Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 351
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Microvasc Res ; : 104731, 2024 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-39134118

RESUMEN

INTRODUCTION: Sufficient perfusion is essential for a safe intestinal anastomosis. Impaired microcirculation may lead to increased bacterial translocation and anastomosis insufficiency. Thus, it is important to estimate well the optimal distance of the anastomosis line from the last mesenterial vessel. However, it is still empiric. In this experiment the aim was to investigate the intestinal microcirculation at various distances from the anastomosis in a pig model. MATERIALS AND METHODS: On 8 anesthetized pigs paramedian laparotomy and end-to-end jejuno-jejunostomy were performed. Using Cytocam-IDF camera, microcirculatory recordings were taken before surgery at the planned suture line, and 1 to 3 mesenterial vessel mural trunk distance from it, and at the same sites 15 and 120 min after anastomosis completion. After the microcirculation monitoring, anastomosed and intact bowel segments were removed to test tensile strength. RESULTS: The proportion and the density of the perfused vessels decreased significantly after anastomosis completion. The perfusion rate increased gradually distal from the anastomosis, and after 120 min these values seemed to be normalized. Anastomosed bowels had significantly lower maximal tensile strength and higher slope of tensile strength curves than intact controls. CONCLUSION: Alterations in microcirculation and tensile strength were observed. After completing the anastomosis, the improvement in perfusion increased gradually away from the wound edge. The IDF device was useful to monitor intestinal microcirculation providing data to estimate better the optimal distance of the anastomosis from the last order mesenteric vessel.

2.
Protein Expr Purif ; 219: 106483, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38609025

RESUMEN

Mussel foot proteins (Mfps) possess unique binding properties to various surfaces due to the presence of L-3,4-dihydroxyphenylalanine (DOPA). Mytilus edulis foot protein-3 (Mefp-3) is one of several proteins in the byssal adhesive plaque. Its localization at the plaque-substrate interface approved that Mefp-3 plays a key role in adhesion. Therefore, the protein is suitable for the development of innovative bio-based binders. However, recombinant Mfp-3s are mainly purified from inclusion bodies under denaturing conditions. Here, we describe a robust and reproducible protocol for obtaining soluble and tag-free Mefp-3 using the SUMO-fusion technology. Additionally, a microbial tyrosinase from Verrucomicrobium spinosum was used for the in vitro hydroxylation of peptide-bound tyrosines in Mefp-3 for the first time. The highly hydroxylated Mefp-3, confirmed by MALDI-TOF-MS, exhibited excellent adhesive properties comparable to a commercial glue. These results demonstrate a concerted and simplified high yield production process for recombinant soluble and tag-free Mfp3-based proteins with on demand DOPA modification.


Asunto(s)
Dihidroxifenilalanina , Mytilus edulis , Animales , Dihidroxifenilalanina/química , Dihidroxifenilalanina/metabolismo , Mytilus edulis/genética , Mytilus edulis/química , Mytilus edulis/metabolismo , Proteínas Recombinantes/genética , Proteínas Recombinantes/biosíntesis , Proteínas Recombinantes/aislamiento & purificación , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Verrucomicrobia/genética , Verrucomicrobia/metabolismo , Monofenol Monooxigenasa/genética , Monofenol Monooxigenasa/metabolismo , Monofenol Monooxigenasa/química , Proteínas/genética , Proteínas/química , Proteínas/aislamiento & purificación , Hidroxilación , Escherichia coli/genética , Escherichia coli/metabolismo
3.
BMC Gastroenterol ; 24(1): 112, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38491416

RESUMEN

PURPOSE: Rectal anastomoses have a persisting high incidence of anastomotic leakage. This study aimed to assess whether the use of a poly-ϵ-caprolactone (PCL) scaffold as reinforcement of a circular stapled rectal anastomosis could increase tensile strength and improve healing compared to a control in a piglet model. METHOD: Twenty weaned female piglets received a stapled rectal anastomosis and were randomised to either reinforcement with PCL scaffold (intervention) or no reinforcement (control). On postoperative day five the anastomosis was subjected to a tensile strength test followed by a histological examination to evaluate the wound healing according to the Verhofstad scoring. RESULTS: The tensile strength test showed no significant difference between the two groups, but histological evaluation revealed significant impaired wound healing in the intervention group. CONCLUSION: The incorporation of a PCL scaffold into a circular stapled rectal anastomosis did not increase anastomotic tensile strength in piglets and indicated an impaired histologically assessed wound healing.


Asunto(s)
Fuga Anastomótica , Caproatos , Lactonas , Grapado Quirúrgico , Animales , Femenino , Anastomosis Quirúrgica/efectos adversos , Fuga Anastomótica/prevención & control , Fuga Anastomótica/etiología , Recto/cirugía , Porcinos
4.
Macromol Rapid Commun ; 45(13): e2400022, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38704741

RESUMEN

The preparation of self-healing polyurethane elastomers (PUEs) incorporating dynamic bonds is of considerable practical significance. However, developing a PUE with outstanding mechanical properties and high self-healing efficiency poses a significant challenge. Herein, this work has successfully developed a series of self-healing PUEs with various outstanding properties through rational molecular design. These PUEs incorporate m-xylylene diisocyanate and reversible dimethylglyoxime as hard segment, along with polytetramethylene ether glycol as soft segment. A significant amount of dynamic oxime-carbamate and hydrogen bonds are formed in hard segment. The microphase separated structure of the PUEs enables them to be colorless with a transparency of >90%. Owing to the chemical composition and multiple dynamic interactions, the PUEs are endowed with ultra-high tensile strength of 34.5 MPa, satisfactory toughness of 53.9 MJ m-3, and great elastic recovery both at low and high strains. The movement of polymer molecular chains and the dynamic reversible interactions render a self-healing efficiency of 101% at 70 °C. In addition, this self-healing polyurethane could still maintain high mechanical properties after recycling. This study provides a design strategy for the preparation of a comprehensive polyurethane with superior overall performance, which holds wide application prospects in the fields of flexible displays and solar cells.


Asunto(s)
Carbamatos , Elastómeros , Enlace de Hidrógeno , Oximas , Poliuretanos , Resistencia a la Tracción , Poliuretanos/química , Oximas/química , Elastómeros/química , Carbamatos/química , Estructura Molecular , Elasticidad
5.
Clin Oral Implants Res ; 35(7): 739-746, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38647359

RESUMEN

AIM: To determine the tensile load capacity (TLC) and the tearing characteristics for interrupted and vertical mattress sutures with different insertion points from the wound margin, and the effect of the bite size when using vertical mattress sutures. MATERIALS AND METHODS: A total of 120 gingiva and lining mucosa samples obtained from pig jaws were divided into groups according to the suturing technique (interrupted and vertical mattress sutures), distance of the insertion points from the wound margin (margin, 1, 3, and 5 mm) and bite size (1, 3, and 5 mm). The TLC of the suture and the tearing characteristics were evaluated using a tensile tester device. RESULTS: The TLC was significantly higher for vertical mattress sutures than for interrupted sutures regardless of the distance of the insertion points from the wound margin (intergroup p < .001). This distance significantly influenced the TLC for vertical mattress sutures (p < .05) but not for interrupted sutures (p > .05). Testing the tearing characteristics revealed that no tissue tearing occurred in groups when the insertion points were more than 3 mm from the wound margin. CONCLUSION: The TLC is higher for vertical mattress sutures than for interrupted sutures, and it increases when the insertion points are farther from the wound margin.


Asunto(s)
Técnicas de Sutura , Resistencia a la Tracción , Animales , Porcinos , Técnicas In Vitro , Encía/cirugía , Mucosa Bucal/cirugía
6.
Clin Oral Investig ; 28(4): 240, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38570397

RESUMEN

OBJECTIVES: Thermoplastic polymers show alteration in their mechanical properties after thermoforming on a dental model. The purpose of this in-vitro study was to evaluate the tensile strength of different thermoplastic polymer sheets thermoformed on a pre-treatment (moderate crowding) and post-treatment (well-aligned) maxillary model of a patient. MATERIALS AND METHODS: Forty maxillary models (Twenty Pre-treatment & twenty Post-treatment of uniform dimension) were made by duplicating them using alginate Hydrogum 5 (Zhermack). Samples were then divided into eight groups of 5 samples each. The thermoplastic sheets Imprelon® (Scheu-Dent), AVAC R® (Jaypee), Placa Crystal® (BioART), EZ-VAC® (3A Medes)-1.0 mm thick were thermoformed on these models respectively. The sample was retrieved using ceramic bur mounted on a straight hand-piece and subjected for testing using TINIUS Olsen 10ST micro universal testing machine and recorded. RESULTS: There was no statistically significant difference (P > .05) in tensile strength of thermoformed thermoplastic polymer sheets between pre-treatment and post-treatment maxillary model. Tensile strength of EZ-VAC (3A Medes) showed higher variation between pre-treatment and post-treatment maxillary model though it was found to be statistically insignificant (P > .05). Significant difference (P < .05) was seen between groups when they were compared separately among pre-treatment and post-treatment models. CONCLUSION: Placa Crystal (BioART) among the pre-treatment group, EZ - VAC (3A Medes) among the post-treatment group, showed highest tensile strength. CLINICAL RELEVANCE: Results of the study highlights the necessity to test materials in conditions which stands in accordance with the clinical scenario to a considerable extent and also emphasizes the need for further study in aligner.


Asunto(s)
Cerámica , Polímeros , Humanos , Resistencia a la Tracción , Polímeros/química , Ensayo de Materiales
7.
Fetal Diagn Ther ; : 1-11, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38824911

RESUMEN

INTRODUCTION: Suture tensile properties have only been tested in extrauterine environments. Amniotic fluid (AF) is a complex milieu of enzymes and inflammatory factors. This study tested the mechanical properties of sutures with a variety of inherent properties, after exposure to AF from patients with conditions prompting fetal intervention. METHODS: AF was obtained from 3 patients with twin-twin transfusion syndrome (TTTS), and 3 patients with neural tube defects. Six types of 2-0 sutures were placed on 1.2 N of tension to mimic placement in vivo, and incubated in AF at 37°C (98.6°F). These included ethylene terephthalate (Ethibond), glycomer 631 (V-Loc), poliglecaprone 25 (Monocryl), poly-4-hydroxybutyrate (Monomax), polydioxanone (PDS), and polyglactin 910 (Vicryl). Failure load, stress, strain, and initial modulus were tested after 24 h of incubation and after 4 weeks, and compared with control (unincubated) sutures using t tests, Kruskal-Wallis tests, and stress-strain curves. RESULTS: Poliglecaprone 25 and polyglactin 910 dissolve more quickly in AF compared to outside the uterus, disintegrating at 4 weeks. Ethylene terephthalate and PDS experienced little change across 4 weeks of incubation. Glycomer 631 and poly-4-hydroxybutyrate exhibited interesting behavior in AF: glycomer 631 became more deformable at 24 h but later regained toughness by 4 weeks, while poly-4-hydroxybutyrate became tougher and in some cases stronger with time in AF. As a class, braided sutures act more like rigid materials, and monofilaments act like deformable plastics. CONCLUSION: These findings along with other suture characteristics such as ease of handling and availability may inform fetal intervention teams as they optimize procedures in a relatively new surgical field.

8.
Molecules ; 29(6)2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38542935

RESUMEN

The phase, mechanical properties, corrosion resistance, hydrophobicity, and interfacial contact resistance of Hastelloy X were investigated to evaluate its performance in proton exchange membrane fuel cells (PEMFCs). For comparison, the corresponding performance of 304 stainless steel (304SS) was also tested. Hastelloy X exhibited a single-phase face-centered cubic structure with a yield strength of 445.5 MPa and a hardness of 262.7 HV. Both Hastelloy X and 304SS exhibited poor hydrophobicity because the water contact angles were all below 80°. In a simulated PEMFC working environment (0.5 M H2SO4 + 2 ppm HF, 80 °C, H2), Hastelloy X exhibited better corrosion resistance than 304SS. At 140 N·cm-2, the interfacial contact resistance of Hastelloy X can reach as low as 7.4 mΩ·cm2. Considering its overall performance, Hastelloy X has better potential application than 304SS as bipolar plate material in PEMFCs.

9.
Molecules ; 29(9)2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38731653

RESUMEN

In pursuit of enhancing the mechanical properties, especially the tensile strength, of 4D-printable consumables derived from waste cooking oil (WCO), we initiated the production of acrylate-modified WCO, which encompasses epoxy waste oil methacrylate (EWOMA) and epoxy waste oil acrylate (EWOA). Subsequently, a series of WCO-based 4D-printable photocurable resins were obtained by introducing a suitable diacrylate molecule as the second monomer, coupled with a composite photoinitiator system comprising Irgacure 819 and p-dimethylaminobenzaldehyde (DMAB). These materials were amenable to molding using an LCD light-curing 3D printer. Our findings underscored the pivotal role of triethylene glycol dimethacrylate (TEGDMA) among the array of diacrylate molecules in enhancing the mechanical properties of WCO-based 4D-printable resins. Notably, the 4D-printable material, composed of EWOA and TEGDMA in an equal mass ratio, exhibited nice mechanical strength comparable to that of mainstream petroleum-based 4D-printable materials, boasting a tensile strength of 9.17 MPa and an elongation at break of 15.39%. These figures significantly outperformed the mechanical characteristics of pure EWOA or TEGDMA resins. Furthermore, the EWOA-TEGDMA resin demonstrated impressive thermally induced shape memory performance, enabling deformation and recovery at room temperature and retaining its shape at -60 °C. This resin also demonstrated favorable biodegradability, with an 8.34% weight loss after 45 days of soil degradation. As a result, this 4D-printable photocurable resin derived from WCO holds immense potential for the creation of a wide spectrum of high-performance intelligent devices, brackets, mold, folding structures, and personalized products.

10.
J Evid Based Dent Pract ; 24(1): 101952, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38448126

RESUMEN

BACKGROUND: In order to achieve uneventful and rapid healing of the tissues, a suture material should be biocompatible, easy to handle, sterile, and have good and uniform tensile strength. Hence, in the present study, characterization of the suture materials was done through a novel green chemistry approach using Punica granatum seed extract. MATERIALS AND METHODS: Ethanolic extract of P. granatum seed was prepared by dissolving 25 g of P. granatum seed powder with 100 mL of ethanol. The obtained extract was coated in silk and Vicryl suture material and was tested for its surface morphology (SEM), tensile strength, anti-microbial activity, biocompatibility, and wound healing potential. RESULTS: Silk and Vicryl sutures coated with P. granatum seed extract showed the uniform coating and deposition of extract with sustaining integrity. Vicryl suture coated with the extract had good tensile strength and antimicrobial activity. The in vitro scratch assay and biocompatibility test showed that the P. granatum seed extract had excellent wound healing potential and can be used without any effect on the viability of the normal cells. CONCLUSION: Within the limitations of the study it can be concluded that P. granatum seed extract coated Vicryl sutures had good tensile strength and anti-microbial activity. P. granatum seed extract also showed excellent biocompatibility and wound healing potential.


Asunto(s)
Granada (Fruta) , Humanos , Proyectos Piloto , Poliglactina 910 , Suturas , Seda , Etanol , Extractos Vegetales/farmacología
11.
Dent Res J (Isfahan) ; 21: 19, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38476715

RESUMEN

Background: This study assessed the effect of different concentrations of 4-methacryloyloxyethy trimellitate anhydride (4-META) added to silane on microtensile bond strength (µTBS) of light-cure and dual-cure resin cement to hybrid and zirconia-reinforced lithium silicate ceramics. Materials and Methods: This in vitro, experimental study was conducted on 32 Celtra Duo and 32 VITA Enamic ceramics bonded to Allcem Veneer light-cure and Allcem dual-cure resin cements using silane impregnated with 4-META in 0%, 2.5%, 5%, and 10 wt% concentrations in 16 groups (n = 4). The µTBS of specimens was measured by a universal testing machine and analyzed by the Kruskal-Wallis and Mann-Whitney tests, and the mode of failure was determined under a stereomicroscope and analyzed by the Chi-square test (alpha = 0.05). Results: The lowest mean µTBS was recorded in the Enamic ceramic group with 4-META (0%) bonded to dual-cure cement (14.26 MPa), and the highest mean µTBS was recorded in Enamic ceramic with 4-META (10%) bonded to light-cure cement (18.59 MPa) (P < 0.001). The µTBS of Celtra Duo was significantly higher than that of Enamic in bonding to light-cure cement using 4-META (2.5%) (P = 0.003). All failures (100%) were adhesive in most groups. The frequency of adhesive failure was the lowest (90%) in Celtra Duo bonded to dual-cure cement with 4-META (5%). Conclusion: According to the results of this pilot study, the addition of 4-META (10%) to silane caused a significant improvement in µTBS to light-cure cement. The addition of 4-META in all concentrations significantly improved the µTBS to Enamic ceramic in the use of dual-cure cement; however, it had no significant effect on µTBS of Celtra Duo. Nonetheless, the results should be interpreted with caution due to the relatively small sample size.

12.
Sci Rep ; 14(1): 8648, 2024 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622156

RESUMEN

Geotextiles made from plant fibers creates a suitable environment for plant growth as part of soil bioengineering techniques. The faster decomposition of plant fiber geotextiles compared to synthetic ones demands the use of composites that enhance their waterproofing and extend their durability in the environment. The objective of this work was to evaluate the resistance of a geotextile made with Thypha domingensis to degradation caused by climatic variables. Tensile strength tests were conducted in the laboratory in order to evaluate the degradation of geotextiles treated with single and double layers of waterproofing resin. Based on Scanning Electron Microscopy (SEM) images, it was verified that applying double layer of waterproofing resin delays the fibers degradation up to 120 days of exposure to the effects of climatic variables other than temperature. The maximum resistance losses due to the geotextile's exposure to degradation were statistically significant for all three treatments: control-without waterproofing resin, with one layer resin, and with two layers resin. Therefore, waterproofing resin, provides a long-term protective solution for geotextiles made from cattail fibers.


Asunto(s)
Typhaceae , Resistencia a la Tracción , Estructuras de las Plantas
13.
Int J Biol Macromol ; 260(Pt 2): 129596, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38253158

RESUMEN

Viscose fabrics have been widely used in various applications, but their potential fire hazard has been a concern. To address this issue, improving the flame retardancy of viscose fabrics has become a significant priority. Phytic acid (PA) and xylitol were used to create a novel flame retardant, PAXY. PAXY was finished on viscose fabrics by pad-dry-curing process, and the performance of coated viscose fabrics was investigated. The results showed that the limiting oxygen index value of PAXY13-100 (fabrics finished with a 100 g/L flame-retardant solution and the flame retardant synthesized by a 1: 3 M ratio of PA to xylitol) reached 32.8 % and the heat release rate value was decreased by 77 %. Based on the findings from the analysis of both the gas phase and condensed phase products, PAXY promoted the dehydration of viscose fabrics to produce a denser char layer, which inhibited the production of flammable gases. Surprisingly, the breaking force retention of PAXY13-100 reached 90 % in warp and 114 % in weft. Compared with that of 100 g/L PA-treated fabrics, the breaking force of PAXY13-100 increased by nearly 400 %. This work provides a new strategy for PA-based flame-retardant finishing with the synergy of flame retardancy and breaking force retention.


Asunto(s)
Retardadores de Llama , Resistencia a la Tracción , Ácido Fítico , Xilitol , Gases
14.
Sci Rep ; 14(1): 14840, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937510

RESUMEN

This research added rare Earth elements Ce to the P110-grade oil casing steel to reveal their influence on the inclusions and tensile properties. The content of cerium in the steel varied from 0 to 452 ppm. Based on the classical thermodynamic calculation, the predominance diagram of Re-containing inclusions in P110-grade steel was obtained. The evolution route of the inclusions composition with the increasing cerium content in the steel was xCaO⋅yAl2O3 → Al2O3-CeAlO3 → Ce2O3-CeAlO3 → Ce2O3-Ce2O2S → Ce2O2S, which agreed well with the thermodynamic analysis. As the cerium content at 235 ppm, the size of Ce containing inclusions has a minimal size at 2.82 µm. Suitable Ce content can modify the big-size xCaO⋅yAl2O3 inclusions into small-size Re-containing inclusions. The results demonstrate that the tensile performance of this steel can be improved as the cerium content increases from 0 to 235 ppm. However, once the cerium content exceeds 235 ppm, further increases in cerium content led to a decline in performance. The experimental results shows that the presence of large-sized Ce2O2S inclusions and the change of microstructure, will lead to the decrease in tensile performance.

15.
Materials (Basel) ; 17(6)2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38541604

RESUMEN

The purpose of this study is to investigate the macro and micro properties of stabilized recycled aggregate base layers using gypsum slag cement (GSC) and compare them with ordinary Portland cement (OPC). To achieve this, four levels of recycled aggregate content (0%, 50%, 60%, 70%) and three levels of binder materials (3.5%, 4.5%, 5.5%) were designed, where the binding materials included OPC and GSC. When GSC is used as the binding material with 0% recycled content, two scenarios for the ratio of slag to activator are considered: 4:1 and 4:2. For recycled content of 50%, 60%, and 70%, only the 4:1 ratio is considered. The macro-mechanical properties of the composite material were studied through compaction tests, unconfined compressive strength tests, and indirect tensile strength tests. Microscopic properties were investigated through X-ray diffraction (XRD) and scanning electron microscopy (SEM). Macroscopic test results indicate that, at an equal binder content, GSC exhibits a higher moisture content and maximum dry density compared to OPC. Moreover, the unconfined compressive strength and indirect tensile strength of GSC are higher than those of OPC. Microscopic test results reveal that the hydration products of both binding materials are essentially similar; however, under identical curing conditions, the hydration products of GSC are more abundant than those of OPC.

16.
J Int Soc Prev Community Dent ; 14(1): 69-77, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38559640

RESUMEN

Aim: The tensile strength and modulus of elasticity of gutta-percha cones can be chemically altered due to disinfectant solutions. Therefore, the aim of the present study was to compare tensile strength and elastic modulus of gutta-percha cones subjected to sodium hypochlorite (NaOCl) disinfection at different times. Materials and Methods: This in vitro and longitudinal experimental study consisted of 45 gutta-percha cones, divided equally into three groups: Group 1 (disinfection with 2.5% NaOCl), Group 2 (disinfection with 5.25% NaOCl), and control group. All groups were subdivided according to immersion times for 1, 5, and 10 minutes. Tensile strength and elastic modulus were measured with a universal testing machine. For comparing more than two independent groups, parametric analysis of variance test with Sheffe's post hoc was used and for multivariate analysis, and multivariate analysis of variance test based on Pillai's Trace was used. In all statistical analysis, a significance level P ≤ 0.05 was considered. Results: When comparing the tensile strength of gutta-percha cones, no significant differences were observed after being immersed at 1, 5, and 10 minutes in NaOCl 2.5% (P = 0.715) and 5.25% (P = 0.585). Regarding the elastic modulus, a significant decrease (P < 0.05) was observed in those that were immersed in NaOCl 2.5% and 5.25% for 1, 5, and 10 minutes. Furthermore, increased NaOCl concentration significantly reduced the elastic modulus (P < 0.001). However, there were no significant differences in tensile strength (P > 0.05) and elastic modulus (P > 0.05), when evaluating the interaction between NaOCl concentration and time. Conclusion: Increasing NaOCl concentration significantly reduced the modulus of elasticity without affecting the tensile strength of gutta-percha cones, regardless of immersion time. Furthermore, the interaction of time and NaOCl concentration did not significantly affect the tensile strength and elastic modulus.

17.
J Pharm Bioallied Sci ; 16(Suppl 1): S152-S155, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595471

RESUMEN

Objective: The purpose of this study was to determine the effect of common methods of sterilization on the tensile strength of Beta titanium, Stainless steel, Australian Stainless steel, Copper Nickel-Titanium, and Nickel-Titanium wires. It also aimed to evaluate the changes in tensile strength values caused by repeated cycles of sterilization. Materials and Methods: A sample of 225 orthodontic wires, i.e., beta-titanium, stainless steel, Australian stainless steel, copper nickel-titanium, and nickel-titanium wires, were collected from different manufacturers. These wires were divided into three groups, which consists of Groups 1, 2, and 3. Four methods of sterilization used in this study were as follows: (i) autoclave (250°F for 20 min), (ii) dry heat sterilization (375°F for 20 min), (iii) ethylene oxide sterilization (54°C for 4 hrs), and (iv) 2.45% acidic glutaraldehyde (10 hrs). Results: The results of this study showed that there was increase in tensile strength of beta-titanium and nickel-titanium wires using autoclave and dry heat sterilization. No statistically significant difference in tensile strength of stainless steel and Australian stainless steel archwires. The tensile strength of copper nickel-titanium wires decreased following 0, 1, and 5 cycles of sterilization. Conclusion: The lack of statistically significant differences established in the study of new and sterilized orthodontic archwires gives us reason to conclude that the orthodontic arch wires can be sterilized because the sterilizing processes do not affect their tensile strength and the orthodontists could thus ensure the maximum safety of their patients.

18.
J Pharm Bioallied Sci ; 16(Suppl 1): S156-S158, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595474

RESUMEN

Introduction: The application of the antioxidants after the teeth are bleached has been advocated to fasten the restorative process post-bleaching. The motive of this study was to examine and assess the micro-tensile binding strength of bleached enamel to the resin using a variety of antioxidant solutions. Finding the reason for the tooth fracture was the secondary outcome measured. Materials and Methods: An in vitro study was planned with 100 human extracted teeth, with 20 in each group with one as controls and 4 others tested for the antioxidants sodium ascorbate, epigallocatechin gallate, chitosan, and proanthocyanidin application. The bond strength of bleached enamel to the resin was well as the failure type was assessed after the values were noted and compared using the ANOVA and Tukey's methods keeping P < 0.05 as significant. Results: Epigallocatechin gallate specimens displayed the maximum micro-tensile bond strength under the investigational circumstances, whereas controls displayed the lowest micro-tensile bond strength. There was statistical alteration in micro-tensile bond strengths between all the groups except between epigallocatechin gallate vs chitosan and sodium ascorbate vs proanthocyanidin. High statistical significance was seen between the control and the antioxidant groups as well as between sodium ascorbate and epigallocatechin gallate and chitosan. Conclusion: The antioxidant chemicals significantly augmented the bond strength of bleached enamel to the resin that had been bleached. Also, when compared to the other experimental groups, epigallocatechin gallate and chitosan treatment displayed the greatest mean bond strength values.

19.
Artículo en Inglés | MEDLINE | ID: mdl-38627345

RESUMEN

Membrane separation technology in the last 40 years has experienced impressive growth, displacing conventional separation processes due to inherent advantages such as less capital investment, and energy efficiency and the devices were simple, compact, and modular. In the current work, we aimed to synthesize a thin-sheet nanofiltration membrane using chitosan (CS), poly(vinyl) alcohol (PVA), and montmorillonite nanoclay (MMT) for copper removal from aqueous solution. Thermogravimetric analysis and differential scanning calorimetry were employed to evaluate the thermal stability of a novel organic-inorganic hybrid membrane. The tensile strength was measured over a wide range of temperatures and pressure to determine its stability. The surface and cross-section morphology of the membrane were studied through scanning electron microscopy. The prepared membrane was then tested for filtration efficiency by adjusting parameters such as pH, pressure, metal ion concentration, and membrane thickness. A mechanism was proposed to explain the hooking of copper ions with the as-prepared membrane after spectral images, such as EDAX and FT-IR, were compared both before and after filtration.

20.
J Oral Sci ; 66(2): 107-110, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38403676

RESUMEN

PURPOSE: To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs). METHODS: Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch t-test, with Bonferroni correction. RESULTS: Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers. CONCLUSION: The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.


Asunto(s)
Níquel , Retenedores Ortodóncicos , Corrosión , Níquel/química , Alambres para Ortodoncia , Aparatos Ortodóncicos Fijos , Diseño Asistido por Computadora
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA