Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Chin J Traumatol ; 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38688817

RESUMEN

PURPOSE: The retear rate of rotator cuff (RC) after surgery is high, and the rapid and functional enthesis regeneration remains a challenge. Whether acellular amniotic membrane (AAM) helps to promote the healing of tendon to bone and which treatment is better are both unclear. The study aims to investigate the effect of AAM on the healing of RC and the best treatment for RC repair. METHODS: Thirty-three Sprague Dawley rats underwent RC transection and repair using microsurgical techniques and were randomly divided into the suturing repair only (SRO) group (n = 11), the AAM overlaying (AOL) group (n = 11), and the AAM interposition (AIP) group (n = 11), respectively. Rats were sacrificed at 4 weeks, then examined by subsequent micro-CT, and evaluated by histologic and biomechanical tests. The statistical analyses of one-way ANOVA or Kruskal-Wallis test were performed using with SPSS 23.0. A p < 0.05 was considered a significant difference. RESULTS: AAM being intervened between tendon and bone (AIP group) or overlaid over tendon to bone junction (AOL group) in a rat model, promoted enthesis regeneration, increased new bone and cartilage generation, and improved collagen arrangement and biomechanical properties in comparison with suturing repair only (SRO group) (AOL vs. SRO, p < 0.001, p = 0.004, p = 0.003; AIP vs. SRO, p < 0.001, p < 0.001, p < 0.001). Compared with the AOL group, the AIP group had better results in micro-CT evaluation, histological score, and biomechanical testing (p = 0 0.039, p = 0.011, p = 0.003, respectively). CONCLUSION: In the RC repair model, AAM enhanced regeneration of the tendon to bone junction. This regeneration was more effective when the AAM was intervened at the tendon to bone interface than overlaid above the tendon to bone junction.

2.
Int Ophthalmol ; 38(1): 395-398, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28176170

RESUMEN

PURPOSE: To report a case of subtotal iridodialysis that was repaired using suturing with the assistance of a guide needle. PATIENT AND METHODS: A 52-year-old man had subtotal iridodialysis of approximately 300° with massive hyphema and vitreous hemorrhage after blunt trauma. The patient was treated with pars plana vitrectomy, and then suturing repair of iridodialysis was performed. RESULTS: After the surgeries, the ratio of pupil area to corneal area is improved from 82.1 to 42.4%. The visual acuity improved to 30/20, and subjective symptoms of glare and monocular diplopia disappeared. There was no remarkable postoperative complication for up to 12 months. CONCLUSIONS: Suturing repair is useful for subtotal iridodialysis and may be an alternative for an iris implant.


Asunto(s)
Lesiones Oculares/complicaciones , Enfermedades del Iris/cirugía , Iris/cirugía , Procedimientos de Cirugía Plástica/métodos , Técnicas de Sutura/instrumentación , Suturas , Heridas no Penetrantes/complicaciones , Lesiones Oculares/diagnóstico , Lesiones Oculares/cirugía , Estudios de Seguimiento , Humanos , Iris/diagnóstico por imagen , Iris/lesiones , Enfermedades del Iris/diagnóstico , Enfermedades del Iris/etiología , Masculino , Persona de Mediana Edad , Agudeza Visual , Vitrectomía/métodos , Heridas no Penetrantes/diagnóstico , Heridas no Penetrantes/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA