions may influence the tissue response to each treatment. CaHA-CMC's uniform, spherical particles may result in reduced inflammatory cell recruitment, whereas PLLA's heterogeneous particle morphology may evoke a more pronounced inflammatory response.


Asunto(s)
Rellenos Dérmicos , Durapatita , Poliésteres , Durapatita/química , Poliésteres/química , Rellenos Dérmicos/química , Rellenos Dérmicos/administración & dosificación , Humanos , Técnicas Cosméticas , Tamaño de la Partícula , Materiales Biocompatibles/química , Microscopía Electrónica de Rastreo
2.
Aesthetic Plast Surg ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902341

RESUMEN

OBJECTIVES: With the increasing global clinical application of regenerative injection materials, there is a growing recognition of the crucial role played by poly-L-lactic acid (PLLA). The aim of this study is to conduct a systematic review on the therapeutic efficacy and safety of PLLA in clinical applications for facial treatments. METHODS: We conducted a search of the PubMed, EMBASE, Web of Science, and Wanfang databases, followed by screening of the retrieved articles based on predefined inclusion and exclusion criteria. We then performed an analysis on the final set of included articles that met our inclusion criteria. Within these included articles, quality assessment for randomized controlled trials (RCTs) was carried out using the Jadad scale, while non-randomized controlled trials (non-RCTs) were evaluated using the MINORS scale. RESULTS: Our search of above database, using the relevant search terms, yielded a total of 1300 PLLA-related articles. After applying the inclusion and exclusion criteria, 1280 articles were excluded. Only 20 articles, 16 in English and 4 in Chinese, were included in our final analysis, among them 16 NRCTs and 4 RCTs. According to the different clinical evaluation standards, the treatment of PLLA has achieved good outcomes. Most PLLA injection-related adverse events are mild and self-limited, without any additional treatment requirement. CONCLUSION: PLLA is a reasonably safe and effective facial injection material that can be applied in different facial injection areas and depth using various reconstitute and injection methods. LEVEL OF EVIDENCE I: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

3.
Molecules ; 29(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38731542

RESUMEN

Bilayer electrospun fibers aimed to be used for skin tissue engineering applications were fabricated for enhanced cell attachment and proliferation. Different ratios of PHBV-PLLA (70:30, 80:20, and 90:10 w/w) blends were electrospun on previously formed electrospun PHBV membranes to produce their bilayers. The fabricated electrospun membranes were characterized with FTIR, which conformed to the characteristic peaks assigned for both PHBV and PLLA. The surface morphology was evaluated using SEM analysis that showed random fibers with porous morphology. The fiber diameter and pore size were measured in the range of 0.7 ± 0.1 µm and 1.9 ± 0.2 µm, respectively. The tensile properties of the bilayers were determined using an electrodynamic testing system. Bilayers had higher elongation at break (44.45%) compared to the monolayers (28.41%) and improved ultimate tensile strength (7.940 MPa) compared to the PHBV monolayer (2.450 MPa). In vitro cytotoxicity of each of the scaffolds was determined via culturing MC3T3 (pre-osteoblastic cell line) on the membranes. Proliferation was evaluated using the Alamar Blue assay on days 3, 7, and 14, respectively. SEM images of cells cultured on membranes were taken in addition to bright field imaging to visually show cell attachment. Fluorescent nuclear staining performed with DAPI was imaged with an inverted fluorescent microscope. The fabricated bilayer shows high mechanical strength as well as biocompatibility with good cell proliferation and cell attachment, showing potential for skin substitute applications.


Asunto(s)
Materiales Biocompatibles , Proliferación Celular , Poliésteres , Piel , Ingeniería de Tejidos , Andamios del Tejido , Ingeniería de Tejidos/métodos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Poliésteres/química , Animales , Ratones , Proliferación Celular/efectos de los fármacos , Andamios del Tejido/química , Resistencia a la Tracción , Membranas Artificiales , Línea Celular , Ensayo de Materiales , Polímeros/química , Adhesión Celular/efectos de los fármacos
4.
Molecules ; 29(5)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38474593

RESUMEN

Lycorine is a kind of natural active ingredient with a strong antitumor effect. In this study, folate ligand-conjugated polyethylene glycol-block-poly(l-lactide) (PEG-PLLA) nanoparticles (FA-PEG-PLLA NPs) were designed to deliver lycorine to enhance its anti-glioma activity. The successful preparation of the FA-PEG-PLLA polymer was confirmed by 1H-NMR, FT-IR, XRD, TGA, and DSC. The optimal formulation for LYC@FA-PEG-PLLA NPs was determined by response surface analysis as follows: sodium dodecyl sulfate (SDS) of 1%, carrier material of 0.03 g, organic phase volume of 3 mL, and ultrasonic power of 20%. The LYC@FA-PEG-PLLA NPs exhibited an encapsulation efficiency of 83.58% and a particle size of 49.71 nm, demonstrating good stability. Hemolysis experiments, MTT assays, and cell scratch assays revealed excellent biocompatibility of FA-PEG-PLLA and superior anti-glioma activity of LYC@FA-PEG-PLLA NPs compared to the raw drug. Additionally, cell apoptosis assays, ROS experiments, and western blot analysis demonstrated that LYC@FA-PEG-PLLA NPs contributed to cell apoptosis by inducing ROS generation and increasing the expression of NF-κB inhibitory protein IκBα. These results suggested that LYC@FA-PEG-PLLA NPs hold promise for glioma treatment.


Asunto(s)
Alcaloides de Amaryllidaceae , Glioma , Nanopartículas , Fenantridinas , Humanos , Ácido Fólico/química , Especies Reactivas de Oxígeno , Espectroscopía Infrarroja por Transformada de Fourier , Nanopartículas/química , Polietilenglicoles/química , Portadores de Fármacos/química , Tamaño de la Partícula , Línea Celular Tumoral
5.
Macromol Rapid Commun ; 44(7): e2200868, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36755508

RESUMEN

The development of bio-based polymer materials, such as polylactic acid (PLA) -based polymers, is an effective strategy to reduce dependence on petrochemical-based polymers. However, the preparation of bio-based polymers with high barrier properties is a major challenge. To overcome this challenge, a nacreous layer structure with a ' brick and mud ' pattern is mimicked to improve the overall performance of the material. In this paper, Poly (L -lactic acid) (PLLA) and Polypropylene Glycol (PPG) was combined to prepare bio-based polyurethane (PU-PLLA), which is used as the slurry structure of nacreous layer. The bio-based biomimetic composite membrane (PU-PLLA/BN) is then obtained by adding boron nitride (BN, brick structure of pearl layer) to it. The water vapor permeability test results show that the permeability of PU-PLLA material can be reduced by more than 50% by 5 wt.% BN, which is because the addition of BN can increase the length and tortuosity of the gas molecular diffusion path in the composite. Therefore, this pearl-inspired PU-PLLA/BN film has excellent moisture resistance, which opens up a broad road for the practical application of PLLA in flexible laminated packaging.


Asunto(s)
Poliésteres , Polímeros , Poliésteres/química , Polímeros/química , Embalaje de Productos , Permeabilidad
6.
Proc Natl Acad Sci U S A ; 117(46): 28655-28666, 2020 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-33144508

RESUMEN

The gold standard treatment for anterior cruciate ligament (ACL) reconstruction is the use of tendon autografts and allografts. Limiting factors for this treatment include donor site morbidity, potential disease transmission, and variable graft quality. To address these limitations, we previously developed an off-the-shelf alternative, a poly(l-lactic) acid (PLLA) bioengineered ACL matrix, and demonstrated its feasibility to regenerate ACL tissue. This study aims to 1) accelerate the rate of regeneration using the bioengineered ACL matrix by supplementation with bone marrow aspirate concentrate (BMAC) and growth factors (BMP-2, FGF-2, and FGF-8) and 2) increase matrix strength retention. Histological evaluation showed robust tissue regeneration in all groups. The presence of cuboidal cells reminiscent of ACL fibroblasts and chondrocytes surrounded by an extracellular matrix rich in anionic macromolecules was up-regulated in the BMAC group. This was not observed in previous studies and is indicative of enhanced regeneration. Additionally, intraarticular treatment with FGF-2 and FGF-8 was found to suppress joint inflammation. To increase matrix strength retention, we incorporated nondegradable fibers, polyethylene terephthalate (PET), into the PLLA bioengineered ACL matrix to fabricate a "tiger graft." The tiger graft demonstrated the greatest peak loads among the experimental groups and the highest to date in a rabbit model. Moreover, the tiger graft showed superior osteointegration, making it an ideal bioengineered ACL matrix. The results of this study illustrate the beneficial effect bioactive factors and PET incorporation have on ACL regeneration and signal a promising step toward the clinical translation of a functional bioengineered ACL matrix.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Regeneración Tisular Dirigida , Péptidos y Proteínas de Señalización Intercelular/uso terapéutico , Regeneración/efectos de los fármacos , Trasplante de Células Madre/métodos , Andamios del Tejido , Animales , Bioingeniería , Péptidos y Proteínas de Señalización Intercelular/farmacología , Oseointegración , Poliésteres , Tereftalatos Polietilenos , Conejos
7.
Proc Natl Acad Sci U S A ; 117(1): 214-220, 2020 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-31871178

RESUMEN

Piezoelectric materials, a type of "smart" material that generates electricity while deforming and vice versa, have been used extensively for many important implantable medical devices such as sensors, transducers, and actuators. However, commonly utilized piezoelectric materials are either toxic or nondegradable. Thus, implanted devices employing these materials raise a significant concern in terms of safety issues and often require an invasive removal surgery, which can damage directly interfaced tissues/organs. Here, we present a strategy for materials processing, device assembly, and electronic integration to 1) create biodegradable and biocompatible piezoelectric PLLA [poly(l-lactic acid)] nanofibers with a highly controllable, efficient, and stable piezoelectric performance, and 2) demonstrate device applications of this nanomaterial, including a highly sensitive biodegradable pressure sensor for monitoring vital physiological pressures and a biodegradable ultrasonic transducer for blood-brain barrier opening that can be used to facilitate the delivery of drugs into the brain. These significant applications, which have not been achieved so far by conventional piezoelectric materials and bulk piezoelectric PLLA, demonstrate the PLLA nanofibers as a powerful material platform that offers a profound impact on various medical fields including drug delivery, tissue engineering, and implanted medical devices.


Asunto(s)
Implantes Absorbibles , Sistemas Microelectromecánicos/instrumentación , Nanofibras/química , Transductores , Sistemas de Liberación de Medicamentos , Electricidad , Electrónica , Diseño de Equipo , Monitoreo Fisiológico/instrumentación , Presión , Prótesis e Implantes , Ingeniería de Tejidos , Ultrasonido
8.
BMC Musculoskelet Disord ; 24(1): 151, 2023 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-36849968

RESUMEN

BACKGROUND: 3D printing technology has become a research hotspot in the field of scientific research because of its personalized customization, maneuverability and the ability to achieve multiple material fabrications. The focus of this study is to use 3D printing technology to customize personalized poly L-lactic acid (PLLA) porous screws in orthopedic plants and to explore its effect on tendon-bone healing after anterior cruciate ligament (ACL) reconstruction. METHODS: Preparation of PLLA porous screws with good orthogonal pore structure by 3D printer. The hydroxyapatite (HA) was adsorbed on porous screws by electrostatic layer-by-layer self-assembly (ELSA) technology, and PLLA-HA porous screws were prepared. The surface and spatial morphology of the modified screws were observed by scanning electron microscopy (SEM). The porosity of porous screw was measured by liquid displacement method. Thirty New Zealand male white rabbits were divided into two groups according to simple randomization. Autologous tendon was used for right ACL reconstruction, and porous screws were inserted into the femoral tunnel to fix the transplanted tendon. PLLA group was fixed with porous screws, PLLA-HA group was fixed with HA modified porous screws. At 6 weeks and 12 weeks after surgery, 5 animals in each group were sacrificed randomly for histological examination. The remaining 5 animals in each group underwent Micro-CT and biomechanical tests. RESULTS: The pores of PLLA porous screws prepared by 3D printer were uniformly distributed and connected with each other, which meet the experimental requirements. HA was evenly distributed in the porous screw by ELSA technique. Histology showed that compared with PLLA group, mature bone trabeculae were integrated with grafted tendons in PLLA-HA group. Micro-CT showed that the bone formation index of PLLA-HA group was better than that of PLLA group. The new bone was uniformly distributed in the bone tunnel along the screw channel. Biomechanical experiments showed that the failure load and stiffness of PLLA-HA group were significantly higher than those of PLLA group. CONCLUSIONS: The 3D printed PLLA porous screw modified by HA can not only fix the grafted tendons, but also increase the inductivity of bone, promote bone growth in the bone tunnel and promote bone integration at the tendon-bone interface. The PLLA-HA porous screw is likely to be used in clinic in the future.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Animales , Conejos , Ligamento Cruzado Anterior/cirugía , Tornillos Óseos , Durapatita , Articulación de la Rodilla , Ácido Láctico , Porosidad
9.
Small ; 18(36): e2201656, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35419952

RESUMEN

Bone defect regeneration depends on the population and lifespan of M2 macrophages, which are regulated by dual signals generated by the "physical" spatial configuration of biological tissues and "molecular" chemokines. Herein, inspired by the reprogramming of macrophages, immunoengineered porous microspheres are constructed to accelerate bone repair through the regulation of both "physical" and "molecular" signals. The porous structure of injectable poly (l-lactic acid) (PLLA) microspheres prepared by the microfluidic technique provides a "physical signal" for osteogenic differentiation. Additionally, interleukin (IL)-4-loaded liposomes (Ls) are modified on PLLA microspheres through amide bonds to produce IL-4/Ls/PLLA microspheres, providing a "molecular signal" in stimulating the differentiation of macrophages to M2 type. It is confirmed that IL-4/Ls/PLLA microspheres could induce M2-macrophages polarization and potentiate osteoblast proliferation and differentiation while coculturing with macrophages and osteoblasts in vitro. Besides, IL-4/Ls/PLLA microspheres are proved to promote bone defect regeneration by inducing the conversion of M1 macrophages to M2 through dual biosignal-functional regulation in both the calvaria defect and maxillary sinus defect models. Overall, the immuno-reprogrammed IL-4/Ls/PLLA microspheres achieve the precise immuno-reprogramming of macrophages by dual biosignal-functional regulation. This immune reengineering strategy paves a way for clinical bone defect treatment.


Asunto(s)
Interleucina-4 , Osteogénesis , Regeneración Ósea/fisiología , Microesferas , Osteoblastos , Poliésteres/química
10.
Neurochem Res ; 47(7): 1991-2001, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35359243

RESUMEN

The field of tissue engineering exploits living cells in a variety of ways to restore, maintain, or enhance tissues and organs. Between stem cells, human induced pluripotent stem cells (hiPSCs), are very important due to their wide abilities. Growth factors can support proliferation, differentiation, and migration of hiPSCs. Platelet-rich plasma (PRP) could be used as the source of growth factors for hiPSCs. In the present study, proliferation and neural differentiation of hiPSCs on surface-modified nanofibrous Poly-L-lactic acid (PLLA) coated with platelet-rich plasma was investigated. The results of in vitro analysis showed that on the surface, which was modified nanofibrous scaffolds coated with platelet-rich plasma, significantly enhanced hiPSCs proliferation and neural differentiation were observed. Whereas the MTT ([3-(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyltetrazolium Bromide]) results showed biocompatibility of surface-modified nanofibrous scaffolds coated with platelet-rich plasma and the usage of these modified nanoscaffolds in neural tissue engineering in vivo is promising for the future.


Asunto(s)
Células Madre Pluripotentes Inducidas , Nanofibras , Plasma Rico en Plaquetas , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Humanos , Ingeniería de Tejidos/métodos , Andamios del Tejido
11.
Macromol Rapid Commun ; 43(11): e2200148, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35343619

RESUMEN

The bulk enthalpy of melting of α-crystals of poly (L-lactic acid) (PLLA) is evaluated by fast scanning calorimetry (FSC), by correlating the melting enthalpy of samples of different crystallinity with the corresponding heat capacity at 90 °C, that is at a temperature higher than the glass transition temperature of the bulk amorphous phase and lower than the melting temperature. Extrapolation of this relationship for crystals formed at 140 °C towards the heat capacity of fully solid PLLA yields a value of 104.5±6 J g-1 when melting occurs at 180-200 °C. The analysis relies on a two-phase structure, that is, absence of a vitrified rigid amorphous fraction (RAF) at the temperature of analysis the solid fraction (90 °C). Formation and vitrification of an RAF are suppressed by avoiding continuation of primary crystallization and secondary crystallization during cooling the system from the crystallization temperature of 140 °C to 90 °C, making use of the high cooling capacity of FSC. Small-angle X-ray scattering (SAXS) confirmed thickening of initially grown lamellae which only is possible if these lamellae are not surrounded by a glassy RAF. Linear crystallinity values obtained by SAXS and calorimetrically determined enthalpy-based crystallinities agree close to each other.


Asunto(s)
Ácido Láctico , Calorimetría , Rastreo Diferencial de Calorimetría , Ácido Láctico/química , Dispersión del Ángulo Pequeño , Difracción de Rayos X
12.
Int J Mol Sci ; 23(4)2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-35216156

RESUMEN

Male pediatric survivors of cancers and bone marrow transplantation often require adjuvant chemoradiation therapy that may be gonadotoxic. The optimal methods to preserve fertility in these prepubertal males are still under investigation. This manuscript presents an in vivo experiment which involved transplantation of immature testicular tissues (ITT) from transgenic donor, to wild-type recipient mice. Donors and recipients were age-mismatched (from 20-week-old donors to 3-week-old recipients, and vice versa) and the transplantation sites involved the abdomen, skin of the head, back muscle, and scrotum. The application of poly-l-lactic acid (PLLA) scaffold was also evaluated in age-matched donors and recipients (both 3-weeks-old). To quantitively evaluate the process of spermatogenesis after ITT transplantation and scaffold application, bioluminescence imaging (BLI) was employed. Our result showed that ITT from 3-week-old mice had the best potential for spermatogenesis, and the optimal transplantation site was in the scrotum. Spermatogenesis was observed in recipient mice up to 51 days after transplantation, and up to the 85th day if scaffold was used. The peak of spermatogenesis occurred between the 42nd and 55th days in the scaffold group. This animal model may serve as a framework for further studies in prepubertal male fertility preservation.


Asunto(s)
Preservación de la Fertilidad/métodos , Infertilidad Masculina/terapia , Espermatogénesis , Testículo/citología , Ingeniería de Tejidos/métodos , Animales , Infertilidad Masculina/etiología , Masculino , Ratones , Poliésteres/química , Traumatismos Experimentales por Radiación/complicaciones , Testículo/crecimiento & desarrollo , Testículo/fisiología , Andamios del Tejido/química
13.
Int J Mol Sci ; 23(20)2022 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-36293000

RESUMEN

Prepubertal boys with cancer may suffer from reduced fertility and maturity following gonadotoxic chemoradiotherapy. Thus, a viable method of immature testicular tissue (ITT) preservation is required in this cohort. In this study, we used poly-L-lactic acid electrospun scaffolds with two levels of fineness to support the development of ITT transplanted from transgenic donors to wild-type recipient mice. The purpose of this study was to evaluate the potential of ITT transplantation and spermatogenesis after using the two scaffolds, employing bioluminescence imaging for evaluation. The results suggest that ITT from 4-week-old mice possessed the most potential in spermatogenesis on the 70th day, together with the fine electrospun scaffolds. Moreover, bioluminescent imaging intensity was observed in recipient mice for up to 107 days, approximately six times more than the coarse electrospun scaffold and the control group. This occurs since the fine scaffold is more akin to the microenvironment of native testicular tissue as it reduces stiffness resulting from micronization and body fluid infiltration. The thermal analysis also exhibited recrystallization during the biodegradation process, which can lead to a more stable microenvironment. Overall, these findings present the prospect of fertility preservation in prepubertal males and could serve as a framework for future applications.


Asunto(s)
Preservación de la Fertilidad , Masculino , Ratones , Animales , Preservación de la Fertilidad/métodos , Ratones Transgénicos , Testículo/metabolismo , Espermatogénesis , Ingeniería de Tejidos , Modelos Animales de Enfermedad , Criopreservación
14.
Molecules ; 27(21)2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36364463

RESUMEN

PLLA, PCL and PHBV are aliphatic polyesters which have been researched and used in a wide range of medical devices, and all three have advantages and disadvantages for specific applications. Blending of these materials is an attractive way to make a material which overcomes the limitations of the individual polymers. Both PCL and PHBV have been evaluated in polymer blends with PLLA in order to provide enhanced properties for specific applications. This paper explores the use of PCL and PHBV together with PLLA in ternary blends with assessment of the thermal, mechanical and processing properties of the resultant polymer blends, with the aim of producing new biomaterials for orthopaedic applications. DSC characterisation is used to demonstrate that the materials can be effectively blended. Blending PCL and PHBV in concentrations of 5-10% with PLLA produces materials with average modulus improved by up to 25%, average strength improved by up to 50% and average elongation at break improved by 4000%, depending on the concentrations of each polymer used. PHBV impacts most on the modulus and strength of the blends, whilst PCL has a greater impact on creep behaviour and viscosity. Blending PCL and PHBV with PLLA offers an effective approach to the development of new polyester-based biomaterials with combinations of mechanical properties which cannot be provided by any of the materials individually.


Asunto(s)
Poliésteres , Polímeros , Materiales Biocompatibles , Viscosidad
15.
Molecules ; 27(12)2022 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-35744916

RESUMEN

Textile scaffolds that are either 2D or 3D with tunable shapes and pore sizes can be made through textile processing (weaving, knitting, braiding, nonwovens) using microfilaments. However, these filaments lack nano-topographical features to improve bone cell adhesion and proliferation. Moreover, the diameter of such filaments should be higher than that used for classical textiles (10−30 µm) to enable adhesion and the efficient spreading of the osteoblast cell (>30 µm diameter). We report, for the first time, the fabrication of biodegradable nanostructured cylindrical PLLA (poly-L-Lactic acid) microfilaments of diameters 100 µm and 230 µm, using a single step melt-spinning process for straightforward integration of nano-scale ridge-like structures oriented in the fiber length direction. Appropriate drawing speed and temperature used during the filament spinning allowed for the creation of instabilities giving rise to nanofibrillar ridges, as observed by AFM (Atomic Force Microscopy). These micro-filaments were hydrophobic, and had reduced crystallinity and mechanical strength, but could still be processed into 2D/3D textile scaffolds of various shapes. Biological tests carried out on the woven scaffolds made from these nano-structured micro filaments showed excellent human bone cell MG 63 adhesion and proliferation, better than on smooth 30 µm- diameter fibers. Elongated filopodia of the osteoblast, intimately anchored to the nano-structured filaments, was observed. The filaments also induced in vitro osteogenic expression, as shown by the expression of osteocalcin and bone sialoprotein after 21 days of culture. This work deals with the fabrication of a new generation of nano-structured micro-filament for use as scaffolds of different shapes suited for bone cell engineering.


Asunto(s)
Ingeniería de Tejidos , Andamios del Tejido , Adhesión Celular , Proliferación Celular , Humanos , Poliésteres/farmacología , Textiles , Andamios del Tejido/química
16.
Molecules ; 27(4)2022 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-35209205

RESUMEN

Cochlear implants, like other active implants, rely on precise and effective electrical stimulation of the target tissue but become encapsulated by different amounts of fibrous tissue. The current study aimed at the development of a dual drug release from a PLLA coating and from the bulk material to address short-term and long-lasting release of anti-inflammatory drugs. Inner-ear cytocompatibility of drugs was studied in vitro. A PLLA coating (containing diclofenac) of medical-grade silicone (containing 5% dexamethasone) was developed and release profiles were determined. The influence of different coating thicknesses (2.5, 5 and 10 µm) and loadings (10% and 20% diclofenac) on impedances of electrical contacts were measured with and without pulsatile electrical stimulation. Diclofenac can be applied to the inner ear at concentrations of or below 4 × 10-5 mol/L. Release of dexamethasone from the silicone is diminished by surface coating but not blocked. Addition of 20% diclofenac enhances the dexamethasone release again. All PLLA coatings serve as insulator. This can be overcome by using removable masking on the contacts during the coating process. Dual drug release with different kinetics can be realized by adding drug-loaded coatings to drug-loaded silicone arrays without compromising electrical stimulation.


Asunto(s)
Antiinflamatorios , Materiales Biocompatibles Revestidos/química , Implantes Cocleares , Dexametasona , Diclofenaco , Sistemas de Liberación de Medicamentos , Animales , Antiinflamatorios/química , Antiinflamatorios/farmacocinética , Dexametasona/química , Dexametasona/farmacocinética , Diclofenaco/química , Diclofenaco/farmacocinética , Liberación de Fármacos , Ratas , Ratas Sprague-Dawley
17.
Bull Exp Biol Med ; 174(1): 99-103, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36437338

RESUMEN

We studied the features of hydrolytic degradation of polylactic acid (PLLA) implants depending on their structural filling with hydroxyapatite (HA). The resistance to in vitro hydrolysis was tested for the following samples: PLLA without HA (control; group 1), PLLA/HA 25 wt% (group 2), and PLLA/HA 50 wt% (group 3). Samples were incubated at 37°C. In the hydrolysate, lactate, calcium ions, and inorganic phosphate were determined. Additionally, the time of appearance of visual deformation and sample disintegration was recorded. PLLA degradation was higher in samples saturated with HA. The highest resistance to deformation was noted for samples without HA. Samples with a PLLA/HA 50 wt% demonstrated the maximum degradation of PLLA in combination with lower resistance to deformation and the highest bioavailability of calcium and phosphate. Group 2 samples are most promising for clinical use.


Asunto(s)
Calcio , Durapatita
18.
Proc Natl Acad Sci U S A ; 115(5): 909-914, 2018 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-29339509

RESUMEN

Measuring vital physiological pressures is important for monitoring health status, preventing the buildup of dangerous internal forces in impaired organs, and enabling novel approaches of using mechanical stimulation for tissue regeneration. Pressure sensors are often required to be implanted and directly integrated with native soft biological systems. Therefore, the devices should be flexible and at the same time biodegradable to avoid invasive removal surgery that can damage directly interfaced tissues. Despite recent achievements in degradable electronic devices, there is still a tremendous need to develop a force sensor which only relies on safe medical materials and requires no complex fabrication process to provide accurate information on important biophysiological forces. Here, we present a strategy for material processing, electromechanical analysis, device fabrication, and assessment of a piezoelectric Poly-l-lactide (PLLA) polymer to create a biodegradable, biocompatible piezoelectric force sensor, which only employs medical materials used commonly in Food and Drug Administration-approved implants, for the monitoring of biological forces. We show the sensor can precisely measure pressures in a wide range of 0-18 kPa and sustain a reliable performance for a period of 4 d in an aqueous environment. We also demonstrate this PLLA piezoelectric sensor can be implanted inside the abdominal cavity of a mouse to monitor the pressure of diaphragmatic contraction. This piezoelectric sensor offers an appealing alternative to present biodegradable electronic devices for the monitoring of intraorgan pressures. The sensor can be integrated with tissues and organs, forming self-sensing bionic systems to enable many exciting applications in regenerative medicine, drug delivery, and medical devices.


Asunto(s)
Implantes Absorbibles , Monitoreo Fisiológico/instrumentación , Presión , Animales , Fenómenos Biomecánicos , Electricidad , Humanos , Ratones , Poliésteres
19.
Proc Natl Acad Sci U S A ; 115(41): 10239-10244, 2018 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-30224483

RESUMEN

Biodegradable polymers open the way to treatment of heart disease using transient implants (bioresorbable vascular scaffolds, BVSs) that overcome the most serious complication associated with permanent metal stents-late stent thrombosis. Here, we address the long-standing paradox that the clinically approved BVS maintains its radial strength even after 9 mo of hydrolysis, which induces a ∼40% decrease in the poly l-lactide molecular weight (Mn). X-ray microdiffraction evidence of nonuniform hydrolysis in the scaffold reveals that regions subjected to tensile stress during crimping develop a microstructure that provides strength and resists hydrolysis. These beneficial morphological changes occur where they are needed most-where stress is localized when a radial load is placed on the scaffold. We hypothesize that the observed decrease in Mn reflects the majority of the material, which is undeformed during crimping. Thus, the global measures of degradation may be decoupled from the localized, degradation-resistant regions that confer the ability to support the artery for the first several months after implantation.


Asunto(s)
Implantes Absorbibles , Poliésteres/química , Andamios del Tejido/química , Hidrólisis , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Microtomía , Peso Molecular , Difracción de Rayos X
20.
Int J Mol Sci ; 22(7)2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33808501

RESUMEN

In this research, we prepared foam scaffolds based on poly(l-lactide) (PLLA) and apatite whiskers (HAP) using thermally induced phase separation technique supported by the salt leaching process (TIPS-SL). Using sodium chloride having a size of (a) 150-315 µm, (b) 315-400 µm, and (c) 500-600 µm, three types of foams with different pore sizes have been obtained. Internal structure of the obtained materials has been investigated using SEM as well as µCT. The materials have been studied by means of porosity, density, and compression tests. As the most promising, the composite prepared with salt size of 500-600 µm was prepared also with the l-lysine modified apatite. The osteoblast hFOB 1.19 cell response for the scaffolds was also investigated by means of cell viability, proliferation, adhesion/penetration, and biomineralization. Direct contact cytotoxicity assay showed the cytocompatibility of the scaffolds. All types of foam scaffolds containing HAP whiskers, regardless the pore size or l-lysine modification induced significant stimulatory effect on the cal-cium deposits formation in osteoblasts. The PLLA/HAP scaffolds modified with l-lysine stimulated hFOB 1.19 osteoblasts proliferation. Compared to the scaffolds with smaller pores (150-315 µm and 315-400 µm), the PLLA/HAP foams with large pores (500-600 µm) promoted more effective ad-hesion of osteoblasts to the surface of the biomaterial.


Asunto(s)
Durapatita/química , Poliésteres/química , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Apatitas/química , Apatitas/metabolismo , Materiales Biocompatibles/química , Línea Celular Tumoral , Humanos , Ácido Láctico/metabolismo , Lisina/química , Lisina/metabolismo , Osteoblastos/metabolismo , Poliésteres/metabolismo , Polímeros/química , Porosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA