Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Am J Obstet Gynecol ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38969197

RESUMEN

Fluid management in obstetrical care is crucial because of the complex physiological conditions of pregnancy, which complicate clinical manifestations and fluid balance management. This expert review examined the use of point-of-care ultrasound to evaluate and monitor the response to fluid therapy in pregnant patients. Pregnancy induces substantial physiological changes, including increased cardiac output and glomerular filtration rate, decreased systemic vascular resistance, and decreased plasma oncotic pressure. Conditions, such as preeclampsia, further complicate fluid management because of decreased intravascular volume and increased capillary permeability. Traditional methods for assessing fluid volume status, such as physical examination and invasive monitoring, are often unreliable or inappropriate. Point-of-care ultrasound provides a noninvasive, rapid, and reliable means to assess fluid responsiveness, which is essential for managing fluid therapy in pregnant patients. This review details the various point-of-care ultrasound modalities used to measure dynamic changes in fluid status, focusing on the evaluation of the inferior vena cava, lung ultrasound, and left ventricular outflow tract. Inferior vena cava ultrasound in spontaneously breathing patients determines diameter variability, predicts fluid responsiveness, and is feasible even late in pregnancy. Lung ultrasound is crucial for detecting early signs of pulmonary edema before clinical symptoms arise and is more accurate than traditional radiography. The left ventricular outflow tract velocity time integral assesses stroke volume response to fluid challenges, providing a quantifiable measure of cardiac function, which is particularly beneficial in critical care settings where rapid and accurate fluid management is essential. This expert review synthesizes current evidence and practice guidelines, suggesting the integration of point-of-care ultrasound as a fundamental aspect of fluid management in obstetrics. It calls for ongoing research to enhance techniques and validate their use in broader clinical settings, aiming to improve outcomes for pregnant patients and their babies by preventing complications associated with both under- and overresuscitation.

2.
J Cardiothorac Vasc Anesth ; 38(2): 459-465, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38114373

RESUMEN

OBJECTIVE: The authors aimed to evaluate the precision of changes in systolic-pressure variation after passive leg raising (PLR) as a predictor of fluid responsiveness in postoperative critically ill patients, and to compare the precision of changes in pulse-pressure variation after PLR (ΔPPVPLR) with changes in systolic-pressure variation after PLR (ΔSPVPLR). DESIGN: A prospective observational study. SETTING: A surgical intensive care unit of a tertiary hospital. PARTICIPANTS: Seventy-four postoperative critically ill patients with acute circulatory failure were enrolled. INTERVENTIONS: Fluid responsiveness was defined as an increase of 10% or more in stroke volume after PLR, dividing patients into 2 groups: responders and nonresponders. MEASUREMENT AND MAIN RESULTS: Hemodynamic data were recorded at baseline and after PLR, and the stroke volume was measured by transthoracic echocardiography. Thirty-eight patients were responders, and 36 were nonresponders. ΔPPVPLR predicted fluid responsiveness with an area under the receiver operating characteristic curve (AUC) of 0.917, and the optimal cutoff value was 2.3%, with a gray zone of 1.6% to 3.3%, including 19 (25.7%) patients. ΔSPVPLR predicted fluid responsiveness with an AUC of 0.908, and the optimal cutoff value was 1.9%, with a gray zone of 1.1% to 2.0%, including 18 (24.3%) patients. No notable distinction was observed between the AUC for ΔPPVPLR and ΔSPVPLR (p = 0.805) in predicting fluid responsiveness. CONCLUSIONS: ΔSPVPLR and ΔPPVPLR could accurately predict fluid responsiveness in postoperative critically ill patients. There was no difference in the ability to predict fluid responsiveness between ΔSPVPLR and ΔPPVPLR.


Asunto(s)
Enfermedad Crítica , Pierna , Humanos , Fluidoterapia , Presión Sanguínea , Hemodinámica , Volumen Sistólico , Respiración Artificial
3.
J Clin Monit Comput ; 38(2): 313-323, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38064135

RESUMEN

Dynamic preload parameters are used to guide perioperative fluid management. However, reported cut-off values vary and the presence of a gray zone complicates clinical decision making. Measurement error, intrinsic to the calculation of pulse pressure variation (PPV) has not been studied but could contribute to this level of uncertainty. The purpose of this study was to quantify and compare measurement errors associated with PPV calculations. Hemodynamic data of patients undergoing liver transplantation were extracted from the open-access VitalDatabase. Three algorithms were applied to calculate PPV based on 1 min observation periods. For each method, different durations of sampling periods were assessed. Best Linear Unbiased Prediction was determined as the reference PPV-value for each observation period. A Bayesian model was used to determine bias and precision of each method and to simulate the uncertainty of measured PPV-values. All methods were associated with measurement error. The range of differential and proportional bias were [- 0.04%, 1.64%] and [0.92%, 1.17%] respectively. Heteroscedasticity influenced by sampling period was detected in all methods. This resulted in a predicted range of reference PPV-values for a measured PPV of 12% of [10.2%, 13.9%] and [10.3%, 15.1%] for two selected methods. The predicted range in reference PPV-value changes for a measured absolute change of 1% was [- 1.3%, 3.3%] and [- 1.9%, 4%] for these two methods. We showed that all methods that calculate PPV come with varying degrees of uncertainty. Accounting for bias and precision may have important implications for the interpretation of measured PPV-values or PPV-changes.


Asunto(s)
Fluidoterapia , Hemodinámica , Humanos , Presión Sanguínea , Teorema de Bayes , Fluidoterapia/métodos , Algoritmos , Volumen Sistólico
4.
J Clin Monit Comput ; 38(1): 57-67, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37968547

RESUMEN

Pulse pressure variation (PPV) is a well-established method for predicting fluid responsiveness in mechanically ventilated patients. The predictive accuracy is, however, disputed for ventilation with low tidal volume (VT) or low heart-rate-to-respiratory-rate ratio (HR/RR). We investigated the effects of VT and RR on PPV and on PPV's ability to predict fluid responsiveness. We included patients scheduled for open abdominal surgery. Prior to a 250 ml fluid bolus, we ventilated patients with combinations of VT from 4 to 10 ml kg-1 and RR from 10 to 31 min-1. For each of 10 RR-VT combinations, PPV was derived using both a classic approach and a generalized additive model (GAM) approach. The stroke volume (SV) response to fluid was evaluated using uncalibrated pulse contour analysis. An SV increase > 10% defined fluid responsiveness. Fifty of 52 included patients received a fluid bolus. Ten were fluid responders. For all ventilator settings, fluid responsiveness prediction with PPV was inconclusive with point estimates for the area under the receiver operating characteristics curve between 0.62 and 0.82. Both PPV measures were nearly proportional to VT. Higher RR was associated with lower PPV. Classically derived PPV was affected more by RR than GAM-derived PPV. Correcting PPV for VT could improve PPV's predictive utility. Low HR/RR has limited effect on GAM-derived PPV, indicating that the low HR/RR limitation is related to how PPV is calculated. We did not demonstrate any benefit of GAM-derived PPV in predicting fluid responsiveness.Trial registration: ClinicalTrials.gov, reg. March 6, 2020, NCT04298931.


Asunto(s)
Fluidoterapia , Frecuencia Respiratoria , Humanos , Presión Sanguínea/fisiología , Volumen de Ventilación Pulmonar , Fluidoterapia/métodos , Volumen Sistólico/fisiología , Pulmón , Respiración Artificial/métodos , Hemodinámica/fisiología
5.
Rev Cardiovasc Med ; 24(8): 242, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39076719

RESUMEN

Background: Pulse pressure variation (PPV) is based on heart-lung interaction and its association with the imbalance between pulmonary and systemic blood flow (Qp:Qs) has been understudied. We hypothesized that (1) baseline PPV (after induction of anesthesia) is different in a mixed congenital heart disease population with different Qp:Qs, (2) baseline PPV is different between a pooled group with high Qp:Qs and one with low Qp:Qs, and (3) a systemic-pulmonary shunt procedure results in reduced PPV compared to baseline. Methods: We retrospectively reviewed the medical charts of children who presented to the operating room for cardiac surgery between 2010 and 2018. General patient characteristics, PPV, and other hemodynamic parameters following the induction of general anesthesia were retrieved. Patients were grouped according to the type of congenital heart disease, and whether the Qp:Qs ratio was higher or lower than 1. We also identified patients who received a systemic-pulmonary shunt in order to evaluate changes in PPV. Results: A total of 1253 patients were included in the study. Baseline PPV differed significantly according to the type of congenital heart disease, with atrial septal defect showing the lowest PPV (9.5 ± 5.6%) and tricuspid valve malformation the highest (21.8 ± 14.1%). The high Qp:Qs group (n = 932) had significantly lower PPV compared to the low Qp:Qs group (n = 321; 11.8 ± 5.7% vs. 14.9 ± 7.9%, respectively; p < 0.001). PPV decreased significantly following systemic-pulmonary shunt. Conclusions: PPV was associated with Qp:Qs imbalance in children undergoing general anesthesia for cardiac surgery. A lower PPV was associated with increased Qp:Qs. Clinicians should take this into account when using PPV to evaluate volume status and when conducting clinical trials in a mixed population of patients with congenital heart disease.

6.
Crit Care ; 27(1): 431, 2023 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-37940953

RESUMEN

BACKGROUND: Pulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia. METHODS: Systematic review and metanalysis of PPV and SVV use in surgical adult patients. The QUADAS-2 scale was used to assess the risk of bias of included studies. We adopted a metanalysis pooling of aggregate data from 5 subgroups of studies with random effects models using the common-effect inverse variance model. The area under the curve (AUC) of pooled receiving operating characteristics (ROC) curves was reported. A metaregression was performed using FC type, volume, and rate as independent variables. RESULTS: We selected 59 studies enrolling 2,947 patients, with a median of fluid responders of 55% (46-63). The pooled AUC for the PPV was 0.77 (0.73-0.80), with a mean threshold of 10.8 (10.6-11.0). The pooled AUC for the SVV was 0.76 (0.72-0.80), with a mean threshold of 12.1 (11.6-12.7); 19 studies (32.2%) reported the grey zone of PPV or SVV, with a median of 56% (40-62) and 57% (46-83) of patients included, respectively. In the different subgroups, the AUC and the best thresholds ranged from 0.69 and 0.81 and from 6.9 to 11.5% for the PPV, and from 0.73 to 0.79 and 9.9 to 10.8% for the SVV. A high Vt and the choice of colloids positively impacted on PPV performance, especially among patients with closed chest and abdomen, or in prone position. CONCLUSION: The overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability. TRIAL REGISTRATION: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120.


Asunto(s)
Hemodinámica , Quirófanos , Adulto , Humanos , Presión Sanguínea/fisiología , Volumen Sistólico/fisiología , Reproducibilidad de los Resultados , Coloides , Fluidoterapia , Curva ROC
7.
Crit Care ; 27(1): 45, 2023 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-36732851

RESUMEN

BACKGROUND: Pulse pressure variation (PPV) has been widely used in hemodynamic assessment. Nevertheless, PPV is limited in low tidal volume ventilation. We conducted this systematic review and meta-analysis to evaluate whether the tidal volume challenge (TVC) could improve the feasibility of PPV in patients ventilated at low tidal volumes. METHODS: PubMed, Embase and Cochrane Library inception to October 2022 were screened for diagnostic researches relevant to the predictability of PPV change after TVC in low tidal volume ventilatory patients. Summary receiving operating characteristic curve (SROC), pooled sensitivity and specificity were calculated. Subgroup analyses were conducted for possible influential factors of TVC. RESULTS: Ten studies with a total of 429 patients and 457 measurements were included for analysis. The predictive performance of PPV was significantly lower than PPV change after TVC in low tidal volume, with mean area under the receiving operating characteristic curve (AUROC) of 0.69 ± 0.13 versus 0.89 ± 0.10. The SROC of PPV change yielded an area under the curve of 0.96 (95% CI 0.94, 0.97), with overall pooled sensitivity and specificity of 0.92 (95% CI 0.83, 0.96) and 0.88 (95% CI 0.76, 0.94). Mean and median cutoff value of the absolute change of PPV (△PPV) were 2.4% and 2%, and that of the percentage change of PPV (△PPV%) were 25% and 22.5%. SROC of PPV change in ICU group, supine or semi-recumbent position group, lung compliance less than 30 cm H2O group, moderate positive end-expiratory pressure (PEEP) group and measurements devices without transpulmonary thermodilution group yielded 0.95 (95%0.93, 0.97), 0.95 (95% CI 0.92, 0.96), 0.96 (95% CI 0.94, 0.97), 0.95 (95% CI 0.93, 0.97) and 0.94 (95% CI 0.92, 0.96) separately. The lowest AUROCs of PPV change were 0.59 (95% CI 0.31, 0.88) in prone position and 0.73 (95% CI 0.60, 0.84) in patients with spontaneous breathing activity. CONCLUSIONS: TVC is capable to help PPV overcome limitations in low tidal volume ventilation, wherever in ICU or surgery. The accuracy of TVC is not influenced by reduced lung compliance, moderate PEEP and measurement tools, but TVC should be cautious applied in prone position and patients with spontaneous breathing activity. Trial registration PROSPERO (CRD42022368496). Registered on 30 October 2022.


Asunto(s)
Respiración con Presión Positiva , Respiración Artificial , Humanos , Presión Sanguínea , Volumen de Ventilación Pulmonar , Estudios de Factibilidad , Hemodinámica , Volumen Sistólico , Fluidoterapia
8.
Crit Care ; 27(1): 361, 2023 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-37730622

RESUMEN

INTRODUCTION: Prediction of fluid responsiveness in acutely ill patients might be influenced by a number of clinical and technical factors. We aim to identify variables potentially modifying the operative performance of fluid responsiveness predictors commonly used in clinical practice. METHODS: A sensitive strategy was conducted in the Medline and Embase databases to search for prospective studies assessing the operative performance of pulse pressure variation, stroke volume variation, passive leg raising (PLR), end-expiratory occlusion test (EEOT), mini-fluid challenge, and tidal volume challenge to predict fluid responsiveness in critically ill and acutely ill surgical patients published between January 1999 and February 2023. Adjusted diagnostic odds ratios (DORs) were calculated by subgroup analyses (inverse variance method) and meta-regression (test of moderators). Variables potentially modifying the operative performance of such predictor tests were classified as technical and clinical. RESULTS: A total of 149 studies were included in the analysis. The volume used during fluid loading, the method used to assess variations in macrovascular flow (cardiac output, stroke volume, aortic blood flow, volume‒time integral, etc.) in response to PLR/EEOT, and the apneic time selected during the EEOT were identified as technical variables modifying the operative performance of such fluid responsiveness predictor tests (p < 0.05 for all adjusted vs. unadjusted DORs). In addition, the operative performance of fluid responsiveness predictors was also influenced by clinical variables such as the positive end-expiratory pressure (in the case of EEOT) and the dose of norepinephrine used during the fluid responsiveness assessment for PLR and EEOT (for all adjusted vs. unadjusted DORs). CONCLUSION: Prediction of fluid responsiveness in critically and acutely ill patients is strongly influenced by a number of technical and clinical aspects. Such factors should be considered for individual intervention decisions.


Asunto(s)
Aorta , Humanos , Estudios Prospectivos , Presión Sanguínea , Gasto Cardíaco , Bases de Datos Factuales
9.
Br J Anaesth ; 130(4): 390-393, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36732140

RESUMEN

'Goal-directed haemodynamic therapy' describes various haemodynamic treatment strategies that have in common that interventions are titrated to achieve predefined haemodynamic targets. However, the treatment strategies differ substantially regarding the underlying haemodynamic target variables and target values, and thus presumably have different effects on outcome. It is an over-simplifying approach to lump complex and substantially differing haemodynamic treatment strategies together under the term 'goal-directed haemodynamic therapy', an imprecise umbrella term that we should thus stop using.


Asunto(s)
Objetivos , Hemodinámica , Humanos , Fluidoterapia
10.
BMC Anesthesiol ; 23(1): 60, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36849887

RESUMEN

BACKGROUND: Aim of this study is to test the predictive value of Pulse Wave Transit Time (PWTT) for fluid responsiveness in comparison to the established fluid responsiveness parameters pulse pressure (ΔPP) and corrected flow time (FTc) during major abdominal surgery. METHODS: Forty patients undergoing major abdominal surgery were enrolled with continuous monitoring of PWTT (LifeScope® Modell J BSM-9101 Nihon Kohden Europe GmbH, Rosbach, Germany) and stroke volume (Esophageal Doppler Monitoring CardioQ-ODM®, Deltex Medical Ltd, Chichester, UK). In case of hypovolemia (difference in pulse pressure [∆PP] ≥ 9%, corrected flow time [FTc] ≤ 350 ms) a fluid bolus of 7 ml/kg ideal body weight was administered. Receiver operating characteristics (ROC) curves and corresponding areas under the curve (AUCs) were used to compare different methods of determining PWTT. A Wilcoxon test was used to discriminate fluid responders (increase in stroke volume of ≥ 10%) from non-responders. The predictive value of PWTT for fluid responsiveness was compared by testing for differences between ROC curves of PWTT, ΔPP and FTc using the methods by DeLong. RESULTS: AUCs (area under the ROC-curve) to predict fluid responsiveness for PWTT-parameters were 0.61 (raw c finger Q), 0.61 (raw c finger R), 0.57 (raw c ear Q), 0.53 (raw c ear R), 0.54 (raw non-c finger Q), 0.52 (raw non-c finger R), 0.50 (raw non-c ear Q), 0.55 (raw non-c ear R), 0.63 (∆ c finger Q), 0.61 (∆ c finger R), 0.64 (∆ c ear Q), 0.66 (∆ c ear R), 0.59 (∆ non-c finger Q), 0.57 (∆ non-c finger R), 0.57 (∆ non-c ear Q), 0.61 (∆ non-c ear R) [raw measurements vs. ∆ = respiratory variation; c = corrected measurements according to Bazett's formula vs. non-c = uncorrected measurements; Q vs. R = start of PWTT-measurements with Q- or R-wave in ECG; finger vs. ear = pulse oximetry probe location]. Hence, the highest AUC to predict fluid responsiveness by PWTT was achieved by calculating its respiratory variation (∆PWTT), with a pulse oximeter attached to the earlobe, using the R-wave in ECG, and correction by Bazett's formula (AUC best-PWTT 0.66, 95% CI 0.54-0.79). ∆PWTT was sufficient to discriminate fluid responders from non-responders (p = 0.029). No difference in predicting fluid responsiveness was found between best-PWTT and ∆PP (AUC 0.65, 95% CI 0.51-0.79; p = 0.88), or best-PWTT and FTc (AUC 0.62, 95% CI 0.49-0.75; p = 0.68). CONCLUSION: ΔPWTT shows poor ability to predict fluid responsiveness intraoperatively. Moreover, established alternatives ΔPP and FTc did not perform better. TRIAL REGISTRATION: Prior to enrolement on clinicaltrials.gov (NC T03280953; date of registration 13/09/2017).


Asunto(s)
Líquidos Corporales , Dedos , Humanos , Extremidad Superior , Presión Sanguínea , Europa (Continente)
11.
BMC Anesthesiol ; 23(1): 360, 2023 11 06.
Artículo en Inglés | MEDLINE | ID: mdl-37932674

RESUMEN

BACKGROUND: Respiratory variation in the internal jugular vein (IJVV) has not shown promising results in predicting volume responsiveness in ventilated patients with low tidal volume (Vt) in prone position. We aimed to determine whether the baseline respiratory variation in the IJVV value measured by ultrasound might predict fluid responsiveness in patients with adolescent idiopathic scoliosis (AIS) undergoing posterior spinal fusion (PSF) with low Vt. METHODS: According to the fluid responsiveness results, the included patients were divided into two groups: those who responded to volume expansion, denoted the responder group, and those who did not respond, denoted the non-responder group. The primary outcome was determination of the value of baseline IJVV in predicting fluid responsiveness (≥15% increases in stroke volume index (SVI) after 7 ml·kg-1 colloid administration) in patients with AIS undergoing PSF during low Vt ventilation. Secondary outcomes were estimation of the diagnostic performance of pulse pressure variation (PPV), stroke volume variation (SVV), and the combination of IJVV and PPV in predicting fluid responsiveness in this surgical setting. The ability of each parameter to predict fluid responsiveness was assessed using a receiver operating characteristic curve. RESULTS: Fifty-six patients were included, 36 (64.29%) of whom were deemed fluid responsive. No significant difference in baseline IJVV was found between responders and non-responders (25.89% vs. 23.66%, p = 0.73), and no correlation was detected between baseline IJVV and the increase in SVI after volume expansion (r = 0.14, p = 0.40). A baseline IJVV greater than 32.00%, SVV greater than 14.30%, PPV greater than 11.00%, and a combination of IJVV and PPV greater than 64.00% had utility in identifying fluid responsiveness, with a sensitivity of 33.33%, 77.78%, 55.56%, and 55.56%, respectively, and a specificity of 80.00%, 50.00%, 65.00%, and 65.00%, respectively. The area under the receiver operating characteristic curve for the baseline values of IJVV, SVV, PPV, and the combination of IJVV and PPV was 0.52 (95% CI, 0.38-0.65, p=0.83), 0.54 (95% CI, 0.40-0.67, p=0.67), 0.58 (95% CI, 0.45-0.71, p=0.31), and 0.57 (95% CI, 0.43-0.71, p=0.37), respectively. CONCLUSIONS: Ultrasonic-derived IJVV lacked accuracy in predicting fluid responsiveness in patients with AIS undergoing PSF during low Vt ventilation. In addition, the baseline values of PPV, SVV, and the combination of IJVV and PPV did not predict fluid responsiveness in this surgical setting. TRAIL REGISTRATION: This trial was registered at www.chictr.org (ChiCTR2200064947) on 24/10/2022. All data were collected through chart review.


Asunto(s)
Cifosis , Escoliosis , Adolescente , Humanos , Presión Sanguínea , Fluidoterapia/métodos , Hemodinámica , Venas Yugulares , Posición Prona , Estudios Prospectivos , Respiración Artificial/métodos , Curva ROC , Volumen Sistólico
12.
J Cardiothorac Vasc Anesth ; 37(3): 407-414, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36529634

RESUMEN

OBJECTIVES: The identification of potential hemodynamic indicators to increase the predictive power of stroke-volume variation (SVV) for mean arterial pressure (MAP) and stroke volume (SV) fluid responsiveness. DESIGN: A prospective intervention study. SETTING: At a single-center university hospital. PARTICIPANTS: Nineteen patients during major vascular surgery with 125 fluid interventions. INTERVENTIONS: When SVV ≥13% occurred for >30 seconds, 250 mL of Ringer's lactate were given within 2 minutes. MEASUREMENTS AND MAIN RESULTS: Hemodynamic variables, such as pulse-pressure variation (PPV) and dynamic arterial elastance (Edyn), were measured by pulse power-wave analysis. The outcomes were MAP and SV responsiveness, defined as an increase of at least 10% of MAP and SV within 5 minutes of the fluid intervention. Of the fluid interventions, 48% were MAP-responsive, and 66% were SV-responsive. The addition of PPV and Edyn cut-off values to the SVV cut-off decreased sensitivity from 1-to-0.66 to-0.82, and concomitantly increased specificity from 0-to- 0.65-to-0.93 for the prediction of MAP and SV responsiveness in the authors' study setting. The areas under the receiver operating characteristic curves of PPV and Edyn for the prediction of MAP responsiveness were 0.79 and 0.75, respectively. The areas under the receiver operating characteristic curves for PPV and Edyn to predict SV responsiveness were 0.85 and 0.77, respectively. CONCLUSIONS: The PPV and Edyn showed good accuracy for the prediction of MAP and SV responsiveness in patients with elevated SVV during vascular surgery. Either PPV or Edyn may be used in conjunction with SVV to better predict MAP and SV fluid responsiveness in patients undergoing vascular surgery.


Asunto(s)
Presión Arterial , Fluidoterapia , Humanos , Volumen Sistólico , Estudios Prospectivos , Presión Sanguínea , Hemodinámica , Curva ROC , Procedimientos Quirúrgicos Vasculares
13.
J Cardiothorac Vasc Anesth ; 37(8): 1382-1389, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37100636

RESUMEN

OBJECTIVES: To compare noninvasive pulse-pressure variation (PPV) measurements obtained from a new high-fidelity upper arm cuff using a hydraulic coupling technique to corresponding intraarterial PPV measurements. DESIGN: The authors used prospective multicenter comparison and development studies for the new high-fidelity upper arm cuff. SETTING: The study was performed in the departments of Anesthesiology at the Ludwig-Maximilians-Universität München Hospital, the University Hospital of Bonn, and the RoMed Hospital in Rosenheim (all Germany). PARTICIPANTS: A total of 153 patients were enrolled, undergoing major abdominal surgery or neurosurgery with mechanical ventilation. For the evaluation of PPV, 1,467 paired measurements in 107 patients were available after exclusion due to predefined quality criteria. INTERVENTIONS: Simultaneous measurements of PPV were performed from a reference femoral arterial catheter (PPVref) and the high-fidelity upper arm cuff (PPVcuff). The new device uses a semirigid conical shell. It incorporates a hydraulic sensor pad with a pressure transducer, leading to a tissue pressure-pulse contour with all characteristics of an arterial- pulse contour. MEASUREMENTS AND MAIN RESULTS: The comparative analysis of the included measurements showed that PPVref and PPVcuff were closely correlated (r = 0.92). The mean of the differences between PPVref and PPVcuff was 0.1 ± 2.0%, with 95% limits of agreement between -4.1% and 3.9%. To track absolute changes in PPV >2%, the concordance rate between the 2 methods was 93%. CONCLUSIONS: The new high-fidelity upper arm cuff method provided a clinically reliable estimate of PPV.


Asunto(s)
Brazo , Determinación de la Presión Sanguínea , Humanos , Determinación de la Presión Sanguínea/métodos , Estudios Prospectivos , Presión Sanguínea , Anestesia General
14.
Vet Anaesth Analg ; 50(3): 211-219, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36967326

RESUMEN

OBJECTIVE: To demonstrate if modified passive leg raise (PLRM) maneuver can be used for volumetric evaluation of fluid responsiveness (FR) by inducing cardiac output (CO) changes during experimental induction and correction of hypovolemia in healthy anesthetized dogs. The effects of PLRM on plethysmographic variability index (PVI) and pulse pressure variation (PPV) were also investigated. STUDY DESIGN: Prospective, crossover study. ANIMALS: A total of six healthy anesthetized Beagle dogs. METHODS: Dogs were anesthetized with propofol and isoflurane. They were mechanically ventilated under neuromuscular blockade, and normothermia was maintained. After instrumentation, all dogs were subjected to four stages: 1, baseline; 2, removal of 27 mL kg-1 circulating blood volume; 3, after blood re-transfusion; and 4, after 20 mL kg-1 hetastarch infusion over 20 minutes. A 10 minute stabilization period was allowed after induction of each stage and before data collection. At each stage, CO via pulmonary artery thermodilution, PVI, PPV and cardiopulmonary variables were measured before, during and after the PLRM maneuver. Stages were sequential, not randomized. Statistical analysis included repeated measures anova and Tukey's post hoc test, considering p < 0.05 as significant. RESULTS: During stage 2, PLRM at a 30° angle significantly increased CO (mean ± standard deviation, 1.0 ± 0.1 to 1.3 ± 0.1 L minute-1; p < 0.001), with a simultaneous significant reduction in PVI (38 ± 4% to 21 ± 4%; p < 0.001) and PPV (27 ± 2% to 18 ± 2%; p < 0.001). The PLRM did not affect CO, PPV and PVI during stages 1, 3 and 4. CONCLUSIONS AND CLINICAL RELEVANCE: In anesthetized dogs, PLRM at a 30° angle successfully detected FR during hypovolemia, and identified fluid nonresponsiveness during normovolemia and hypervolemia. Also, in hypovolemic dogs, significant decreases in PVI and PPV occurred in response to PLRM maneuver.


Asunto(s)
Anestésicos por Inhalación , Enfermedades de los Perros , Perros , Animales , Hipovolemia/terapia , Hipovolemia/veterinaria , Hemodinámica , Anestésicos por Inhalación/farmacología , Estudios Prospectivos , Estudios Cruzados , Presión Sanguínea
15.
Yale J Biol Med ; 96(1): 107-123, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-37009197

RESUMEN

Goal-directed fluid therapy (GDFT) is usually recommended in patients undergoing major surgery and is essential in enhanced recovery after surgery (ERAS) protocols. This fluid regimen is usually guided by dynamic hemodynamic parameters and aims to optimize patients' cardiac output to maximize oxygen delivery to their vital organs. While many studies have shown that GDFT benefits patients perioperatively and can decrease postoperative complications, there is no consensus on which dynamic hemodynamic parameters to guide GDFT with. Furthermore, there are many commercialized hemodynamic monitoring systems to measure these dynamic hemodynamic parameters, and each has its pros and cons. This review will discuss and review the commonly used GDFT dynamic hemodynamic parameters and hemodynamic monitoring systems.


Asunto(s)
Objetivos , Complicaciones Posoperatorias , Humanos , Hemodinámica , Fluidoterapia/métodos
16.
Crit Care ; 26(1): 219, 2022 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-35850771

RESUMEN

BACKGROUND: Prone position is frequently used in patients with acute respiratory distress syndrome (ARDS), especially during the Coronavirus disease 2019 pandemic. Our study investigated the ability of pulse pressure variation (PPV) and its changes during a tidal volume challenge (TVC) to assess preload responsiveness in ARDS patients under prone position. METHODS: This was a prospective study conducted in a 25-bed intensive care unit at a university hospital. We included patients with ARDS under prone position, ventilated with 6 mL/kg tidal volume and monitored by a transpulmonary thermodilution device. We measured PPV and its changes during a TVC (ΔPPV TVC6-8) after increasing the tidal volume from 6 to 8 mL/kg for one minute. Changes in cardiac index (CI) during a Trendelenburg maneuver (ΔCITREND) and during end-expiratory occlusion (EEO) at 8 mL/kg tidal volume (ΔCI EEO8) were recorded. Preload responsiveness was defined by both ΔCITREND ≥ 8% and ΔCI EEO8 ≥ 5%. Preload unresponsiveness was defined by both ΔCITREND < 8% and ΔCI EEO8 < 5%. RESULTS: Eighty-four sets of measurements were analyzed in 58 patients. Before prone positioning, the ratio of partial pressure of arterial oxygen to fraction of inspired oxygen was 104 ± 27 mmHg. At the inclusion time, patients were under prone position for 11 (2-14) hours. Norepinephrine was administered in 83% of cases with a dose of 0.25 (0.15-0.42) µg/kg/min. The positive end-expiratory pressure was 14 (11-16) cmH2O. The driving pressure was 12 (10-17) cmH2O, and the respiratory system compliance was 32 (22-40) mL/cmH2O. Preload responsiveness was detected in 42 cases. An absolute change in PPV ≥ 3.5% during a TVC assessed preload responsiveness with an area under the receiver operating characteristics (AUROC) curve of 0.94 ± 0.03 (sensitivity: 98%, specificity: 86%) better than that of baseline PPV (0.85 ± 0.05; p = 0.047). In the 56 cases where baseline PPV was inconclusive (≥ 4% and < 11%), ΔPPV TVC6-8 ≥ 3.5% still enabled to reliably assess preload responsiveness (AUROC: 0.91 ± 0.05, sensitivity: 97%, specificity: 81%; p < 0.01 vs. baseline PPV). CONCLUSION: In patients with ARDS under low tidal volume ventilation during prone position, the changes in PPV during a TVC can reliably assess preload responsiveness without the need for cardiac output measurements. TRIAL REGISTRATION: ClinicalTrials.gov (NCT04457739). Registered 30 June 2020 -Retrospectively registered, https://clinicaltrials.gov/ct2/show/record/NCT04457739.


Asunto(s)
Posición Prona , Respiración Artificial , Síndrome de Dificultad Respiratoria , Volumen de Ventilación Pulmonar , COVID-19/epidemiología , Humanos , Pandemias , Posición Prona/fisiología , Estudios Prospectivos , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Volumen de Ventilación Pulmonar/fisiología , Resultado del Tratamiento
17.
Pediatr Transplant ; 26(5): e14267, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35279933

RESUMEN

BACKGROUND: The primary objective was to evaluate associations between perioperative clinical variables and postoperative hemodynamic indices after HT with the development of severe AKI. The secondary objective was to evaluate associations between UOP or creatinine as AKI indicators and morbidity after HT. METHODS: Retrospective study of all patients who underwent HT 1/2016-11/2019 at a quaternary pediatric institution. Severe AKI was defined as KDIGO stage 2 or higher. RESULTS: Of 94 HT patients, 73 met inclusion criteria; 45% of patients developed severe AKI. In univariate analysis, non-Hispanic Black race, preoperative AKI, longer CPB duration, lower weight, and peak lactate within 12 h post-HT were associated with severe AKI. CVP ≤12 h post-HT had a quadratic relationship, rather than linear, with severe AKI. PPV >18% was significantly associated with severe AKI but equated to noncontiguous 10 min of high variation over a 12-h period, and thus was deemed not clinically significant. In multivariate analysis, Black race, longer CPB duration, and higher CVP remained associated with severe AKI (c: 0.84, 95% CI 0.73-0.92). Severe AKI per creatinine, but not UOP criteria, was associated with longer duration of ventilation (p = .012) and longer intensive care unit length of stay (p = .003). CONCLUSIONS: In pediatric HT patients, non-Hispanic Black race, longer CPB time, and higher postoperative CVP ≤12 h post-HT were associated with severe AKI. AKI based on creatinine, not UOP, was associated with postoperative HT morbidity.


Asunto(s)
Lesión Renal Aguda , Trasplante de Corazón , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Niño , Creatinina , Humanos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo
18.
Br J Anaesth ; 129(3): 308-316, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35842352

RESUMEN

BACKGROUND: Passive leg raising-induced changes in cardiac index can be used to predict fluid responsiveness. We investigated whether passive leg raising-induced changes in pulse pressure variation (ΔPPVPLR) can also predict fluid responsiveness in mechanically ventilated patients. METHODS: In this multicentre prospective observational study, we included 270 critically ill patients on mechanical ventilation in whom volume expansion was indicated because of acute circulatory failure. We did not include patients with cardiac arrythmias. Cardiac index and PPV were measured before/during a passive leg raising test and before/after volume expansion. A volume expansion-induced increase in cardiac index of >15% defined fluid responsiveness. To investigate whether ΔPPVPLR can predict fluid responsiveness, we determined areas under the receiver operating characteristic curves (AUROCs) and grey zones for relative and absolute ΔPPVPLR. RESULTS: Of the 270 patients, 238 (88%) were on controlled mechanical ventilation with no spontaneous breathing activity and 32 (12%) were on pressure support ventilation. The median tidal volume was 7.1 (inter-quartile range [IQR], 6.6-7.6) ml kg-1 ideal body weight. One hundred sixty-four patients (61%) were fluid responders. Relative and absolute ΔPPVPLR predicted fluid responsiveness with an AUROC of 0.92 (95% confidence interval [95% CI], 0.88-0.95; P<0.001) each. The grey zone for relative and absolute ΔPPVPLR included 4.8% and 22.6% of patients, respectively. These results were not affected by ventilatory mode and baseline characteristics (type of shock, centre, vasoactive treatment). CONCLUSIONS: Passive leg raising-induced changes in pulse pressure variation accurately predict fluid responsiveness with a small grey zone in critically ill patients on mechanical ventilation. CLINICAL TRIAL REGISTRATION: NCT03225378.


Asunto(s)
Fluidoterapia , Respiración Artificial , Presión Sanguínea , Gasto Cardíaco , Enfermedad Crítica/terapia , Fluidoterapia/métodos , Hemodinámica , Humanos , Pierna , Estudios Prospectivos , Volumen Sistólico
19.
BMC Anesthesiol ; 22(1): 137, 2022 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-35508962

RESUMEN

BACKGROUND: The prediction accuracy of pulse pressure variation (PPV) for fluid responsiveness was proposed to be unreliable in low tidal volume (Vt) ventilation. It was suggested that changes in PPV obtained by transiently increasing Vt to 8 ml/kg accurately predicted fluid responsiveness even in subjects receiving low Vt. We assessed whether the changes in PPV induced by a Vt challenge predicted fluid responsiveness in our critically ill subjects ventilated with low Vt 6 ml/kg. METHODS: This study is a prospective single-center study. PPV and other parameters were measured at a Vt of 6 mL/kg, 8 mL/kg, and after volume expansion. The prediction accuracy of PPV and other parameters for fluid responsiveness before and after tidal volume challenge was also analyzed using receiver operating characteristic (ROC) curves. RESULTS: Thirty-one of the 76 subjects enrolled in the study were responders (41%). Respiratory system compliance of all subjects decreased significantly (26 ± 4.3). The PPV values were significantly higher in the responder group than the non-responder group before (8.8 ± 2.7 vs 6.8 ± 3.1) or after (13.0 ± 1.7 vs 8.5 ± 3.0) Vt challenge. In the receiver operating characteristic curve (ROC) analysis, PPV6 showed unsatisfactory predictive capability with an area under the curve (AUC) of 0.69 (95%CI, 0.57-0.79, p = 0.002) at a Vt of 6 mL/kg. PPV8 andΔPPV6-8 showed good predictive capability with an AUC of 0.90 (95% CI, 0.81-0.96, p < 0.001) and 0.90 (95% CI, 0.80-0.95, P < 0.001) respectively. The corresponding cutoff values were 11% for PPV8 and 2% for ΔPPV6-8. CONCLUSIONS: PPV shows a poor operative performance as a predictor of fluid responsiveness in critically ill subjects ventilated with a tidal volume of 6 mL/ kg. Vt challenge could improve the predictive accuracy of PPV to a good but not excellent extent when respiratory system compliance decreased significantly.


Asunto(s)
Enfermedad Crítica , Respiración Artificial , Presión Sanguínea , Enfermedad Crítica/terapia , Fluidoterapia , Hemodinámica , Humanos , Pulmón , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Volumen Sistólico , Volumen de Ventilación Pulmonar
20.
Indian J Crit Care Med ; 26(2): 179-184, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35712738

RESUMEN

Background: Fluid boluses are used in hemodynamically unstable patients with presumed hypovolemia, to improve tissue perfusion, in the perioperative period. Now less invasive methods, such as pulse pressure variation (PPV) and stroke volume variation (SVV) are increasingly being used. We investigated correlation between carotid and brachial artery velocity time integral (VTI) and compared both with PPV and SVV. Methods: We recruited 27 patients undergoing supra-major abdominal surgeries. When indicated (hypotension or increased lactate), a fluid bolus was given after measuring carotid and brachial artery VTI, PPV, and SVV. The change in SV was noted and patients were categorized as responders if the SV increased by >15%. We performed Bland Altman Agreement and calculated best sensitivity and specificity for the parameters. Results: Patients were found to be fluid responders on 29 instances. The correlation between PPV, SVV, carotid and brachial artery VTI was poor and the limits of agreement between them were wide. The Area under Curve (AUC) for PPV was 0.69, for SVV was 0.63, while those of Carotid and Brachial artery VTI (TAP and flow) were (0.53 and 0.54 for carotid) and (0.51 and 0.56 for brachial) respectively. Conclusion: We found poor agreement and weak correlation between both VTi (TAP and flow) measured at carotid and brachial arteries, suggesting that the readings at brachial vessel cannot be used interchangeably with those at carotid artery. The PPV and SVV were better than these parameters for predicting fluid responsiveness; however, their predictive ability (AUROC), sensitivity and specificity were much lower than previously reported. Further studies in this area are therefore required (CTRI Reg No: CTRI/2017/08/009243). How to cite this article: Joshi M, Dhakane P, Bhosale SJ, Phulambrikar R, Kulkarni AP. Correlation between Carotid and Brachial Artery Velocity Time Integral and Their Comparison to Pulse Pressure Variation and Stroke Volume Variation for Assessing Fluid Responsiveness. Indian J Crit Care Med 2022;26(2):179-184.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA